You are on page 1of 173

EMCO Ref AR1602.

03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

INSTRUMENTS DATASHEETS

00 07/12/2016 Issued For Review AGM MAS YLH

Rev Date Description Prepared By Checked By Approved By Company Approval

Page 1/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

NOTES
1- Process data shall be provided following the approval of the M&HB after HAZOP session.
2- The information marked with (*) shall be provided by VENDOR.
3- The VENDOR shall provide the following requirements:
a-Index and Schedule.
b-Technical Specification / Datasheet.
c-Dimensional Drawings.
d-Detailed Drawings.
e-Schematic diagram.
f-Detailed Items list.
g-Installation,Operation and Maintenance Manual.
h-Catalogs.
i-Inspection and Test Report.
j-Inspection Procedure.
k-Certificate of Guarantee.
l-Deviation List.
m-Spare part list for Construction,Commissioning, Start-up and 2 years of operations.
n-Manufacturer Data Book (MDB).
4- Reference Documents
AR1602.03-PIP-REP-001 PROJECT
PROJECT
PIPING
PIPING
AND
AND
VALVE
VALVE
SPECIFICATION.
SPECIFICATION.
AR1602.03-PRO-DRW-008 REV01 WELLSITES
CPF P&IDs.
AND FLOWLINES P&IDs.
AR1602.03-INS-LST-001 REV00 INSTRUMENTS LIST.

ABBREVIATIONS
CS Carbon Steel
IP Ingress Protection
LED Light Emitting Diode
NA Not Applicable
NPT National Pipe Thread
PTFE Polytetrafluoroethylene
RF Raised Face
RTJ Ring Type Joint
SIL Safety Integrity Level
SS Stainless Steel

Page 2/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

INDEX
Sh.N DESIGNATION REVISIONS Sh.N DESIGNATION REVISIONS

1 COVER 00 51 PCV4100 TDS 00

2 NOTES 00 52 LCV4101 TDS 00

3 INDEX 1 00 53 PCV4100 TDS 00

4 INDEX 2 00 54 LCV4100 TDS 00

5 ESDV4000 TDS 00 55 TI/TW4101 TDS 00

6 TI/TW4000 TDS 00 56 LG4100/LG 4101/LIT4100 TDS 00

7 TI/TW4003 TDS 00 57 LSHH4100 TDS 00

8 TI/TW4001 TDS 00 58 LSLL4100 TDS 00

9 TI/TW4002 TDS 00 59 PSLL4100 TDS 00

10 PSV4000 TDS 00 60 PIT4100 TDS 00

11 PSV4001 TDS 00 61 LG4102/LIT4101 TDS 00

12 PCV4000 TDS 00 62 TIT/TW4102 TDS 00

13 PCV4001 TDS 00 63 PI4101 TDS 00

14 LCV4000 TDS 00 64 SDV4150 TDS 00

15 LCV4001 TDS 00 65 TI/TW4150 TDS 00

16 TIT/TW4004 TDS 00 66 PSV4150 TDS 00

17 PI4001 TDS 00 67 PSV4151 TDS 00

18 FT4000 TDS 00 68 LSLL4150 TDS 00

19 PIT4000 TDS 00 69 LSHH4150 TDS 00

20 PSLL4000 TDS 00 70 PSLL4150 TDS 00

21 LG 4000/LIT4001 TDS 00 71 TI/TW4151 TDS 00

22 LG4001/LG 4000/LIT4000 TDS 00 72 LG4152/LIT4151 TDS 00

23 LSHH4000 TDS 00 73 LG4150/LG 4151/LIT4150 TDS 00

24 LSLL4000 TDS 00 74 PIT4150 TDS 00

25 FT4001 TDS 00 75 PI4151 TDS 00

26 FT4002 TDS 00 76 TIT/TW4153 TDS 00

27 TI/TW4050 TDS 00 77 PCV4150 TDS 00

28 LG 4052/LIT4051 TDS 00 78 LCV4150 TDS 00

29 LG4050/LG4051/LIT4050 TDS 00 79 PCV4151 TDS 00

30 LSHH4050 TDS 00 80 LCV4151 TDS 00

31 LSLL4050 TDS 00 81 PSLL4650 TDS 00

32 PSLL4050 TDS 00 82 PSLL4651 TDS 00

33 PIT4050 TDS 00 83 PI4650 TDS 00

34 PSV4050 TDS 00 84 PI4651 TDS 00

35 PSV4051 TDS 00 85 PIT 4330 TDS 00

36 ESDV4050 TDS 00 86 PCV 4330 TDS 00

37 TI/TW4053 TDS 00 87 PT 4330 TDS 00

38 PI4051 TDS 00 88 LSHH4400 TDS 00

39 TIT/TW4052 TDS 00 89 TI/TW4400 TDS 00

40 FT4052 TDS 00 90 PI4400 TDS 00

41 PCV4050 TDS 00 91 PSLL4400 TDS 00

42 LCV4050 TDS 00 92 LG 4000/LIT4001 TDS 00

43 PCV4051 TDS 00 93 SDV4400 TDS 00

44 LCV4051 TDS 00 94 PI 4401 TDS 00

45 FT4051 TDS 00 95 PT 4401 TDS 00

46 FT4053 TDS 00 96 TT/TW4401 TDS 00

47 ESDV4100 TDS 00 97 FT4400 TDS 00

48 TI/TW4100 TDS 00 98 TI/TW4003 TDS 00

49 PSV4100 TDS 00 99 TI/TW4001 TDS 00

50 PSV101 TDS 00 100 TI/TW4002 TDS 00

Page 3/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

INDEX
Sh.N DESIGNATION REVISIONS Sh.N DESIGNATION REVISIONS

101 PSV4400/4401 TDS 00 151 PCV4701 TDS 00

102 SDV4500 TDS 00 152 PCV4700 TDS 00

103 PI4500 TDS 00 153 PSV4700 TDS 00

104 PI4501 TDS 00 154 PSV4701 TDS 00

105 PIT 4330 TDS 00 155 PSHH4700 TDS 00

106 LSHH4500 TDS 00 156 PIT4700 TDS 00

107 LIT 4300/LG 4300 TDS 00 157 PI4700 TDS 00

108 LIT 4350/LG 4350 TDS 00 158 LSLL4700 TDS 00

109 FT 4350 TDS 00 159 LG 4700/LIT4700 TDS 00

110 LIT 4450 TDS 00 160 LIT4701 TDS 00

111 LSHH 4300 TDS 00 161 LSHH4700 TDS 00

112 LSHH 4350 TDS 00 162 SDV4700 TDS 00

113 LSHH 4450 TDS 00 163 PI4701 TDS 00

114 LSLL 4350 TDS 00 164 DPI4700 TDS 00

115 LSLL 4450 TDS 00 165 LCV4700 TDS 00

116 LV 4300 TDS 00 166 PRV4500 TDS 00

117 PCV 4301 TDS 00 167 TI/TW4500 TDS 00

118 PCV 4301 TDS 00 168 PVRV4500 TDS 00

119 PI 4300 TDS 00 169 LIT4500 TDS 00

120 PI 4301 TDS 00 170 BDV XXXX TDS 00

121 PI 4350 TDS 00 171 BDV4000 TDS 00

122 PI 4351 TDS 00 172 BDV4100 TDS 00

123 PI 4300 TDS 00 173 BDV4200 TDS 00

124 PI 4450 TDS 00 174

125 PI 4451 TDS 00 175

126 PI 4800 TDS 00 176

127 PI 4801 TDS 00 177

128 PIT 4300 TDS 00 178

129 PIT 4351 TDS 00 179

130 PIT 4450 TDS 00 180

131 PSHH 4300 TDS 00 181

132 PSHH 4350 TDS 00 182

133 PSLL 4300 TDS 00 183

134 PSLL 4350 TDS 00 184

135 PSLL 4751 TDS 00 185

136 PSV 4300 TDS 00 186

137 PSV 4301 TDS 00 187

138 PSV 4350 TDS 00 188

139 PSV 4351 TDS 00 189

140 SDV 4200 TDS 00 190

141 SDV 4273 TDS 00 191

142 SDV 4300 TDS 00 192

143 SDV 4350 TDS 00 193

144 SDV 4450 TDS 00 194

145 TI/TW 4300 TDS 00 195

146 TI/TW 4350 TDS 00 196

147 TT/TW 4351 TDS 00 197

148 TT/TW 4450 TDS 00 198

149 PVRV 4450 TDS 00 199

150 PRV4450 TDS 00 200

Page 4/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

SHUTDOWN VALVE DATASHEET


1 Tag Number ESDV4000

2 Service Shutdown Valve

GENERAL 3 Line Number P&ID Number 6"-PF-C31X-4000 AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location - TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design


PROCESS
8 Pressure (Barg)
DATA
9 Temperature (C)

10 Mass Density (Kg/m3)

11 Type Ball Valve

12 Body Size Port Size 6" Full Bore

13 Maximum Pressure Maximum Temperature (*) (*)

14 Body Material CS

15 Fire Safe YES


VALVE BODY
16 Class Size Flanged RTJ 600# 6"
CHARACTERISTICS Process Connection Type
17 Downstream Flanged 6" 600# RTJ

18 Type of Bonnet Bolted

19 Lubrication Lube Type Required (*)

20 Packing Material PTFE

21 Bolting Material CS

22 Type Trunnion Mounted

23 Size Rated Travel (*) (*)

TRIM 24 Service ON / OFF Valve


CHARACTERISTICS 25 Ball Material SS

26 Seat Insert PTFE

27 Stem Material SS

28 Type Pneumatic and Pinion Spring Return

29 Size (*)

30 Fail Position Closed


ACTUATOR
31 Max. Operating Pressure Max. Allowable Pressure (*) (*)
CHARACTERISTICS
32 Stroking Time Torque 10 sec (*)

33 Handwheel Not Required

34 Safety Factor 100%

35 Tag Number SDY4000

36 Type 3-way Valve

37 Input Signal 24 VDC

SOLENOID VALVE 38 Fluid Instrument Air

39 SIL Enclosure/ATEX Class - IP54 -

40 Body Size Body Material (*) (*)

41 Connection Type Cable Gland (*) M20x1.5

42 Quantity Type 2 Proximity Switch

43 Tag Number ZSC4000 ZSO4000


LIMIT SWITCH
44 Designation Closed Open

45 Enclosure Class Cable Gland - M20x1.5

UTILITIES 46 Fluid Pressure Instrument Air -

49 ATEX Certificate Sour Service Certificate Required Required

50 SIL Certificate Leakage Test Required Required

MISCELLANEOUS 51 Spare Parts Required for Construction, Commissioning and Start-up

52 Vendor Manufacturer (*) (*)

53 Purchase Order Number Serial Number (*) (*)

Page 5/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW4000

2 Service Temperature Indicator

GENERAL 3 Line Number P&ID Number 6"-PF-C31X-4000 AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location - TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3)

11 Flowrate (Kg/h)

12 Type Bi-Metal

13 Range

14 Stem Type Threaded

15 Stem Material SS

16 Stem Length Stem Diameter (*) (*)


THERMOMETER
17 Dial Size Dial Color 150 mm White

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP54

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7"

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 6/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW4003

2 Service Temperature Indicator

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location MBD-4000 TEST SEPARATOR

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3)

11 Flowrate (Kg/h)

12 Type Bi-Metal

13 Range

14 Stem Type Threaded

15 Stem Material SS

16 Stem Length Stem Diameter (*) (*)


THERMOMETER
17 Dial Size Dial Color 150 mm White

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP54

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7"

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 7/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW4001

2 Service Temperature Indicator

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location MBD-4000 TEST SEPARATOR

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3)

11 Flowrate (Kg/h)

12 Type Bi-Metal

13 Range

14 Stem Type Threaded

15 Stem Material SS

16 Stem Length Stem Diameter (*) (*)


THERMOMETER
17 Dial Size Dial Color 150 mm White

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP54

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7"

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 8/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW4002

2 Service Temperature Indicator

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location MBD-4000 TEST SEPARATOR

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3)

11 Flowrate (Kg/h)

12 Type Bi-Metal

13 Range

14 Stem Type Threaded

15 Stem Material SS

16 Stem Length Stem Diameter (*) (*)


THERMOMETER
17 Dial Size Dial Color 150 mm White

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP54

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7"

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 9/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SAFETY VALVE


1 Tag Number PSV4000

2 Service Pressure Safety Valve

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Equipment Designation MBD4000 TEST SEPARATOR

5 Location / Area ZONE 2

6 Area Classification ZONE 2

7 Fluid Two phase Crude Oil

8 Min Operating Max Design

9 Pressure (Barg) - - - -

10 Temperature (C) - - - -

11 Set Pressure (Barg) -

12 Back Pressure (Barg) -

13 Specific Heat Ratio (Cp/Cv) -

PROCESS 14 Mass Density (Kg/m3) -


CONDITIONS 15 Molecular Weight -

16 Compressibility Factor Z -

17 Relieving Temperature (C)

18 Flowrate to Release (Kg/h) -

19 Medium to release -

20 Caculated Orifice Area -

21 Selected Orifice Area -

22 Rated Relief Capacity (Kg/h) -

23 Design Basis API 520

24 Valve Type Conventional

25 Relief Case Blocked Outlet

26 Body Material CS

27 Ingress Protection Class IP54


TECHNICAL DATA
28 Trim Material SS

29 Spring Material SS

30 Type of connection Flanged

31 Inlet Size Inlet Class - -

32 Outlet Size Outlet Class - -

OTHER 33 Fire Safe as per API 6FA

34 Certificate of Conformity Required

35 ATEX Certificate -

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Not Required

38 Leakage Test Not Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Model Number (*)

Page 10/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SAFETY VALVE


1 Tag Number PSV4001

2 Service Pressure Safety Valve

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Equipment Designation MBD4000 TEST SEPARATOR

5 Location / Area ZONE 2

6 Area Classification ZONE 2

7 Fluid Two phase Crude Oil

8 Min Operating Max Design

9 Pressure (Barg) - - - -

10 Temperature (C) - - - -

11 Set Pressure (Barg) -

12 Back Pressure (Barg) -

13 Specific Heat Ratio (Cp/Cv) -

PROCESS 14 Mass Density (Kg/m3) -


CONDITIONS 15 Molecular Weight -

16 Compressibility Factor Z -

17 Relieving Temperature (C)

18 Flowrate to Release (Kg/h) -

19 Medium to release -

20 Caculated Orifice Area -

21 Selected Orifice Area -

22 Rated Relief Capacity (Kg/h) -

23 Design Basis API 520

24 Valve Type Conventional

25 Relief Case Blocked Outlet

26 Body Material CS

27 Ingress Protection Class IP54


TECHNICAL DATA
28 Trim Material SS

29 Spring Material SS

30 Type of connection Flanged

31 Inlet Size Inlet Class - -

32 Outlet Size Outlet Class - -

OTHER 33 Fire Safe as per API 6FA

34 Certificate of Conformity Required

35 ATEX Certificate -

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Not Required

38 Leakage Test Not Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Model Number (*)

Page 11/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number PCV4000

2 Service Pressure Control Valve

GENERAL 3 Line Number P&ID Number 2"-PG-C31X-4010 AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location - TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Gas

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

17 Cp/Cv

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Gate

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position -

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 4..20mA Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 12/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number PCV4001

2 Service Pressure Control Valve

GENERAL 3 Line Number P&ID Number XX"-PG-C31X-4003 AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location - TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Gas

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

17 Cp/Cv

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Gate

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position -

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 4..20mA Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 13/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number LCV4000

2 Service Level Control Valve

GENERAL 3 Line Number P&ID Number 2"-PW-C31X-4006 AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location - TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Water

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

17 Cp/Cv

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Ball

23 Body Size Body Material CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position -

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 4..20mA Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 14/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number LCV4001

2 Service Level Control Valve

GENERAL 3 Line Number P&ID Number 3"-PW-A31X-4008 AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location - TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid CRUDE OIL

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

17 Cp/Cv

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Ball

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position -

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 4..20mA Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 15/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number TIT/TW4004

2 Service Temperature Indicator Transmitter

GENERAL 3 Line Number P&ID Number 4"-PG-C31X-4004 AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location - TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Measuring Element RTD

13 Range -

14 Material SS

ELEMENT 15 Mounting Thermowell Mounted

16 Number of Wires 3 Wires

17 Sensor Connection 1/2" NPT

18 Diameter (*)

19 Type HART Transmitter

20 Packing Material 3 Wire Pt 100

21 Nb of Wires 2 Wire Transmitter

22 Enclosure Class Ingress Protection #REF! IP54

23 Local Indicator LCD Display Required

TRANSMITTER 24 Power Supply 24 VDC Loop Powered

25 Level 4..20 mA HART


Output Signal
26 Accuracy Class 1

27 Cable Cable Gland 2x1.5 mm M20x1.5

28 Enclosure Material SS

29 Nameplate Required, Engraved with SS tag plate

30 Material 316 SS

31 Process Connection THREADED 1/2"

32 Sensor Connection 1/2" NPT

THERMOWELL 33 Calculated Immersion Length 7"

34 Selected Immersion Length (*)

35 External Diameter (*)

36 Construction Type Tapered

37 Certificate of Conformity Required

38 ATEX Certificate Required

39 Sour Service Certificate Not Required

MISCELLANEOUS 40 SIL Certificate Not Required

41 Leakage Test Not Required

42 Hydrostatic Test Not Required

43 Spare Parts Required for Construction, Commissioning and Start-up

44 Vendor Manufacturer (*) (*)

PURCHASE 45 Purchase Order Number Serial Number (*) (*)

46 Model Number (*)

Page 16/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI4001

2 Service Pressure Indicator

GENERAL 3 Line Number P&ID Number 4"-PG-C31X-4004 AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location - TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid GAS

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg) - - - -

9 Temperature (C) - - - -

10 Range -

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS

GAUGE DETAILS 15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

17 Fill Fluid NA

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Ingress Protection IP54

21 Connection Flanged

22 Bottom Housing Material SS

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge Threaded 1/2" NPT

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 17/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

FLOW TRANSMITTER DATASHEET


1 Tag Number FT4000

2 Service Flow Transmitter

GENERAL 3 Line Number P&ID Number 4"-PG-C31X-4004 AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location MBD4000 TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid GAS

7 Min Operating Max Design

8 Temperature (C) - - - -

PROCESS 9 Pressure (Barg) - - - -


DATA 10 Flowrate (Kg/h) -

11 Density (Kg/m3) -

12 Molecular Weight -

13 Viscosity -

14 Meter Type Integral Orifice Plate Flowmeter

15 Orifice Shape Square Edged

16 Bore Diameter (*)


METER
17 Upstream length Downstream Length 10 D 5D

18 Size & Type 4" RTJ


End Connections
19 Class 600#

20 Power Supply 24 VDC Loop Powered

21 Output Signal 4..20 mA


TRANSMITTER
22 Enclosure Class -

23 Cable Gland -

24 Manifold 5-valve manifold (2x1/4" Drain Screws + 2x1/4" Isolation Screws / 1x1/4" Equalizer)

25 Manifold Material SS

ACCESSORIES 26 Inlet 2x1/2" NPTM


Manifold End Connections
27 Outlet 2x1/2" NPTM

28 LCD Indicator Not Required

29 Certificate of Conformity Required

30 ATEX Certificate -

31 Sour Service Certificate Not Required

MISCELLANEOUS 32 SIL Certificate Not Required

33 Leakage Test Not Required

34 Hydrostatic Test Required

35 Spare Parts Required for Construction, Commissioning and Start-up

36 Vendor Manufacturer (*) (*)

PURCHASE 37 Purchase Order Number Serial Number (*) (*)

38 Model Number (*)

Page 18/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number PIT4000

2 Service Pressure Indicator Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number MBD4000

5 Location / Area -

6 Area Classification ZONE 2

7 Fluid Multiphase Crude Oil

8 Min Operating Max Design


PROCESS
9 Pressure (Barg) - - - -
CONDITIONS
10 Temperature (C) - - - -

11 Mass Density (Kg/m3) -

12 Instrument Range -

13 Element Type Diaphragm


ELEMENT
14 Element Material SS

15 Number of wires 2 wire sensor

16 Indicator Scale LCD Type Required (*)

17 Material SS

18 Process Connection Electrical Connection 1/2" NPT M20x1.5

TRANSMITTER 19 Power Supply Load Resistance 24 VDC Loop Powered (*)

20 Output Signal 4..20 mA HART

21 ATEX Rating Ingress Protection #REF! IP54

22 Accuracy Repeatability 0.05% (*)

23 Manifold 2-way valve : Isolation + vent + Drain


MANIFOLD
24 Size and Rating Inlet 1/2" NPTM x Outlet 1/2" NPTM ; Drain 1/4" NPTF ANSI Class 3000#

25 Certificate of Conformity Required

26 ATEX Certificate -

27 Sour Service Certificate Not Required

MISCELLANEOUS 28 SIL Certificate Not Required

29 Leakage Test Not Required

30 Hydrostatic Test Not Required

31 Spare Parts Required for Construction, Commissioning and Start-up

32 Vendor Manufacturer (*) (*)

PURCHASE 33 Purchase Order Number Serial Number (*) (*)

34 Model Number (*)

Page 19/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SWITCH DATASHEET


1 Tag Number PSLL4000 PSHH4000

2 Service Pressure Switch Low Low Pressure Switch High High

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location MBD4000 TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Switch Type SPDT/SNAP

13 Set point (Barg) - -

14 Setting Trip Factory Set

15 Operating Range -

16 Class 600#
Process Connection
17 Size 1/2" NPTM

18 Housing Material Aluminum

SWITCH 19 Enclosure Class Ingress Protection - IP54

20 Packing Material 2x1.5 mm

21 Power supply 24 VDC

22 Contact Arrangement 2NO/2NC

23 Cable Gland M20x1.5

24 External Adjustment Required

25 Accuracy (*)

26 Mounting On pipe

27 Manifold 2 Valve Manifold

28 Manifold Material SS

MANIFOLD 29 Inlet 1/2" NPTF

30 Manifold End Connections Outlet 1/2" NPTM

31 Drain 1/4" NPT

32 Local Display Not Required

33 Mounting Brackets Required


OPTIONS
34 Sun Shade Not Required

35 LED Indication Not Required

36 Certificate of Conformity Required

37 ATEX Certificate Not Required

38 Sour Service Certificate Not Required

MISCELLANEOUS 39 SIL Certificate Not Required

40 Leakage Test Not Required

41 Hydrostatic Test Not Required

42 Spare Parts Required for Construction, Commissioning and Start-up

43 Vendor Manufacturer (*) (*)

PURCHASE 44 Purchase Order Number Serial Number (*) (*)

45 Model Number (*)

Page 20/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

DUAL CHAMBER LEVEL GAUGE/TRANSMITTER DATASHEET


1 Tag Number LG 4000/LIT4001

2 Service Level Gauge/Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location MBD4000 TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid MULTIPHASE CRUDE OIL

7 Min Operating Max Design

8 Temperature (C) - - - -
PROCESS
9 Pressure (Barg) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Specific Gravity -

12 Viscosity -

13 Instrument Type Dual chamber

14 Gauge Type Glass

15 Connections Center to Center Distance -

16 Tube Material Glass

GAUGE 17 Size 2"


End Connection
18 Type Flanged 2", 600# RTJ

19 Body Material (*)

20 Cover Material SS

21 Mounting Side Mounted

22 Type Guided wave Radar

SENSOR 23 Insertion Depth -

24 Material SS

25 Indicator Required

26 Output 2 wires, 4..20 mA

27 Reliability -

TRANSMITTER 28 Mounting Integral

29 Power Supply Loop Powered 24 VDC

30 Enclosure Class -

31 Cable Gland -

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 21/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

DUAL CHAMBER LEVEL GAUGE/TRANSMITTER DATASHEET


1 Tag Number LG4001/LG 4000/LIT4000

2 Service Level Gauge/Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location MBD4000 TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid MULTIPHASE CRUDE OIL

7 Min Operating Max Design

8 Temperature (C) - - - -
PROCESS
9 Pressure (Barg) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Specific Gravity -

12 Viscosity -

13 Instrument Type Dual chamber

14 Gauge Type Gauge Quantity Glass 2

15 Connections Center to Center Distance - -

16 Tube Material Glass

GAUGE 17 Size 2"


End Connection
18 Type Flanged 2", 600# RTJ

19 Body Material (*)

20 Cover Material SS

21 Mounting Side Mounted

22 Type Guided wave Radar

SENSOR 23 Insertion Depth -

24 Material SS

25 Indicator Required

26 Output 2 wires, 4..20 mA

27 Reliability -

TRANSMITTER 28 Mounting Integral

29 Power Supply Loop Powered 24 VDC

30 Enclosure Class -

31 Cable Gland -

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 22/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSHH4000 LSLL4001

2 Service Pressure Switch Low Low Pressure Switch High High

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location MBD4000 TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

8 Pressure (Barg) - - - -
PROCESS
9 Temperature (C) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point - -

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Class 2" 600#


Process Connection
19 Size 1/2" NPTM

SWITCH 20 Body Material SS

21 Float Material SS

22 Enclosure Class Ingress Protection - IP54

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 23/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSLL4000

2 Service Pressure Switch Low Low

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location MBD4000 TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

8 Pressure (Barg) - - - -
PROCESS
9 Temperature (C) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point -

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Class 2" 600#


Process Connection
19 Size 1/2" NPTM

SWITCH 20 Body Material SS

21 Float Material SS

22 Enclosure Class Ingress Protection - IP54

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 24/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

FLOW TRANSMITTER DATASHEET


1 Tag Number FT4001

2 Service Flow Transmitter

GENERAL 3 Line Number P&ID Number 2"-PW-C31X-4006 AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location - TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Crude Oil

7 Min Operating Max Design

8 Temperature (C) - - - -

PROCESS 9 Pressure (Barg) - - - -


DATA 10 Flowrate (Kg/h) -

11 Density (Kg/m3) -

12 Molecular Weight -

13 Viscosity -

14 Meter Type Turbine

15 Upstream length Downstream Length 10 D 5D

16 Size & Type 2" RTJ


METER End Connections
17 Class 600#

18 Rotor Blades (*)


Material of Construction
19 Body (*)

20 Power Supply 24 VDC Loop Powered

21 Output Signal 4..20 mA

TRANSMITTER 22 Enclosure Class -

23 Cable Gland -

24 Totalizer Required

24 Certificate of Conformity Required

25 ATEX Certificate -

26 Sour Service Certificate Not Required

MISCELLANEOUS 27 SIL Certificate Not Required

28 Leakage Test Not Required

29 Hydrostatic Test Required

30 Spare Parts Required for Construction, Commissioning and Start-up

31 Vendor Manufacturer (*) (*)

PURCHASE 32 Purchase Order Number Serial Number (*) (*)

33 Model Number (*)

Page 25/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

FLOW TRANSMITTER DATASHEET


1 Tag Number FT4002

2 Service Flow Transmitter

GENERAL 3 Line Number P&ID Number 3"-PW-A31X-4008 AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location - TEST SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Crude Oil

7 Min Operating Max Design

8 Temperature (C) - - - -

PROCESS 9 Pressure (Barg) - - - -


DATA 10 Flowrate (Kg/h) -

11 Density (Kg/m3) -

12 Molecular Weight -

13 Viscosity -

14 Meter Type Turbine

15 Upstream length Downstream Length 10 D 5D

16 Size & Type 3" RF


METER End Connections
17 Class 300#

18 Rotor Blades (*)


Material of Construction
19 Body (*)

20 Power Supply 24 VDC Loop Powered

21 Output Signal 4..20 mA

TRANSMITTER 22 Enclosure Class -

23 Cable Gland -

24 Totalizer Required

25 Certificate of Conformity Required

26 ATEX Certificate -

27 Sour Service Certificate Not Required

MISCELLANEOUS 28 SIL Certificate Not Required

29 Leakage Test Not Required

30 Hydrostatic Test Required

31 Spare Parts Required for Construction, Commissioning and Start-up

32 Vendor Manufacturer (*) (*)

PURCHASE 33 Purchase Order Number Serial Number (*) (*)

34 Model Number (*)

Page 26/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW4050 TI/TW4051

2 Service Temperature Indicator

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Location MBD-4100 1ST STAGE SEPARATOR

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Type Bi-Metal

13 Range -

14 Stem Type Threaded

15 Stem Material SS

16 Stem Length Stem Diameter (*) (*)


THERMOMETER
17 Dial Size Dial Color 150 mm White

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP54

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7"

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 27/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

DUAL CHAMBER LEVEL GAUGE/TRANSMITTER DATASHEET


1 Tag Number LG 4052/LIT4051

2 Service Level Gauge/Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Location MBD-4100 1ST STAGE SEPARATOR

5 Area Classification ZONE 2

6 Fluid MULTIPHASE CRUDE OIL

7 Min Operating Max Design

8 Temperature (C) - - - -
PROCESS
9 Pressure (Barg) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Specific Gravity -

12 Viscosity -

13 Instrument Type Dual chamber

14 Gauge Type Glass

15 Connections Center to Center Distance -

16 Tube Material Glass

GAUGE 17 Size 2"


End Connection
18 Type Flanged 2", 600# RTJ

19 Body Material (*)

20 Cover Material SS

21 Mounting Side Mounted

22 Type Guided wave Radar

SENSOR 23 Insertion Depth -

24 Material SS

25 Indicator Required

26 Output 2 wires, 4..20 mA

27 Reliability -

TRANSMITTER 28 Mounting Integral

29 Power Supply Loop Powered 24 VDC

30 Enclosure Class -

31 Cable Gland -

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 28/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

DUAL CHAMBER LEVEL GAUGE/TRANSMITTER DATASHEET


1 Tag Number LG4050/LG4051/LIT4050

2 Service Level Gauge/Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Location MBD-4100 1ST STAGE SEPARATOR

5 Area Classification ZONE 2

6 Fluid MULTIPHASE CRUDE OIL

7 Min Operating Max Design

8 Temperature (C) - - - -
PROCESS
9 Pressure (Barg) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Specific Gravity -

12 Viscosity -

13 Instrument Type Dual chamber

14 Gauge Type Gauge Quantity Glass 2

15 Connections Center to Center Distance - -

16 Tube Material Glass

GAUGE 17 Size 2"


End Connection
18 Type Flanged 2", 600# RTJ

19 Body Material (*)

20 Cover Material SS

21 Mounting Side Mounted

22 Type Guided wave Radar

SENSOR 23 Insertion Depth -

24 Material SS

25 Indicator Required

26 Output 2 wires, 4..20 mA

27 Reliability -

TRANSMITTER 28 Mounting Integral

29 Power Supply Loop Powered 24 VDC

30 Enclosure Class -

31 Cable Gland -

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 29/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSHH4050 LSLL4051

2 Service Pressure Switch Low Low Pressure Switch High High

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Location MBD-4100 1ST STAGE SEPARATOR

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

8 Pressure (Barg) - - - -
PROCESS
9 Temperature (C) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point - -

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Class 2" 600#


Process Connection
19 Size 1/2" NPTM

SWITCH 20 Body Material SS

21 Float Material SS

22 Enclosure Class Ingress Protection - IP54

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 30/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSLL4050

2 Service Pressure Switch Low Low

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Location MBD-4100 1ST STAGE SEPARATOR

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

8 Pressure (Barg) - - - -
PROCESS
9 Temperature (C) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point -

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Class 2" 600#


Process Connection
19 Size 1/2" NPTM

SWITCH 20 Body Material SS

21 Float Material SS

22 Enclosure Class Ingress Protection - IP54

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 31/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SWITCH DATASHEET


1 Tag Number PSLL4050 PSHH4050

2 Service Pressure Switch Low Low Pressure Switch High High

GENERAL 3 Line Number P&ID Number NA AR1602.04-PRO-DRW-002-SH 4/21

4 Equipment Number Location MBD4100 1ST STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Switch Type SPDT/SNAP

13 Set point (Barg) - -

14 Setting Trip Factory Set

15 Operating Range 0..100 Bar

16 Class 600#
Process Connection
17 Size 1/2" NPTM

18 Housing Material Aluminum

SWITCH 19 Enclosure Class Ingress Protection - IP54

20 Packing Material 2x1.5 mm

21 Power supply 24 VDC

22 Contact Arrangement 2NO/2NC

23 Cable Gland M20x1.5

24 External Adjustment Required

25 Accuracy (*)

26 Mounting On pipe

27 Manifold 2 Valve Manifold

28 Manifold Material SS

MANIFOLD 29 Inlet 1/2" NPTF

30 Manifold End Connections Outlet 1/2" NPTM

31 Drain 1/4" NPT

32 Local Display Not Required

33 Mounting Brackets Required


OPTIONS
34 Sun Shade Not Required

35 LED Indication Not Required

36 Certificate of Conformity Required

37 ATEX Certificate Not Required

38 Sour Service Certificate Not Required

MISCELLANEOUS 39 SIL Certificate Not Required

40 Leakage Test Not Required

41 Hydrostatic Test Not Required

42 Spare Parts Required for Construction, Commissioning and Start-up

43 Vendor Manufacturer (*) (*)

PURCHASE 44 Purchase Order Number Serial Number (*) (*)

45 Model Number (*)

Page 32/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number PIT4050

2 Service Pressure Indicator Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.04-PRO-DRW-002-SH 4/21

4 Equipment Number MBD4100

5 Location / Area ZONE 2

6 Area Classification ZONE 2

7 Fluid Multiphase Crude Oil

8 Min Operating Max Design


PROCESS
9 Pressure (Barg) - - - -
CONDITIONS
10 Temperature (C) - - - -

11 Mass Density (Kg/m3) -

12 Instrument Range 0..100 Bar

13 Element Type Diaphragm


ELEMENT
14 Element Material SS

15 Number of wires 2 wire sensor

16 Indicator Scale LCD Type Required (*)

17 Material SS

18 Process Connection Electrical Connection 1/2" NPT M20x1.5

TRANSMITTER 19 Power Supply Load Resistance 24 VDC Loop Powered (*)

20 Packing Material 4..20 mA HART

21 ATEX Rating Ingress Protection #REF! IP54

22 Accuracy Repeatability 0.05% (*)

23 Manifold 2-way valve : Isolation + vent + Drain


MANIFOLD
24 Size and Rating Inlet 1/2" NPTM x Outlet 1/2" NPTM ; Drain 1/4" NPTF ANSI Class 3000#

25 Certificate of Conformity Required

26 ATEX Certificate -

27 Sour Service Certificate Not Required

MISCELLANEOUS 28 SIL Certificate Not Required

29 Leakage Test Not Required

30 Hydrostatic Test Not Required

31 Spare Parts Required for Construction, Commissioning and Start-up

32 Vendor Manufacturer (*) (*)

PURCHASE 33 Purchase Order Number Serial Number (*) (*)

34 Model Number (*)

Page 33/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SAFETY VALVE


1 Tag Number PSV4050

2 Service Pressure Safety Valve

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Equipment Designation MBD4100 1ST STAGE SEPARATOR

5 Location / Area ZONE 2

6 Area Classification ZONE 2

7 Fluid Two phase Crude Oil

8 Min Operating Max Design

9 Pressure (Barg) - - - -

10 Temperature (C) - - - -

11 Set Pressure (Barg) -

12 Back Pressure (Barg) -

13 Specific Heat Ratio (Cp/Cv) -

PROCESS 14 Mass Density (Kg/m3) -


CONDITIONS 15 Molecular Weight -

16 Compressibility Factor Z -

17 Relieving Temperature (C)

18 Flowrate to Release (Kg/h) -

19 Medium to release -

20 Caculated Orifice Area -

21 Selected Orifice Area -

22 Rated Relief Capacity (Kg/h) -

23 Design Basis API 520

24 Valve Type Conventional

25 Relief Case Blocked Outlet

26 Body Material CS

27 Ingress Protection Class IP54


TECHNICAL DATA
28 Trim Material SS

29 Spring Material SS

30 Type of connection Flanged

31 Inlet Size Inlet Class - -

32 Outlet Size Outlet Class - -

OTHER 33 Fire Safe as per API 6FA

34 Certificate of Conformity Required

35 ATEX Certificate -

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Not Required

38 Leakage Test Not Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Model Number (*)

Page 34/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SAFETY VALVE


1 Tag Number PSV4051

2 Service Pressure Safety Valve

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Equipment Designation MBD4100 1ST STAGE SEPARATOR

5 Location / Area ZONE 2

6 Area Classification ZONE 2

7 Fluid Two phase Crude Oil

8 Min Operating Max Design

9 Pressure (Barg) - - - -

10 Temperature (C) - - - -

11 Set Pressure (Barg) -

12 Back Pressure (Barg) -

13 Specific Heat Ratio (Cp/Cv) -

PROCESS 14 Mass Density (Kg/m3) -


CONDITIONS 15 Molecular Weight -

16 Compressibility Factor Z -

17 Relieving Temperature (C)

18 Flowrate to Release (Kg/h) -

19 Medium to release -

20 Caculated Orifice Area -

21 Selected Orifice Area -

22 Rated Relief Capacity (Kg/h) -

23 Design Basis API 520

24 Valve Type Conventional

25 Relief Case Blocked Outlet

26 Body Material CS

27 Ingress Protection Class IP54


TECHNICAL DATA
28 Trim Material SS

29 Spring Material SS

30 Type of connection Flanged

31 Inlet Size Inlet Class - -

32 Outlet Size Outlet Class - -

OTHER 33 Fire Safe as per API 6FA

34 Certificate of Conformity Required

35 ATEX Certificate -

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Not Required

38 Leakage Test Not Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Model Number (*)

Page 35/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

SHUTDOWN VALVE DATASHEET


1 Tag Number ESDV4050

2 Service Shutdown Valve

GENERAL 3 Line Number P&ID Number 6"-PF-C31X-4050 AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Location - 1ST STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design


PROCESS
8 Pressure (Barg) - - - -
DATA
9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Type Ball Valve

12 Body Size Port Size 6" Full Bore

13 Maximum Pressure Maximum Temperature (*) (*)

14 Body Material CS

15 Fire Safe YES


VALVE BODY
16 Class Size Flanged RTJ 600# 6"
CHARACTERISTICS Process Connection Type
17 Downstream Flanged 6" 600# RTJ

18 Type of Bonnet Bolted

19 Lubrication Lube Type Required (*)

20 Packing Material PTFE

21 Bolting Material CS

22 Type Trunnion Mounted

23 Size Rated Travel (*) (*)

TRIM 24 Service ON / OFF Valve


CHARACTERISTICS 25 Ball Material SS

26 Seat Insert PTFE

27 Stem Material SS

28 Type Pneumatic and Pinion Spring Return

29 Size (*)

30 Fail Position Closed


ACTUATOR
31 Max. Operating Pressure Max. Allowable Pressure (*) (*)
CHARACTERISTICS
32 Stroking Time Torque 10 sec (*)

33 Handwheel Not Required

34 Safety Factor 100%

35 Tag Number SDY4050

36 Type 3-way Valve

37 Input Signal 24 VDC

SOLENOID VALVE 38 Fluid Instrument Air

39 SIL Enclosure/ATEX Class - IP 66 -

40 Body Size Body Material (*) (*)

41 Connection Type Cable Gland (*) M20x1.5

42 Quantity Type 2 Proximity Switch

43 Tag Number ZSC4050 ZSO4050


LIMIT SWITCH
44 Designation Closed Open

45 Enclosure Class Cable Gland - M20x1.5

UTILITIES 46 Fluid Pressure Instrument Air -

49 ATEX Certificate Sour Service Certificate Required Required

50 SIL Certificate Leakage Test Required Required

MISCELLANEOUS 51 Spare Parts Required for Construction, Commissioning and Start-up

52 Vendor Manufacturer (*) (*)

53 Purchase Order Number Serial Number (*) (*)

Page 36/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW4053

2 Service Temperature Indicator

GENERAL 3 Line Number P&ID Number 6"-PF-C31X-4050 AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Location - 1ST STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Type Bi-Metal

13 Range -

14 Stem Type Threaded

15 Stem Material SS

16 Stem Length Stem Diameter (*) (*)


THERMOMETER
17 Dial Size Dial Color 150 mm White

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP54

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7"

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 37/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI4051

2 Service Pressure Indicator

GENERAL 3 Line Number P&ID Number 4"-PG-B31X-4054 AR1602.03-PRO-DRW-008 SH 4/21

4 Equipment Number Location - 1ST STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid GAS

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg) - - - -

9 Temperature (C) - - - -

10 Range -

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS

GAUGE DETAILS 15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

17 Fill Fluid NA

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP54

21 Connection Flanged

22 Bottom Housing Material SS

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge Threaded 1/2" NPT

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 38/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number TIT/TW4052

2 Service Temperature Indicator Transmitter

GENERAL 3 Line Number P&ID Number 4"-PG-B31X-4054 AR1602.03-PRO-DRW-008 SH 4/21

4 Equipment Number Location - 1ST STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Measuring Element RTD

13 Range -

14 Material SS

ELEMENT 15 Mounting Thermowell Mounted

16 Number of Wires 3 Wires

17 Sensor Connection 1/2" NPT

18 Diameter (*)

19 Type HART Transmitter

20 Packing Material 3 Wire Pt 100

21 Nb of Wires 2 Wire Transmitter

22 Enclosure Class Ingress Protection #REF! IP54

23 Local Indicator LCD Display Required

TRANSMITTER 24 Power Supply 24 VDC Loop Powered

25 Level 4..20 mA HART


Output Signal
26 Accuracy Class 1

27 Cable Cable Gland 2x1.5 mm M20x1.5

28 Enclosure Material SS

29 Nameplate Required, Engraved with SS tag plate

30 Material 316 SS

31 Process Connection Flanged 600 RTJ 1 1/2"

32 Sensor Connection 1/2" NPT

THERMOWELL 33 Calculated Immersion Length 7".58

34 Selected Immersion Length (*)

35 External Diameter (*)

36 Construction Type Tapered

37 Certificate of Conformity Required

38 ATEX Certificate Required

39 Sour Service Certificate Not Required

MISCELLANEOUS 40 SIL Certificate Not Required

41 Leakage Test Not Required

42 Hydrostatic Test Not Required

43 Spare Parts Required for Construction, Commissioning and Start-up

44 Vendor Manufacturer (*) (*)

PURCHASE 45 Purchase Order Number Serial Number (*) (*)

46 Model Number (*)

Page 39/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

FLOW TRANSMITTER DATASHEET


1 Tag Number FT4052

2 Service Flow Transmitter

GENERAL 3 Line Number P&ID Number 4"-PG-B31X-4054 AR1602.03-PRO-DRW-008 SH 4/21

4 Equipment Number Location - 1ST STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid GAS

7 Min Operating Max Design

8 Temperature (C) - - - -

PROCESS 9 Pressure (Barg) - - - -


DATA 10 Flowrate (Kg/h) -

11 Density (Kg/m3) -

12 Molecular Weight -

13 Viscosity -

14 Meter Type Integral Orifice Plate Flowmeter

15 Orifice Shape Square Edged

16 Bore Diameter (*)


METER
17 Upstream length Downstream Length 10 D 5D

18 Size & Type 4" RF


End Connections
19 Class 300#

20 Power Supply 24 VDC Loop Powered

21 Output Signal 4..20 mA


TRANSMITTER
22 Enclosure Class -

23 Cable Gland -

24 Manifold 5-valve manifold (2x1/4" Drain Screws + 2x1/4" Isolation Screws / 1x1/4" Equalizer)

25 Manifold Material SS

ACCESSORIES 26 Inlet 2x1/2" NPTM


Manifold End Connections
27 Outlet 2x1/2" NPTM

28 LCD Indicator Not Required

29 Certificate of Conformity Required

30 ATEX Certificate -

31 Sour Service Certificate Not Required

MISCELLANEOUS 32 SIL Certificate Not Required

33 Leakage Test Not Required

34 Hydrostatic Test Required

35 Spare Parts Required for Construction, Commissioning and Start-up

36 Vendor Manufacturer (*) (*)

PURCHASE 37 Purchase Order Number Serial Number (*) (*)

38 Model Number (*)

Page 40/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number PCV4050

2 Service Pressure Control Valve

GENERAL 3 Line Number P&ID Number 2"-PG-B31X-4060 AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Location - 1ST STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Gas

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg)

16 Max. Vapor Pressure (Bara)

17 Cp/Cv

18 Inlet
Line Size & Shedule
19 Outlet

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Gate

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position FAIL TO CLOSE

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 24VDC Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 41/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number LCV4050

2 Service Level Control Valve

GENERAL 3 Line Number P&ID Number 2"-PW-C31X-4056 AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Location - 1ST STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Water

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

17 Cp/Cv

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Ball

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position FAIL TO CLOSE

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 24VDC Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 42/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number PCV4051

2 Service Pressure Control Valve

GENERAL 3 Line Number P&ID Number XX"-PG-C31X-4053 AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Location - 1ST STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Gas

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

17 Cp/Cv

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Gate

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position FAIL TO CLOSE

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 24VDC Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 43/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number LCV4051

2 Service Level Control Valve

GENERAL 3 Line Number P&ID Number 3"-PO-C31X-4058 AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Location - 1ST STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid CRUDE OIL

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

17 Cp/Cv

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Ball

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position FAIL TO CLOSE

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 24VDC Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 44/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

FLOW TRANSMITTER DATASHEET


1 Tag Number FT4051

2 Service Flow Transmitter

GENERAL 3 Line Number P&ID Number 3"-PO-C31X-4058 AR1602.03-PRO-DRW-008 SH 4/21

4 Equipment Number Location - 1ST STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Crude Oil

7 Min Operating Max Design

8 Temperature (C) - - - -

PROCESS 9 Pressure (Barg) - - - -


DATA 10 Flowrate (Kg/h) -

11 Density (Kg/m3) -

12 Molecular Weight -

13 Viscosity -

14 Meter Type Turbine

15 Upstream length Downstream Length 10 D 5D

16 Size & Type 3" RTJ


METER End Connections
17 Class 600#

18 Rotor Blades (*)


Material of Construction
19 Body (*)

20 Power Supply 24 VDC Loop Powered

21 Output Signal 4..20 mA

TRANSMITTER 22 Enclosure Class -

23 Cable Gland -

24 Totalizer Required

24 Certificate of Conformity Required

25 ATEX Certificate -

26 Sour Service Certificate Not Required

MISCELLANEOUS 27 SIL Certificate Not Required

28 Leakage Test Not Required

29 Hydrostatic Test Required

30 Spare Parts Required for Construction, Commissioning and Start-up

31 Vendor Manufacturer (*) (*)

PURCHASE 32 Purchase Order Number Serial Number (*) (*)

33 Model Number (*)

Page 45/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

FLOW TRANSMITTER DATASHEET


1 Tag Number FT4053

2 Service Flow Transmitter

GENERAL 3 Line Number P&ID Number 2"-PW-C31X-4056 AR1602.03-PRO-DRW-008 SH 4/21

4 Equipment Number Location - 1ST STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Crude Oil

7 Min Operating Max Design

8 Temperature (C) - - - -

PROCESS 9 Pressure (Barg) - - - -


DATA 10 Flowrate (Kg/h) -

11 Density (Kg/m3) -

12 Molecular Weight -

13 Viscosity -

14 Meter Type Turbine

15 Upstream length Downstream Length 10 D 5D

16 Size & Type 2" RTJ


METER End Connections
17 Class 600#

18 Rotor Blades (*)


Material of Construction
19 Body (*)

20 Power Supply 24 VDC Loop Powered

21 Output Signal 4..20 mA

TRANSMITTER 22 Enclosure Class -

23 Cable Gland -

24 Totalizer Required

24 Certificate of Conformity Required

25 ATEX Certificate -

26 Sour Service Certificate Not Required

MISCELLANEOUS 27 SIL Certificate Not Required

28 Leakage Test Not Required

29 Hydrostatic Test Required

30 Spare Parts Required for Construction, Commissioning and Start-up

31 Vendor Manufacturer (*) (*)

PURCHASE 32 Purchase Order Number Serial Number (*) (*)

33 Model Number (*)

Page 46/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

SHUTDOWN VALVE DATASHEET


1 Tag Number ESDV4100

2 Service Shutdown Valve

GENERAL 3 Line Number P&ID Number 4"-PF-B31X-4100 AR1602.03-PRO-DRW-008-SH 5/21

4 Equipment Number Location - 2ND STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design


PROCESS
8 Pressure (Barg) - - - -
DATA
9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Type Ball Valve

12 Body Size Port Size 4" Full Bore

13 Maximum Pressure Maximum Temperature (*) (*)

14 Body Material CS

15 Fire Safe YES


VALVE BODY
16 Class Size Flanged RF 300# 4"
CHARACTERISTICS Process Connection Type
17 Downstream Flanged 6" 600# RTJ

18 Type of Bonnet Bolted

19 Lubrication Lube Type Required (*)

20 Packing Material PTFE

21 Bolting Material CS

22 Type Trunnion Mounted

23 Size Rated Travel (*) (*)

TRIM 24 Service ON / OFF Valve


CHARACTERISTICS 25 Ball Material SS

26 Seat Insert PTFE

27 Stem Material SS

28 Type Pneumatic and Pinion Spring Return

29 Size (*)

30 Fail Position Closed


ACTUATOR
31 Max. Operating Pressure Max. Allowable Pressure (*) (*)
CHARACTERISTICS
32 Stroking Time Torque 10 sec (*)

33 Handwheel Not Required

34 Safety Factor 100%

35 Tag Number SDY4100

36 Type 3-way Valve

37 Input Signal 24 VDC

SOLENOID VALVE 38 Fluid Instrument Air

39 SIL Enclosure/ATEX Class - IP54 -

40 Body Size Body Material (*) (*)

41 Connection Type Cable Gland (*) M20x1.5

42 Quantity Type 2 Proximity Switch

43 Tag Number ZSC4100 ZSO4100


LIMIT SWITCH
44 Designation Closed Open

45 Enclosure Class Cable Gland - M20x1.5

UTILITIES 46 Fluid Pressure Instrument Air -

49 ATEX Certificate Sour Service Certificate Required Required

50 SIL Certificate Leakage Test Required Required

MISCELLANEOUS 51 Spare Parts Required for Construction, Commissioning and Start-up

52 Vendor Manufacturer (*) (*)

53 Purchase Order Number Serial Number (*) (*)

Page 47/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW4100

2 Service Temperature Indicator

GENERAL 3 Line Number P&ID Number 4"-PF-B31X-4100 AR1602.03-PRO-DRW-008-SH 5/21

4 Equipment Number Location - 2ND STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Type Bi-Metal

13 Range -

14 Stem Type Threaded

15 Stem Material SS

16 Stem Length Stem Diameter (*) (*)


THERMOMETER
17 Dial Size Dial Color 150 mm White

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP54

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7"

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 48/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SAFETY VALVE


1 Tag Number PSV4100

2 Service Pressure Safety Valve

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008-SH 5/21

4 Equipment Number Equipment Designation MBD4200 2ND STAGE SEPARATOR

5 Location / Area -

6 Area Classification ZONE 2

7 Fluid VAPOUR

8 Min Operating Max Design

9 Pressure (Barg) - - - -

10 Temperature (C) - - - -

11 Set Pressure (Barg) -

12 Back Pressure (Barg) -

13 Specific Heat Ratio (Cp/Cv) -

PROCESS 14 Mass Density (Kg/m3) -


CONDITIONS 15 Molecular Weight -

16 Compressibility Factor Z -

17 Relieving Temperature (C)

18 Flowrate to Release (Kg/h) -

19 Medium to release -

20 Caculated Orifice Area -

21 Selected Orifice Area -

22 Rated Relief Capacity (Kg/h) -

23 Design Basis API 520

24 Valve Type Conventional

25 Relief Case CONTROL VALVE FAILURE

26 Body Material CS

27 Ingress Protection Class IP54


TECHNICAL DATA
28 Trim Material SS

29 Spring Material SS

30 Type of connection Flanged

31 Inlet Size Inlet Class - -

32 Outlet Size Outlet Class - -

OTHER 33 Fire Safe as per API 6FA

34 Certificate of Conformity Required

35 ATEX Certificate Required

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Not Required

38 Leakage Test Not Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Model Number (*)

Page 49/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SAFETY VALVE


1 Tag Number PSV101

2 Service Pressure Safety Valve

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008-SH 5/21

4 Equipment Number Equipment Designation MBD4200 2ND STAGE SEPARATOR

5 Location / Area -

6 Area Classification ZONE 2

7 Fluid VAPOUR

8 Min Operating Max Design

9 Pressure (Barg) - - - -

10 Temperature (C) - - - -

11 Set Pressure (Barg) -

12 Back Pressure (Barg) -

13 Specific Heat Ratio (Cp/Cv) -

PROCESS 14 Mass Density (Kg/m3) -


CONDITIONS 15 Molecular Weight -

16 Compressibility Factor Z -

17 Relieving Temperature (C)

18 Flowrate to Release (Kg/h) -

19 Medium to release -

20 Caculated Orifice Area -

21 Selected Orifice Area -

22 Rated Relief Capacity (Kg/h) -

23 Design Basis API 520

24 Valve Type Conventional

25 Relief Case CONTROL VALVE FAILURE

26 Body Material CS

27 Ingress Protection Class IP54


TECHNICAL DATA
28 Trim Material SS

29 Spring Material SS

30 Type of connection Flanged

31 Inlet Size Inlet Class - -

32 Outlet Size Outlet Class - -

OTHER 33 Fire Safe as per API 6FA

34 Certificate of Conformity Required

35 ATEX Certificate Required

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Not Required

38 Leakage Test Not Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Model Number (*)

Page 50/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number PCV4100

2 Service Pressure Control Valve

GENERAL 3 Line Number P&ID Number 2"-PG-B31X-4103 AR1602.03-PRO-DRW-008-SH 5/21

4 Equipment Number Location - 2ND STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Gas

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

17 Cp/Cv

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Gate

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position FAIL TO CLOSE

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 4..20mA Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 51/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number LCV4101

2 Service Level Control Valve

GENERAL 3 Line Number P&ID Number 3"-PO-B31X-4108 AR1602.03-PRO-DRW-008-SH 5/21

4 Equipment Number Location - 2ND STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Water

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

17 Cp/Cv -

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Ball

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position FAIL TO CLOSE

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 4..20mA Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 52/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number PCV4100

2 Service Pressure Control Valve

GENERAL 3 Line Number P&ID Number 2"-PG-B31X-4104 AR1602.03-PRO-DRW-008-SH 5/21

4 Equipment Number Location - 2ND STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Gas

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

17 Cp/Cv

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Gate

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position FAIL TO CLOSE

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 4..20mA Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 53/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number LCV4100

2 Service Level Control Valve

GENERAL 3 Line Number P&ID Number 2"-PW-B31X-4106 AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Location - 2ND STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid CRUDE OIL

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

17 Cp/Cv

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Ball

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position FAIL TO CLOSE

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 4..20mA Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 54/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW4101 TI/TW4103

2 Service Temperature Indicator

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 5/21

4 Equipment Number Location MBD-4200 2ND STAGE SEPARATOR

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Type Bi-Metal

13 Range -

14 Stem Type Threaded

15 Stem Material SS

16 Stem Length Stem Diameter (*) (*)


THERMOMETER
17 Dial Size Dial Color 150 mm White

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP54

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7"

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 55/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

DUAL CHAMBER LEVEL GAUGE/TRANSMITTER DATASHEET


1 Tag Number LG4100/LG 4101/LIT4100

2 Service Level Gauge/Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 5/21

4 Equipment Number Location MBD-4200 2ND STAGE SEPARATOR

5 Area Classification ZONE 2

6 Fluid MULTIPHASE CRUDE OIL

7 Min Operating Max Design

8 Temperature (C) - - - -
PROCESS
9 Pressure (Barg) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Specific Gravity -

12 Viscosity -

13 Instrument Type Dual chamber

14 Gauge Type Gauge Quantity Glass 2

15 Connections Center to Center Distance - -

16 Tube Material Glass

GAUGE 17 Size 2"


End Connection
18 Type Flanged 2", 300# RF

19 Body Material (*)

20 Cover Material SS

21 Mounting Side Mounted

22 Type Guided wave Radar

SENSOR 23 Insertion Depth -

24 Material SS

25 Indicator Required

26 Output 2 wires, 4..20 mA

27 Reliability -

TRANSMITTER 28 Mounting Integral

29 Power Supply Loop Powered 24 VDC

30 Enclosure Class -

31 Cable Gland -

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 56/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSHH4100 LSLL4101

2 Service Pressure Switch Low Low Pressure Switch High High

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 5/21

4 Equipment Number Location MBD4200 2ND STAGE SEPARATOR

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

8 Pressure (Barg) - - - -
PROCESS
9 Temperature (C) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point - -

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Class 2" Flanged RF 300#


Process Connection
19 Size 1/2" NPTM

SWITCH 20 Body Material SS

21 Float Material SS

22 Enclosure Class Ingress Protection - IP54

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 57/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSLL4100

2 Service Pressure Switch Low Low

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 5/21

4 Equipment Number Location MBD4200 2ND STAGE SEPARATOR

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

8 Pressure (Barg) - - - -
PROCESS
9 Temperature (C) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point -

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Class 2" 300#


Process Connection
19 Size 1/2" NPTM

SWITCH 20 Body Material SS

21 Float Material SS

22 Enclosure Class Ingress Protection - IP54

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 58/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SWITCH DATASHEET


1 Tag Number PSLL4100 PSHH4100

2 Service Pressure Switch Low Low Pressure Switch High High

GENERAL 3 Line Number P&ID Number NA AR1602.04-PRO-DRW-002-SH 5/21

4 Equipment Number Location MBD4200 2ND STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid GAS

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Switch Type SPDT/SNAP

13 Set point (Barg) - -

14 Setting Trip Factory Set

15 Operating Range -

16 Class 300#
Process Connection
17 Size 1/2" NPTM

18 Housing Material Aluminum

SWITCH 19 Enclosure Class Ingress Protection - IP54

20 Packing Material 2x1.5 mm

21 Power supply 24 VDC

22 Contact Arrangement 2NO/2NC

23 Cable Gland M20x1.5

24 External Adjustment Required

25 Accuracy (*)

26 Mounting On pipe

27 Manifold 2 Valve Manifold

28 Manifold Material SS

MANIFOLD 29 Inlet 1/2" NPTF

30 Manifold End Connections Outlet 1/2" NPTM

31 Drain 1/4" NPT

32 Local Display Not Required

33 Mounting Brackets Required


OPTIONS
34 Sun Shade Not Required

35 LED Indication Not Required

36 Certificate of Conformity Required

37 ATEX Certificate Not Required

38 Sour Service Certificate Not Required

MISCELLANEOUS 39 SIL Certificate Not Required

40 Leakage Test Not Required

41 Hydrostatic Test Not Required

42 Spare Parts Required for Construction, Commissioning and Start-up

43 Vendor Manufacturer (*) (*)

PURCHASE 44 Purchase Order Number Serial Number (*) (*)

45 Model Number (*)

Page 59/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number PIT4100

2 Service Pressure Indicator Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.04-PRO-DRW-002-SH 5/21

4 Equipment Number MBD4200

5 Location / Area -

6 Area Classification ZONE 2

7 Fluid GAS

8 Min Operating Max Design


PROCESS
9 Pressure (Barg) - - - -
CONDITIONS
10 Temperature (C) - - - -

11 Mass Density (Kg/m3) -

12 Instrument Range -

13 Element Type Diaphragm


ELEMENT
14 Element Material SS

15 Number of wires 2 wire sensor

16 Indicator Scale LCD Type Required (*)

17 Material SS

18 Process Connection Electrical Connection 1/2" NPT M20x1.5

TRANSMITTER 19 Power Supply Load Resistance 24 VDC Loop Powered (*)

20 Packing Material 4..20 mA HART

21 ATEX Rating Ingress Protection #REF! IP54

22 Accuracy Repeatability 0.05% (*)

23 Manifold 2-way valve : Isolation + vent + Drain


MANIFOLD
24 Size and Rating Inlet 1/2" NPTM x Outlet 1/2" NPTM ; Drain 1/4" NPTF ANSI Class 3000#

25 Certificate of Conformity Required

26 ATEX Certificate -

27 Sour Service Certificate Not Required

MISCELLANEOUS 28 SIL Certificate Not Required

29 Leakage Test Not Required

30 Hydrostatic Test Not Required

31 Spare Parts Required for Construction, Commissioning and Start-up

32 Vendor Manufacturer (*) (*)

PURCHASE 33 Purchase Order Number Serial Number (*) (*)

34 Model Number (*)

Page 60/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

DUAL CHAMBER LEVEL GAUGE/TRANSMITTER DATASHEET


1 Tag Number LG4102/LIT4101

2 Service Level Gauge/Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 5/21

4 Equipment Number Location MBD4200 2ND STAGE SEPARATOR

5 Area Classification ZONE 2

6 Fluid MULTIPHASE CRUDE OIL

7 Min Operating Max Design

8 Temperature (C) - - - -
PROCESS
9 Pressure (Barg) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Specific Gravity -

12 Viscosity -

13 Instrument Type Dual chamber

14 Gauge Type Glass

15 Connections Center to Center Distance -

16 Tube Material Glass

GAUGE 17 Size 2"


End Connection
18 Type Flanged 2", 300# RF

19 Body Material (*)

20 Cover Material SS

21 Mounting Side Mounted

22 Type Guided wave Radar

SENSOR 23 Insertion Depth -

24 Material SS

25 Indicator Required

26 Output 2 wires, 4..20 mA

27 Reliability -

TRANSMITTER 28 Mounting Integral

29 Power Supply Loop Powered 24 VDC

30 Enclosure Class -

31 Cable Gland -

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 61/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number TIT/TW4102

2 Service Temperature Indicator Transmitter

GENERAL 3 Line Number P&ID Number 2"-PG-B31X-4104 AR1602.03-PRO-DRW-008 SH 5/21

4 Equipment Number Location - 2ND STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid GAS

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Measuring Element RTD

13 Range -

14 Material SS

ELEMENT 15 Mounting Thermowell Mounted

16 Number of Wires 3 Wires

17 Sensor Connection 1/2" NPT

18 Diameter (*)

19 Type HART Transmitter

20 Packing Material 3 Wire Pt 100

21 Nb of Wires 2 Wire Transmitter

22 Enclosure Class Ingress Protection #REF! IP54

23 Local Indicator LCD Display Required

TRANSMITTER 24 Power Supply 24 VDC Loop Powered

25 Level 4..20 mA HART


Output Signal
26 Accuracy Class 1

27 Cable Cable Gland 2x1.5 mm M20x1.5

28 Enclosure Material SS

29 Nameplate Required, Engraved with SS tag plate

30 Material 316 SS

31 Process Connection Threaded 1/2"

32 Sensor Connection 1/2" NPT

THERMOWELL 33 Calculated Immersion Length 7"

34 Selected Immersion Length (*)

35 External Diameter (*)

36 Construction Type Tapered

37 Certificate of Conformity Required

38 ATEX Certificate Required

39 Sour Service Certificate Not Required

MISCELLANEOUS 40 SIL Certificate Not Required

41 Leakage Test Not Required

42 Hydrostatic Test Not Required

43 Spare Parts Required for Construction, Commissioning and Start-up

44 Vendor Manufacturer (*) (*)

PURCHASE 45 Purchase Order Number Serial Number (*) (*)

46 Model Number (*)

Page 62/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI4101

2 Service Pressure Indicator

GENERAL 3 Line Number P&ID Number 2"-PG-B31X-4104 AR1602.03-PRO-DRW-008 SH 5/21

4 Equipment Number Location - 2ND STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid GAS

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg) - - - -

9 Temperature (C) - - - -

10 Range -

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS

GAUGE DETAILS 15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

17 Fill Fluid NA

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP54

21 Connection Flanged

22 Bottom Housing Material SS

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge Threaded 1/2" NPT

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 63/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

SHUTDOWN VALVE DATASHEET


1 Tag Number SDV4150

2 Service Shutdown Valve

GENERAL 3 Line Number P&ID Number 4"-PF-A11X-4150 AR1602.03-PRO-DRW-008-SH 6/21

4 Equipment Number Location - 3RD STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design


PROCESS
8 Pressure (Barg) - - - -
DATA
9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Type Ball Valve

12 Body Size Port Size 4" Full Bore

13 Maximum Pressure Maximum Temperature (*) (*)

14 Body Material CS

15 Fire Safe YES


VALVE BODY
16 Class Size Flanged RF 150# 4"
CHARACTERISTICS Process Connection Type
17 Downstream Flanged 6" 600# RTJ

18 Type of Bonnet Bolted

19 Lubrication Lube Type Required (*)

20 Packing Material PTFE

21 Bolting Material CS

22 Type Trunnion Mounted

23 Size Rated Travel (*) (*)

TRIM 24 Service ON / OFF Valve


CHARACTERISTICS 25 Ball Material SS

26 Seat Insert PTFE

27 Stem Material SS

28 Type Pneumatic and Pinion Spring Return

29 Size (*)

30 Fail Position Closed


ACTUATOR
31 Max. Operating Pressure Max. Allowable Pressure (*) (*)
CHARACTERISTICS
32 Stroking Time Torque 10 sec (*)

33 Handwheel Not Required

34 Safety Factor 100%

35 Tag Number SDY4150

36 Type 3-way Valve

37 Input Signal 24 VDC

SOLENOID VALVE 38 Fluid Instrument Air

39 SIL Enclosure/ATEX Class - IP54 -

40 Body Size Body Material (*) (*)

41 Connection Type Cable Gland (*) M20x1.5

42 Quantity Type 2 Proximity Switch

43 Tag Number ZSC4150 ZSO4150


LIMIT SWITCH
44 Designation Closed Open

45 Enclosure Class Cable Gland - M20x1.5

UTILITIES 46 Fluid Pressure Instrument Air -

49 ATEX Certificate Sour Service Certificate Required Required

50 SIL Certificate Leakage Test Required Required

MISCELLANEOUS 51 Spare Parts Required for Construction, Commissioning and Start-up

52 Vendor Manufacturer (*) (*)

53 Purchase Order Number Serial Number (*) (*)

Page 64/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW4150

2 Service Temperature Indicator

GENERAL 3 Line Number P&ID Number 4"-PF-A11X-4150 AR1602.03-PRO-DRW-008-SH 6/21

4 Equipment Number Location - 3RD STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Type Bi-Metal

13 Range -

14 Stem Type Threaded

15 Stem Material SS

16 Stem Length Stem Diameter (*) (*)


THERMOMETER
17 Dial Size Dial Color 150 mm White

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP54

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7"

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 65/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SAFETY VALVE


1 Tag Number PSV4150

2 Service Pressure Safety Valve

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008-SH 6/21

4 Equipment Number Equipment Designation MBD4300 3RD STAGE SEPARATOR

5 Location / Area -

6 Area Classification ZONE 2

7 Fluid VAPOUR

8 Min Operating Max Design

9 Pressure (Barg) - - - -

10 Temperature (C) - - - -

11 Set Pressure (Barg) -

12 Back Pressure (Barg) -

13 Specific Heat Ratio (Cp/Cv) -

PROCESS 14 Mass Density (Kg/m3) -


CONDITIONS 15 Molecular Weight -

16 Compressibility Factor Z -

17 Relieving Temperature (C)

18 Flowrate to Release (Kg/h) -

19 Medium to release -

20 Caculated Orifice Area -

21 Selected Orifice Area -

22 Rated Relief Capacity (Kg/h) -

23 Design Basis API 520

24 Valve Type Conventional

25 Relief Case -

26 Body Material CS

27 Ingress Protection Class IP 54


TECHNICAL DATA
28 Trim Material SS

29 Spring Material SS

30 Type of connection Flanged

31 Inlet Size Inlet Class - -

32 Outlet Size Outlet Class - -

OTHER 33 Fire Safe as per API 6FA

34 Certificate of Conformity Required

35 ATEX Certificate -

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Not Required

38 Leakage Test Not Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Model Number (*)

Page 66/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SAFETY VALVE


1 Tag Number PSV4151

2 Service Pressure Safety Valve

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008-SH 6/21

4 Equipment Number Equipment Designation MBD4300 3RD STAGE SEPARATOR

5 Location / Area -

6 Area Classification ZONE 2

7 Fluid VAPOUR

8 Min Operating Max Design

9 Pressure (Barg) - - - -

10 Temperature (C) - - - -

11 Set Pressure (Barg) -

12 Back Pressure (Barg) -

13 Specific Heat Ratio (Cp/Cv) -

PROCESS 14 Mass Density (Kg/m3) -


CONDITIONS 15 Molecular Weight -

16 Compressibility Factor Z -

17 Relieving Temperature (C)

18 Flowrate to Release (Kg/h) -

19 Medium to release -

20 Caculated Orifice Area -

21 Selected Orifice Area -

22 Rated Relief Capacity (Kg/h) -

23 Design Basis API 520

24 Valve Type Conventional

25 Relief Case -

26 Body Material CS

27 Ingress Protection Class IP54


TECHNICAL DATA
28 Trim Material SS

29 Spring Material SS

30 Type of connection Flanged

31 Inlet Size Inlet Class - -

32 Outlet Size Outlet Class - -

OTHER 33 Fire Safe as per API 6FA

34 Certificate of Conformity Required

35 ATEX Certificate -

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Not Required

38 Leakage Test Not Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Model Number (*)

Page 67/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSLL4150

2 Service Pressure Switch Low Low

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 6/21

4 Equipment Number Location MBD4300 3RD STAGE SEPARATOR

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

8 Pressure (Barg) - - - -
PROCESS
9 Temperature (C) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point -

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Class 2" 300#


Process Connection
19 Size 1/2" NPTM

SWITCH 20 Body Material SS

21 Float Material SS

22 Enclosure Class Ingress Protection - IP54

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 68/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSHH4150 LSLL4151

2 Service Pressure Switch Low Low Pressure Switch High High

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 6/21

4 Equipment Number Location MBD4300 3RD STAGE SEPARATOR

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

8 Pressure (Barg) - - - -
PROCESS
9 Temperature (C) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point - -

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Class 2" Flanged RF 300#


Process Connection
19 Size 1/2" NPTM

SWITCH 20 Body Material SS

21 Float Material SS

22 Enclosure Class Ingress Protection - IP54

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 69/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SWITCH DATASHEET


1 Tag Number PSLL4150 PSHH4150

2 Service Pressure Switch Low Low Pressure Switch High High

GENERAL 3 Line Number P&ID Number NA AR1602.04-PRO-DRW-002-SH 6/21

4 Equipment Number Location MBD4300 3RD STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Switch Type SPDT/SNAP

13 Set point (Barg) - -

14 Setting Trip Factory Set

15 Operating Range -

16 Class 300#
Process Connection
17 Size 1/2" NPTM

18 Housing Material Aluminum

SWITCH 19 Enclosure Class Ingress Protection - IP54

20 Packing Material 2x1.5 mm

21 Power supply 24 VDC

22 Contact Arrangement 2NO/2NC

23 Cable Gland M20x1.5

24 External Adjustment Required

25 Accuracy (*)

26 Mounting On pipe

27 Manifold 2 Valve Manifold

28 Manifold Material SS

MANIFOLD 29 Inlet 1/2" NPTF

30 Manifold End Connections Outlet 1/2" NPTM

31 Drain 1/4" NPT

32 Local Display Not Required

33 Mounting Brackets Required


OPTIONS
34 Sun Shade Not Required

35 LED Indication Not Required

36 Certificate of Conformity Required

37 ATEX Certificate Not Required

38 Sour Service Certificate Not Required

MISCELLANEOUS 39 SIL Certificate Not Required

40 Leakage Test Not Required

41 Hydrostatic Test Not Required

42 Spare Parts Required for Construction, Commissioning and Start-up

43 Vendor Manufacturer (*) (*)

PURCHASE 44 Purchase Order Number Serial Number (*) (*)

45 Model Number (*)

Page 70/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW4151 TI/TW4152

2 Service Temperature Indicator

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 6/21

4 Equipment Number Location MBD4300 3RD STAGE SEPARATOR

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Type Bi-Metal

13 Range -

14 Stem Type Threaded

15 Stem Material SS

16 Stem Length Stem Diameter (*) (*)


THERMOMETER
17 Dial Size Dial Color 150 mm White

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP54

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7".58

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 71/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

DUAL CHAMBER LEVEL GAUGE/TRANSMITTER DATASHEET


1 Tag Number LG4152/LIT4151

2 Service Level Gauge/Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 6/21

4 Equipment Number Location MBD4300 3RD STAGE SEPARATOR

5 Area Classification ZONE 2

6 Fluid MULTIPHASE CRUDE OIL

7 Min Operating Max Design

8 Temperature (C) - - - -
PROCESS
9 Pressure (Barg) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Specific Gravity -

12 Viscosity -

13 Instrument Type Dual chamber

14 Gauge Type Glass

15 Connections Center to Center Distance -

16 Tube Material Glass

GAUGE 17 Size 2"


End Connection
18 Type Flanged RF 2", 300#

19 Body Material (*)

20 Cover Material SS

21 Mounting Side Mounted

22 Type Guided wave Radar

SENSOR 23 Insertion Depth -

24 Material SS

25 Indicator Required

26 Output 2 wires, 4..20 mA

27 Reliability -

TRANSMITTER 28 Mounting Integral

29 Power Supply Loop Powered 24 VDC

30 Enclosure Class -

31 Cable Gland -

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 72/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

DUAL CHAMBER LEVEL GAUGE/TRANSMITTER DATASHEET


1 Tag Number LG4150/LG 4151/LIT4150

2 Service Level Gauge/Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Location MBD4300 3RD STAGE SEPARATOR

5 Area Classification ZONE 2

6 Fluid MULTIPHASE CRUDE OIL

7 Min Operating Max Design

8 Temperature (C) - - - -
PROCESS
9 Pressure (Barg) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Specific Gravity -

12 Viscosity -

13 Instrument Type Dual chamber

14 Gauge Type Gauge Quantity Glass 2

15 Connections Center to Center Distance - -

16 Tube Material Glass

GAUGE 17 Size 2"


End Connection
18 Type Flanged RF 2", 300#

19 Body Material (*)

20 Cover Material SS

21 Mounting Side Mounted

22 Type Guided wave Radar

SENSOR 23 Insertion Depth -

24 Material SS

25 Indicator Required

26 Output 2 wires, 4..20 mA

27 Reliability -

TRANSMITTER 28 Mounting Integral

29 Power Supply Loop Powered 24 VDC

30 Enclosure Class -

31 Cable Gland -

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 73/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number PIT4150

2 Service Pressure Indicator Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.04-PRO-DRW-002-SH 6/21

4 Equipment Number MBD4300

5 Location / Area -

6 Area Classification ZONE 2

7 Fluid GAS

8 Min Operating Max Design


PROCESS
9 Pressure (Barg) - - - -
CONDITIONS
10 Temperature (C) - - - -

11 Mass Density (Kg/m3) -

12 Instrument Range

13 Element Type Diaphragm


ELEMENT
14 Element Material SS

15 Number of wires 2 wire sensor

16 Indicator Scale LCD Type Required (*)

17 Material SS

18 Process Connection Electrical Connection 1/2" NPT M20x1.5

TRANSMITTER 19 Power Supply Load Resistance 24 VDC Loop Powered (*)

20 Packing Material 4..20 mA HART

21 ATEX Rating Ingress Protection #REF! IP54

22 Accuracy Repeatability 0.05% (*)

23 Manifold 2-way valve : Isolation + vent + Drain


MANIFOLD
24 Size and Rating Inlet 1/2" NPTM x Outlet 1/2" NPTM ; Drain 1/4" NPTF ANSI Class 3000#

25 Certificate of Conformity Required

26 ATEX Certificate -

27 Sour Service Certificate Not Required

MISCELLANEOUS 28 SIL Certificate Not Required

29 Leakage Test Not Required

30 Hydrostatic Test Not Required

31 Spare Parts Required for Construction, Commissioning and Start-up

32 Vendor Manufacturer (*) (*)

PURCHASE 33 Purchase Order Number Serial Number (*) (*)

34 Model Number (*)

Page 74/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI4151

2 Service Pressure Indicator

GENERAL 3 Line Number P&ID Number 3"-PG-B31X-4152 AR1602.03-PRO-DRW-008 SH 6/21

4 Equipment Number Location - 3RD STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid GAS

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg) - - - -

9 Temperature (C) - - - -

10 Range -

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS

GAUGE DETAILS 15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

17 Fill Fluid NA

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP66

21 Connection Flanged

22 Bottom Housing Material SS

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge Threaded 1/2" NPT

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 75/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number TIT/TW4153

2 Service Temperature Indicator Transmitter

GENERAL 3 Line Number P&ID Number 3"-PG-B31X-4152 AR1602.03-PRO-DRW-008 SH 6/21

4 Equipment Number Location - 3RD STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid GAS

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Measuring Element RTD

13 Range -

14 Material SS

ELEMENT 15 Mounting Thermowell Mounted

16 Number of Wires 3 Wires

17 Sensor Connection 1/2" NPT

18 Diameter (*)

19 Type HART Transmitter

20 Packing Material 3 Wire Pt 100

21 Nb of Wires 2 Wire Transmitter

22 Enclosure Class Ingress Protection #REF! IP 54

23 Local Indicator LCD Display Required

TRANSMITTER 24 Power Supply 24 VDC Loop Powered

25 Level 4..20 mA HART


Output Signal
26 Accuracy Class 1

27 Cable Cable Gland 2x1.5 mm M20x1.5

28 Enclosure Material SS

29 Nameplate Required, Engraved with SS tag plate

30 Material 316 SS

31 Process Connection Threaded 1/2"

32 Sensor Connection 1/2" NPT

THERMOWELL 33 Calculated Immersion Length 7"

34 Selected Immersion Length (*)

35 External Diameter (*)

36 Construction Type Tapered

37 Certificate of Conformity Required

38 ATEX Certificate Required

39 Sour Service Certificate Not Required

MISCELLANEOUS 40 SIL Certificate Not Required

41 Leakage Test Not Required

42 Hydrostatic Test Not Required

43 Spare Parts Required for Construction, Commissioning and Start-up

44 Vendor Manufacturer (*) (*)

PURCHASE 45 Purchase Order Number Serial Number (*) (*)

46 Model Number (*)

Page 76/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number PCV4150

2 Service Pressure Control Valve

GENERAL 3 Line Number P&ID Number 3"-PG-B31X-4152 AR1602.03-PRO-DRW-008-SH 6/21

4 Equipment Number Location - 3RD STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Gas

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

17 Cp/Cv

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Gate

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position FAIL TO CLOSE

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 4..20mA Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 77/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number LCV4150

2 Service Level Control Valve

GENERAL 3 Line Number P&ID Number 2"-PW-A31X-4154 AR1602.03-PRO-DRW-008-SH 6/21

4 Equipment Number Location - 3RD STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Water

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

17 Cp/Cv

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Ball

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position FAIL TO CLOSE

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 4..20mA Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 78/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number PCV4151

2 Service Pressure Control Valve

GENERAL 3 Line Number P&ID Number X"-PG-A31X-4151 AR1602.03-PRO-DRW-008-SH 6/21

4 Equipment Number Location - 2ND STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid Gas

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

17 Cp/Cv

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Gate

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position FAIL TO CLOSE

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 4..20mA Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 79/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number LCV4151

2 Service Level Control Valve

GENERAL 3 Line Number P&ID Number 3"-PO-A31X-4153 AR1602.03-PRO-DRW-008-SH 6/21

4 Equipment Number Location - 3RD STAGE SEPARATOR AREA

5 Area Classification ZONE 2

6 Fluid CRUDE OIL

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -

PROCESS 13 Calculated Cv (*)


DATA 14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

17 Cp/Cv

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Ball

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position FAIL TO CLOSE

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 4..20mA Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 80/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SWITCH DATASHEET


1 Tag Number PSLL4650 PSHH4650

2 Service Pressure Switch Low Low Pressure Switch High High

GENERAL 3 Line Number X"-PO-A31X-4650 X"-PO-A31X-4651

4 Equipment Number P&ID Number NA AR1602.04-PRO-DRW-002-SH 18/21

5 Area Classification ZONE 2

6 Fluid CRUDE OIL

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Switch Type SPDT/SNAP

13 Set point (Barg) - -

14 Setting Trip Factory Set

15 Operating Range

16 Class 300#
Process Connection
17 Size 1/2" NPTM

18 Housing Material Aluminum

SWITCH 19 Enclosure Class Ingress Protection - IP54

20 Packing Material 2x1.5 mm

21 Power supply 24 VDC

22 Contact Arrangement 2NO/2NC

23 Cable Gland M20x1.5

24 External Adjustment Required

25 Accuracy (*)

26 Mounting On pipe

27 Manifold 2 Valve Manifold

28 Manifold Material SS

MANIFOLD 29 Inlet 1/2" NPTF

30 Manifold End Connections Outlet 1/2" NPTM

31 Drain 1/4" NPT

32 Local Display Not Required

33 Mounting Brackets Required


OPTIONS
34 Sun Shade Not Required

35 LED Indication Not Required

36 Certificate of Conformity Required

37 ATEX Certificate Not Required

38 Sour Service Certificate Not Required

MISCELLANEOUS 39 SIL Certificate Not Required

40 Leakage Test Not Required

41 Hydrostatic Test Not Required

42 Spare Parts Required for Construction, Commissioning and Start-up

43 Vendor Manufacturer (*) (*)

PURCHASE 44 Purchase Order Number Serial Number (*) (*)

45 Model Number (*)

Page 81/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SWITCH DATASHEET


1 Tag Number PSLL4651 PSHH4651

2 Service Pressure Switch Low Low Pressure Switch High High

GENERAL 3 Line Number X"-PO-A31X-4652 X"-PO-A31X-4653

4 Equipment Number P&ID Number NA AR1602.04-PRO-DRW-002-SH 18/21

5 Area Classification ZONE 2

6 Fluid CRUDE OIL

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Switch Type SPDT/SNAP

13 Set point (Barg) - -

14 Setting Trip Factory Set

15 Operating Range -

16 Class 300#
Process Connection
17 Size 1/2" NPTM

18 Housing Material Aluminum

SWITCH 19 Enclosure Class Ingress Protection - IP54

20 Packing Material 2x1.5 mm

21 Power supply 24 VDC

22 Contact Arrangement 2NO/2NC

23 Cable Gland M20x1.5

24 External Adjustment Required

25 Accuracy (*)

26 Mounting On pipe

27 Manifold 2 Valve Manifold

28 Manifold Material SS

MANIFOLD 29 Inlet 1/2" NPTF

30 Manifold End Connections Outlet 1/2" NPTM

31 Drain 1/4" NPT

32 Local Display Not Required

33 Mounting Brackets Required


OPTIONS
34 Sun Shade Not Required

35 LED Indication Not Required

36 Certificate of Conformity Required

37 ATEX Certificate Not Required

38 Sour Service Certificate Not Required

MISCELLANEOUS 39 SIL Certificate Not Required

40 Leakage Test Not Required

41 Hydrostatic Test Not Required

42 Spare Parts Required for Construction, Commissioning and Start-up

43 Vendor Manufacturer (*) (*)

PURCHASE 44 Purchase Order Number Serial Number (*) (*)

45 Model Number (*)

Page 82/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI4650

2 Service Pressure Indicator

GENERAL 3 Line Number P&ID Number X"-PO-A31X-4651 AR1602.03-PRO-DRW-008 SH 18/21

4 Equipment Number Location - -

5 Area Classification ZONE 2

6 Fluid CRUDE OIL

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg) - - - -

9 Temperature (C) - - - -

10 Range -

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS

GAUGE DETAILS 15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

17 Fill Fluid NA

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Ingress Protection IP54

21 Connection Flanged

22 Bottom Housing Material SS

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge Threaded 1/2" NPT

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 83/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI4651

2 Service Pressure Indicator

GENERAL 3 Line Number P&ID Number X"-PO-A31X-4653 AR1602.03-PRO-DRW-008 SH 18/21

4 Equipment Number Location - -

5 Area Classification ZONE 2

6 Fluid CRUDE OIL

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg) - - - -

9 Temperature (C) - - - -

10 Range -

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS

GAUGE DETAILS 15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

17 Fill Fluid NA

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Ingress Protection IP54

21 Connection Flanged

22 Bottom Housing Material SS

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge Threaded 1/2" NPT

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 84/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number PIT 4330

2 Service Pressure Indicator Transmitter

GENERAL 3 Line Number P&ID Number 4"-PG-C31X-4330 AR1602.04-PRO-DRW-008-SH 11/21

4 Equipment Number -

5 Location / Area EXPORT GAS HEADER

6 Area Classification ZONE 2

7 Fluid Multiphase Crude Oil

8 Min Operating Max Design


PROCESS
9 Pressure (Barg)
CONDITIONS
10 Temperature (C)

11 Mass Density (Kg/m3)

12 Instrument Range

13 Element Type Diaphragm


ELEMENT
14 Element Material SS

15 Number of wires 2 wire sensor

16 Indicator Scale LCD Type Required (*)

18 Process Connection Electrical Connection 1/2" NPT M20x1.5

19 Power Supply Load Resistance 24 VDC Loop Powered (*)


TRANSMITTER
20 Packing Material 4..20 mA HART

21 ATEX Rating Ingress Protection EEx d IIA T3 IP 54

22 Accuracy Repeatability 0.05% (*)

23 Manifold 2-way valve : Isolation + vent + Drain


MANIFOLD
24 Size and Rating Inlet 1/2" NPTM x Outlet 1/2" NPTM ; Drain 1/4" NPTF ANSI Class 3000#

25 Certificate of Conformity Required

26 ATEX Certificate Required

27 Sour Service Certificate Not Required

MISCELLANEOUS 28 SIL Certificate Not Required

29 Leakage Test Not Required

30 Hydrostatic Test Not Required

31 Spare Parts Required for Construction, Commissioning and Start-up

32 Vendor Manufacturer (*) (*)

PURCHASE 33 Purchase Order Number Serial Number (*) (*)

34 Model Number (*)

Page 85/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number PCV 4330

2 Service Pressure Control Valve

GENERAL 3 Line Number P&ID Number 4"-PG-C31X-4330 AR1602.03-PRO-DRW-008-SH 11/21

4 Equipment Number Location - EXPORT GAS HEADER

5 Area Classification ZONE 2

6 Fluid Gas

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -
PROCESS
13 Calculated Cv (*)
DATA
14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg)

16 Max. Vapor Pressure (Bara)

18 Inlet
Line Size & Shedule
19 Outlet

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Gate

23 Body Size Body Material - CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream - -

26 Type Downstream - -

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic -

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position -

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 24VDC Instrument Air

39 Air Supply Pressure Range -

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 86/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number PT 4330

2 Service Pressure Indicator Transmitter

GENERAL 3 Line Number P&ID Number 6"-PG-C31X-4331 AR1602.03-PRO-DRW-008-SH 11/21

4 Equipment Number -

5 Location / Area EXPORT GAS HEADER

6 Area Classification ZONE 2

7 Fluid Multiphase Crude Oil

8 Min Operating Max Design


PROCESS
9 Pressure (Barg)
CONDITIONS
10 Temperature (C)

11 Mass Density (Kg/m3)

12 Instrument Range

13 Element Type Diaphragm


ELEMENT
14 Element Material SS

15 Number of wires 2 wire sensor

16 Indicator Scale Not Required Not Required

18 Process Connection Electrical Connection 1/2" NPT M20x1.5

19 Power Supply Load Resistance 24 VDC Loop Powered (*)


TRANSMITTER
20 Packing Material 4..20 mA HART

21 ATEX Rating Ingress Protection EEx d IIA T3 IP 54

22 Accuracy Repeatability 0.05% (*)

23 Manifold 2-way valve : Isolation + vent + Drain


MANIFOLD
24 Size and Rating Inlet 1/2" NPTM x Outlet 1/2" NPTM ; Drain 1/4" NPTF ANSI Class 3000#

25 Certificate of Conformity Required

26 ATEX Certificate Required

27 Sour Service Certificate Not Required

MISCELLANEOUS 28 SIL Certificate Not Required

29 Leakage Test Not Required

30 Hydrostatic Test Not Required

31 Spare Parts Required for Construction, Commissioning and Start-up

32 Vendor Manufacturer (*) (*)

PURCHASE 33 Purchase Order Number Serial Number (*) (*)

34 Model Number (*)

Page 87/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSHH4400 LSLL4400

2 Service Level Switch High High Level Switch Low Low

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 14/21

4 Equipment Number Location - LP FLARE K.O DRUM

5 Area Classification ZONE 2

6 Fluid GAS

7 Min Operating Max Design

8 Pressure (Barg) 3.5


PROCESS
9 Temperature (C)
DATA
10 Mass Density (Kg/m3) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point - -

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Process Connection Class 2" 600#

20 Body Material SS
SWITCH
21 Float Material SS

22 Enclosure Class Ingress Protection - IP54

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 88/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW4400

2 Service Temperature Indicator

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008-SH 14/21

4 Equipment Number Location - LP FLARE K.O DRUM

5 Area Classification ZONE 2

6 Fluid GAS

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3)

11 Flowrate (Kg/h)

12 Type Bi-Metal

13 Range

14 Stem Type Threaded

15 Stem Material SS

THERMOMETER 16 Stem Length Stem Diameter (*) (*)

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP 54

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7".58

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 89/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI4400

2 Service Pressure Indicator

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008-SH 14/21

4 Equipment Number Location - LP FLARE K.O DRUM

5 Area Classification ZONE 2

6 Fluid GAS

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg)

9 Temperature (C)

10 Range

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS
GAUGE DETAILS
15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP66

21 Connection Flanged

22 Bottom Housing Material SS

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge Threaded 1/2" NPT

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 90/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SWITCH DATASHEET


1 Tag Number PSLL4400 PSHH4400

2 Service Pressure Switch Low Low Pressure Switch High High

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008-SH 14/21

4 Equipment Number Location - -

5 Area Classification ZONE 2

6 Fluid GAS

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3)

11 Flowrate (Kg/h)

12 Switch Type SPDT/SNAP

13 Set point (Barg) - -

14 Setting Trip Factory Set

15 Operating Range 0..100 Bar

16 Class 600#
Process Connection
17 Size 1/2" NPTM

18 Housing Material Aluminum

SWITCH 19 Enclosure Class Ingress Protection - IP54

20 Electrical Connection 2x1.5 mm

21 Power supply 24 VDC

22 Contact Arrangement 2NO/2NC

23 Cable Gland -

24 External Adjustment Required

25 Accuracy (*)

26 Mounting ON VESSEL

27 Manifold 2 Valve Manifold

28 Manifold Material SS

MANIFOLD 29 Inlet 1/2" NPTF

30 Manifold End Connections Outlet 1/2" NPTM

31 Drain 1/4" NPT

31 Local Display Not Required

32 Mounting Brackets -
OPTIONS
33 Sun Shade Not Required

34 LED Indication Not Required

35 Certificate of Conformity Required

36 ATEX Certificate Not Required

37 Sour Service Certificate Not Required

MISCELLANEOUS 38 SIL Certificate Not Required

39 Leakage Test Not Required

40 Hydrostatic Test Not Required

41 Spare Parts Required for Construction, Commissioning and Start-up

42 Vendor Manufacturer (*) (*)

PURCHASE 43 Purchase Order Number Serial Number (*) (*)

44 Model Number (*)

Page 91/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

DUAL CHAMBER LEVEL GAUGE/TRANSMITTER DATASHEET


1 Tag Number LG 4000/LIT4001

2 Service Level Gauge/Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 14/21

4 Equipment Number Location - LP FLARE K.O DRUM

5 Area Classification ZONE 2

6 Fluid GAS

7 Min Operating Max Design

8 Temperature (C)
PROCESS
9 Pressure (Barg)
DATA
10 Mass Density (Kg/m3) -

11 Specific Gravity -

12 Viscosity -

13 Instrument Type Dual chamber

14 Gauge Type Glass

15 Connections Center to Center Distance -

16 Tube Material Glass

GAUGE 17 Size 2"


End Connection
18 Type Flanged 2", 600# RTJ

19 Body Material (*)

20 Cover Material SS

21 Mounting Side Mounted

22 Type Guided wave Radar

SENSOR 23 Insertion Depth -

24 Material SS

25 Indicator Required

26 Output 2 wires, 4..20 mA

27 Reliability -

TRANSMITTER 28 Mounting Integral

29 Power Supply Loop Powered 24 VDC

30 Enclosure Class -

31 Cable Gland -

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 92/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

SHUTDOWN VALVE DATASHEET


1 Tag Number SDV4400

2 Service Shutdown Valve

GENERAL 3 Line Number P&ID Number X"-PC-A31X-4404 AR1602.03-PRO-DRW-008-SH 14/21

4 Equipment Number Location - -

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design


PROCESS
8 Pressure (Barg) - - - -
DATA
9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Type Ball Valve

12 Body Size Port Size 6" Full Bore

13 Maximum Pressure Maximum Temperature (*) (*)

14 Body Material CS

15 Fire Safe YES


VALVE BODY
16 Class Size Flanged RTJ 600# 6"
CHARACTERISTICS Process Connection Type
17 Downstream Flanged 6" 600# RTJ

18 Type of Bonnet Bolted

19 Lubrication Lube Type Required (*)

20 Packing Material PTFE

21 Bolting Material CS

22 Type Trunnion Mounted

23 Size Rated Travel (*) (*)

TRIM 24 Service ON / OFF Valve


CHARACTERISTICS 25 Ball Material SS

26 Seat Insert PTFE

27 Stem Material SS

28 Type Pneumatic and Pinion Spring Return

29 Size (*)

30 Fail Position Closed


ACTUATOR
31 Max. Operating Pressure Max. Allowable Pressure (*) (*)
CHARACTERISTICS
32 Stroking Time Torque 10 sec (*)

33 Handwheel Not Required

34 Safety Factor 100%

35 Tag Number LY4400

36 Type 3-way Valve

37 Input Signal 24 VDC

SOLENOID VALVE 38 Fluid Instrument Air

39 SIL Enclosure/ATEX Class - IP 66 -

40 Body Size Body Material (*) (*)

41 Connection Type Cable Gland (*) M20x1.5

42 Quantity Type

43 Tag Number
LIMIT SWITCH
44 Designation

45 Enclosure Class Cable Gland

UTILITIES 46 Fluid Pressure Instrument Air -

49 ATEX Certificate Sour Service Certificate Required Required

50 SIL Certificate Leakage Test Required Required

MISCELLANEOUS 51 Spare Parts Required for Construction, Commissioning and Start-up

52 Vendor Manufacturer (*) (*)

53 Purchase Order Number Serial Number (*) (*)

Page 93/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI 4401 PI 4402

2 Service Pressure Indicator

GENERAL 3 P&ID Number AR1602.03-PRO-DRW-008-SH 14/21

4 Line Number x"-PC-A31X-4404 x"-PC-A31X-4405

5 Area Classification -

6 Fluid Condensate

7 Min Operating Max Design


PROCESS
8 Pressure (Barg)
DATA
9 Temperature (C)

10 Mass Density (Kg/m3)

11 Range

12 Element Type Bourdon Tube

13 Element Material Pointer Material SS Aluminum

14 Process Connection Connector Position 1/2" NPT From the Bottom

15 Socket/Connector Material SS

GAUGE DETAILS 16 Dial Size Scale 160 mm Barg/PSI

17 Case Material Lens Material SS Laminated glass

18 Fill Fluid NA

19 Over Pressure Limit 130%

20 Nominal Accuracy 0,1 %

21 Ingress Protection Class IP65

22 Bottom Housing Material SS

23 Fill Fluid (*)

24 Process Connection (*)


DIAPHRAGM SEAL
25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge Threaded 1/2" NPT

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2 Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 94/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number PT 4401

2 Service Pressure Transmitter

GENERAL 3 Line Number P&ID Number X"-PG-A31X-4403 AR1602.04-PRO-DRW-008-SH 14/21

4 Equipment Number -

5 Location / Area LP FLARE K.O DRUM

6 Area Classification ZONE 2

7 Fluid GAS

8 Min Operating Max Design


PROCESS
9 Pressure (Barg)
CONDITIONS
10 Temperature (C)

11 Mass Density (Kg/m3)

12 Instrument Range

13 Element Type Diaphragm


ELEMENT
14 Element Material SS

15 Number of wires 2 wire sensor

16 Indicator Scale Not Required Not Required

18 Process Connection Electrical Connection 1/2" NPT M20x1.5

19 Power Supply Load Resistance 24 VDC Loop Powered (*)


TRANSMITTER
20 Packing Material 4..20 mA HART

21 ATEX Rating Ingress Protection EEx d IIA T3 IP 54

22 Accuracy Repeatability 0.05% (*)

23 Manifold 2-way valve : Isolation + vent + Drain


MANIFOLD
24 Size and Rating Inlet 1/2" NPTM x Outlet 1/2" NPTM ; Drain 1/4" NPTF ANSI Class 3000#

25 Certificate of Conformity Required

26 ATEX Certificate Required

27 Sour Service Certificate Not Required

MISCELLANEOUS 28 SIL Certificate Not Required

29 Leakage Test Not Required

30 Hydrostatic Test Not Required

31 Spare Parts Required for Construction, Commissioning and Start-up

32 Vendor Manufacturer (*) (*)

PURCHASE 33 Purchase Order Number Serial Number (*) (*)

34 Model Number (*)

Page 95/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE TRANSMITTER DATASHEET


1 Tag Number TT/TW4401

2 Service Temperature Indicator Transmitter

GENERAL 3 Line Number P&ID Number X"-PG-A31X-4403 AR1602.03-PRO-DRW-008-SH 14/5

4 Equipment Number Location - LP FLARE K.O DRUM

5 Area Classification Zone 2

6 Fluid GAS

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3)

11 Flowrate (Kg/h)

12 Measuring Element RTD

13 Range

14 Material SS

ELEMENT 15 Mounting Thermowell Mounted

16 Number of Wires 3 Wires

17 Sensor Connection 1/2" NPT

18 Diameter (*)

19 Type HART Transmitter

20 Input Signal 3 Wire Pt 100

21 Nb of Wires 2 Wire Transmitter

22 Enclosure Class Ingress Protection EEx d IIA T3 IP 54

23 Local Indicator LCD Display Required

TRANSMITTER 24 Power Supply 24 VDC Loop Powered

25 Level 4..20 mA HART


Output Signal
26 Accuracy Class 1

27 Cable Cable Gland 2x1.5 mm M20x1.5

28 Enclosure Material SS

29 Nameplate Required, Engraved with SS tag plate

30 Material 316 SS

31 Process Connection THREADED NPT 1/2"

32 Sensor Connection 1/2" NPT

THERMOWELL 33 Calculated Immersion Length 7".58

34 Selected Immersion Length (*)

35 External Diameter (*)

36 Construction Type Tapered

37 Certificate of Conformity Required

38 ATEX Certificate Required

39 Sour Service Certificate Not Required

MISCELLANEOUS 40 SIL Certificate Not Required

41 Leakage Test Not Required

42 Hydrostatic Test Not Required

43 Spare Parts Required for Construction, Commissioning and Start-up

44 Vendor Manufacturer (*) (*)

PURCHASE 45 Purchase Order Number Serial Number (*) (*)

46 Model Number (*)

Page 96/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

FLOW TRANSMITTER DATASHEET


1 Tag Number FT4400

2 Service Flow Transmitter

GENERAL 3 Line Number P&ID Number 4"-PG-C31X-4004 AR1602.03-PRO-DRW-008 SH 11/21

4 Equipment Number Location - LP FLARE K.O DRUM

5 Area Classification ZONE 2

6 Fluid GAS

7 Min Operating Max Design

8 Temperature (C)

PROCESS 9 Pressure (Barg)


DATA 10 Flowrate (Kg/h)

11 Density (Kg/m3)

12 Molecular Weight

13 Viscosity

14 Meter Type Integral Orifice Plate Flowmeter

15 Orifice Shape Square Edged

16 Bore Diameter (*)


METER
17 Upstream length Downstream Length 10 D 5D

18 Size & Type X" RTJ


End Connections
19 Class 600#

20 Power Supply 24 VDC Loop Powered

21 Output Signal 4..20 mA


TRANSMITTER
22 Enclosure Class -

23 Cable Gland -

24 Manifold 5-valve manifold (2x1/4" Drain Screws + 2x1/4" Isolation Screws / 1x1/4" Equalizer)

25 Manifold Material SS
ACCESSORIES
26 Inlet 2x1/2" NPTM
Manifold End Connections
27 Outlet 2x1/2" NPTM

28 LCD Indicator Not Required

29 Certificate of Conformity Required

30 ATEX Certificate -

31 Sour Service Certificate Not Required

MISCELLANEOUS 32 SIL Certificate Not Required

33 Leakage Test Not Required

34 Hydrostatic Test Required

35 Spare Parts Required for Construction, Commissioning and Start-up

36 Vendor Manufacturer (*) (*)

PURCHASE 37 Purchase Order Number Serial Number (*) (*)

38 Model Number (*)

Page 97/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW4003

2 Service Temperature Indicator

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location - -

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3)

11 Flowrate (Kg/h)

12 Type Bi-Metal

13 Range

14 Stem Type Threaded

15 Stem Material SS

THERMOMETER 16 Stem Length Stem Diameter (*) (*)

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP54

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7"

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 98/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW4001

2 Service Temperature Indicator

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location - -

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3)

11 Flowrate (Kg/h)

12 Type Bi-Metal

13 Range

14 Stem Type Threaded

15 Stem Material SS

THERMOMETER 16 Stem Length Stem Diameter (*) (*)

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP54

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7".58

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 99/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW4002

2 Service Temperature Indicator

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location - -

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3)

11 Flowrate (Kg/h)

12 Type Bi-Metal

13 Range

14 Stem Type Threaded

15 Stem Material SS

THERMOMETER 16 Stem Length Stem Diameter (*) (*)

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP54

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7".58

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 100/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SAFETY VALVE


1 Tag Number PSV4400/4401

2 Service Pressure Safety Valve

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008-SH 14/21

4 Equipment Number Equipment Designation MBF-4100 LP FLARE K.O DRUM

5 Location / Area TEST SEPARATOR AREA

6 Area Classification ZONE 2

7 Fluid Two phase Crude Oil

8 Min Operating Max Design

9 Pressure (Barg)

10 Temperature (C)

11 Set Pressure (Barg)

12 Back Pressure (Barg)

13 Specific Heat Ratio (Cp/Cv)


PROCESS
14 Mass Density (Kg/m3)
CONDITIONS
15 Molecular Weight

16 Compressibility Factor Z

18 Flowrate to Release (Kg/h)

19 Medium to release

20 Packing Material

21 Selected Orifice Area

22 Rated Relief Capacity (Kg/h)

23 Design Basis API 520

24 Valve Type Conventional

25 Relief Case Blocked Outlet

26 Body Material CS

27 Ingress Protection Class IP 54


TECHNICAL DATA
28 Trim Material SS

29 Spring Material SS

30 Type of connection Flanged

31 Inlet Size Inlet Class - -

32 Outlet Size Outlet Class - -

OTHER 33 Fire Safe as per API 6FA

34 Certificate of Conformity Required

35 ATEX Certificate -

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Not Required

38 Leakage Test Not Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Model Number (*)

Page 101/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

SHUTDOWN VALVE DATASHEET


1 Tag Number SDV4500

2 Service Shutdown Valve

GENERAL 3 Line Number P&ID Number 4"-PO-A31X-4153 AR1602.04-PRO-DRW-008-SH 17/21

4 Equipment Number Location - CRUDE OIL TANK

5 Area Classification ZONE 2

6 Fluid Crude Oil

7 Min Operating Max Design


PROCESS
8 Pressure (Barg) - - - -
DATA
9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Type Ball Valve

12 Body Size Port Size 6" Full Bore

13 Maximum Pressure Maximum Temperature (*) (*)

14 Body Material CS

15 Fire Safe YES


VALVE BODY
16 Class Size Flanged RTJ 600# 6"
CHARACTERISTICS Process Connection Type
17 Downstream Flanged 6" 600# RTJ

18 Type of Bonnet Bolted

19 Lubrication Lube Type Required (*)

20 Packing Material PTFE

21 Bolting Material CS

22 Type Trunnion Mounted

23 Size Rated Travel (*) (*)

TRIM 24 Service ON / OFF Valve


CHARACTERISTICS 25 Ball Material SS

26 Seat Insert PTFE

27 Stem Material SS

28 Type Pneumatic and Pinion Spring Return

29 Size (*)

30 Fail Position Closed


ACTUATOR
31 Max. Operating Pressure Max. Allowable Pressure (*) (*)
CHARACTERISTICS
32 Stroking Time Torque 10 sec (*)

33 Handwheel Not Required

34 Safety Factor 100%

35 Tag Number SDY4500

36 Type 3-way Valve

37 Input Signal 24 VDC

SOLENOID VALVE 38 Fluid Instrument Air

39 SIL Enclosure/ATEX Class - IP 66 -

40 Body Size Body Material (*) (*)

41 Connection Type Cable Gland (*) M20x1.5

42 Quantity Type 2 Proximity Switch

43 Tag Number ZSC4500 ZSO4500


LIMIT SWITCH
44 Designation Closed Open

45 Enclosure Class Cable Gland - M20x1.5

UTILITIES 46 Fluid Pressure Instrument Air -

49 ATEX Certificate Sour Service Certificate Required Required

50 SIL Certificate Leakage Test Required Required

MISCELLANEOUS 51 Spare Parts Required for Construction, Commissioning and Start-up

52 Vendor Manufacturer (*) (*)

53 Purchase Order Number Serial Number (*) (*)

Page 102/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI4500

2 Service Pressure Indicator

GENERAL 3 Line Number P&ID Number X"-PW-A31X-4453 AR1602.04-PRO-DRW-002-SH 17/21

4 Equipment Number Location - LP FLARE K.O DRUM

5 Area Classification ZONE 2

6 Fluid WATER

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg)

9 Temperature (C)

10 Range

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS
GAUGE DETAILS
15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP54

21 Connection Flanged

22 Bottom Housing Material SS

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge Threaded 1/2" NPT

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 103/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI4501

2 Service Pressure Indicator

GENERAL 3 Line Number P&ID Number X"-PG-A31X-4453 AR1602.04-PRO-DRW-002-SH 17/21

4 Equipment Number Location - LP FLARE K.O DRUM

5 Area Classification ZONE 2

6 Fluid GAS

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg)

9 Temperature (C)

10 Range

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS
GAUGE DETAILS
15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP54

21 Connection Flanged

22 Bottom Housing Material SS

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge Threaded 1/2" NPT

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 104/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number PIT 4330

2 Service Pressure Indicator Transmitter

GENERAL 3 Line Number P&ID Number 4"-PG-C31X-4330 AR1602.04-PRO-DRW-008-SH 17/21

4 Equipment Number -

5 Location / Area EXPORT GAS HEADER

6 Area Classification ZONE 2

7 Fluid GAS

8 Min Operating Max Design


PROCESS
9 Pressure (Barg)
CONDITIONS
10 Temperature (C)

11 Mass Density (Kg/m3)

12 Instrument Range

13 Element Type Diaphragm


ELEMENT
14 Element Material SS

15 Number of wires 2 wire sensor

16 Indicator Scale LCD Type Required (*)

18 Process Connection Electrical Connection 1/2" NPT M20x1.5

19 Power Supply Load Resistance 24 VDC Loop Powered (*)


TRANSMITTER
20 Packing Material 4..20 mA HART

21 ATEX Rating Ingress Protection EEx d IIA T3 IP 54

22 Accuracy Repeatability 0.05% (*)

23 Manifold 2-way valve : Isolation + vent + Drain


MANIFOLD
24 Size and Rating Inlet 1/2" NPTM x Outlet 1/2" NPTM ; Drain 1/4" NPTF ANSI Class 3000#

25 Certificate of Conformity Required

26 ATEX Certificate Required

27 Sour Service Certificate Not Required

MISCELLANEOUS 28 SIL Certificate Not Required

29 Leakage Test Not Required

30 Hydrostatic Test Not Required

31 Spare Parts Required for Construction, Commissioning and Start-up

32 Vendor Manufacturer (*) (*)

PURCHASE 33 Purchase Order Number Serial Number (*) (*)

34 Model Number (*)

Page 105/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSHH4500 LSLL4500

2 Service Level Switch High High Level Switch Low Low

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 17/21

4 Equipment Number Location ABJ-4200 CRUDE OIL TANK

5 Area Classification ZONE 2

6 Fluid OIL

7 Min Operating Max Design

8 Pressure (Barg)
PROCESS
9 Temperature (C)
DATA
10 Mass Density (Kg/m3) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point - -

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Process Connection Class 1/2" 600#

20 Body Material SS
SWITCH
21 Float Material SS

22 Enclosure Class Ingress Protection - IP54

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 106/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

DUAL CHAMBER LEVEL GAUGE/TRANSMITTER DATASHEET


1 Tag Number LIT 4300/LG 4300

2 Service LEVEL INDICATOR TRANSMITTER

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH10

4 Equipment Number Equipment Designation MBF-4200 GAS SCRUBBER MBF-4200

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

8 Temperature (C)
PROCESS
9 Pressure (Barg)
DATA
10 Mass Density (Kg/m3) -

11 Specific Gravity -

12 Viscosity -

13 Instrument Type Dual chamber

14 Gauge Type Glass

15 Connections Center to Center Distance HOLD

16 Tube Material Glass

GAUGE 17 Size 2"


End Connection
18 Type Flanged 2", 600# RTJ

19 Body Material (*)

20 Cover Material SS

21 Mounting Side Mounted

22 Type Guided wave Radar

SENSOR 23 Insertion Depth HOLD

24 Material SS

25 Indicator Required

26 Output 2 wires, 4..20 mA

27 Reliability HOLD

TRANSMITTER 28 Mounting Integral

29 Power Supply Loop Powered 24 VDC

30 Enclosure Class HOLD

31 Cable Gland HOLD

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 107/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

DUAL CHAMBER LEVEL GAUGE/TRANSMITTER DATASHEET


1 Tag Number LIT 4350/LG 4350

2 Service LEVEL INDICATOR TRANSMITTER

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH12

4 Equipment Number Equipment Designation MBF-4000 HP FLARE KO DRUM MBF-4000

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

8 Temperature (C)
PROCESS
9 Pressure (Barg)
DATA
10 Mass Density (Kg/m3) -

11 Specific Gravity -

12 Viscosity -

13 Instrument Type Dual chamber

14 Gauge Type Glass

15 Connections Center to Center Distance HOLD

16 Tube Material Glass

GAUGE 17 Size 2"


End Connection
18 Type Flanged 2", 600# RTJ

19 Body Material (*)

20 Cover Material SS

21 Mounting Side Mounted

22 Type Guided wave Radar

SENSOR 23 Insertion Depth HOLD

24 Material SS

25 Indicator Required

26 Output 2 wires, 4..20 mA

27 Reliability HOLD

TRANSMITTER 28 Mounting Integral

29 Power Supply Loop Powered 24 VDC

30 Enclosure Class HOLD

31 Cable Gland HOLD

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 108/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

FLOW TRANSMITTER DATASHEET


1 Tag Number FT 4350

2 Service FLOW TRANSMITTER

GENERAL 3 Line Number P&ID Number X"-PG-A31X-4352 AR1602.03-PRO-DRW-008 REV01_SH12

4 Equipment Number Equipment Designation - HP FLARE KO DRUM MBF-4000

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

8 Temperature (C)

PROCESS 9 Pressure (Barg)


DATA 10 Flowrate (Kg/h)

11 Density (Kg/m3)

12 Molecular Weight

13 Viscosity

14 Meter Type Vortex Flow Meter

15 Orifice Shape

16 Bore Diameter
METER
17 Upstream length Downstream Length

18 Size & Type


End Connections
19 Class

20 Power Supply 24 VDC Loop Powered

21 Output Signal 4..20 mA


TRANSMITTER
22 Enclosure Class HOLD

23 Cable Gland HOLD

24 Manifold

25 Manifold Material
ACCESSORIES
26 Inlet
Manifold End Connections
27 Outlet

28 LCD Indicator

29 Certificate of Conformity Required

30 ATEX Certificate HOLD

31 Sour Service Certificate Not Required

MISCELLANEOUS 32 SIL Certificate Not Required

33 Leakage Test Not Required

34 Hydrostatic Test Required

35 Spare Parts Required for Construction, Commissioning and Start-up

36 Vendor Manufacturer (*) (*)

PURCHASE 37 Purchase Order Number Serial Number (*) (*)

38 Model Number (*)

Page 109/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

DUAL CHAMBER LEVEL GAUGE/TRANSMITTER DATASHEET


1 Tag Number LIT 4450

2 Service LEVEL INDICATOR TRANSMITTER

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH16

4 Equipment Number Equipment Designation ABJ-4100 CRUDE OIL STORAGE TANK ABJ-4100

5 Area Classification ZONE2

6 Fluid -

7 Min Operating Max Design

8 Temperature (C)
PROCESS
9 Pressure (Barg)
DATA
10 Mass Density (Kg/m3) -

11 Specific Gravity -

12 Viscosity -

13 Instrument Type Dual chamber

14 Gauge Type Glass

15 Connections Center to Center Distance HOLD

16 Tube Material Glass

GAUGE 17 Size 2"


End Connection
18 Type Flanged 2", 600# RTJ

19 Body Material (*)

20 Cover Material SS

21 Mounting Side Mounted

22 Type Guided wave Radar

SENSOR 23 Insertion Depth HOLD

24 Material SS

25 Indicator Required

26 Output 2 wires, 4..20 mA

27 Reliability HOLD

TRANSMITTER 28 Mounting Integral

29 Power Supply Loop Powered 24 VDC

30 Enclosure Class HOLD

31 Cable Gland HOLD

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 110/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSHH 4300

2 Service LEVEL SWITCH HIGH HIGH

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH10

4 Equipment Number Equipment Designation MBF-4200 GAS SCRUBBER MBF-4200

5 Area Classification ZONE2

6 Fluid -

7 Min Operating Max Design

8 Pressure (Barg)
PROCESS
9 Temperature (C)
DATA
10 Mass Density (Kg/m3) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point HOLD HOLD

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Process Connection Class

20 Body Material SS
SWITCH
21 Float Material SS

22 Enclosure Class Ingress Protection HOLD IP66

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 111/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSHH 4350

2 Service LEVEL SWITCH HIGH HIGH

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH12

4 Equipment Number Equipment Designation MBF-4000 HP FLARE KO DRUM MBF-4000

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

8 Pressure (Barg)
PROCESS
9 Temperature (C)
DATA
10 Mass Density (Kg/m3) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point HOLD HOLD

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Process Connection Class

20 Body Material SS
SWITCH
21 Float Material SS

22 Enclosure Class Ingress Protection HOLD IP66

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 112/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSHH 4450

2 Service LEVEL SWITCH HIGH HIGH

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH16

4 Equipment Number Equipment Designation ABJ-4100 CRUDE OIL STORAGE TANK ABJ-4100

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

8 Pressure (Barg)
PROCESS
9 Temperature (C)
DATA
10 Mass Density (Kg/m3) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point HOLD HOLD

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Process Connection Class

20 Body Material SS
SWITCH
21 Float Material SS

22 Enclosure Class Ingress Protection HOLD IP66

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 113/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSLL 4350

2 Service LEVEL SWITCH LOW LOW

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH12

4 Equipment Number Equipment Designation MBF-4000 HP FLARE KO DRUM MBF-4000

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

8 Pressure (Barg)
PROCESS
9 Temperature (C)
DATA
10 Mass Density (Kg/m3) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point HOLD HOLD

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Process Connection Class

20 Body Material SS
SWITCH
21 Float Material SS

22 Enclosure Class Ingress Protection HOLD IP66

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 114/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSLL 4450

2 Service LEVEL SWITCH LOW LOW

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH16

4 Equipment Number Equipment Designation ABJ-4100 CRUDE OIL STORAGE TANK ABJ-4100

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

8 Pressure (Barg)
PROCESS
9 Temperature (C)
DATA
10 Mass Density (Kg/m3) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point HOLD HOLD

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Process Connection Class

20 Body Material SS
SWITCH
21 Float Material SS

22 Enclosure Class Ingress Protection HOLD IP66

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 115/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number LV 4300

2 Service LEVEL CONTROL VALVE

GENERAL 3 Line Number P&ID Number X"-PW-A31X-4301 AR1602.03-PRO-DRW-008 REV01_SH10

4 Equipment Number Equipment Designation - GAS SCRUBBER MBF-4200

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

8 Temperature (C)

9 Pressure Drop (Bar)

10 Inlet Pressure (Barg)


3
11 Liquid (m /h)
Flow rate
12 Gas (Kg/h)
PROCESS
13 Calculated Cv (*)
DATA
14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg)

16 Max. Vapor Pressure (Bara)

18 Inlet
Line Size & Shedule
19 Outlet

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Ball

23 Body Size Body Material CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream

26 Type Downstream

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic HOLD

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position HOLD

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 24VDC Instrument Air

39 Air Supply Pressure Range HOLD

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 116/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number PCV 4301

2 Service PRESSURE CONTROL VALVE

GENERAL 3 Line Number P&ID Number X"-FG-A31X-4310 AR1602.03-PRO-DRW-008 REV01_SH10

4 Equipment Number Equipment Designation - GAS SCRUBBER MBF-4200

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

8 Temperature (C)

9 Pressure Drop (Bar)

10 Inlet Pressure (Barg)


3
11 Liquid (m /h)
Flow rate
12 Gas (Kg/h)
PROCESS
13 Calculated Cv (*)
DATA
14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg)

16 Max. Vapor Pressure (Bara)

18 Inlet
Line Size & Shedule
19 Outlet

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Gate

23 Body Size Body Material CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream

26 Type Downstream

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 24VDC Instrument Air

39 Air Supply Pressure Range

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 117/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number PCV 4301

2 Service PRESSURE CONTROL VALVE

GENERAL 3 Line Number P&ID Number X"-FG-A31X-4310 AR1602.03-PRO-DRW-008 REV01_SH10

4 Equipment Number Equipment Designation - GAS SCRUBBER MBF-4200

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

8 Temperature (C)

9 Pressure Drop (Bar)

10 Inlet Pressure (Barg)


3
11 Liquid (m /h)
Flow rate
12 Gas (Kg/h)
PROCESS
13 Calculated Cv (*)
DATA
14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg)

16 Max. Vapor Pressure (Bara)

18 Inlet
Line Size & Shedule
19 Outlet

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Gate

23 Body Size Body Material HOLD CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream HOLD HOLD

26 Type Downstream HOLD HOLD

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 24VDC Instrument Air

39 Air Supply Pressure Range

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 118/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI 4300

2 Service PRESSURE INDICATOR

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH10

4 Equipment Number Equipment Designation MBF-4200 GAS SCRUBBER MBF-4200

5 Area Classification ZONE2

6 Fluid

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg)

9 Temperature (C)

10 Range

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS
GAUGE DETAILS
15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP66

21 Connection

22 Bottom Housing Material

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 119/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI 4301

2 Service PRESSURE INDICATOR

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH10

4 Equipment Number Equipment Designation - GAS SCRUBBER MBF-4200

5 Area Classification ZONE2

6 Fluid

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg)

9 Temperature (C)

10 Range

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS
GAUGE DETAILS
15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP66

21 Connection

22 Bottom Housing Material

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 120/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI 4350

2 Service PRESSURE INDICATOR

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH12

4 Equipment Number Equipment Designation MBF-4000 HP FLARE KO DRUM MBF-4000

5 Area Classification ZONE2

6 Fluid

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg)

9 Temperature (C)

10 Range

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS
GAUGE DETAILS
15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP66

21 Connection

22 Bottom Housing Material

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 121/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI 4351

2 Service PRESSURE INDICATOR

GENERAL 3 Line Number P&ID Number X"-PC-A31X-4353 AR1602.03-PRO-DRW-008 REV01_SH12

4 Equipment Number Equipment Designation - HP FLARE KO DRUM MBF-4000

5 Area Classification ZONE2

6 Fluid

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg)

9 Temperature (C)

10 Range

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS
GAUGE DETAILS
15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP66

21 Connection

22 Bottom Housing Material

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 122/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI 4300

2 Service PRESSURE INDICATOR

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH10

4 Equipment Number Equipment Designation MBF-4200 GAS SCRUBBER MBF-4200

5 Area Classification ZONE2

6 Fluid

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg)

9 Temperature (C)

10 Range

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS
GAUGE DETAILS
15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP66

21 Connection

22 Bottom Housing Material

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 123/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI 4450

2 Service PRESSURE INDICATOR

GENERAL 3 Line Number P&ID Number X"-PW-A31X-4452 AR1602.03-PRO-DRW-008 REV01_SH16

4 Equipment Number Equipment Designation - CRUDE OIL STORAGE TANK ABJ-4100

5 Area Classification ZONE2

6 Fluid

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg)

9 Temperature (C)

10 Range

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS
GAUGE DETAILS
15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP66

21 Connection

22 Bottom Housing Material

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 124/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI 4451

2 Service PRESSURE INDICATOR

GENERAL 3 Line Number P&ID Number X"-PG-A31X-4308 AR1602.03-PRO-DRW-008 REV01_SH16

4 Equipment Number Equipment Designation - CRUDE OIL STORAGE TANK ABJ-4100

5 Area Classification ZONE2

6 Fluid

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg)

9 Temperature (C)

10 Range

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS
GAUGE DETAILS
15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP66

21 Connection

22 Bottom Housing Material

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 125/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI 4800

2 Service PRESSURE INDICATOR

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH22

4 Equipment Number Equipment Designation ZZZ4700 B ZZZ4600 & 4700 A-B

5 Area Classification ZONE2

6 Fluid

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg)

9 Temperature (C)

10 Range

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS
GAUGE DETAILS
15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP66

21 Connection

22 Bottom Housing Material

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 126/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI 4801

2 Service PRESSURE INDICATOR

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH22

4 Equipment Number Equipment Designation ZZZ4700 A ZZZ4600 & 4700 A-B

5 Area Classification ZONE2

6 Fluid

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg)

9 Temperature (C)

10 Range

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS
GAUGE DETAILS
15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP66

21 Connection

22 Bottom Housing Material

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 127/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number PIT 4300

2 Service PRESSURE INDICATOR TRANSMITTER

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH10

4 Equipment Number Equipment Designation MBF-4200 GAS SCRUBBER MBF-4200

5 Location / Area TEST SEPARATOR AREA

6 Area Classification ZONE2

7 Fluid -

8 Min Operating Max Design


PROCESS
9 Pressure (Barg)
CONDITIONS
10 Temperature (C)

11 Mass Density (Kg/m3)

12 Instrument Range

13 Element Type Diaphragm


ELEMENT
14 Element Material SS

15 Number of wires 2 wire sensor

16 Indicator Scale LCD Type Required (*)

18 Process Connection Electrical Connection 1/2" NPT M20x1.5

19 Power Supply Load Resistance 24 VDC Loop Powered (*)


TRANSMITTER
20 Output Signal 4..20 mA HART

21 ATEX Rating Ingress Protection EEx d IIA T3 IP 66

22 Accuracy Repeatability 0.05% (*)

23 Manifold 2-way valve : Isolation + vent + Drain


MANIFOLD
24 Size and Rating Inlet 1/2" NPTM x Outlet 1/2" NPTM ; Drain 1/4" NPTF ANSI Class 3000#

25 Certificate of Conformity Required

26 ATEX Certificate HOLD

27 Sour Service Certificate Not Required

MISCELLANEOUS 28 SIL Certificate Not Required

29 Leakage Test Not Required

30 Hydrostatic Test Not Required

31 Spare Parts Required for Construction, Commissioning and Start-up

32 Vendor Manufacturer (*) (*)

PURCHASE 33 Purchase Order Number Serial Number (*) (*)

34 Model Number (*)

Page 128/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number PIT 4351

2 Service PRESSURE TRANSMITTER

GENERAL 3 Line Number P&ID Number X"-PG-A31X-4352 AR1602.03-PRO-DRW-008 REV01_SH12

4 Equipment Number Equipment Designation - HP FLARE KO DRUM MBF-4000

5 Location / Area TEST SEPARATOR AREA

6 Area Classification ZONE2

7 Fluid -

8 Min Operating Max Design


PROCESS
9 Pressure (Barg)
CONDITIONS
10 Temperature (C)

11 Mass Density (Kg/m3)

12 Instrument Range

13 Element Type Diaphragm


ELEMENT
14 Element Material SS

15 Number of wires 2 wire sensor

16 Indicator Scale LCD Type Required (*)

18 Process Connection Electrical Connection 1/2" NPT M20x1.5

19 Power Supply Load Resistance 24 VDC Loop Powered (*)


TRANSMITTER
20 Output Signal 4..20 mA HART

21 ATEX Rating Ingress Protection EEx d IIA T3 IP 66

22 Accuracy Repeatability 0.05% (*)

23 Manifold 2-way valve : Isolation + vent + Drain


MANIFOLD
24 Size and Rating Inlet 1/2" NPTM x Outlet 1/2" NPTM ; Drain 1/4" NPTF ANSI Class 3000#

25 Certificate of Conformity Required

26 ATEX Certificate HOLD

27 Sour Service Certificate Not Required

MISCELLANEOUS 28 SIL Certificate Not Required

29 Leakage Test Not Required

30 Hydrostatic Test Not Required

31 Spare Parts Required for Construction, Commissioning and Start-up

32 Vendor Manufacturer (*) (*)

PURCHASE 33 Purchase Order Number Serial Number (*) (*)

34 Model Number (*)

Page 129/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number PIT 4450

2 Service PRESSURE INDICATOR TRANSMITTER

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH16

4 Equipment Number Equipment Designation ABJ-4100 CRUDE OIL STORAGE TANK ABJ-4100

5 Location / Area TEST SEPARATOR AREA

6 Area Classification ZONE2

7 Fluid -

8 Min Operating Max Design


PROCESS
9 Pressure (Barg)
CONDITIONS
10 Temperature (C)

11 Mass Density (Kg/m3)

12 Instrument Range

13 Element Type Diaphragm


ELEMENT
14 Element Material SS

15 Number of wires 2 wire sensor

16 Indicator Scale LCD Type Required (*)

18 Process Connection Electrical Connection 1/2" NPT M20x1.5

19 Power Supply Load Resistance 24 VDC Loop Powered (*)


TRANSMITTER
20 Output Signal 4..20 mA HART

21 ATEX Rating Ingress Protection EEx d IIA T3 IP 66

22 Accuracy Repeatability 0.05% (*)

23 Manifold 2-way valve : Isolation + vent + Drain


MANIFOLD
24 Size and Rating Inlet 1/2" NPTM x Outlet 1/2" NPTM ; Drain 1/4" NPTF ANSI Class 3000#

25 Certificate of Conformity Required

26 ATEX Certificate HOLD

27 Sour Service Certificate Not Required

MISCELLANEOUS 28 SIL Certificate Not Required

29 Leakage Test Not Required

30 Hydrostatic Test Not Required

31 Spare Parts Required for Construction, Commissioning and Start-up

32 Vendor Manufacturer (*) (*)

PURCHASE 33 Purchase Order Number Serial Number (*) (*)

34 Model Number (*)

Page 130/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SWITCH DATASHEET


1 Tag Number PSHH 4300

2 Service PRESSURE SWITCH HIGH HIGH

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH10

4 Equipment Number Equipment Designation MBF-4200 GAS SCRUBBER MBF-4200

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3) -

11 Flowrate (Kg/h) -

12 Switch Type SPDT/SNAP

13 Set point (Barg)

14 Setting Trip Factory Set

15 Operating Range

16 Process Connection Class

18 Housing Material Aluminum

19 Enclosure Class Ingress Protection IP66


SWITCH
20 Packing Material 2x1.5 mm

21 Power supply 24 VDC

22 Contact Arrangement 2NO/2NC

23 Cable Gland M20x1.5

24 External Adjustment Required

25 Accuracy (*)

26 Mounting On pipe

27 Manifold 2 Valve Manifold

28 Manifold Material SS

MANIFOLD 29 Inlet 1/2" NPTF

30 Manifold End Connections Outlet 1/2" NPTM

31 Drain 1/4" NPT

32 Local Display Not Required

33 Mounting Brackets Required


OPTIONS
34 Sun Shade Not Required

35 LED Indication Not Required

36 Certificate of Conformity Required

37 ATEX Certificate Not Required

38 Sour Service Certificate Not Required

MISCELLANEOUS 39 SIL Certificate Not Required

40 Leakage Test Not Required

41 Hydrostatic Test Not Required

42 Spare Parts Required for Construction, Commissioning and Start-up

43 Vendor Manufacturer (*) (*)

PURCHASE 44 Purchase Order Number Serial Number (*) (*)

45 Model Number (*)

Page 131/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SWITCH DATASHEET


1 Tag Number PSHH 4350

2 Service PRESSURE SWITCH HIGH HIGH

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH12

4 Equipment Number Equipment Designation MBF-4000 HP FLARE KO DRUM MBF-4000

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3) -

11 Flowrate (Kg/h) -

12 Switch Type SPDT/SNAP

13 Set point (Barg)

14 Setting Trip Factory Set

15 Operating Range

16 Process Connection Class

18 Housing Material Aluminum

19 Enclosure Class Ingress Protection IP66


SWITCH
20 Packing Material 2x1.5 mm

21 Power supply 24 VDC

22 Contact Arrangement 2NO/2NC

23 Cable Gland M20x1.5

24 External Adjustment Required

25 Accuracy (*)

26 Mounting On pipe

27 Manifold 2 Valve Manifold

28 Manifold Material SS

MANIFOLD 29 Inlet 1/2" NPTF

30 Manifold End Connections Outlet 1/2" NPTM

31 Drain 1/4" NPT

32 Local Display Not Required

33 Mounting Brackets Required


OPTIONS
34 Sun Shade Not Required

35 LED Indication Not Required

36 Certificate of Conformity Required

37 ATEX Certificate Not Required

38 Sour Service Certificate Not Required

MISCELLANEOUS 39 SIL Certificate Not Required

40 Leakage Test Not Required

41 Hydrostatic Test Not Required

42 Spare Parts Required for Construction, Commissioning and Start-up

43 Vendor Manufacturer (*) (*)

PURCHASE 44 Purchase Order Number Serial Number (*) (*)

45 Model Number (*)

Page 132/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SWITCH DATASHEET


1 Tag Number PSLL 4300

2 Service PRESSURE SWITCH LOW LOW

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH10

4 Equipment Number Equipment Designation MBF-4200 GAS SCRUBBER MBF-4200

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3) -

11 Flowrate (Kg/h) -

12 Switch Type SPDT/SNAP

13 Set point (Barg) HOLD HOLD

14 Setting Trip Factory Set

15 Operating Range

16 Process Connection Class

18 Housing Material Aluminum

19 Enclosure Class Ingress Protection HOLD IP66


SWITCH
20 Packing Material 2x1.5 mm

21 Power supply 24 VDC

22 Contact Arrangement 2NO/2NC

23 Cable Gland M20x1.5

24 External Adjustment Required

25 Accuracy (*)

26 Mounting On pipe

27 Manifold 2 Valve Manifold

28 Manifold Material SS

MANIFOLD 29 Inlet 1/2" NPTF

30 Manifold End Connections Outlet 1/2" NPTM

31 Drain 1/4" NPT

32 Local Display Not Required

33 Mounting Brackets Required


OPTIONS
34 Sun Shade Not Required

35 LED Indication Not Required

36 Certificate of Conformity Required

37 ATEX Certificate Not Required

38 Sour Service Certificate Not Required

MISCELLANEOUS 39 SIL Certificate Not Required

40 Leakage Test Not Required

41 Hydrostatic Test Not Required

42 Spare Parts Required for Construction, Commissioning and Start-up

43 Vendor Manufacturer (*) (*)

PURCHASE 44 Purchase Order Number Serial Number (*) (*)

45 Model Number (*)

Page 133/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SWITCH DATASHEET


1 Tag Number PSLL 4350

2 Service PRESSURE SWITCH LOW LOW

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH12

4 Equipment Number Equipment Designation MBF-4000 HP FLARE KO DRUM MBF-4000

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3) -

11 Flowrate (Kg/h) -

12 Switch Type SPDT/SNAP

13 Set point (Barg) HOLD HOLD

14 Setting Trip Factory Set

15 Operating Range

16 Process Connection Class

18 Housing Material Aluminum

19 Enclosure Class Ingress Protection HOLD IP66


SWITCH
20 Packing Material 2x1.5 mm

21 Power supply 24 VDC

22 Contact Arrangement 2NO/2NC

23 Cable Gland M20x1.5

24 External Adjustment Required

25 Accuracy (*)

26 Mounting On pipe

27 Manifold 2 Valve Manifold

28 Manifold Material SS

MANIFOLD 29 Inlet 1/2" NPTF

30 Manifold End Connections Outlet 1/2" NPTM

31 Drain 1/4" NPT

32 Local Display Not Required

33 Mounting Brackets Required


OPTIONS
34 Sun Shade Not Required

35 LED Indication Not Required

36 Certificate of Conformity Required

37 ATEX Certificate Not Required

38 Sour Service Certificate Not Required

MISCELLANEOUS 39 SIL Certificate Not Required

40 Leakage Test Not Required

41 Hydrostatic Test Not Required

42 Spare Parts Required for Construction, Commissioning and Start-up

43 Vendor Manufacturer (*) (*)

PURCHASE 44 Purchase Order Number Serial Number (*) (*)

45 Model Number (*)

Page 134/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SWITCH DATASHEET


1 Tag Number PSLL 4751

2 Service PRESSURE SWITCH LOW LOW

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH20

4 Equipment Number Equipment Designation MBF-4400 AIR DRYER MBE-4000 A/B

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3) -

11 Flowrate (Kg/h) -

12 Switch Type SPDT/SNAP

13 Set point (Barg) HOLD HOLD

14 Setting Trip Factory Set

15 Operating Range

16 Process Connection Class

18 Housing Material Aluminum

19 Enclosure Class Ingress Protection HOLD IP66


SWITCH
20 Packing Material 2x1.5 mm

21 Power supply 24 VDC

22 Contact Arrangement 2NO/2NC

23 Cable Gland M20x1.5

24 External Adjustment Required

25 Accuracy (*)

26 Mounting On pipe

27 Manifold 2 Valve Manifold

28 Manifold Material SS

MANIFOLD 29 Inlet 1/2" NPTF

30 Manifold End Connections Outlet 1/2" NPTM

31 Drain 1/4" NPT

32 Local Display Not Required

33 Mounting Brackets Required


OPTIONS
34 Sun Shade Not Required

35 LED Indication Not Required

36 Certificate of Conformity Required

37 ATEX Certificate Not Required

38 Sour Service Certificate Not Required

MISCELLANEOUS 39 SIL Certificate Not Required

40 Leakage Test Not Required

41 Hydrostatic Test Not Required

42 Spare Parts Required for Construction, Commissioning and Start-up

43 Vendor Manufacturer (*) (*)

PURCHASE 44 Purchase Order Number Serial Number (*) (*)

45 Model Number (*)

Page 135/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SAFETY VALVE


1 Tag Number PSV 4300

2 Service PRESSURE SAFETY VALVE

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH10

4 Equipment Number Equipment Designation - GAS SCRUBBER MBF-4200

5 Location / Area GAS SCRUBBER MBF-4200

6 Area Classification ZONE2

7 Fluid

8 Min Operating Max Design

9 Pressure (Barg)

10 Temperature (C)

11 Set Pressure (Barg)

12 Back Pressure (Barg)

13 Specific Heat Ratio (Cp/Cv)


PROCESS
14 Mass Density (Kg/m3)
CONDITIONS
15 Molecular Weight

16 Compressibility Factor Z

18 Flowrate to Release (Kg/h)

19 Medium to release

20 Packing Material

21 Selected Orifice Area

22 Rated Relief Capacity (Kg/h) -

23 Design Basis API 520

24 Valve Type Conventional

25 Relief Case Blocked Outlet

26 Body Material CS

27 Ingress Protection Class IP 66


TECHNICAL DATA
28 Trim Material SS

29 Spring Material SS

30 Type of connection Flanged

31 Inlet Size Inlet Class 1"1/2 #150

32 Outlet Size Outlet Class 3" #150

OTHER 33 Fire Safe as per API 6FA

34 Certificate of Conformity Required

35 ATEX Certificate HOLD

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Not Required

38 Leakage Test Not Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Model Number (*)

Page 136/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SAFETY VALVE


1 Tag Number PSV 4301

2 Service PRESSURE SAFETY VALVE

GENERAL 3 Line Number P&ID Number X"-FG-A31X-4302 AR1602.03-PRO-DRW-008 REV01_SH10

4 Equipment Number Equipment Designation - GAS SCRUBBER MBF-4200

5 Location / Area GAS SCRUBBER MBF-4200

6 Area Classification ZONE2

7 Fluid

8 Min Operating Max Design

9 Pressure (Barg)

10 Temperature (C)

11 Set Pressure (Barg)

12 Back Pressure (Barg)

13 Specific Heat Ratio (Cp/Cv)


PROCESS
14 Mass Density (Kg/m3)
CONDITIONS
15 Molecular Weight

16 Compressibility Factor Z

18 Flowrate to Release (Kg/h)

19 Medium to release

20 Packing Material

21 Selected Orifice Area

22 Rated Relief Capacity (Kg/h)

23 Design Basis API 520

24 Valve Type Conventional

25 Relief Case Blocked Outlet

26 Body Material CS

27 Ingress Protection Class IP 66


TECHNICAL DATA
28 Trim Material SS

29 Spring Material SS

30 Type of connection Flanged

31 Inlet Size Inlet Class 1"1/2 #150

32 Outlet Size Outlet Class 3" #150

OTHER 33 Fire Safe as per API 6FA

34 Certificate of Conformity Required

35 ATEX Certificate HOLD

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Not Required

38 Leakage Test Not Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Model Number (*)

Page 137/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SAFETY VALVE


1 Tag Number PSV 4350

2 Service PRESSURE SAFETY VALVE

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH12

4 Equipment Number Equipment Designation - HP FLARE KO DRUM MBF-4000

5 Location / Area HP FLARE KO DRUM MBF-4000

6 Area Classification ZONE2

7 Fluid

8 Min Operating Max Design

9 Pressure (Barg)

10 Temperature (C)

11 Set Pressure (Barg)

12 Back Pressure (Barg)

13 Specific Heat Ratio (Cp/Cv) -


PROCESS
14 Mass Density (Kg/m3) -
CONDITIONS
15 Molecular Weight -

16 Compressibility Factor Z -

18 Flowrate to Release (Kg/h)

19 Medium to release

20 Packing Material

21 Selected Orifice Area

22 Rated Relief Capacity (Kg/h) -

23 Design Basis API 520

24 Valve Type Conventional

25 Relief Case Blocked Outlet

26 Body Material CS

27 Ingress Protection Class IP 66


TECHNICAL DATA
28 Trim Material SS

29 Spring Material SS

30 Type of connection Flanged

31 Inlet Size Inlet Class

32 Outlet Size Outlet Class

OTHER 33 Fire Safe as per API 6FA

34 Certificate of Conformity Required

35 ATEX Certificate HOLD

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Not Required

38 Leakage Test Not Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Model Number (*)

Page 138/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SAFETY VALVE


1 Tag Number PSV 4351

2 Service PRESSURE SAFETY VALVE

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH12

4 Equipment Number Equipment Designation - HP FLARE KO DRUM MBF-4000

5 Location / Area HP FLARE KO DRUM MBF-4000

6 Area Classification ZONE2

7 Fluid

8 Min Operating Max Design

9 Pressure (Barg)

10 Temperature (C)

11 Set Pressure (Barg)

12 Back Pressure (Barg)

13 Specific Heat Ratio (Cp/Cv) -


PROCESS
14 Mass Density (Kg/m3) -
CONDITIONS
15 Molecular Weight -

16 Compressibility Factor Z -

18 Flowrate to Release (Kg/h)

19 Medium to release

20 Packing Material

21 Selected Orifice Area

22 Rated Relief Capacity (Kg/h) -

23 Design Basis API 520

24 Valve Type Conventional

25 Relief Case Blocked Outlet

26 Body Material CS

27 Ingress Protection Class IP 66


TECHNICAL DATA
28 Trim Material SS

29 Spring Material SS

30 Type of connection Flanged

31 Inlet Size Inlet Class

32 Outlet Size Outlet Class

OTHER 33 Fire Safe as per API 6FA

34 Certificate of Conformity Required

35 ATEX Certificate HOLD

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Not Required

38 Leakage Test Not Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Model Number (*)

Page 139/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

SHUTDOWN VALVE DATASHEET


1 Tag Number SDV 4200

2 Service SHUTDOWN VALVE

GENERAL 3 Line Number P&ID Number 4"-PF-C31X-4206 AR1602.03-PRO-DRW-008 REV01_SH7

4 Equipment Number Location - INDIRECT FIRED HEATER

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design


PROCESS
8 Pressure (Barg)
DATA
9 Temperature (C)

10 Mass Density (Kg/m3)

11 Type Ball Valve

12 Body Size Port Size 4" Full Bore

13 Maximum Pressure Maximum Temperature (*) (*)

14 Body Material CS

VALVE BODY 15 Fire Safe YES


CHARACTERISTICS 16 Process Connection Type Class Size Flanged RTJ 4"

18 Type of Bonnet Bolted

19 Lubrication Lube Type Required (*)

20 Packing Material PTFE

21 Bolting Material CS

22 Type Trunnion Mounted

23 Size Rated Travel (*) (*)

TRIM 24 Service ON / OFF Valve


CHARACTERISTICS 25 Ball Material SS

26 Seat Insert PTFE

27 Stem Material SS

28 Type Pneumatic and Pinion Spring Return

29 Size (*)

30 Fail Position Closed


ACTUATOR
31 Max. Operating Pressure Max. Allowable Pressure (*) (*)
CHARACTERISTICS
32 Stroking Time Torque 10 sec (*)

33 Handwheel Not Required

34 Safety Factor 100%

35 Tag Number SDY 4200

36 Type 3-way Valve

37 Input Signal 24 VDC

SOLENOID VALVE 38 Fluid Instrument Air

39 SIL Enclosure/ATEX Class - IP54 -

40 Body Size Body Material (*) (*)

41 Connection Type Cable Gland (*) M20x1.5

42 Quantity Type 2 Proximity Switch

43 Tag Number ZSC 4200 ZSO 4200


LIMIT SWITCH
44 Designation Closed Open

45 Enclosure Class Cable Gland - M20x1.5

UTILITIES 46 Fluid Pressure Instrument Air -

49 ATEX Certificate Sour Service Certificate Required Required

50 SIL Certificate Leakage Test Required Required

MISCELLANEOUS 51 Spare Parts Required for Construction, Commissioning and Start-up

52 Vendor Manufacturer (*) (*)

53 Purchase Order Number Serial Number (*) (*)

Page 140/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

SHUTDOWN VALVE DATASHEET


1 Tag Number SDV 4273

2 Service SHUTDOWN VALVE

GENERAL 3 Line Number P&ID Number 2"-PG-C31X-4255 AR1602.03-PRO-DRW-008 REV01_SH9

4 Equipment Number Location - 3rd STAGE GAS COMPRESSOR

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design


PROCESS
8 Pressure (Barg)
DATA
9 Temperature (C)

10 Mass Density (Kg/m3)

11 Type Ball Valve

12 Body Size Port Size 2" Full Bore

13 Maximum Pressure Maximum Temperature (*) (*)

14 Body Material CS

VALVE BODY 15 Fire Safe YES


CHARACTERISTICS 16 Process Connection Type Class Size Flanged RTJ 2"

18 Type of Bonnet Bolted

19 Lubrication Lube Type Required (*)

20 Packing Material PTFE

21 Bolting Material CS

22 Type Trunnion Mounted

23 Size Rated Travel (*) (*)

TRIM 24 Service ON / OFF Valve


CHARACTERISTICS 25 Ball Material SS

26 Seat Insert PTFE

27 Stem Material SS

28 Type Pneumatic and Pinion Spring Return

29 Size (*)

30 Fail Position Closed


ACTUATOR
31 Max. Operating Pressure Max. Allowable Pressure (*) (*)
CHARACTERISTICS
32 Stroking Time Torque 10 sec (*)

33 Handwheel Not Required

34 Safety Factor 100%

35 Tag Number SDY 4273

36 Type 3-way Valve

37 Input Signal 24 VDC

SOLENOID VALVE 38 Fluid Instrument Air

39 SIL Enclosure/ATEX Class - IP54 -

40 Body Size Body Material (*) (*)

41 Connection Type Cable Gland (*) M20x1.5

42 Quantity Type 2 Proximity Switch

43 Tag Number ZSC 4273 ZSO 4273


LIMIT SWITCH
44 Designation Closed Open

45 Enclosure Class Cable Gland - M20x1.5

UTILITIES 46 Fluid Pressure Instrument Air -

49 ATEX Certificate Sour Service Certificate Required Required

50 SIL Certificate Leakage Test Required Required

MISCELLANEOUS 51 Spare Parts Required for Construction, Commissioning and Start-up

52 Vendor Manufacturer (*) (*)

53 Purchase Order Number Serial Number (*) (*)

Page 141/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

SHUTDOWN VALVE DATASHEET


1 Tag Number SDV 4300

2 Service SHUTDOWN VALVE

GENERAL 3 Line Number P&ID Number 2"-PG-C31X-4300 AR1602.03-PRO-DRW-008 REV01_SH10

4 Equipment Number Location - GAS SCRUBBER MBF-4200

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design


PROCESS
8 Pressure (Barg)
DATA
9 Temperature (C)

10 Mass Density (Kg/m3)

11 Type Ball Valve

12 Body Size Port Size 2" Full Bore

13 Maximum Pressure Maximum Temperature (*) (*)

14 Body Material CS

VALVE BODY 15 Fire Safe YES


CHARACTERISTICS 16 Process Connection Type Class Size Flanged RTJ 2"

18 Type of Bonnet Bolted

19 Lubrication Lube Type Required (*)

20 Packing Material PTFE

21 Bolting Material CS

22 Type Trunnion Mounted

23 Size Rated Travel (*) (*)

TRIM 24 Service ON / OFF Valve


CHARACTERISTICS 25 Ball Material SS

26 Seat Insert PTFE

27 Stem Material SS

28 Type Pneumatic and Pinion Spring Return

29 Size (*)

30 Fail Position Closed


ACTUATOR
31 Max. Operating Pressure Max. Allowable Pressure (*) (*)
CHARACTERISTICS
32 Stroking Time Torque 10 sec (*)

33 Handwheel Not Required

34 Safety Factor 100%

35 Tag Number SDY 4300

36 Type 3-way Valve

37 Input Signal 24 VDC

SOLENOID VALVE 38 Fluid Instrument Air

39 SIL Enclosure/ATEX Class - IP54 -

40 Body Size Body Material (*) (*)

41 Connection Type Cable Gland (*) M20x1.5

42 Quantity Type 2 Proximity Switch

43 Tag Number ZSC 4300 ZSO 4300


LIMIT SWITCH
44 Designation Closed Open

45 Enclosure Class Cable Gland - M20x1.5

UTILITIES 46 Fluid Pressure Instrument Air -

49 ATEX Certificate Sour Service Certificate Required Required

50 SIL Certificate Leakage Test Required Required

MISCELLANEOUS 51 Spare Parts Required for Construction, Commissioning and Start-up

52 Vendor Manufacturer (*) (*)

53 Purchase Order Number Serial Number (*) (*)

Page 142/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

SHUTDOWN VALVE DATASHEET


1 Tag Number SDV 4350

2 Service SHUTDOWN VALVE

GENERAL 3 Line Number P&ID Number X"-PC-A31X-4353 AR1602.03-PRO-DRW-008 REV01_SH12

4 Equipment Number Location - HP FLARE KO DRUM MBF-4000

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design


PROCESS
8 Pressure (Barg)
DATA
9 Temperature (C)

10 Mass Density (Kg/m3)

11 Type Ball Valve

12 Body Size Port Size Full Bore

13 Maximum Pressure Maximum Temperature (*) (*)

14 Body Material CS

VALVE BODY 15 Fire Safe YES


CHARACTERISTICS 16 Process Connection Type Class Size Flanged RTJ

18 Type of Bonnet Bolted

19 Lubrication Lube Type Required (*)

20 Packing Material PTFE

21 Bolting Material CS

22 Type Trunnion Mounted

23 Size Rated Travel (*) (*)

TRIM 24 Service ON / OFF Valve


CHARACTERISTICS 25 Ball Material SS

26 Seat Insert PTFE

27 Stem Material SS

28 Type Pneumatic and Pinion Spring Return

29 Size (*)

30 Fail Position Closed


ACTUATOR
31 Max. Operating Pressure Max. Allowable Pressure (*) (*)
CHARACTERISTICS
32 Stroking Time Torque 10 sec (*)

33 Handwheel Not Required

34 Safety Factor 100%

35 Tag Number SDY 4350

36 Type 3-way Valve

37 Input Signal 24 VDC

SOLENOID VALVE 38 Fluid Instrument Air

39 SIL Enclosure/ATEX Class - IP54 -

40 Body Size Body Material (*) (*)

41 Connection Type Cable Gland (*) M20x1.5

42 Quantity Type 2 Proximity Switch

43 Tag Number ZSC 4350 ZSO 4350


LIMIT SWITCH
44 Designation Closed Open

45 Enclosure Class Cable Gland - M20x1.5

UTILITIES 46 Fluid Pressure Instrument Air -

49 ATEX Certificate Sour Service Certificate Required Required

50 SIL Certificate Leakage Test Required Required

MISCELLANEOUS 51 Spare Parts Required for Construction, Commissioning and Start-up

52 Vendor Manufacturer (*) (*)

53 Purchase Order Number Serial Number (*) (*)

Page 143/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

SHUTDOWN VALVE DATASHEET


1 Tag Number SDV 4450

2 Service SHUTDOWN VALVE

GENERAL 3 Line Number P&ID Number 4"-PO-A31X-4450 AR1602.03-PRO-DRW-008 REV01_SH16

4 Equipment Number Location - CRUDE OIL STORAGE TANK ABJ-4100

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design


PROCESS
8 Pressure (Barg)
DATA
9 Temperature (C)

10 Mass Density (Kg/m3)

11 Type Ball Valve

12 Body Size Port Size 4" Full Bore

13 Maximum Pressure Maximum Temperature (*) (*)

14 Body Material CS

VALVE BODY 15 Fire Safe YES


CHARACTERISTICS 16 Process Connection Type Class Size Flanged RTJ 4"

18 Type of Bonnet Bolted

19 Lubrication Lube Type Required (*)

20 Packing Material PTFE

21 Bolting Material CS

22 Type Trunnion Mounted

23 Size Rated Travel (*) (*)

TRIM 24 Service ON / OFF Valve


CHARACTERISTICS 25 Ball Material SS

26 Seat Insert PTFE

27 Stem Material SS

28 Type Pneumatic and Pinion Spring Return

29 Size (*)

30 Fail Position Closed


ACTUATOR
31 Max. Operating Pressure Max. Allowable Pressure (*) (*)
CHARACTERISTICS
32 Stroking Time Torque 10 sec (*)

33 Handwheel Not Required

34 Safety Factor 100%

35 Tag Number SDY 4450

36 Type 3-way Valve

37 Input Signal 24 VDC

SOLENOID VALVE 38 Fluid Instrument Air

39 SIL Enclosure/ATEX Class - IP54 -

40 Body Size Body Material (*) (*)

41 Connection Type Cable Gland (*) M20x1.5

42 Quantity Type 2 Proximity Switch

43 Tag Number ZSC 4450 ZSO 4450


LIMIT SWITCH
44 Designation Closed Open

45 Enclosure Class Cable Gland - M20x1.5

UTILITIES 46 Fluid Pressure Instrument Air -

49 ATEX Certificate Sour Service Certificate Required Required

50 SIL Certificate Leakage Test Required Required

MISCELLANEOUS 51 Spare Parts Required for Construction, Commissioning and Start-up

52 Vendor Manufacturer (*) (*)

53 Purchase Order Number Serial Number (*) (*)

Page 144/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW 4300

2 Service TEMPERATURE INDICATOR WITH THERMOWELL

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH10

4 Equipment Number Equipment Designation MBF-4200 GAS SCRUBBER MBF-4200

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3)

11 Flowrate (Kg/h)

12 Type Bi-Metal

13 Range

14 Stem Type Threaded

15 Stem Material SS

THERMOMETER 16 Stem Length Stem Diameter (*) (*)

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP 66

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7".58

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 145/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW 4350

2 Service TEMPERATURE INDICATOR WITH THERMOWELL

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH12

4 Equipment Number Equipment Designation MBF-4000 HP FLARE KO DRUM MBF-4000

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3)

11 Flowrate (Kg/h)

12 Type Bi-Metal

13 Range

14 Stem Type Threaded

15 Stem Material SS

THERMOMETER 16 Stem Length Stem Diameter (*) (*)

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP 66

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7".58

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 146/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number TT/TW 4351

2 Service TEMPERATURE TRANSMITTER WITH TEMPERATURE ELEMENT AND THERMOWELL

GENERAL 3 Line Number P&ID Number X"-PG-A31X-4352 AR1602.03-PRO-DRW-008 REV01_SH12

4 Equipment Number Equipment Designation - HP FLARE KO DRUM MBF-4000

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3)

11 Flowrate (Kg/h)

12 Measuring Element RTD

13 Range

14 Material SS
ELEMENT
15 Mounting Thermowell Mounted

16 Number of Wires 3 Wires

18 Diameter (*)

19 Type HART Transmitter

20 Packing Material 3 Wire Pt 100

21 Nb of Wires 2 Wire Transmitter

22 Enclosure Class Ingress Protection EEx d IIA T3 IP 66

23 Local Indicator LCD Display Required

TRANSMITTER 24 Power Supply 24 VDC Loop Powered

25 Level 4..20 mA HART


Output Signal
26 Accuracy Class 1

27 Cable Cable Gland 2x1.5 mm M20x1.5

28 Enclosure Material SS

29 Nameplate Required, Engraved with SS tag plate

30 Material 316 SS

31 Process Connection Flanged 600 RTJ 1 1/2"

32 Sensor Connection 1/2" NPT

THERMOWELL 33 Calculated Immersion Length 7".58

34 Selected Immersion Length (*)

35 External Diameter (*)

36 Construction Type Tapered

37 Certificate of Conformity Required

38 ATEX Certificate Required

39 Sour Service Certificate Not Required

MISCELLANEOUS 40 SIL Certificate Not Required

41 Leakage Test Not Required

42 Hydrostatic Test Not Required

43 Spare Parts Required for Construction, Commissioning and Start-up

44 Vendor Manufacturer (*) (*)

PURCHASE 45 Purchase Order Number Serial Number (*) (*)

46 Model Number (*)

Page 147/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number TT/TW 4450

2 Service TEMPERATURE INDICATOR WITH THERMOWELL

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH16

4 Equipment Number Equipment Designation ABJ-4100 CRUDE OIL STORAGE TANK ABJ-4100

5 Area Classification ZONE2

6 Fluid

7 Min Operating Max Design

PROCESS 8 Pressure (Barg)


DATA 9 Temperature (C)

10 Mass Density (Kg/m3)

11 Flowrate (Kg/h)

12 Measuring Element RTD

13 Range

14 Material SS
ELEMENT
15 Mounting Thermowell Mounted

16 Number of Wires 3 Wires

18 Diameter (*)

19 Type HART Transmitter

20 Packing Material 3 Wire Pt 100

21 Nb of Wires 2 Wire Transmitter

22 Enclosure Class Ingress Protection EEx d IIA T3 IP 66

23 Local Indicator LCD Display Required

TRANSMITTER 24 Power Supply 24 VDC Loop Powered

25 Level 4..20 mA HART


Output Signal
26 Accuracy Class 1

27 Cable Cable Gland 2x1.5 mm M20x1.5

28 Enclosure Material SS

29 Nameplate Required, Engraved with SS tag plate

30 Material 316 SS

31 Process Connection Flanged 600 RTJ 1 1/2"

32 Sensor Connection 1/2" NPT

THERMOWELL 33 Calculated Immersion Length 7".58

34 Selected Immersion Length (*)

35 External Diameter (*)

36 Construction Type Tapered

37 Certificate of Conformity Required

38 ATEX Certificate Required

39 Sour Service Certificate Not Required

MISCELLANEOUS 40 SIL Certificate Not Required

41 Leakage Test Not Required

42 Hydrostatic Test Not Required

43 Spare Parts Required for Construction, Commissioning and Start-up

44 Vendor Manufacturer (*) (*)

PURCHASE 45 Purchase Order Number Serial Number (*) (*)

46 Model Number (*)

Page 148/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE RELIEF VALVE


1 Tag Number PVRV 4450

2 Service PRESSURE RELIEF VALVE

GENERAL 3 Line Number P&ID Number - AR1602.03-PRO-DRW-008 REV01_SH16

4 Equipment Number Equipment Designation ABJ-4100 CRUDE OIL STORAGE TANK ABJ-4100

5 Location / Area CRUDE OIL STORAGE TANK ABJ-4100

6 Area Classification ZONE2

7 Fluid

8 Min Operating Max Design

9 Pressure (Barg)

10 Temperature (C)

11 Set Pressure (Barg)

12 Back Pressure (Barg)

13 Specific Heat Ratio (Cp/Cv)


PROCESS
14 Mass Density (Kg/m3)
CONDITIONS
15 Molecular Weight

16 Compressibility Factor Z

18 Flowrate to Release (Kg/h)

19 Medium to release

20 Packing Material

21 Selected Orifice Area

22 Rated Relief Capacity (Kg/h)

Page 149/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE RELIEF VALVE DATASHEET


1 Tag Number PRV4450

2 Service Pressure Relief Valve

GENERAL 3 Line Number P&ID Number X"-PG-A31X-4309 AR1602.03-PRO-DRW-008-SH 17/21

4 Equipment Number Equipment Designation NA CRUDE OIL TANK

5 Location / Area -

6 Area Classification ZONE 2

7 Required Capacity (Kg/h)

8 Molucular Weight/ Sp Gravity

9 Oper. Press(Nor/Max) Set pressure (Barg)

10 Oper. Temp(Nor/Max) Relieving Temperature (C)


PROCESS
11 Total Back Pressure Barg
CONDITIONS
12 % Allowable Overpressure

13 Compressibility Factor

14 Relief Density (Kg/m3)

15 Relief Viscosity (cP)

23 Design Safety relief

24 Type: Conventional, bellow, pilot operated Conventional

25 bonnet Type closed

26 Sizing Basis API 520

27 Calculated Area (*)

28 Selected Area (*)

29 Orifice Designation (*)

30 Rated Capacity (Kg/h) (*)

31 Calculated Noise Level (*)


TECHNICAL DATA
32 Inlet Size Inlet Class - -

33 Outlet Size Outlet Class - -

34 Body and bonnet CS

35 Nozzle and Disc CS

36 Blowdown Ring/ Locking Screw CS

37 Guide CS

38 Spring CS

39 Bellows (*)

40 Body Stud/ Bolts (*)

OTHER 41 Fire Safe as per API 6FA

42 Certificate of Conformity Required

43 ATEX Certificate HOLD

44 Sour Service Certificate Not Required

MISCELLANEOUS 45 SIL Certificate Not Required

46 Leakage Test Not Required

47 Hydrostatic Test Required

48 Spare Parts Required for Construction, Commissioning and Start-up

49 Vendor Manufacturer (*) (*)

PURCHASE 50 Purchase Order Number Serial Number (*) (*)

51 Model Number (*)

Page 150/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number PCV4701

2 Service Pressure Control Valve

GENERAL 3 Line Number P&ID Number X"-FG-A31X-4306 AR1602.03-PRO-DRW-008-SH 19/21

4 Equipment Number Location NA WATER SKIMMER AREA

5 Area Classification ZONE 2

6 Fluid GAS

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -
PROCESS
13 Calculated Cv (*)
DATA
14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Gate

23 Body Size Body Material HOLD CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream HOLD HOLD

26 Type Downstream HOLD HOLD

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic HOLD

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position HOLD

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 24VDC Instrument Air

39 Air Supply Pressure Range HOLD

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 151/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE CONTROL VALVE DATASHEET


1 Tag Number PCV4700

2 Service Pressure Control Valve

GENERAL 3 Line Number P&ID Number X"-FG-A31X-4306 AR1602.03-PRO-DRW-008-SH 19/21

4 Equipment Number Location NA WATER SKIMMER AREA

5 Area Classification ZONE 2

6 Fluid GAS

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -
PROCESS
13 Calculated Cv (*)
DATA
14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Gate

23 Body Size Body Material HOLD CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream HOLD HOLD

26 Type Downstream HOLD HOLD

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic HOLD

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position HOLD

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 24VDC Instrument Air

39 Air Supply Pressure Range HOLD

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 152/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SAFETY VALVE


1 Tag Number PSV4700

2 Service Pressure Safety Valve

GENERAL 3 Line Number P&ID Number X"-FG-A31X-4306 AR1602.03-PRO-DRW-008-SH 19/21

4 Equipment Number Equipment Designation NA WATER SKIMMER AREA

5 Location / Area ZONE 2

6 Area Classification ZONE 2

7 Fluid GAS

8 Min Operating Max Design

9 Pressure (Barg) - - - -

10 Temperature (C) - - - -

11 Set Pressure (Barg) -

12 Back Pressure (Barg) -

13 Specific Heat Ratio (Cp/Cv) -


PROCESS
14 Mass Density (Kg/m3) -
CONDITIONS
15 Molecular Weight -

16 Compressibility Factor Z -

18 Flowrate to Release (Kg/h) -

19 Medium to release -

20 Caculated Orifice Area -

21 Selected Orifice Area -

22 Rated Relief Capacity (Kg/h) -

23 Design Basis API 520

24 Valve Type Conventional

25 Relief Case Blocked Outlet

26 Body Material CS

27 Ingress Protection Class IP 54


TECHNICAL DATA
28 Trim Material SS

29 Spring Material SS

30 Type of connection Flanged

31 Inlet Size Inlet Class - -

32 Outlet Size Outlet Class - -

OTHER 33 Fire Safe as per API 6FA

34 Certificate of Conformity Required

35 ATEX Certificate HOLD

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Not Required

38 Leakage Test Not Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Model Number (*)

Page 153/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE SAFETY VALVE


1 Tag Number PSV4701

2 Service Pressure Safety Valve

GENERAL 3 Line Number P&ID Number X"-FG-A31X-4306 AR1602.03-PRO-DRW-008-SH 19/21

4 Equipment Number Equipment Designation NA WATER SKIMMER AREA

5 Location / Area ZONE 2

6 Area Classification ZONE 2

7 Fluid GAS

8 Min Operating Max Design

9 Pressure (Barg) - - - -

10 Temperature (C) - - - -

11 Set Pressure (Barg) -

12 Back Pressure (Barg) -

13 Specific Heat Ratio (Cp/Cv) -


PROCESS
14 Mass Density (Kg/m3) -
CONDITIONS
15 Molecular Weight -

16 Compressibility Factor Z -

18 Flowrate to Release (Kg/h) -

19 Medium to release -

20 Caculated Orifice Area -

21 Selected Orifice Area -

22 Rated Relief Capacity (Kg/h) -

23 Design Basis API 520

24 Valve Type Conventional

25 Relief Case Blocked Outlet

26 Body Material CS

27 Ingress Protection Class IP 54


TECHNICAL DATA
28 Trim Material SS

29 Spring Material SS

30 Type of connection Flanged

31 Inlet Size Inlet Class - -

32 Outlet Size Outlet Class - -

OTHER 33 Fire Safe as per API 6FA

34 Certificate of Conformity Required

35 ATEX Certificate HOLD

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Not Required

38 Leakage Test Not Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Model Number (*)

Page 154/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 28/11/2016

Project: EPF-CPF Construction

PRESSURE SWITCH DATASHEET


1 Tag Number PSHH4700

2 Service Pressure Switch High High

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 19/21

4 Equipment Number Location MBD4400 WATER SKIMMER AREA

5 Area Classification ZONE 2

6 Fluid GAS

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Switch Type SPDT/SNAP

13 Set point (Barg) HOLD

14 Setting Trip Factory Set

15 Operating Range

16 Process Connection Class 600#

18 Housing Material Aluminum

19 Enclosure Class Ingress Protection HOLD IP54


SWITCH
20 Packing Material 2x1.5 mm

21 Power supply 24 VDC

22 Contact Arrangement 2NO/2NC

23 Cable Gland M20x1.5

24 External Adjustment Required

25 Accuracy (*)

26 Mounting On pipe

27 Manifold 2 Valve Manifold

28 Manifold Material SS

MANIFOLD 29 Inlet 1/2" NPTF

30 Manifold End Connections Outlet 1/2" NPTM

31 Drain 1/4" NPT

32 Local Display Not Required

33 Mounting Brackets Required


OPTIONS
34 Sun Shade Not Required

35 LED Indication Not Required

36 Certificate of Conformity Required

37 ATEX Certificate Not Required

38 Sour Service Certificate Not Required

MISCELLANEOUS 39 SIL Certificate Not Required

40 Leakage Test Not Required

41 Hydrostatic Test Not Required

42 Spare Parts Required for Construction, Commissioning and Start-up

43 Vendor Manufacturer (*) (*)

PURCHASE 44 Purchase Order Number Serial Number (*) (*)

45 Model Number (*)

Page 155/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR TRANSMITTER DATASHEET


1 Tag Number PIT4700

2 Service Pressure Indicator Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 19/21

4 Equipment Number MBD4400

5 Location / Area WATER SKIMMER AREA

6 Area Classification ZONE 2

7 Fluid GAS

8 Min Operating Max Design


PROCESS
9 Pressure (Barg) - - - -
CONDITIONS
10 Temperature (C) - - - -

11 Mass Density (Kg/m3) -

12 Instrument Range -

13 Element Type Diaphragm


ELEMENT
14 Element Material SS

15 Number of wires 2 wire sensor

16 Indicator Scale LCD Type Required (*)

18 Process Connection Electrical Connection 1/2" NPT M20x1.5

19 Power Supply Load Resistance 24 VDC Loop Powered (*)


TRANSMITTER
20 Packing Material 4..20 mA HART

21 ATEX Rating Ingress Protection EEx d IIA T3 IP 54

22 Accuracy Repeatability 0.05% (*)

23 Manifold 2-way valve : Isolation + vent + Drain


MANIFOLD
24 Size and Rating Inlet 1/2" NPTM x Outlet 1/2" NPTM ; Drain 1/4" NPTF ANSI Class 3000#

25 Certificate of Conformity Required

26 ATEX Certificate HOLD

27 Sour Service Certificate Not Required

MISCELLANEOUS 28 SIL Certificate Not Required

29 Leakage Test Not Required

30 Hydrostatic Test Not Required

31 Spare Parts Required for Construction, Commissioning and Start-up

32 Vendor Manufacturer (*) (*)

PURCHASE 33 Purchase Order Number Serial Number (*) (*)

34 Model Number (*)

Page 156/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI4700

2 Service Pressure Indicator

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008 SH 19/21

4 Equipment Number Location - WATER SKIMMER AREA

5 Area Classification ZONE 2

6 Fluid GAS

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg) - - - -

9 Temperature (C) - - - -

10 Range -

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS
GAUGE DETAILS
15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP54

21 Connection Flanged

22 Bottom Housing Material SS

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge Threaded 1/2" NPT

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 157/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 28/11/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSLL4700

2 Service Pressure Switch Low Low

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 19/21

4 Equipment Number Location MBD4400 WATER SKIMMER AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

8 Pressure (Barg) - - - -
PROCESS
9 Temperature (C) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point HOLD HOLD

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Process Connection Class 2" 600#

20 Body Material SS
SWITCH
21 Float Material SS

22 Enclosure Class Ingress Protection HOLD IP54

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 158/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 28/11/2016

Project: EPF-CPF Construction

DUAL CHAMBER LEVEL GAUGE/TRANSMITTER DATASHEET


1 Tag Number LG 4700/LIT4700

2 Service Level Gauge/Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 19/21

4 Equipment Number Location MBD4400 WATER SKIMMER AREA

5 Area Classification ZONE 2

6 Fluid WATER

7 Min Operating Max Design

8 Temperature (C) - - - -
PROCESS
9 Pressure (Barg) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Specific Gravity -

12 Viscosity -

13 Instrument Type Dual chamber

14 Gauge Type Glass

15 Connections Center to Center Distance HOLD

16 Tube Material Glass

GAUGE 17 Size 2"


End Connection
18 Type Flanged 2", 600# RTJ

19 Body Material (*)

20 Cover Material SS

21 Mounting Side Mounted

22 Type Guided wave Radar

SENSOR 23 Insertion Depth HOLD

24 Material SS

25 Indicator Required

26 Output 2 wires, 4..20 mA

27 Reliability HOLD

TRANSMITTER 28 Mounting Integral

29 Power Supply Loop Powered 24 VDC

30 Enclosure Class HOLD

31 Cable Gland HOLD

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 159/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 28/11/2016

Project: EPF-CPF Construction

LEVEL TRANSMITTER DATASHEET


1 Tag Number LIT4701

2 Service Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 19/21

4 Equipment Number Location MBD4400 WATER SKIMMER AREA

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

8 Temperature (C) - - - -
PROCESS
9 Pressure (Barg) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Specific Gravity -

12 Viscosity -

13 Instrument Type NA

14 Gauge Type NA

15 Connections Center to Center Distance NA

16 Tube Material NA

GAUGE 17 Size NA
End Connection
18 Type NA

19 Body Material NA

20 Cover Material NA

21 Mounting NA

22 Type Guided wave Radar

SENSOR 23 Insertion Depth HOLD

24 Material SS

25 Indicator Required

26 Output 2 wires, 4..20 mA

27 Reliability HOLD

TRANSMITTER 28 Mounting Integral

29 Power Supply Loop Powered 24 VDC

30 Enclosure Class HOLD

31 Cable Gland HOLD

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 160/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 28/11/2016

Project: EPF-CPF Construction

LEVEL SWITCH DATASHEET


1 Tag Number LSHH4700

2 Service Pressure Switch High High

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 19/21

4 Equipment Number Location MBD4400 WATER SKIMMER

5 Area Classification ZONE 2

6 Fluid PRODUCED WATER

7 Min Operating Max Design

8 Pressure (Barg) - - - -
PROCESS
9 Temperature (C) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Viscocity (Cp) -

13 Switch Type Float Operated Level Switch

14 Set point HOLD HOLD

15 Setting Trip Factory Set

16 Insertion Length (*)

17 Operating Pressure Operating Temperature (*) (*)

18 Process Connection Class 2" 600#

20 Body Material SS
SWITCH
21 Float Material SS

22 Enclosure Class Ingress Protection HOLD IP54

23 Power supply 24 VDC

24 Contact Arrangement 2NO/2NC

25 Cable Gland M20x1.5

26 External Adjustment Required

27 Accuracy (*)

28 Local Display Not Required

29 Mounting Brackets Required


OPTIONS
30 Sun Shade Not Required

31 LED Indication Not Required

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 161/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 28/11/2016

Project: EPF-CPF Construction

SHUTDOWN VALVE DATASHEET


1 Tag Number SDV4700

2 Service Shutdown Valve

GENERAL 3 Line Number P&ID Number X"-PW-A31X-4700 AR1602.03-PRO-DRW-008-SH 19/21

4 Equipment Number Location - WATER SKIMMER AREA

5 Area Classification ZONE 2

6 Fluid PRODUCED WATER

7 Min Operating Max Design


PROCESS
8 Pressure (Barg) - - - -
DATA
9 Temperature (C) - - - -

10 Mass Density (Kg/m3) -

11 Type Ball Valve

12 Body Size Port Size 4" Full Bore

13 Maximum Pressure Maximum Temperature (*) (*)

14 Body Material CS

15 Fire Safe YES


VALVE BODY
16 Class Size Flanged RF 150# 4"
CHARACTERISTICS Process Connection Type
17 Downstream Flanged 4" 150# RF

18 Type of Bonnet Bolted

19 Lubrication Lube Type Required (*)

20 Packing Material PTFE

21 Bolting Material CS

22 Type Trunnion Mounted

23 Size Rated Travel (*) (*)

TRIM 24 Service ON / OFF Valve


CHARACTERISTICS 25 Ball Material SS

26 Seat Insert PTFE

27 Stem Material SS

28 Type Pneumatic and Pinion Spring Return

29 Size (*)

30 Fail Position Closed


ACTUATOR
31 Max. Operating Pressure Max. Allowable Pressure (*) (*)
CHARACTERISTICS
32 Stroking Time Torque 10 sec (*)

33 Handwheel Not Required

34 Safety Factor 100%

35 Tag Number SDY4700

36 Type 3-way Valve

37 Input Signal 24 VDC

SOLENOID VALVE 38 Fluid Instrument Air

39 SIL Enclosure/ATEX Class - IP54 -

40 Body Size Body Material (*) (*)

41 Connection Type Cable Gland (*) M20x1.5

42 Quantity Type NA NA

43 Tag Number NA NA
LIMIT SWITCH
44 Designation NA NA

45 Enclosure Class Cable Gland NA NA

UTILITIES 46 Fluid Pressure Instrument Air -

49 ATEX Certificate Sour Service Certificate Required Required

50 SIL Certificate Leakage Test Required Required

MISCELLANEOUS 51 Spare Parts Required for Construction, Commissioning and Start-up

52 Vendor Manufacturer (*) (*)

53 Purchase Order Number Serial Number (*) (*)

Page 162/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE INDICATOR DATASHEET


1 Tag Number PI4701

2 Service Pressure Indicator

GENERAL 3 Line Number P&ID Number 2"-PO-A11X-3403 AR1602.03-PRO-DRW-008 SH 19/21

4 Equipment Number Location - WATER SKIMMER AREA

5 Area Classification ZONE 2

6 Fluid PRODUCED WATER

PROCESS 7 Min Operating Max Design


DATA 8 Pressure (Barg) - - - -

9 Temperature (C) - - - -

10 Range -

11 Element Type Bourdon Tube

12 Element Material Pointer Material SS Aluminum

13 Process Connection Connector Position Threaded 1/2" NPT From the Bottom

14 Socket/Connector Material SS
GAUGE DETAILS
15 Dial Size Scale 160 mm Barg/PSI

16 Case Material Lens Material SS Laminated glass

18 Over Pressure Limit 130%

19 Nominal Accuracy 0,1 %

20 Packing Material IP54

21 Connection Flanged

22 Bottom Housing Material SS

23 Fill Fluid (*)

DIAPHRAGM SEAL 24 Process Connection (*) (*)

25 Allowable Temp. For fill Fluid (*)

26 Top Housing Material (*)

27 Connection to gauge Threaded 1/2" NPT

28 Siphon Type Siphon Material Pigtail SS

29 Snubber Type Snubber Material Adjustable SS


OPTIONS
30 Manifold Required (2-way Valve Manifold)

31 Nameplate Required (SS Engraved tag plate)

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Not Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 163/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

DIFFERENTIAL PRESSURE INDICATOR DATASHEET


1 Tag Number DPI4700

2 Service Differential pressure indicator

GENERAL 3 Line Number P&ID Number 2"-PO-A11X-3402 AR1602.03-PRO-DRW-008 SH 3/21

4 Equipment Number Location - WATER SKIMMER AREA

5 Area Classification ZONE 2

6 Fluid GAS

7 Min Operating Max Design

8 Temperature (C) - - - -

PROCESS 9 Pressure (Barg) - - - -


DATA 10 Flowrate (Kg/h) -

11 Density (Kg/m3) -

12 Molecular Weight -

13 Viscosity -

14 Meter Type Integral Orifice Plate Flowmeter

15 Orifice Shape -

16 Bore Diameter (*)


METER
17 Upstream length Downstream Length 10 D 5D

18 Size & Type 2" RF


End Connections
19 Class 150#

20 Power Supply 24 VDC Loop Powered

21 Output Signal 4..20 mA


TRANSMITTER
22 Enclosure Class HOLD

23 Cable Gland HOLD

24 Manifold 5-valve manifold (2x1/4" Drain Screws + 2x1/2" Isolation Screws / 1x1/2" Equalizer)

25 Manifold Material SS
ACCESSORIES
26 Inlet 2x1/2" NPTM
Manifold End Connections
27 Outlet 2x1/2" NPTM

28 LCD Indicator Not Required

29 Certificate of Conformity Required

30 ATEX Certificate HOLD

31 Sour Service Certificate Not Required

MISCELLANEOUS 32 SIL Certificate Not Required

33 Leakage Test Not Required

34 Hydrostatic Test Required

35 Spare Parts Required for Construction, Commissioning and Start-up

36 Vendor Manufacturer (*) (*)

PURCHASE 37 Purchase Order Number Serial Number (*) (*)

38 Model Number (*)

Page 164/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL CONTROL VALVE DATASHEET


1 Tag Number LCV4700

2 Service Level Control Valve

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 19/21

4 Equipment Number Location - WATER SKIMMER AREA

5 Area Classification ZONE 2

6 Fluid PRODUCED WATER

7 Min Operating Max Design

8 Temperature (C) - - - -

9 Pressure Drop (Bar) - - - -

10 Inlet Pressure (Barg) - - - -


3
11 Liquid (m /h) - - - -
Flow rate
12 Gas (Kg/h) - - - -
PROCESS
13 Calculated Cv (*)
DATA
14 Noise Level (dBA) (*)

15 Design Temperature (C) Design Pressure (Barg) - -

16 Max. Vapor Pressure (Bara) -

18 Inlet -
Line Size & Shedule
19 Outlet -

20 Packing Material CS

21 Selected Cv (*)

22 Valve Type Ball

23 Body Size Body Material HOLD CS

24 Fire Safe YES

VALVE BODY 25 End Connection Size & Upstream HOLD HOLD

26 Type Downstream HOLD HOLD

27 Packing Material (*)

28 Bolting Material SS

29 Size (*)

30 Flow to CLOSE
TRIM
31 Disk Material Seat Material SS (*)

32 Characteristic HOLD

33 Type Diaphragm

ACTUATOR 34 Size (*)

35 Fail Position HOLD

36 Positioner Air Set Electropneumatic Required

37 Gauge Required
ACCESSORIES
38 Input Signal Output Signal 24VDC Instrument Air

39 Air Supply Pressure Range HOLD

40 Certificate of Conformity Required

41 ATEX Certificate Required

42 Sour Service Certificate Not Required

MISCELLANEOUS 43 SIL Certificate Required

44 Leakage Test Required

45 Hydrostatic Test Required

46 Spare Parts Required for Construction, Commissioning and Start-up

47 Vendor Manufacturer (*) (*)

PURCHASE 48 Purchase Order Number Serial Number (*) (*)

49 Valve Model Number Actuator Model Number (*) (*)

Page 165/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE RELIEF VALVE DATASHEET


1 Tag Number PRV4500

2 Service Pressure Relief Valve

GENERAL 3 Line Number P&ID Number X"-PG-A31X-4309 AR1602.03-PRO-DRW-008-SH 17/21

4 Equipment Number Equipment Designation NA CRUDE OIL TANK

5 Location / Area -

6 Area Classification ZONE 2

7 Required Capacity (Kg/h)

8 Molucular Weight/ Sp Gravity

9 Oper. Press(Nor/Max) Set pressure (Barg)

10 Oper. Temp(Nor/Max) Relieving Temperature (C)


PROCESS
11 Total Back Pressure Barg
CONDITIONS
12 % Allowable Overpressure

13 Compressibility Factor

14 Relief Density (Kg/m3)

15 Relief Viscosity (cP)

23 Design Safety relief

24 Type: Conventional, bellow, pilot operated Conventional

25 bonnet Type closed

26 Sizing Basis API 520

27 Calculated Area (*)

28 Selected Area (*)

29 Orifice Designation (*)

30 Rated Capacity (Kg/h) (*)

31 Calculated Noise Level (*)


TECHNICAL DATA
32 Inlet Size Inlet Class - -

33 Outlet Size Outlet Class - -

34 Body and bonnet CS

35 Nozzle and Disc CS

36 Blowdown Ring/ Locking Screw CS

37 Guide CS

38 Spring CS

39 Bellows (*)

40 Body Stud/ Bolts (*)

OTHER 41 Fire Safe as per API 6FA

42 Certificate of Conformity Required

43 ATEX Certificate HOLD

44 Sour Service Certificate Not Required

MISCELLANEOUS 45 SIL Certificate Not Required

46 Leakage Test Not Required

47 Hydrostatic Test Required

48 Spare Parts Required for Construction, Commissioning and Start-up

49 Vendor Manufacturer (*) (*)

PURCHASE 50 Purchase Order Number Serial Number (*) (*)

51 Model Number (*)

Page 166/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

TEMPERATURE INDICATOR DATASHEET


1 Tag Number TI/TW4500

2 Service Temperature Indicator

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 17/21

4 Equipment Number Location AJB-4200 CRUDE OIL TANK

5 Area Classification ZONE 2

6 Fluid Multiphase Crude Oil

7 Min Operating Max Design

PROCESS 8 Pressure (Barg) - - - -


DATA 9 Temperature (C) - - - -
3
10 Mass Density (Kg/m ) -

11 Flowrate (Kg/h) -

12 Type Bi-Metal

13 Range -

14 Stem Type Threaded

15 Stem Material SS

THERMOMETER 16 Stem Length Stem Diameter (*) (*)

18 Window Material Case Material Shatter Proof SS

19 Stem Connection 1/2" NPT

20 Packing Material IP 54

21 Accuracy 1 %

22 Material 316 SS

23 Process Connection THREADED 1/2" NPT

THERMOWELL 24 Calculated Immersion Length 7".58

25 Selected Immersion Length (*)

26 Construction Type Tapered

27 Certificate of Conformity Required

28 ATEX Certificate Not Required

29 Sour Service Certificate Not Required

MISCELLANEOUS 30 SIL Certificate Not Required

31 Leakage Test Not Required

32 Hydrostatic Test Not Required

33 Spare Parts Required for Construction, Commissioning and Start-up

34 Vendor Manufacturer (*) (*)

PURCHASE 35 Purchase Order Number Serial Number (*) (*)

36 Model Number (*)

Page 167/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

PRESSURE RELIEF VALVE DATASHEET


1 Tag Number PVRV4500

2 Service Pressure Relief Valve

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 17/21

4 Equipment Number Equipment Designation AJB-4200 CRUDE OIL TANK

5 Location / Area -

6 Area Classification ZONE 2

7 Required Capacity (Kg/h)

8 Molucular Weight/ Sp Gravity

9 Oper. Press(Nor/Max) Set pressure (Barg)

10 Oper. Temp(Nor/Max) Relieving Temperature (C)


PROCESS
11 Total Back Pressure Barg
CONDITIONS
12 % Allowable Overpressure

13 Compressibility Factor

14 Relief Density (Kg/m3)

15 Relief Viscosity (cP)

23 Design Safety relief

24 Type: Conventional, bellow, pilot operated Conventional

25 bonnet Type closed

26 Sizing Basis API 520

27 Calculated Area (*)

28 Selected Area (*)

29 Orifice Designation (*)

30 Rated Capacity (Kg/h) (*)

31 Calculated Noise Level (*)


TECHNICAL DATA
32 Inlet Size Inlet Class - -

33 Outlet Size Outlet Class - -

34 Body and bonnet CS

35 Nozzle and Disc CS

36 Blowdown Ring/ Locking Screw CS

37 Guide CS

38 Spring CS

39 Bellows (*)

40 Body Stud/ Bolts (*)

OTHER 41 Fire Safe as per API 6FA

42 Certificate of Conformity Required

43 ATEX Certificate HOLD

44 Sour Service Certificate Not Required

MISCELLANEOUS 45 SIL Certificate Not Required

46 Leakage Test Not Required

47 Hydrostatic Test Required

48 Spare Parts Required for Construction, Commissioning and Start-up

49 Vendor Manufacturer (*) (*)

PURCHASE 50 Purchase Order Number Serial Number (*) (*)

51 Model Number (*)

Page 168/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

LEVEL TRANSMITTER DATASHEET


1 Tag Number LIT4500

2 Service Level Transmitter

GENERAL 3 Line Number P&ID Number NA AR1602.03-PRO-DRW-008-SH 17/21

4 Equipment Number Location AJB-4200 CRUDE OIL TANK

5 Area Classification ZONE 2

6 Fluid GAS

7 Min Operating Max Design

8 Temperature (C) - - - -
PROCESS
9 Pressure (Barg) - - - -
DATA
3
10 Mass Density (Kg/m ) -

11 Specific Gravity -

12 Viscosity -

13 Instrument Type Dual chamber

14 Gauge Type Glass

15 Connections Center to Center Distance HOLD

16 Tube Material Glass

GAUGE 17 Size 2"


End Connection
18 Type Flanged 2", 600# RTJ

19 Body Material (*)

20 Cover Material SS

21 Mounting Side Mounted

22 Type Guided wave Radar

SENSOR 23 Insertion Depth HOLD

24 Material SS

25 Indicator Required

26 Output 2 wires, 4..20 mA

27 Reliability -

TRANSMITTER 28 Mounting Integral

29 Power Supply Loop Powered 24 VDC

30 Enclosure Class -

31 Cable Gland -

32 Certificate of Conformity Required

33 ATEX Certificate Not Required

34 Sour Service Certificate Not Required

MISCELLANEOUS 35 SIL Certificate Not Required

36 Leakage Test Not Required

37 Hydrostatic Test Required

38 Spare Parts Required for Construction, Commissioning and Start-up

39 Vendor Manufacturer (*) (*)

PURCHASE 40 Purchase Order Number Serial Number (*) (*)

41 Model Number (*)

Page 169/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

BLOWDOWN VALVE DATASHEET


1 Tag Number BDV XXXX

2 Service Blowdown Valve

GENERAL 3 Line Number P&ID Number 6"-PG-C31X-4331 AR1602.03-PRO-DRW-008-SH 11/21

4 Equipment Number Location - EXPORT GAS HEADER

5 Area Classification ZONE 2

6 Fluid Phase Liquid

7 Min - - -

8 Operating Presure (Barg) Operating -

PROCESS 9 Maximum -
DATA 10 Design Pressure (Barg) -

11 Operating Temperature (C) -

12 DesignTemperature (C) -

13 Max Differential Presure (Bar) -

14 Valve Type Ball

15 BodyType Body Material Bore (*) CS (*)

16 Body Material CS

17 Process Connection Size & Upstream HOLD HOLD

18 Type Downstream HOLD HOLD

19 Stem Material SS

20 Bolting/Nut Material SS
TECHNICAL DATA
21 Size (*)

22 Flow to CLOSE

23 Disk Material Seat Material SS (*)

24 Input Signal Output Signal 24VDC Instrument Air

25 Solenoid Valve Electrical Connection NA

26 Limit Switch Electrical Connection NA

27 Tubing Size (*)

28 Type Diaphragm

29 Sizing Standard (*)

30 Fail Position Fail to Close


ACTUATOR
31 Open/Close Indicator Not Required

32 Orientation -

33 Supply (*)

34 Certificate of Conformity Required

35 ATEX Certificate Required

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Required

38 Leakage Test Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Valve Model Number Actuator Model Number (*) (*)

Page 170/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

BLOWDOWN VALVE DATASHEET


1 Tag Number BDV4000

2 Service Blowdown Valve

GENERAL 3 Line Number P&ID Number X"-PG-A31X-4011 AR1602.03-PRO-DRW-008-SH 3/21

4 Equipment Number Location - -

5 Area Classification ZONE 2

6 Fluid Phase GAS

7 Min - - -

8 Operating Presure (Barg) Operating -

PROCESS 9 Maximum -
DATA 10 Design Pressure (Barg) -

11 Operating Temperature (C) -

12 DesignTemperature (C) -

13 Max Differential Presure (Bar) -

14 Valve Type Ball

15 BodyType Body Material Bore (*) CS (*)

16 Body Material CS

17 Process Connection Size & Upstream HOLD HOLD

18 Type Downstream HOLD HOLD

19 Stem Material SS

20 Bolting/Nut Material SS
TECHNICAL DATA
21 Size (*)

22 Flow to CLOSE

23 Disk Material Seat Material SS (*)

24 Input Signal Output Signal 24VDC Instrument Air

25 Solenoid Valve Electrical Connection M20x1,5

26 Limit Switch Electrical Connection NA

27 Tubing Size (*)

28 Type Diaphragm

29 Sizing Standard (*)

30 Fail Position Fail to Close


ACTUATOR
31 Open/Close Indicator Not Required

32 Orientation -

33 Supply (*)

34 Certificate of Conformity Required

35 ATEX Certificate Required

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Required

38 Leakage Test Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Valve Model Number Actuator Model Number (*) (*)

Page 171/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

BLOWDOWN VALVE DATASHEET


1 Tag Number BDV4100

2 Service Blowdown Valve

GENERAL 3 Line Number P&ID Number X"-PG-A31X-4061 AR1602.03-PRO-DRW-008-SH 4/21

4 Equipment Number Location - -

5 Area Classification ZONE 2

6 Fluid Phase GAS

7 Min - - -

8 Operating Presure (Barg) Operating -

PROCESS 9 Maximum -
DATA 10 Design Pressure (Barg) -

11 Operating Temperature (C) -

12 DesignTemperature (C) -

13 Max Differential Presure (Bar) -

14 Valve Type Ball

15 BodyType Body Material Bore (*) CS (*)

16 Body Material CS

17 Process Connection Size & Upstream HOLD HOLD

18 Type Downstream HOLD HOLD

19 Stem Material SS

20 Bolting/Nut Material SS
TECHNICAL DATA
21 Size (*)

22 Flow to CLOSE

23 Disk Material Seat Material SS (*)

24 Input Signal Output Signal 24VDC Instrument Air

25 Solenoid Valve Electrical Connection M20x1,5

26 Limit Switch Electrical Connection NA

27 Tubing Size (*)

28 Type Diaphragm

29 Sizing Standard (*)

30 Fail Position Fail to Close


ACTUATOR
31 Open/Close Indicator Not Required

32 Orientation -

33 Supply (*)

34 Certificate of Conformity Required

35 ATEX Certificate Required

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Required

38 Leakage Test Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Valve Model Number Actuator Model Number (*) (*)

Page 172/173
EMCO Ref AR1602.03-INS-DSH-003 REV00

INSTRUMENTS DATASHEETS Date 07/12/2016

Project: EPF-CPF Construction

BLOWDOWN VALVE DATASHEET


1 Tag Number BDV4200

2 Service Blowdown Valve

GENERAL 3 Line Number P&ID Number X"-PG-A31X-4110 AR1602.03-PRO-DRW-008-SH 5/21

4 Equipment Number Location - -

5 Area Classification ZONE 2

6 Fluid Phase GAS

7 Min - - -

8 Operating Presure (Barg) Operating -

PROCESS 9 Maximum -
DATA 10 Design Pressure (Barg) -

11 Operating Temperature (C) -

12 DesignTemperature (C) -

13 Max Differential Presure (Bar) -

14 Valve Type Ball

15 BodyType Body Material Bore (*) CS (*)

16 Body Material CS

17 Process Connection Size & Upstream HOLD HOLD

18 Type Downstream HOLD HOLD

19 Stem Material SS

20 Bolting/Nut Material SS
TECHNICAL DATA
21 Size (*)

22 Flow to CLOSE

23 Disk Material Seat Material SS (*)

24 Input Signal Output Signal 24VDC Instrument Air

25 Solenoid Valve Electrical Connection M20x1,5

26 Limit Switch Electrical Connection NA

27 Tubing Size (*)

28 Type Diaphragm

29 Sizing Standard (*)

30 Fail Position Fail to Close


ACTUATOR
31 Open/Close Indicator Not Required

32 Orientation -

33 Supply (*)

34 Certificate of Conformity Required

35 ATEX Certificate Required

36 Sour Service Certificate Not Required

MISCELLANEOUS 37 SIL Certificate Required

38 Leakage Test Required

39 Hydrostatic Test Required

40 Spare Parts Required for Construction, Commissioning and Start-up

41 Vendor Manufacturer (*) (*)

PURCHASE 42 Purchase Order Number Serial Number (*) (*)

43 Valve Model Number Actuator Model Number (*) (*)

Page 173/173