You are on page 1of 1

Solids Retention Time (SRT)

Calculation Worksheet
Wastewater Permit Program
Doc Type: Course Material

Directions: Date calculated:


Input numbers - yellow boxes
Output calculation - green boxes
SRT - orange box

1. Size of aeration tank

Length 60 feet Width 175 feet Water Depth 15 feet Volume 1.178100 MG

2. Size of Clarifier

Diameter 85 feet Water Depth 12 feet Volume 0.509085 MG

3. Total Volume of Aeration tank and Clarifier

1.687185 MG

4. MLSS or MLVSS Concentration

3450 mg/L

5. Waste Sludge Concentration

6230 mg/L

6. Waste Sludge Flow

0.08400 MGD

7. Effluent TSS Concentration

15 mg/L

8. Average Wastewater Flow 9. Calculated SRT 10.29 Days

2.83 MGD

wq-wwtp7-39 2/26/13 www.pca.state.mn.us 651-296-6300 800-657-3864 TTY 651-282-5332 or 800-657-3864 Available in alternative formats Page 1 of 1