NDT EDDY CURRENT INSPECTION REPORT

Report No: CAT-ECI-19-035 Page No.


Item Description: PAD EYE Location/Area: RIGGING LOCKER#7 1 of 3
Date: 29/07/19 M 310B FAN ROOM (AFT)

Costumer Details:
Costumer : UNIVERSAL ENERGY RESOURCE, INC Project No: TBA
Rig/Installation: SSV CATARINA
Offshore Location: BALIKPAPAN OFFSHORE

Description of Items/Inspected Areas:


Material: Carbon Steel Surface Condition: Smooth and Clean Visual Condition: Good
Coating: Yes Examination Part: Welds & HAZ Areas Standart: BSEN 1711:2000
Temperature: Ambient Preparation Method: N/A Qty: 1 ea

Equipment & Inspection Technique:


Equipment & S/N: Ether / 503438-02 Phase Angle: 186 Mode : Normal Single
Probe Type &S/N: Bridge / 503375/02 Frequency: 100 kHz Load µH: 8.2 µ
Calibration Expiry: 19-Mar-2020 Gain: 43 dB dB: + 2 dB

Insp. Technique: Single Frequency Calibration Blok Sensitivity Setting


Method: 2.5 cm / sec speed Made & S/N: ATBW & 401511/80 Sensitivity: 1 mm Slot @ FSH
Acceptance Criteria: BSEN 1711:2000 Coating: 1.5 mm

Reason of Inspection:
Periodic Survey Special Survey Following Service After repair Remarks:

Has the item been dismantled correctly as per owner requirement?


Yes No Partially Not required Remarks:

Inspection Result
Detail Inspection Serial No ID No. Max Weight Qty Drawing Reference No:

Welding Areas of Pad Eyes N/A M310-D05 2 Ton 1 ea N/K

Pictures

Pad Eye M 310-D05

Inspector Comment:

NDT inspection was carried out on welds and HAZ areas as shown in the above pictures and accessible with probe.

Inspection Result: Remarks:


Acceptable as per spesification
Status OK No indication of crack at the time of inspection
Un-acceptable as per spesification and NOT FIT FOR SERVICE
Inspector, Client and Third Party Acknowledgment
NDT Inspector: Donny Saputra Client Representative: Andrii Korenevych Third Party:
Qualification: ECI Level 2 Signature: Name:
Signature: Date: Signature:

OHI-FOP-16 Rev.00 Printed: 01 May 2018

Create PDF files without this message by purchasing novaPDF printer (http://www.novapdf.com)
NDT EDDY CURRENT INSPECTION REPORT

Report No: CAT-ECI-19-035 Page No.


Item Description: PAD EYE Location/Area: RIGGING LOCKER#7 2 of 3
Date: 29/07/19 M 310B FAN ROOM (AFT)

Costumer Details:
Costumer : UNIVERSAL ENERGY RESOURCE, INC Project No: TBA
Rig/Installation: SSV CATARINA
Offshore Location: BALIKPAPAN OFFSHORE

Description of Items/Inspected Areas:


Material: Carbon Steel Surface Condition: Smooth and Clean Visual Condition: Good
Coating: Yes Examination Part: Welds & HAZ Areas Standart: BSEN 1711:2000
Temperature: Ambient Preparation Method: N/A Qty: 1 ea

Equipment & Inspection Technique:


Equipment & S/N: Ether / 503438-02 Phase Angle: 186 Mode : Normal Single
Probe Type &S/N: Bridge / 503375/02 Frequency: 100 kHz Load µH: 8.2 µ
Calibration Expiry: 19-Mar-2020 Gain: 43 dB dB: + 2 dB

Insp. Technique: Single Frequency Calibration Blok Sensitivity Setting


Method: 2.5 cm / sec speed Made & S/N: ATBW & 401511/80 Sensitivity: 1 mm Slot @ FSH
Acceptance Criteria: BSEN 1711:2000 Coating: 1.5 mm

Reason of Inspection:
Periodic Survey Special Survey Following Service After repair Remarks:

Has the item been dismantled correctly as per owner requirement?


Yes No Partially Not required Remarks:

Inspection Result
Detail Inspection Serial No ID No. Max Weight Qty Drawing Reference No:

Welding Areas of Pad Eyes N/A M310-D04 2 Ton 1 ea N/K

Pictures

Pad Eye M310-D04

Inspector Comment:

NDT inspection was carried out on welds and HAZ areas as shown in the above pictures and accessible with probe.

Inspection Result: Remarks:


Acceptable as per spesification
Status OK No indication of crack at the time of inspection
Un-acceptable as per spesification and NOT FIT FOR SERVICE
Inspector, Client and Third Party Acknowledgment
NDT Inspector: Donny Saputra Client Representative: Andrii Korenevich Third Party:
Qualification: ECI Level 2 Signature: Name:
Signature: Date: Signature:

OHI-FOP-16 Rev.00 Printed: 01 May 2018

Create PDF files without this message by purchasing novaPDF printer (http://www.novapdf.com)
NDT EDDY CURRENT INSPECTION REPORT

Report No: CAT-ECI-19-035 Page No.


Item Description: PAD EYE Location/Area: RIGGING LOCKER#7 3 of 3
Date: 29/07/19 M 310B FAN ROOM AFT

Drawing

Port

AFT FWD

STBD

M 310B FAN ROOM (AFT)


RIGGING LOCKER #7

M310-D03
SWL 2T

M310-D01
SWL 2T

M310-D02
SWL 2T

M 310 FAN ROOM

M310-D05 M310-D04
SWL 2T SWL 2T

Certified Pad Eye (ECI/MPI)


Certified Pad Eye (Visual)
Uncertified Pad Eye
Location : M 310B Fan Room (AFT)
Drawing No : OHI/LGICAT/009
Vessel Name : SSV CATARINA Job Description : LIFTING GEAR INSPECTION (INITIAL SURVEY)
Drawn by : DONNY SAPUTRA LEEA Inspector : ERA S. SIBARANI PT. OFFSHORE HYDRAULICS INDONESIA

Scale : NOT TO SCALE Date : 29 JULY 2019