18V32CLX x 3SETS B220655
6200kWe X 3SETS DIESEL GENERATING PLANT
FOR
CHI MEI CORPORATION
INSTRUCTION MANUALS
Y-TYPE STRAINERS
DRAWING TITLE DRAWING No.
@® FOR STEAM SOLENOID VALVE P7901055A,
FOR STEAM TEMPERATURE P7901057A
REGULATING VALVE P7901059A
® FOR MAIN STARTING AIR LINE P7901050A
NIIGATA ENGINEERING CO., LTD
POWER SYSTEMS DIVISION
POWER PLANT ENGINEERING DEPARTMENTHE-513 1/2
‘This manual describes how to use the Strainers manufactured by VENN CO., LTD.
to ensure best results in operation.
1. SPECIFICATIONS
Fodel Wes Type a
Item Cast iron bod Cast steel Body | KYW4 § Kee TyPe
Applicable fluid Steam, gases and liquids
2 Up to, Flange Code vated pressure
eee 10 & 16kgf/ea*e - |10, 16, 20 6 Wk /en?c
See : : 30kgt /em2G
Wax. “applicable ae ae
Saati cies 220° 300°C 220%
2. CONSTRUCTION
KY-3 & KY-6 Type
Net
Gasket
Cap
| : es)
Size 50mm & over Size 40mm & over
with plug.
3. INSTALLATION
1) Installation Example
Strainer
8 vee‘HE-513, 2/2
2) Install a stop Valve and a pressure gauge nearby the strainer a:
shown in the Installation Example.
If one each pressure gauge is installed at both sides of the
Strainer, choking condition can be observed with the pressire
differential between two gauges.
3) Install the Strainer to have the cap face downward.
4) Reserve a space at the installation in the length
5 times or more of the H length shown on the
right undernieth the centre line of the piping
for disassembly inspection.
5) Fixing and supporting of the piping is necessary to avoid direct
load of the weight of the piping or heat stress on the Strainer.
4, MAINTENANCE & INSPECTION
In order to ensure the function of the Strainer, inspect and clean
the Strainer in a short interval at the early stage of the use to
grasp the condition of the intrusion of the foreign matters to decide
suitable regular cleaning period.
In case of a long time non-operation, remove the drain inside the
Strainer to keep from rusts or freezing.
‘The Strainers in the size over 50mm have plugs for the dischazge of
drain. By taking off the plug, drain can be easily discharged and
installation of a stop valve by taking off the plug will enable easy
discharge.
5. CAUSE & REPAIRING OF TROUBLES
Condition of troubles Cause Repair
la. Choking of the net. Remove the foreign
matters choking the
net.
Pressure down at lb. Pressure loss in the {b. Check the piping
secondary side. pipe. and correct if
(Shortage of flow) found unsuitable.
jc, Wrong selection of mesh/c, Check the specifi-
of the net, cations and change
the mesh.
a, Wrong selection of mesh|a. Check the specifi-
: of the net. cations and change
Passing of foreign the mesh,
matters.
b. Damages of the net. |b. Replace the net.