Professional Documents
Culture Documents
Sanitary/Plumbing Works
Project :
NBF Consulting Engineers
Subject : Designed By : Checked By : nbf
SIZING OF SEPTIC TANK
Date : Date :
Where:
FB = 0.3 m.
SWD = D + FB
= 1.8 + 0.3
= 2.1 m.
DC-1 = L x W x D
= 6 x 1.5 x 2.5
DC-1 5.8205 x 4.5 x 1.8 =
Vol = 22.5 42.86% DC-2 3.8799 x 4.5 x 1.8 =
LC 3.8799 x 4.5 x 1.8 =
DC-2 = L x W x D 13.58
= 4 x 1.5 x 2.5
Vol = 15 28.57%
LC = L x W x D
= 4 x 1.5 x 2.5
Vol = 15 28.57%
Find L
DC-1 = L x W x D
= 6.1 x 1.5 x 1.8
Vol = 16.5547 43%
DC-2 = L x W x D
= 4.1 x 1.5 x 1.8
Vol = 11.0352 29%
LC = L x W x D
= 4.1 x 1.5 x 1.8
Vol = 11.0352 29%
Total = 38.625 m3 100%
L x W x D
DC-1 = 6.1 x 1.5 x 2.1
DC-2 = 4.1 x 1.5 x 2.1
LC = 4.1 x 1.5 x 1.8
54.75
107.25
42.9
44.025
=
47.15 43%
31.43 29%
31.43 29%
110
Project Scope
Population 100 households
550 persons
Ave. Water Consumption 130 lpcd
Total Consumption 71500 liters/day
71.5 cu.m./day
WW Generation 57200 liters/day
57.2 cu.m./day
Septic Tank Size 44025 liters/day
44.025 cu.m./day