You are on page 1of 1

PATELS RADIOGRAPHY SERVICES

C/o. Maa Bhagwati Metal Treatment, Survey No. 256, Plot No. 87/108, Nr. Jaydeep Chemical,
Shapar - Veraval, Ta. Kotada Sangani, Dist. Rajkot (Gujarat)
An ISO certified company Mobile : +91 9506550647,8905444119 Email : patelsradiography0510@gmail.com

RADIOGRAPHY TEST REPORT


Customer Name & Address : Report No. : 10939/19-20
INVENT CAST PVT. LTD. Date : 12/01/2020
G-561,ROAD-1G Job Desc. : 25MM FB #300 BALL VALVE
Kishan Gate BODY
GIDC Lodhika Die No. : 6238
Metoda Drawing No. : 12-20-05-304C REV.02
RAJKOT 360 003 Heat No. : K318M
Gujarat, India Sr.No./RT No. : RT 183
RSS No. :-

Party : WS No. & Dt.: 0651/10-01-2020


PO No. : Technique : DWSI
Job : Casting Material : ASTM A216 GR. WCB
Test Carried Out at : OUR SITE RT Coverage : ASME B 16.34 (CRITICAL AREA)
Radiation Source : IR-192 Film : CARESTRAEM AA400
Exposure Time : 8 MIN Screen : Lead
Processing Time : 4 TO 5 MIN Lead Th. (F) : 0.125MM
Source/Focal Spot Size : 2.7DX1.5H Lead Th. (B) : 0.250MM
Source Strength : 14.92 Viewing : SINGLE

Procedure Ref. : ASME SEC-V, Article 2 & 22


Eveluation as per : ASTM E-446(VOL.II)
Accepatable Std. : ASME B16.34 APPENDIX-1,2017

Sr. Thick. Density Sensi- SFD


Identification / Location Film Size I. Q. I. Observation Remarks
No. (MM) Min Max tivity (inch)

1 A 6"X6" 7+7 2.0 4.0 ASTM 15 S 2-4T 24 NSD Accepted


2 B 6"X6" 7+7 2.0 4.0 ASTM 15 S 2-4T 24 NSD Accepted

DENSITY OF FILMS MEASURED AND CONFORMED TO BE BETWEEN 2.0 TO 4.0 Note :


NSD=No Significant Discontinuity, A=Gas Porosity, B=Inclusion, CA;CB;CC;CD=Shrinkage, (1) Report related only to items tested.
D=Crack, E=Hot Tears, F=Insert, SD=Surface Depression, G=Mottling (2) Test results are in compliance with requirements and / or
specifications of the technique.
Date of Testing : 10/01/2020 (3) Test Report shall not be reproduce except in full without written
Film Size : 6"X6" - 2 approval of the laboratory.
Total No. of Films : 2 Nos.
Total Sq. Inches : 72.000

For, PATELS RADIOGRAPHY SERVICES Customer Client External Inspector


*** END OF REPORT *** Page 1 of 1