You are on page 1of 4

TECHNOKING NDT SERVICES

Ghetia Estate -B, Near Uday Paper Mill, Opp. Pal Auto, Shapar (Veraval), Rajkot-360 024
E-Mail- technokingndt@yahoo.com, 85116 20501,7600648888
RADIOGRAPHY TESTING REPORT
Client : DELTA TECHNOCAST PVT.LTD. Report No . :
Job Description : 50MM 2PC ADAPTOR F/E 300# Date :
Material : LCB Date of Testing:
Die /Tool No. : 161 Offer No. :
Drawing No. : -- Outwork DC No.:

Heat No. : I098L Test Carried Out At : Our Test Lab

Radiation Source : Ir-192 Source Strength : 18 Ci Source Size : 2.7 mmDx1.5mmH


Film Type : D7 Lead Screen : 0.1 mm Exposure Time : 10 Min.
Film Processing : Manual Film Density : 1.5 to 4.0 Developing Time : 3 TO 5 min
RT Coverage Area : B16.34 Evaluation Standard :ASTM E-446 (VOL.II)
Procedure Follow : ASME SEC V, Arti. 2 Acceptance Standard:ASME B16.34 App-1
Sr. Thik. SFD Technique Film Size Sens-
No. Identification Segment IQI
(mm) (Inch) (Inch) itivity Findings
1 V801L A 12+12 24" DWSI 6X7.5 1B/17 2-4T NSD
2 B 12+12 24" DWSI 6X7.5 1B/17 2-4T NSD
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Total No. of Film: 2
Total Sq. Inch : 90
Film Size Summary : 6X7.5=2
Density of each film is measured and confirm between 1.5-4.0
(NSD=No Significant Discontinuity, A=Gas Porosity, B=Inclusion, CA;CB;CC;CD=Shrinkage, D=Crack, E=Hot Tears,F=Insert, SD=Surface
Depression
Note:
1. Report relates items tested only
2. Test Result are in complience with requirement and/or specification of technique used.
3. Test Report shall not be reproduced except full in written approval of the laboratory
Inspector Signature: Customer's Signature: Third Party Signature:
KAUSHIK USDAD
ASNT Level II (RT)
60 024

TNS/DTPL/4417/19-20

12/19/2019
12/17/2019
385

d Out At : Our Test Lab

mmDx1.5mmH
Min.
TO 5 min
6 (VOL.II)
34 App-1

Results

ACCEPTABLE
ACCEPTABLE

ears,F=Insert, SD=Surface

Signature:

You might also like