You are on page 1of 2

PHASED ARRAY INSPECTION PRELIMANARY REPORT

Procedure No.: GSOP 2014 Revision 00


Client KNPC-MAB Report No. Stork/AUT/009/2017

Unit Unit-20 Date 18-04-2017

VESSEL No. 205 PA Equipment TD-HANDY(RX-0121)

Services COCKE DRUM Scanned Length 25.2 Meter

NOM. THICK. 30 MM +3.2 MM(Clad) Material A-387 GR II

Probe Dia & Frequency : Phased Array 5L32 A11 (5 MHz)

Cable Length & Type : 2.5 mtr. D78 Connector

Couplant : Water + Wall Paper paste

Type of scanning : Manual Contact Method sectorial scan (40


degree to 70 degree)

Phased Array Sensitivity : Dia 1.5 mm SDH at 62mm Depth

Scanning Sensitivity : Ref. dB + 6 dB

Scanning details and Results:

PAUT Weld scanning was carried out for seam C-3 of Vessel-202

In Seam C-3, indications observed as per attached sheet.


.
Tested By Approved By

Name Vikas Chandra ( PAUT & TOFD Level-II)


Sign

Date 17-04-2017
Indications observed in Seam C-3

INDICATION LOCATION LENGTH DEPTH THROUGH TYPE


HEIGHT
1 0 +2410 60MM 27 MM < 2 MM Linear

2 0 +4420 18MM 27 MM < 2 MM Linear

3 0 +5660 65 MM 27 MM < 2 MM Linear

4 180 +2200 32 MM 29 MM < 2 MM Linear

5 270+1180 60MM 29 MM < 2 MM Linear

6 270+5190 20MM 29 MM < 2 MM Linear

You might also like