Pump Selection 1
Pump Selection 1
DISCHARGE PIPE
Discharge Pipe Length 130.0 ft
Equivalent Length of Pipe Fittings 35.0 ft (see tables) =============================>
Discharge Pipe Inside Diameter 3.00 in
Hazen-Williams Roughness, C 130 ==========================> Hazen-Williams
Material C
Other Losses 0.0 ft Brass 130
Cast Iron 100
Concrete 100
Copper 130
Static Head 12.9 ft Fiberglass 150
Total Discharge Pipe Length 165.0 ft (includes equivalent length of fittings) PE, no joints 150
PVC 130
Steel, Smooth 100
Pump Manufacturer Goulds Steel, Spiral 90
Pump Model # WS15D3 Steel, CMP 60
Note: Velocity will increase as static head pressure (acting against the pump) decreases
Pump & System Curves
60
Pump System
51.3
50
Head, feet
40 40.3
38
34
31.0
30 30
26
23.6
22
20
17.9
16
14.3
12.9
10 10
0
0 50 100 150 200 250 300
Flow, gallons per minute
POWER REQUIREMENTS
Hydraulic Power 1.0 WHP (net energy transferred to the fluid)
0.8 WkW (net energy transferred to the fluid)
COST OF ELECTRICITY
Cost per kW-hr $0.100 Dollars
Hours used 1.0 Hours
Total Cost $0.15 Dollars