You are on page 1of 1

ULTRASONIC EXAMINATION REPORTPage 1

LARSEN & TOUBRO LIMITED


HAZIRA MANUFACTURING COMPLEX
Project :: 45769/2 EO Reactor Customer : RELIANCE INDUSTRIES LIMITED

Seam : R8599 Stage : N5KUTCOM Seq.No : 58 Report Iteration Sample Date


UT OF COMPLETED WELD 4184859 1 1 01-02-2014

Insp.Agn. :L&T Base Material & Thickness Procedure No. Seam Length Joint Type
TPI 1 :LRA Carbon Steel 22.00 24800.00 (mm) BUILDUP
TPI 2 : Carbon Steel 22.00 Tech.Sheet No. Seam OD UT Ext.
TPI 3 : 0.00 BUILD UP 0.000(m) 100%

Surface Cond. : Welders HA5 HDT HX3 Drawing No. : H02-5769-10


As welded Welding Process : SAW

Manufacturing Code :ASME SEC VIII,DIV.1.Ed.2010 ADD. 2011 Applicable Specification


Welding Remarks :#QL-4/SA745M OF ASME SEC II PART "A" SWRP-45769-2-NCR-8599 & SA-388

Seam/Part Desc. Acceptance Standard


Lip buildup APP 12/ASME SEC VIII DIV. 1#

M/C Make & Model : MODSONIC EINSTEIN Srl No.: 173

Search Unit : SEB4 MWB45 4


Make : KRAUTKRAMER KRAUTKRAMER
Serial No : 57745 38433 0 0
Frequencyin Mhz: 4 4
Element Size : TR 6 X 20 mm 8 X 9 MM
Beam Angle in °: 0 45 0 0 COUPLANT Scanning Details
Ref gain in dB : 64 48 Paste All possible Sides
Ref. Reflector : Back Wall 2.5 MM SDH DGS Scanning Tech
Range in mm : 50 50 0 0 No Contact Manual
CableTypeLength: MPKL-2 MPKL-2
%Amp/BP in mm(Ind1) 80/ 23 80/ 7 0/ 0 0/ 0 Reject Control Rec Ind. at Ref Gain
%Amp/BP in mm(Ind2) 0/ 0 72/ 13 0/ 0 0/ 0 OFF = & > 50%PRL
%Amp/BP in mm(Ind3) 0/ 0 42/ 20 0/ 0 0/ 0
%Amp/BP in mm(Ind4) 0/ 0 12/ 32 0/ 0 0/ 0 Damping Ind. Data Sheet is
LOW Enclosed? Yes / No
Transfer Correction : No Points: 0 Av. dB: 0 After Test Cal. Rechecked ? :Yes

Clibrtn Blck Idntfication Simulation Block Identification Scanning Sensitivity


V1 (IIW) Parent Material + 06 dB

Any Special Accessories Used : Yes/No Test Location : Dt of Exmntion Seam Cleared ?
NDT Remarks: :
Areas of Restricted Access or Inaccessible Welds : NA 01.02.2014 Yes

Sl. Spot Number Spot Result Details Defect Result Remarks Any Recordable Indication? Yes / No
No. ( 305.00 mm) Status Length * If 'Yes', Attach Datasheet

1 1-2 R 0 0 Cleared 1-2 TO 82-1 SPOTS ARE CLEARED.


* End of Report *

Carried Out By Reviwed & Approved By Witnessed/Reviewed By Witnessed/Reviewed By


L&T LII LII / III

Initials Initials TPI 1 / AI TPI 2 / 3

You might also like