You are on page 1of 3
18V32CLX x 3SETS B220655 6200kWe X 3SETS DIESEL GENERATING PLANT FOR CHI MEI CORPORATION INSTRUCTION MANUALS Y-TYPE STRAINERS DRAWING TITLE DRAWING No. @® FOR STEAM SOLENOID VALVE P7901055A, FOR STEAM TEMPERATURE P7901057A REGULATING VALVE P7901059A ® FOR MAIN STARTING AIR LINE P7901050A NIIGATA ENGINEERING CO., LTD POWER SYSTEMS DIVISION POWER PLANT ENGINEERING DEPARTMENT HE-513 1/2 ‘This manual describes how to use the Strainers manufactured by VENN CO., LTD. to ensure best results in operation. 1. SPECIFICATIONS Fodel Wes Type a Item Cast iron bod Cast steel Body | KYW4 § Kee TyPe Applicable fluid Steam, gases and liquids 2 Up to, Flange Code vated pressure eee 10 & 16kgf/ea*e - |10, 16, 20 6 Wk /en?c See : : 30kgt /em2G Wax. “applicable ae ae Saati cies 220° 300°C 220% 2. CONSTRUCTION KY-3 & KY-6 Type Net Gasket Cap | : es) Size 50mm & over Size 40mm & over with plug. 3. INSTALLATION 1) Installation Example Strainer 8 vee ‘HE-513, 2/2 2) Install a stop Valve and a pressure gauge nearby the strainer a: shown in the Installation Example. If one each pressure gauge is installed at both sides of the Strainer, choking condition can be observed with the pressire differential between two gauges. 3) Install the Strainer to have the cap face downward. 4) Reserve a space at the installation in the length 5 times or more of the H length shown on the right undernieth the centre line of the piping for disassembly inspection. 5) Fixing and supporting of the piping is necessary to avoid direct load of the weight of the piping or heat stress on the Strainer. 4, MAINTENANCE & INSPECTION In order to ensure the function of the Strainer, inspect and clean the Strainer in a short interval at the early stage of the use to grasp the condition of the intrusion of the foreign matters to decide suitable regular cleaning period. In case of a long time non-operation, remove the drain inside the Strainer to keep from rusts or freezing. ‘The Strainers in the size over 50mm have plugs for the dischazge of drain. By taking off the plug, drain can be easily discharged and installation of a stop valve by taking off the plug will enable easy discharge. 5. CAUSE & REPAIRING OF TROUBLES Condition of troubles Cause Repair la. Choking of the net. Remove the foreign matters choking the net. Pressure down at lb. Pressure loss in the {b. Check the piping secondary side. pipe. and correct if (Shortage of flow) found unsuitable. jc, Wrong selection of mesh/c, Check the specifi- of the net, cations and change the mesh. a, Wrong selection of mesh|a. Check the specifi- : of the net. cations and change Passing of foreign the mesh, matters. b. Damages of the net. |b. Replace the net.

You might also like