You are on page 1of 17

PUMP PRODUCTS GUIDE

TORISHIMA PUMPMFG. CO., LTD


Innovative solutions coupled with
expertise in pumping technology TORISHIMA
TORISHIMA is a leading pump manufacturer, founded in 1919 in Osaka, Japan. Our primary objective is to contribute to
MAIN PUMPS
society as a quality provider of pumping equipment and services. We continue to strive to be the market leader in our field.
Our on-going investment in research and development highlights our commitment to provide the best technology for our
SELECTION TABLE General specification ranges for 50Hz
and 60Hz types are shown below.

customers. Our mission is always to listen to our customers, understand their needs and their expectations.

Pumps for Fresh Water

4,000

3,000
MHG
2,000
MHB
1,500
1,200
MHD

Total head H m
850
MSH MSH-T
500
400
250 MML CDM

100
MMO CDKTV
50 MMK

30
CFV
10 SPV
CA Series CE
5
ISV
0.2 5 10 20 30 100 300 500 700 1000 1500 2500 3500
Capacity Q m3/min

Chemical Process Pumps Hot Water Circulating Pumps


300 35.0

Discharge pressure MPa(kgf/cm2)G


HLV,HLAV
CPR
10.0

Total head H m
200 CPC CHR
5.0 CPW
CPR
CPCN
100 CA Series
1.5
CERS

0.1 20 40 60 80 0.1 5 20 30 50 70 100


Capacity Q m3/min Capacity Q m3/min

Non-Clogging Pumps Vertical Pumps for Chemical Industries

100 500
CNP MMTV
Main Pumps List
Content 300
End-Suction Pumps .............................................. 15
Total head H m

Total head H m
60 CNA
Torishima Main Pumps Selection Table.................. 2 Double-Suction Pumps ......................................... 19 100
Multi-Stage Pumps ............................................... 20 CSV
Chart for Selecting Pumps by Application
Energy Industry....................................................... 3 Specialized Pumps ............................................... 22 20
Municipal Water Works, Industrial Water Works Mixed-Flow Pumps ............................................... 23
Small Capacity Water Works, Desalination Plant ... 5 Axial-Flow Pumps ................................................. 24 0.1 5 10 15 0.1 10 15 40 50
Sewerage, Agriculture, Irrigation, River Water ....... 7 Submersible Pumps.............................................. 25 Capacity Q m3/min Capacity Q m3/min
Regional Development, Urban Development ......... 9 Miscellaneous Pumps ........................................... 27
2
Chemical Industry ................................................. 11 Mechanical Seals..................................................... 29
General Industry ................................................... 13 Service Solutions .................................................... 30
Condensate pump for combined cycle power plant (MMTV)
Energy Industry Vaporizing pumps for LNG plant (SPV)
Barrel type super critical boiler feed pump for coal fired power plant (MHB)
Super critical pressure boiler circulating pump for thermal power plant (HLV)
Ring section boiler feed pump for combined cycle power plant (MHG)
Circulating water pump for coal fired thermal power plant (SPV)
Main Application Horizontal Vertical Horizontal/Vertical
Chart for Selecting Pumps by Application Secondary Application Horizontal Vertical Horizontal/Vertical

Applications

MPa
mm

m3/h

C
Underground

Ground Tank
Generation

Oil Storage

Max. Operating Temperature


Power

Tank

Max. Operating Pressure


Gas

Max. Total Heads


Water Drainage

Max. Capacities
Underground

Fire-Fighting
Hydropower

Geothermal

Oil Product
Seawater
Cooling by
LNG, LPG

Crude oil
Stripping
Outlet
Utility

Utility

Sizes

Page
Coal

LNG
Products

Oil
32 to
CAL 200
600 100 1 80 15

32 to
CAM 250
1200 150 1 80 15

200 to
CE 300
2100 90 1 140 15

50 to
CHR 300
1940 125 10.8 325 16

End- CNP
50 to
850 100 1 250 17
200
Suction 32 to
Pumps CPC 250
1560 220 2.45 350 17

32 to
CPCN 250
1560 150 2.45 200 18

25 to
CPR 400
4320 270 4 400 18

40 to
CPW 250
1440 200 6.3 280 18

32 to
CSV 200
810 100 2.5 350 18

200 to
CDM, CDMV 1400
33000 300 1.4 80 19

Double- 200 to
CDKS 500
3000 300 350 19
Suction 125 to
Pumps CDKY 400
3480 160 3.2 210 19

500 to
CDKTV 1500
20000 100 100 19

80 to
MHB 200
2000 4200 42 200 20

40 to
MHG 250
1400 4200 42 200 20

Multi- 80 to
MHD 200
300 1200 14 180 20
Stage 40 to
Pumps MMK 350
1800 150 5.4 230 21

40 to
MML 350
1800 500 5.4 230 21

40 to
MMTV 400
2900 490 3.9 200 22

40 to
Specialized HLV, HLAV 400
6000 180 32 420 22

Mixed-Flow SPV 300 to


80000 100 80 23
Pumps 2800
150 to
SMRV 1000
9000 70 25
Sub-
50 to
mersible T/B 800
4800 40 40 26
Pumps 25 to
F/TB 200
400 200 26

3 4
Water supply pumps for potable water distribution pumping station (CDM)
Municipal Water Works Long-distance potable water transmission pumps (CDM)
Brine recirculation pumps for MSF desalination plant (CDKTV)
Industrial Water Works Various seawater pumps for MSF desalination plant (CDM, SPV, SPSY)
High pressure seawater feed pump for RO desalination plant (MSH-T)
Small Capacity Water Works High pressure seawater feed pump for RO desalination plant (MSH)
Main Application Horizontal Vertical Horizontal/Vertical
Desalination Plant Chart for Selecting Pumps by Application Secondary Application Horizontal Vertical Horizontal/Vertical

Applications

MPa
m3/h

C
mm
Desalination

Desalination
Waterworks

Waterworks

Waterworks
Small Scale
MunicipaI

Seawater

Seawater

Max. Operating Temperature


IndustriaI

(MSF)

(RO)

Max. Operating Pressure


Max. Total Heads
Brine Blow Down

Max. Capacities
Seawater Feed

Product Water

Product Water
Recirculation

High Pressure

Filtered Water

Back Wash
Distribution
Supply

Feed
Intake

Sizes

Page
Brine
Products
32 to
CAL 300
600 100 1 80 15

32 to
CAR 200
600 100 1 80 15

End- CAM
32 to
1200 150 1.6 80 15
250
Suction
32 to
Pumps CAS 250
1200 150 1.6 80 15

150 to
CFV 5000
210000 100 16

32 to
CPC 250
1560 220 2.45 350 17

200 to
CDM, CDMV 1400
33000 300 1.4 80 19
Double-
200 to
Suction CDKS 500
3000 300 350 19
Pumps 500 to
CDKTV 1500
20000 100 100 19

100 to
MSH 300
1500 750 21

200 to
MSH-T 350
3000 800 21

150 to
MHH 300
800 800 21
Multi-
125 to
Stage MHA 200
800 800 21

Pumps 40 to
MMK 350
1800 150 5.4 230 21

40 to
MML 350
1800 500 5.4 230 21

32 to
MMO, MMOV 65
130 400 4 140 22

300 to
Mixed- SPV 2800
80000 100 80 23
Flow
350 to
Pumps SPSY 1200
20000 50 23

400 to
SMIV 700
4500 6 25

400 to
SMSV 700
4200 14 25
Sub-
150 to
mersible SMV 1000
9000 70 25

Pumps 25 to
F/TB 250
400 200 26

F/VC, F/VD 40 to
660 90 26
F/UW, F/SP 300

5 6
Storm water drainage pumps for sewage treatment plant (SPV)
Sewerage Drainage pumps for agriculture (SP)
Irrigation pumps (CDM)
Agriculture Sludge transfer pumps for sludge disposal plant (CNP)
Waste water transfer pumps for sewage treatment plant (CFV-SM)
Irrigation Sewage pumps for sewage treatment plant (CFV)
Main Application Horizontal Vertical Horizontal/Vertical
River Water Chart for Selecting Pumps by Application Secondary Application Horizontal Vertical Horizontal/Vertical

Applications

MPa
m3/h

C
mm
River Water
Agriculture
Sewerage

Max. Operating Temperature


Max. Operating Pressure
Irrigation, Sprinkler

Max. Total Heads


Sewage Transfer

Agricultural Water

Water Utilization

Max. Capacities
Disposal Plant

Disposal Plant

Small Capacity

FIood Control,
Water Supply
Storm Water

Sewerage
Drainage

Drainage
Sewage

Sludge
Plant

Sizes

Page
Products
32 to
CAL 300
600 100 1 80 15

32 to
CAM 250
1200 150 1.6 80 15

200 to
CE 300
2100 90 1 140 15

End- 150 to
CFV 5000
210000 100 16
Suction 200 to
Pumps CFV-SM 600
3000 50 16

50 to
CNA 200
500 70 1 140 17

50 to
CNP 250
850 100 1 250 17

80 to
CNS, CNSV 250
660 70 105 17

Double-Suction 200 to
Pumps CDM, CDMV 1400
33000 300 1.4 80 19

100 to
MSH 300
1500 750 21

200 to
MSH-T 350
3000 800 21
Multi-
40 to
Stage MMK 350
1800 150 5.4 230 21

Pumps 40 to
MML 350
1800 500 5.4 230 21

32 to
MMO, MMOV 65
130 400 4 140 22

400 to
SP 2000
36000 9 23

Mixed- 300 to
SPV 2800
80000 100 80 23
Flow 350 to
Pumps SPSY 1200
20000 50 23

250 to
SPSX 350
1380 17 24

Axial- 400 to
IS 2000
36000 5 24
Flow 400 to
Pumps ISV 4600
186000 5 24

400 to
SMI, SMS 5000
210000 8 25

400 to
SMIV 700
4500 6 25

Sub- 400 to
SMSV 700
4200 14 25
mersible 50 to
Pumps T/B, T/C, T/N 800
4800 40 40 26

25 to
F/TB 200
400 200 26

F/VC, F/VD 40 to
660 90 26
F/UW, F/SP 300
Miscellaneous 400 to
Pumps SNK 3500
18000 10 28

7 8
Pumps for air conditioning system for building facility (CAL)
Regional Development Cooling water pumps for district heating and cooling system (CDM)
Boiler feed pumps for district heating and cooling system (MML)
Urban Development Cooling water pumps for district heating and cooling system (CDM)
Cooling water pumps for air conditioning facility (CE)
Boiler feed pumps for district heating and cooling system (MMO)
Main Application Horizontal Vertical Horizontal/Vertical
Chart for Selecting Pumps by Application Secondary Application Horizontal Vertical Horizontal/Vertical

Harbor Facilities

Park and Resort


Applications

District Heating

MPa
mm

m3/h

C
and Cooling

Airport and

Facilities
Intelligent

Max. Operating Temperature


Building

Max. Operating Pressure


Max. Total Heads
Supply Water, Raw Water
Drainage, Sanitation

Max. Capacities
Air Conditioning

Vacuum Supply Water,


Water Supply and

Cooling Water

Water Supply

Water Supply
Fire-Fighting

Boiler Feed

Treatment

Treatment
Cold Water

Hot Water

Fountains
Drainage

Drainage
Sewage

Sewage

Sizes

Page
Products
32 to
CAL 200
600 100 1 80 15

32 to
CAR 200
600 100 1 80 15

32 to
CAM 250
1200 150 1.6 80 15

32 to
CAS 250
1200 150 1.6 80 15

End- 200 to
CE 300
2100 90 1 140 15
Suction 32 to
Pumps CEBS 65
42 65 1 100 16

50 to
CNA 200
500 70 1 140 17

32 to
CPC 250
1560 220 2.45 350 17

32 to
CPCN 250
1560 150 2.45 200 18

Double-Suction 200 to
Pumps CDM, CDMV 1400
33000 300 1.4 80 19

40 to
MMK 350
1800 150 5.4 230 21
Multi-
40 to
Stage MML 350
1800 500 5.4 230 21
Pumps 32 to
MMO, MMOV 65
130 400 4 140 22

50 to
T/B, T/C, T/N 800
4800 40 40 26
Sub-
25 to
mersible F/TB 200
400 200 26
Pumps F/VC, F/VD 40 to
660 90 26
F/UW, F/SP 300
25 to
K/LP 100
84 60 100 27

Miscel- N/WR 15 to
72 300 90 27
80
laneous
25 to
Pumps TE/O 200
300 40 40 28

40 to
S/T 150
600 75 1 80 28

9 10
Process pumps for chemical plant (CPC)
Chemical Industry Process pumps for DMT plant (CPC)
Cooling water pumps for petrochemical plant (CDM)
Boiler feed pump for petrochemical plant (MHD)
Lifting pump for chemical plant (CDKS)
Cooling water pumps for oil refinery plant (CPC)
Main Application Horizontal Vertical Horizontal/Vertical
Chart for Selecting Pumps by Application Secondary Application Horizontal Vertical Horizontal/Vertical

Petro-Chemical
Applications

MPa
mm

m3/h

C
Fine-Chemical

Bio-Chemical

Oil and Coal


Chemical

Products
Fertilizer

Max. Operating Temperature


Chemical
Inorganic

Max. Operating Pressure


Max. Total Heads
Coal Conversion

Max. Capacities
Refinery
Process

Process

Process

Process

Process
Utility

Utility

Utility

Utility

Utility

Sizes

Page
Products
32 to
CAL 200
600 100 1 80 15

32 to
CAR 200
600 100 1 80 15

32 to
CAM 250
1200 150 1.6 80 15

32 to
CAS 250
1200 150 1.6 80 15

200 to
CE 300
2100 90 1 140 15

End- 32 to
CERS 100
300 98 1.4 340 16
Suction 50 to
Pumps CNP 250
850 100 1 250 17

32 to
CPC 250
1560 220 2.45 350 17

32 to
CPCN 250
1560 150 2.45 200 18

25 to
CPR 400
4320 270 4 400 18

40 to
CPW 250
1440 200 6.3 280 18

32 to
CSV 200
810 100 2.5 350 18

Double- CDM 200 to


33000 300 1.4 80 19
1400
Suction 200 to
Pumps CDKS 500
3000 300 350 19

80 to
MHB 200
2000 4200 42 200 20

40 to
MHG 250
1400 4200 42 200 20

Multi- 80 to
MHD 200
300 1200 14 180 20
Stage 40 to
Pumps MMK 350
1800 150 5.4 230 21

40 to
MML 350
1800 500 5.4 230 21

40 to
MMTV 400
2900 490 3.9 200 22

Mixed-Flow 300 to
Pumps SPV 2800
80000 100 80 23

Submersible 50 to
Pumps T/B, T/C, T/N 800
4800 40 40 26

Miscellaneous 15 to
Pumps N/WR 80
72 300 90 27

11 12
Water supply pumps for machinery plant (CAL)
General Industry Treated water pumps for beverage plant (CAR)
Process pumps for beer brewery plant (CAR)
Furnace cooling water pump for steel plant (CDM)
Cooling water pump in paper mill (CDM)
Plating cooling water pumps for steel plant (CAL)
Main Application Horizontal Vertical Horizontal/Vertical
Chart for Selecting Pumps by Application Secondary Application Horizontal Vertical Horizontal/Vertical

Applications

MPa
m3/h

C
mm
Paper & Pulps
New Materials
Iron and Steel

Shipbuilding
Nonferrous

Machinery
Motor Car

Max. Operating Temperature


Ceramics
Metal

Max. Operating Pressure


Food

Max. Total Heads


Max. Capacities
Dock Drainage
Cooling Water
Water Supply

Water Supply
Water Intake,

Waste Water
Treatment
Descaling

Drainage

Process

Process
Utility

Utility

Utility

Sizes

Page
Products
32 to
CAL, CAR 200
600 100 1 80 15

32 to
CAM, CAS 250
1200 150 1.6 80 15

200 to
CE 300
2100 90 1 140 15

32 to
CEBS 65
42 6.5 1 100 16

32 to
CERS 100
300 98 1.4 340 16
End-
50 to
Suction CNA 200
500 70 1 140 17

Pumps 50 to
CNP 200
850 100 1 250 17

80 to
CNS, CNSV 250
660 70 105 17

32 to
CPC 250
1560 220 2.45 350 17

32 to
CPCN 250
1560 150 2.45 200 18

40 to
CPW 250
1440 200 6.3 280 18

Double-Suction 200 to
Pumps CDM 1400
33000 300 1.4 80 19

40 to
MHG 250
1400 4200 42 200 20

80 to
MHD 200
300 1200 14 180 20
Multi-
40 to
Stage MMK 350
1800 150 5.4 230 21

Pumps 40 to
MML 350
500 1800 5.4 230 21

32 to
MMO, MMOV 65
130 400 4 140 22

40 to
Specialized HLV/HLAV 400
6000 180 32 420 22

Mixed-Flow 300 to
Pumps SPV 2800
80000 100 80 23

40 to
S/M 350
1000 230 26

Sub- 50 to
T/B, T/C, T/N 800
4800 40 40 26
mersible 25 to
Pumps F/TB 200
400 200 26

F/VC, F/VD 40 to
660 90 26
F/UW, F/SP 300
15 to
N/WR 80
72 300 90 27
Miscel-
25 to
laneous TE/O 200
300 40 40 28

Pumps 50 to
O/PS 250
780 70 28

13 14
End-Suction
End-Suction

End-Suction Pumps CEBS 80


5 20 USgpm 80 100 300

200
Pressing stainless end-suction volute pump 50

100

A motor block pump made by pressing stainless 50


10
steel. The liquid contact areas are all made of 30
stainless steel so as to be highly resistant to H H
m ft
corrosion. The pump motor unit design allows to
10
be compact and light-weight and easy to handle.
2

Applications 1
0.2 1 Q l/s 5 25
Hot water supply / Hot water circulation 1 Q m3/h 10 20 90
in building facilities,
Various processes in food industries, Capacity 3
up to 42 m /h / 165 USgpm
Water and hot water supply for general industries, Total Head up to 65 m / 210 ft
To prevent breakage from freezing for pump Temperature up to 100C / 210F
Pressure up to 1 MPa / 10 bar / 145 psi
facilities in cold areas, and others
Size 32 to 65 mm

CAL (Cast Iron), 150


20 100 USgpm 1000 4000 6000
490
CERS 55 200 USgpm 2000 4000
300

CAR (Stainless Steel) 100 100


300 End-suction volute pump for heat
transfer oil 50

100
10bar end-suction volute pump 30 100

H H Specialized for heat transfer oil. H


m ft m
Taking advantage of our existing pump designs, Effective air-cooled design leads to no requirement H
20 ft
CAL and CAR are totally optimized design pumps 5
for cooling at shaft sealing or bearing to 340C
which adopt the efficient impeller design. The heat transfer oil. 5

components focus on interchangeability. 2 5


10

0.8 2 Q l/s 20 200 350


Applications 2
3.3 10 Q l/s 100
Applications 10 Q m3/h 50 100 500 9001400 Dry / Agitator / Heating systems Q m3/h
12 50 100 500 1000
Feed / Drainage water for general industries, Feed / for chemical industries,
Capacity up to 600 m3/h / 2,640 USgpm Oven / Dry / Heating systems for food industries, Capacity 3
Drainage water / Various processes for chemical / up to 300 m /h / 1,320 USgpm
Total Head up to 100 m / 320 ft Dry / Heating systems for general industries, and Total Head up to 98 m / 320 ft
food industries, Cold / Hot water circulation in district Temperature -10 to 80C / -50 to 170F
heating / cooling plants, Water pumping, others Temperature up to 340C / 640F
Pressure up to 1 MPa / 10 bar / 145 psi Size 32 to 100 mm
Fire-fighting, Water intake / Distribution / Supply for Size 32 to 200 mm
water works, Industrial water, and others

CAM (Cast Iron), 150


100
20 100 USgpm 1000 4000 6500
490

300
CFV, CFV-SM 500
100
20000 USgpm 200000 1000000
300
Vertical mixed-flow volute pump
CAS (Stainless Steel) 30 100
Vertical mixed-flow volute pump with motor 50

100
16bar end-suction volute pump H H
m ft Applicable for wide range from low head to high H CFV
50
m CFV-SM
In common with CAL and CAR as CA series, CAM 20 head. CFV-SM are a design of water resistant
5 H
and CAS are totally optimized design pumps which motor and pump. The design enables it to ft
adopt the efficient impeller design. operate when a pump room is flooded. In 5
5
2 addition, CFV-SM doesnt require intermediate 10
0.8 2 Q l/s 20 200 350
Applications Q m3/h
shaft and thus reduces construction cost. 2
10 50 100 500 9001500 30 500 Q l/s 5000 20000
Feed / Drainage water for general industries, Feed / 100 2000 Q m3/h 20000 50000 200000 CFV
Drainage water / Various processes for chemical / Capacity up to 1,200 m3/h / 5,280 USgpm Applications
food industries, Cold / Hot water circulation in district Total Head up to 150 m / 490 ft Sewage transfer, Rain water drainage, Water CFV CFV-SM
heating / cooling plants, Water pumping, Temperature -40 to 80C / -100 to 170F intake / Distribution / Boosting for water works, Capacity 120 to 210,000 m3/h / 520 to 924,000 USgpm 180 to 3,000 m3/h / 790 to 13,200 USgpm
Fire-fighting, Water intake / Distribution / Supply for Pressure up to 1.6 MPa / 16 bar / 230 psi Water pumping / Drainage for agriculture, and Total Head 3 to 100 m / 10 to 320 ft up to 50 m / 160 ft
water works, Industrial water, and others Size 32 to 250 mm others Size 150 to 5,000 mm 200 to 600 mm

CE 100
20 100 USgpm 500 2000 10000

400
CHR 150
50 200 USgpm 1000 5000

End-suction volute pump 80 End-suction volute pump for hot 100 300

water circulation H
50
100 ft
A single- or two-stage end-suction volute pump.
20 100
Various materials and structural designs employed 50 Applicable mainly for hot water circulation of H
m
to meet specification requirements for a variety of H forced-circulation boilers. The forced cooling
m H
applications from fresh water, chemicals and heat ft
system is applied to the bearing bracket, stuffing 50

transfer. 5 box and base plate. 10


5
20
Applications 2
1.2 10 Q l/s 100 650
Applications 5
2 5 20 Q l/s 100 500
Water intake / Distribution / Supply / Boosting / 10 40 Q m3/h 400 2000 Hot water circulation in forced-circulation boilers 10 50 Q m3/h 500 1500
Clarification for water works, in thermal power plants,
3
Various processes for chemical industries, Capacity up to 2,100 m /h / 9,240 USgpm Petrochemical industries, Capacity 3
up to 1,940 m /h / 8,530 USgpm
Water pumping / Drainage for agriculture, Total Head up to 90 m / 295 ft Coal gasification plants, Total Head up to 125 m / 410 ft
up to 140C / 280F (340C / Oil refinery, and others Temperature up to 325C / 615F
Boiler feed pump, Temperature
640F for heat medium) Pressure up to 10.8 MPa / 108 bar / 1,560 psi
Heat medium circulation, Pressure up to 1 MPa / 10 bar / 145 psi Size 50 to 300 mm
Heater drain, and others Size 200 to 300mm

15 16
End-Suction

End-Suction
CNA 80
40 100 USgpm 500 1000 2000
250 CPCN 200
10 100 USgpm 1000 7000

Non-clogging end-suction volute pump End-suction volute pump for process 150 500
30 100
300
H
The discharge opening of the non-clogging m
50 Conforms to ISO2858, compact, durable and 50

impeller is produced especially wide to permit free 10


reliable based on CPC type. The design corre- H
100

passing of any solids measuring 50 to 70% of the H sponding to space saving installation and high m 50
ft
pump nozzle size. suction pressure fits in building facilities, district
4 H
cooling and heating, energy related industries. 5
ft
Applications 10

Sewage transfer, 2
2.5 10 Q l/s 25 50 120 170 Applications 0.5 5
0 5 Q l/s 50 500
Transfer / Drainage of liquids containing sludge 10 50 Q m3/h 100 200 500 Cooling water circulation in building facilities, Cool / 3 20 Q m3/h 200 1800
for general industries, Hot water / Cooling water circulation for district
Transfer of grain and water mixtures, Capacity 9500 m3/h / 39 to 2,200 USgpm
cooling and heating, Water pumping, Fire-fighting, Capacity up to 1,560 m3/h / 6,860 USgpm
Total Head up to 70 m / 230 ft
Transfer of cellulous pulp of less than 2.5% B.D. Cooling systems / Water feed for deaerator / Total Head up to 150 m / 490 ft
Temperature up to 140C / 280F
free from air, and others Condensate / Drain in energy industries, Water Temperature -40 to 200C / -100 to 390F
Size 50 to 200mm
feed / Drainage for general industries Pressure up to 2.45 MPa / 24.5 bar / 355 psi
Size 32up to 250 mm

CNP 55 200 USgpm 2000 4000 CPR 300


100 USgpm 1000 10000

1000

400
Non-clogging End-suction volute pump 100 End-suction volute pump for process 500
100
50
H 200
Five kinds of standardized impellers available m
100 Simple and durable design providing high H
30
according to liquid. Applicable in various H reliability. Widely used for oil refinery, petro- ft

industries. The back pull-out structure and high m chemical, and general industries. Series with 50
H
interchangeability of this pump providing ease of ft inducer for low NPSH req. also available. 10
maintenance. 5
20

10
Applications 3
Applications 2
Processes in oil refinery / petrochemical / general 1 10 Q l/s 100 1200
10 100 Q m3/h 1000 4000
Transfer of corrosive liquids / abrasive liquids / 3.3 10 Q l/s 100 270 industries
Q m3/h
chemical drainage including rough mixtures 12 50 500 960
Capacity up to 4,320 m3/h / 19,000 USgpm
for chemical industries, Capacity up to 850 m3/h / 3,740 USgpm Total Head up to 270 m / 885 ft
Transfer / Drainage of solid mixtures for food / Total Head up to 100 m / 320 ft Temperature -70 to 400C / - 150 to 750F
general industries, and others Temperature -30 to 250C / -20 to 480F Pressure up to 4 MPa / 40 bar / 580 psi
Size 50 to 200mm Size 25 to 400 mm

CNS, CNSV(Vertical) 100


30 300 USgpm 3000
CPW 300
10 50 USgpm 500 5000

End-suction volute pump with screw 200 End-suction volute pump for hot water 500

impeller circulation 100


H
H ft
30 100
m
H H 30 100
Specially designed to handle crude sewage m ft Centerline pump foot mounted. Mainly used as
containing heavily contaminated solid and feed pump or circulation pump of hot water in
10 30
long-fibre admixtures liable to twist or bunch. large-size heating systems. 10 30

High efficiency and high energy saving.


Applications 3 10
Applications 3 Feed water / Circulation in high pressure hot
0 Q l/s 20 200 600 0.35 1 5 Q l/s 20 100 500
Sewage / Sludge transfer, 10 Q m3/h 100 1000
water generating plants 2 5 Q m3/h 25 100 500 2000
Pulp / Black liquid / White liquid transfer,
Transfer / Drainage of solid mixtures in food / Capacity 3
up to 660 m /h / 2,900 USgpm Capacity up to 1,440 m3/h / 6,300 USgpm
general industries, and others Total Head up to 70 m / 230 ft Total Head up to 200 m / 670 ft
Temperature up to 105C / 220F Temperature up to 280C / 530F
Size 80 to 250 mm Pressure up to 6.3 MPa / 63 bar / 910 psi
Size 40 to 250 mm

CPC 300
200
10 100 USgpm 1000 7000

700
CSV 100
60 100 USgpm 300 1000 2000 6000

End-suction volute pump for process Vertical centrifugal volute pump 200
50
300
100
50 H
Conforms to ISO2858. A wide range of structural Standardized vertical pump, making full use of m
100
designs of material and seals meet various H the features of various horizontal volute pumps 50

specification requirements as process pump for m 50 covering a wide range of specifications. 10 H


chemical and general industries. H
ft
5
ft Applications 15
Applications Pumping / Drainage of pit water in construction
Cooling systems / Water feed for deaerator / 0.5 5 facilities / chemical / steel / power generating / 2
0 5 Q l/s 50 500 3 10 Q l/s 100
Condensate / Drain in energy industries, 3 20 Q m3/h 200 1800
pulp / food industries, and others 15 50 100 Q m3/h 300 900
Processes in petrochemical / chemical industries,
3
Water feed / Drainage for general industries Capacity up to 1,560 m /h / 6,860 USgpm Capacity 3
up to 810 m /h / 3,560 USgpm
Total Head up to 220 m / 720 ft Total Head up to 100 m / 320 ft
Temperature up to 350C / 660F Temperature -100 to 350C / -210 to 660F
Pressure up to 2.45 MPa / 24.5 bar / 355 psi Size 32 to 200 mm
Size 32 to 250 mm

17 18
Double-Suction Pumps Multi-Stage Pumps
Double-Suction

Multi-Stage
CDM, CDMV(Vertical) 200
500
300
USgpm 5000 10000 30000 50000 100000 150000

1000
MHB 4200
100 USgpm 500 1000 8000
13000

Axially split double-suction pump Radially split barrel casing pump 7000
2000
H H
m ft
100
The worlds most advanced high efficiency pump achieved 300 The barrel casing is fully welded to the pipe work 1000 3000
H
by design to match the double suction and H
ft
and supported at its centerline on a fabricated
m
three-dimensional impeller with the latest hydraulics. steel base plate. The inner cartridge, which 500
100
Simple disassembly of upper half casing without disturbing 30 contains all pump components except the barrel 1500

pipe work enables ease of maintenance and inspection. and main stud bolts, is removable from the barrel
5 CDM as a complete unit for ease of maintenance. 700
200
Applications 50 300 Q l/s 1000 3000 10000
5 20 Q l/s 100 700
Water intake / Distribution / Boosting / Circulation / 500 2000 Q m3/h 10000 30000 Applications 20 50 Q m3/h 200 2000

Drainage / Fire-fighting in energy industries, Cooling water Boiler feed in thermal power plants, 3
circulation for district heating and cooling, Water intake / 180 to 33,000 m3/h / High pressure feed water in various industries, Capacity up to 2,000 m /h / 8,800 USgpm
Capacity 790 to 145,200 USgpm Total Head up to 4,200 m / 13,800 ft
Distribution / Boosting for general industries, Water intake / and others
Total Head 3 to 300 m / 10 to 980 ft Temperature up to 230C / 440F
Distribution / Water supply / Boosting in seawater pressure up to 42 MPa / 420 bar / 6,090 psi
Temperature up to 80C / 175F
desalination / water works / sewage, Irrigation for Speed up to 7,000min-1
Size 200 to 1,400 mm CDMV
agriculture, Drainage, Pipe-line boosting, and others Size 80 to 200 mm

CDKY, CDKS 500


500 1000 USgpm 5000 10000 20000
MHG 4200
100 USgpm 500 1000 4000
13000

300 1000
Horizontal radially split double-suction pump Horizontal multistage ring section pump
2000 7000
CDKS H H
400
m ft
The rotating parts can be taken out by removing 100 Radially split ring-section high-pressure
H 1000
the side cover in axial direction. Suitable for H ft
multistage diffuser type pump. No warming 3000
CDKY through required enabling rapid start-up.
handling high temperature and pressure liquids m
500
in chemical plants and power plants. CDKY 30
100
1500
mainly used as booster pump for boiler feed Applications
pump and hot water circulation pump. Boiler feed in power plants,
40
10
20 50 100 Q l/s 500 1000 2000
High pressure feed water in various industries, 200
5 20 Q l/s 100
700
400
Applications 100 200 500 Q m3/h 2000 5000
CDKY and others 20 50 Q m3/h 200 1000
Processes in power / chemical / pulp industries,
and others CDKY CDKS Capacity up to 1,400 m/h / 6,100 USgpm
Capacity up to 3,480 m3/h / 15,300 USgpm up to 3,000 m3/h / 13,200 USgpm Total Head up to 4,200 m / 13,800 ft
Total Head up to 160 m / 520 ft up to 300 m / 960 ft Temperature up to 200C / 390F
Temperature up to 210C / 410F up to 350C / 660F Pressure up to 42 MPa / 420 bar / 6,090 psi
Size 125 to 400 mm 200 to 500 mm Speed up to 7,000 min-1
Size 40 to 250 mm

CDKTV 120
5000 15000 30000 USgpm 80000 MHD 2000
20 100 USgpm 1000 2000

Vertical double-suction pump with canister 100


350 Horizontal multistage ring section pump 5000

300 1000 H
ft
The hydraulic design of the double-suction 80 H Radially split ring-section high-pressure H
2000
impeller offering low-shut off head, low NPSH ft multistage diffuser type pump achieving high m
H efficiency and low NPSH. No warming through
and high speed. Mainly applicable for brine m
400
200
recirculation in seawater desalination plants and required enabling rapid start-up.
1000
condensate in geothermal power plants when
50
severe suction condition with large capacity and 150
Applications 200

high head required. 40 Boiler feed in power plants, 100


500
350 850 1500 Q l/s 4000
Q m3/h 5000
High pressure feed water in RO desalination / 1 3 10 Q l/s 100 140
1000 2000 10000 20000 10 3
Q m /h 100 500
Applications various industries, and others
Brine recirculation / Brine blow down Capacity up to 20,000 m3/h / 220,000 USgpm Capacity 3
up to 300 m /h / 1,320 USgpm
in seawater desalination plants, Total Head up to 100 m / 320 ft Total Head up to 1,200 m / 4,000 ft
Hot well / Large volume condensate Temperature up to 100C / 210F Temperature up to 180C / 350F
in geothermal power plants Size 500 to 1,500 mm Pressure up to 14 MPa / 140 bar / 2,030 psi
Speed up to 7,000 min-1
Size 80 to 200 mm
19 20
MSH, MSH-T(twin-suction) 2000 3000 5000 USgpm 10000 15000
MMO, 1000
30 100 USgpm 500 1000

Horizontal axially split multistage volute pump 800


2500
MMOV(Vertical) 500
2000

500
The axially split design offers ease of H MSH-T Multistage ring section pump 100
H MSH-T ft H
maintenance of rotating equipment without m
H
ft
MSH m
removing the lower casing. MSH-T covering high Compact and light-weight. Pump feet integrally cast 100
head range is twin-suction structure to satisfy
high suction capability. 1500 onto bearing housings, allowing free orientation of
10
400 both suction and discharge nozzles. No cooling of 20
Applications shaft seals required up to 140C liquid.
3
High pressure seawater feed 100 200 Q l/s 300 500 800 1000 MSH 1 2 Q l/s 10 30 70
in RO desalination plants, 500 Q m3/h 1000 2000 3000 3500 Applications 10 Q m3/h 100 250
Distribution for water works, Boiler feed / Condensate / Distribution for general
Water pumping for agriculture, and others industries, Water intake / Distribution / Water supply / Capacity up to 130 m3/h / 570 USgpm
MSH MSH-T
Capacity up to 1,500 m3/h / 6,600 USgpm up to 3,000 m3/h / 13,200 USgpm Boosting for water works, Feed water / Drainage in Total Head up to 400 m / 1,320 ft
Total Head up to 750 m / 2,460 ft up to 800 m / 2,600 ft building facilities, Cooling water / Hot and Cold water Temperature up to 140C / 280F
Size 100 to 300 mm 200 to 350 mm circulation, Water pumping / Drainage for agriculture, Size 32 to 65 mm
and others
Multi-Stage

MHH 1000 2000 USgpm 3000 4000


MMTV 500
20 100 USgpm 1000 10000
Ring casing type Bowl casing type

Multi-Stage / Specialized
800 1000
Axially split multistage pump 2500
Vertical multistage pump with canister
H
100
ft
H H
The axially split design offers ease of H ft The high pressure vertical canister pump offers m
100
30
maintenance of rotating equipment without m significant advantage in those cases where
removing the lower casing. Applicable for high to limited suction head is available. Applicable
low head duty by changing the number of 1500 especially for condensers in power plants, 10

stages. 300
desalination plants and other pipeline pumping
applications. 3 10
Applications 0 50 100 200 300
1 10 Q l/s 100 850
Q l/s 10 100 Q m3/h 1000 3000
High pressure seawater feed 200 400 Q m3/h 800 1000
Applications
in RO desalination plants, Hot water / Condensate / High and low pressure
Distribution for water works, and others Capacity up to 800 m3/h / 3,520 USgpm drain in thermal power plants up to 2,900 m3/h / 12,760 USgpm
Capacity
Total Head up to 800 m / 2,600 ft up to 490 m / 1,560 ft
Total Head
Size 150 to 300 mm up to 200C / 390F
Temperature
Pressure up to 3.9 MPa / 39 bar / 565 psi
Size 40 to 400 mm

MHA 1000 2000 USgpm 3000 4000

Specialized Pumps
Horizontal end-suction multistage ring 800
2500
section pump
H
The diffuser guides flow from impeller discharge H ft
m
to next impeller suction eye. The axial force is
compensated by a hydraulic balancing device.
1500
The integrated design accumulated by high
pressure and high speed pumps results in 300
excellent cost performance and high efficiency.
0 50 100 Q l/s 200 300
Applications 200 400 Q m3/h 800 1000
High pressure seawater feed
Capacity up to 800 m3/h / 3,520 USgpm
in RO desalination plants
Total Head up to 800 m / 2,600 ft
Size 125 to 200 mm

100 USgpm 1000 10000 30000

MMK, MML 500


30 300 USgpm 3000 8000

1500
HLV, HLAV 200

500

Horizontal multistage ring section pump Glandless(sealless) pump motor unit H


100
300 1000
(Boiler circulation pump) ft
H
MML m
Axial thrust of MMK is balanced by the impeller H H MMK 200
m ft
balance holes, and by way of MML the balance Pump and motor are integrated in a pressure- 50
500
disc, so that MMK and MML can operate with high 150 tight casing. The glandless design (no shaft seal)
reliability at high speed. 100 makes this pump best suited for pumping of high 100
MMK temperature and high pressure liquids without
Applications 100 any leakage. Volute, annular or spherical casing 20
1 10 Q l/s 100 1000
Boiler feed in power plants, 0
2 20 200 600
designs optionally available. Q m3/h 1000
Q l/s 10 100 6000
High pressure feed water in various industries, 10 Q m /h3
100 1000 2000 MML
Condensate in seawater desalination, Applications Capacity up to 6,000 m3/h / 26,420 USgpm
Distribution / Boosting for water works, MMK MML Boiler circulation in super / sub critical power Total Head up to 180 m / 590 ft
Irrigation for agriculture, and others Capacity up to 1,800 m3/h / 7,930 USgpm up to 1,800 m3/h / 7,930 USgpm plants Temperature up to 420C / 790F
Total Head up to 150 m / 490 ft up to 500 m / 1,640 ft Pressure up to 32 MPa / 320 bar / 4,640 psi
Temperature up to 230C / 440F up to 230C / 440F Motor Rating up to 1,000 kW
Size 40 to 350 mm 40 to 350 mm Voltage 400V to 11 kV
Size 40 to 400 mm
21 22
Mixed-Flow Pumps SPSX 20
2000 USgpm 4000 6000
60

Mixed-flow volute pump 15 50

Mainly used for water pumping and drainage for H 40


m H
agriculture. Simple back pull-out structure ft
10
allowing ease of overhaul. 30

Applications
20
Water pumping / Drainage for agriculture, 5
Drainage for civil engineering work, 100 200 Q l/s 300 400
Flood control, and others 400 700 Q m3/h 1000 1400

360 to 1,380 m3/h /


Capacity 1,580 to 6,070 USgpm
Total Head 5 to 17 m / 16 to 54 ft
Size 250 to 350 mm

SP 20
3000 USgpm 30000 200000

50
Axial-Flow Pumps
Horizontal mixed-flow pump 10
30

H
ft
H
Offering the highest efficiency in low head and m 20
large capacity range. The axially split design
offering ease of maintenance of rotating 10
equipment without removing the lower casing. 2

Applications
Water pumping / Drainage for agriculture, 150 1500 Q l/s 15000
Sewage transfer, 600 5000 Q m3/h 50000

Rain water drainage,


600 to 36,000 m3/h /
Storm surge drainage, and others Capacity 2,600 to 158,400 USgpm
Total Head 2 to 9 m / 6 to 29 ft
Temperature up to 40C / 100F
Size 400 to 2,000 mm

SPV 3000 USgpm 30000 300000


IS 2000 20000 USgpm 200000 1000000
Mixed-Flow

100 300 6

Vertical mixed-flow pump 50


200 Axial-flow propeller pump 15
4
100
H
Diffuser type, single or multistage design, m
Diffuser type, axial flow propeller suspended H 10
50 within wet pit. Offering various hydraulic models m
mixed-flow impeller suspended within wet pit.
Offering various hydraulic models, materials, 10
H suitable for large capacity with low pump head of H
2 ft
and installation arrangement (above or below ft water. Axially split design offering easy
floor discharge) to suit the plant specific design. 15
maintenance without removing the lower casing. 5

Applications 2 Applications 1
150 Q l/s 1500 15000 Water pumping / Drainage for agriculture, 110 500 Q l/s 5000 20000 66000
Rain water drainage / Water intake for water

Axial-Flow
600 Q m3/h 5000 50000 Q m3/h 20000 50000
works / sewage, Circulation / Cooling water / Sewage transfer, 400 2000 200000

Condensate in power plants, Seawater intake / 600 to 80,000 m3/h / Rain water drainage, 660 to 36,000 m3/h /
Capacity 2,600 to 360,000 USgpm Storm surge drainage, and others Capacity
Brine recirculation in seawater desalination 2,900 to 158,400 USgpm
plants, Water intake / Cooling water in petro- Total Head up to 100 m / 330 ft Total Head 1.5 to 5 m / 5 to 16 ft
chemical industries, Cooling water / Water Temperature -10 to 80C / -50 to 175F Size 400 to 2,000 mm
Size 300 to 2,800 mm
intake / Dock drainage for general industries

SPSY 5000
60
USgpm 20000 50000 100000
ISV 6
2000 20000 USgpm 200000 1000000

160
Mixed-flow volute pump 40
Vertical axial-flow propeller pump 15
H 4
H ft
m H
Suitable for fresh water and waste water 80 Diffuser type, axial flow propeller suspended m
10

pumping. Both open and closed type impeller 20 within wet pit. Especially used for large capacity
H
available. with low head of water. The various hydraulic 2 ft
40
models applied to the change of the capacity and
5
Applications 10 head.
Distribution / Drainage for water works / sewage,
Water pumping for agriculture, 6 20 Applications 1
300 500 1000 2000 Q l/s 5000 10000 110 500 Q l/s 5000 20000 66000
Cooling water in power plants, Water pumping / Drainage for agriculture, 400 2000 Q m3/h 20000 50000 200000
1500 3000 Q m3/h 10000 30000
Seawater recirculation in seawater desalination River water drainage,
plants, and others Capacity up to 20,000 m3/h / 88,000 USgpm Cooling water in power plants 600 to 186,000 m3/h /
Capacity
Total Head up to 50 m / 160 ft 2,640 to 818,400 USgpm
Size 350 to 1,200 mm Total Head 1.5 to 5 m / 5 to 16 ft
Size 400 to 4,600 mm

23 24
Submersible Pumps S/M 250
500 1000 2000 USgpm 4000 5000
800

Dry-type submersible motor pump 200


600

Small light-weight and easy to handle. Best suited 100


300
for discharging waste water at construction sites H
and draining water in buildings and factories. The m H
motor is equipped with an auto-cut device, 50
ft

submersion detection device and protection 100


device. The impeller is made of wear resistant 10
materials. 10
0
0 50 100 Q l/s 200 330

Applications
3
Q m /h 600
0 150 300 900 1200

Waste water / Sludge drainage Capacity up to 1,000 m3/h / 4,400 USgpm


for civil engineering works, Total Head up to 230 m
Drainage in factories, and others Size 40 to 350 mm

SMI (Axial-Flow), 2000


10
10000 USgpm 100000 700000
30
T/B, T/C, T/N 60
50 USgpm 2000 5000 10000 20000 40000

150

SMS (Mixed-Flow) 6
SMS
20
Submersible motor pump 30

H
Tubular pump H
m ft Wide ranges of impellers suited for all types of
SMI 10
3 10
sewage and effluent, especially untreated sewage T/B
30

containing fibers, solid admixtures, sewage sludge, H


Horizontal tubular pump-units combining an SMI
circulating sludge. Removable device for ease of m H
axial-flow or mixed-flow pump and a dry-type electric ft
maintenance and inspection also available.
motor in a single tube. Little noise and compact 2
owing to the small water flow loss and the combined 4 5
1 Applications
motor. Either connected directly to an electric motor 100 1000 Q l/s 10000 60000 3 100 Q l/s 500 1000 3000
Waste water / material drainage for sewage,
or used with a reduction gear for slower rotation. 400 4000 Q m3/h 40000 200000 10 400 1000 Q m3/h 2000 4000 10000
Waste water / material drainage for construction T/B
Capacity up to 210,000 m3/h / 924,000 USgpm facilities,
Applications T/B (Bladeless) T/C (Cutter) T/N (Non-clog)
Total Head 2 to 8 m / 6.5 to 26 ft Rain water drainage, and others
Water intake / Distribution / Drainage for water Capacity
up to 4,800 m3/h / up to 72 m3/h / up to 78 m3/h /
works, Water pumping / Drainage for agriculture, Size 400 to 5,000 mm 21,100 USgpm 310 USgpm 340 USgpm
Industrial water / cooling water / drainage, Drainage Total Head up to 40m /130ft up to 22 m / 72 ft up to 26 m / 85 ft
for civil engineering work, and others Size 50 to 800m 50 to 100 mm 32 to 100 mm

SMIV(Axial-flow), 3000
15
5000 USgpm 10000 20000

40
F/TB 50 100 USgpm 500 1000 2000

SMSV(Mixed-flow) 10

SMSV
Submersible motor pump for deep well 200
700

20
Dry-type submersible pump 5 Vertical or horizontal submersible motor pumps 100 350
H
ft with radial or mixed flow impellers, multi-stage.
H
m 10 Water sealed three-phase induction motor is H
Large capacity submersible propeller pumps with low m H
SMIV highly reliable electrically and mechanically as
head capabilities. Offering high efficiency and superior ft
2 submersible motor, and enables less trouble and
performance with compact design and easy operation. 30 100
5 safe operation.
Designed to meet the requirements for efficient handling
1
of large capacity of water. In particular, for installation, 200 Q l/s 500 1000 1400
Applications
maintenance and inspection in pits, Auto In-Pipe Column 800 1000 Q m3/h 2000 5000 1 5 10 Q l/s 50 130
Water intake / Distribution / Water supply Q m3/h
Installation type adopted because of the high reliability SMIV SMSV
10 20 100 200 400
for water works,
and rapid discharge connections.
Water feed / Distribution for general industries, Capacity 3 to 400 m3/h / 13 to 1,760 USgpm
SMIV SMSV Water pumping for agriculture Total Head up to 200 m / 655 ft
Applications Capacity up to 4,500 m3/h / 19,800 USgpm up to 4,200 m3/h / 18,500 USgpm Size 25 to 200 mm
Water pumping for agriculture, River drainage, Rain water Total Head up to 6 m / 19 ft up to 14 m / 46 ft
drainage, Water intake / Drainage for sewage, and others Size 400 to 700 mm 400 to 700 mm

SMV, SMRV 80
1000 USgpm 10000 40000

200
F/VC, F/VD, F/UW, 10
100
100 USgpm 1000 4000
300
50
Large-size submersible motor pump
F/SP
Submersible

Submersible
200
100
50

SMV is vertical tubular casing pump with 50 Submersible motor pump for shallow well 100
H H
submersible motor. Water-filled or oil-filled type 10
30
m ft
motor is provided. H
H Water sealed three-phase induction motor is 50
ft
SMRV uses an oil-filled type submersible motor m adopted for submersible motor. Suction entry of
10 10
whose suction entry is located between motor and F/VC and F/UW is located at the bottom and that
2
pump. of F/VD and F/SP is between pump and motor. 20

1 4
Applications 0.8 50 Q l/s 500 2000 3000
Applications 0.6 2 Q l/s 20 200 300
100 200 Q m3/h 2000 10000 10 50 Q m3/h 500 1000 F/VC
Water intake / Distribution / Drainage for water works, Water intake / Distribution / Water supply
Water pumping / Drainage for agriculture, Capacity 3
up to 9,000 m /h / 39,600 USgpm for water works, F/VC F/VD F/UW F/SP
Industrial water / cooling water / drainage, Total Head up to 70 m / 230 ft Water feed / Distribution for general industries, up to 66 m3/h / up to 300 m3/h / up to 420 m3/h / up to 660 m3/h /
Drainage for civil engineering work, and others Size 150 to 1,000 mm Water pumping for agriculture Capacity 290 USgpm 1,320 USgpm 1,850 USgpm 2,900 USgpm
SMV Total Head up to 90 m / 295 ft up to 70 m / 229 ft up to 46 m / 150 ft up to 46 m / 150 ft
Size 40 to 100 mm 65 to 250 mm 125 to 250 mm 125 to 300 mm

25 26
Miscellaneous Pumps TE/O, 50
10 50 USgpm 200 1000 2000
150

TE/CO (Stainless steel) 30 100

H
Self priming pump H
ft
m

No need for priming. Offering outstanding self 40


10
priming performance and durability.
Direct-connected motor is standard.

Applications 4
15
0.5 2 10 Q l/s 50 200
For industrial facilities, construction facilities, 2 10 3
Q m /h 50 200 500
agriculture, waste water treatment, and others
Capacity up to 780m/h / 3,434USgpm
TE/O TE/CO
3
Capacity
Total Head up to 70m
300 m/ 229ft
/h / 1,320 USgpm up to 180 m3/h / 790 USgpm
Total Head
Size up to 250mm
50 40 m / 130 ft up to 50 m / 160 ft
Temperature 0 to 40C / 30 to100F 0 to 40C / 30 to100F
Size 25 to 200 mm 25 to 125 mm

K/LP, 100
5 20 USgpm 100 300
300
O/PS 80
100 USgpm 500 2000 5000
250

K/SLP2 (Stainless steel) 30 100


Pulp pump H
ft

Line pump H Suitable for pumping slurry and pulp stocks up


30 100

H ft
m to 5% consistency. The Impeller is Mixed flow H
m 50
Pump and 2-pole motor close coupled with 20 type allowing the pump to be used for a wide
common shaft. Line construction of suction entry
5 range of applications. 10
30
and discharge fits in any position into a pipeline.
Applications
5
Applications 1
Pulp liquid transfer for paper / pulp industries, 4
1 Q l/s 5 25 0 Q l/s 10 50 400
Water and hot water circulation in building facilities, Q m3/h
Solid transfer / drainage for general industries, Q m3/h
1 3 10 20 90 20 50 200 1000
Processes for various industries, Fruit or cereal and water mixture transfer for
General water feed, Capacity up to 84 m3/h / 370 USgpm food industries, and others Capacity up to 780 m3/h / 3,430 USgpm
Boosting for water works, and others Total Head up to 60 m / 20 ft Total Head up to 70 m / 230 ft
Temperature up to 100C / 210F Size 50 to 250 mm
Size 25 to 100 mm

N/WR 3 10 20 USgpm 100 200 500


SNK 350 1000 USgpm 5000 20000 50000

300 9 30
Wesco pump Screw Pump
H 800 H
m m H
Specially-shaped impeller revolves at high speed H Suitable for pumping liquids containing small ft

in casing, makes the flow and absorbs up. 200 ft stones, other suspended solids or rags, pieces of 6

Extremely small impeller clearance due to the use 500 wood or ropes, digested or activated sludge etc. 15

of a special method of fixing and special materials The simple, rugged construction and the open
100
to assure high stability. Best suited for screw trough facilitate maintenance and 3

applications with small capacity and high head. inspection.


100
2 7
0 20 200 2000 5100
Applications
0 1 2 Q l/s 8 16 32 Applications 75 500 1000 5000
Q l/s
Q m3/h 10000
Q m3/h
Water feed / pumping for general industries,
2 5 10 50 100 Water pumping for treatment plants,
Chemical liquid transfer, Capacity up to 72 m3/h / 310 USgpm Water pumping / Drainage for agriculture, Capacity up to 18,000 m3/h / 79,250 USgpm
Various fuel oil transfer, Total Head up to 300 m / 980 ft Return sludge for sewage treatment plants, Total Head up to 10 m / 32 ft
High pressure boiler feed, Temperature up to 90C / 190F Waste water transfer, and others Size 400 to 3,500 mm
High pressure washing, and others Size 15 to 80 mm

NV Air Capacity up to 72 m3/min


Negative Pressure up to 88 kPa
S/T 10
100
100 USgpm 1000 4000
300

Size 20 to 100 mm
Vacuum pump Vertical Volute Pump 200
50

100
The rotating, water-sealed pump sucks and Easy-installation close-coupled construction. Size H H
exhausts gas using the centrifugal force of the 40 to 100mm back pull-out structure facilitates m ft
liquid. Continuous gas exhaustion is made ease of maintenance. 50

without vibration and in complete safety even 10


when water enters in the pump interior during Applications
operation. Boosting / Water feed / Water pumping for 20

general industries, and others 4


0.6 2 Q l/s 20 200 300
Applications 10 Q m3/h 50 100 500 1000
Miscellaneous

Miscellaneous
Pump water priming,
3
Gas exhaustion / Vacuum generation / Capacity up to 600 m /h / 2,640 USgpm
Pressure-feeding for chemical industries Total Head up to 75 m / 240 ft
Temperature 0 to 80C / 32 to 176F
Size 40 to 150 mm

27 28
Torishimas Torishimas
Mechanical Seals Service Solutions
Mechanical seals - the shaft seals used in rotating machinery such as pumps, hydraulic turbines, agitators and As a premier engineered equipment supplier, Torishima is
centrifuges - play an important role in maintaining the safety and economic efficiency of machinery. As a comprehensive committed to provide the highest quality aftermarket service.
manufacturer of pumps, Torishima has never lost sight of the importance of mechanical seals. We are the fastest in the Our innovative solutions can enhance performance and
country at moving products from the research and development phase to manufacturing and commercialization. increase the life span of pumps, other equipment and plants.
This allows operators to maximize efficiency, reduce
Today, we provide a wide range of mechanical seals for applications requiring high levels of safety and quality, such as
maintenance costs and conserve energy.
mechanical seals for sealing high-temperature and high-pressure fluids in power plant pumps (including boiler feed
pumps and boiler circulating pumps). We also manufacture mechanical seals for pumps used in sewage plants,
chemical plants, and desalination plants handling slurry-rich liquid, special highly corrosive liquids, and seawater. Installation & Field Test
Moreover, we have utilized our years of experience in pump manufacturing to provide eco-friendly non-flushing seals,
Torishima provides field engineering service wherever needed to supervise pump installation work and equipment
easy-maintenance cartridge seals, and a variety of other optimal mechanical seals for a diverse range of applications.
commissioning, ensuring the pumping equipment can meet customer expectations.

Mechanical Seal Applications


Field and Application Power Seawater Desalination Water Works Rivers, Agriculture Chemicals & General Industry, etc.
Maintenance, Overhaul, Operator Training
Generation & Sewerage & Irrigation Petrochemicals

Process pumps
Boiler feed pumps

Boiler circulating pumps

Condensate pumps

Cooling water pumps

High-pressure pumps

Water filtration pumps

Back wash pumps

Brine recirculation pumps

Brine blowdown pumps

Seawater intake pumps

Product water pumps

Water transmission & distribution pumps

Sewage treatment pumps

Stormwater drainage pumps

River drainage pumps

Agricultural pumps

Agricultural drainage pumps

Irrigation pumps

Process pumps

Feed water pumps

Cooling water pumps

Feed water pumps

Cooling water pumps

Electro-deposition paint pumps

Submersible pumps

Sand pumps

Hydraulic turbines
Torishima offers targeted advice after performing a full
maintenance inspection of the entire pump installation,
performing necessary maintenance, and diagnosing
whether the facility is being operated under the optimal
Model of conditions. When pumping equipment breaks down,
Mechanical Seal our experienced engineers determine the basic cause
LU1000 Series through a full analysis and replace broken parts to
Rubber
bellows seals ensure rapid restoration. In addition, we provide
LD1000 Series
(Double seal)
Inspecting of pumping plants
hands-on guidance and training to plant operators.
Rotating
HU2000 Series
(Unbalanced type)
single-spring
seals HB2000 Series *REDU is a registration of
(Balanced type)

MU2000 Series
Solution Provider trademark of TORISHIMA
(Unbalanced type)
Rotating To improve your plant's productivity, Torishima offers
multi-spring
seals
MB2000 Series
(Balanced type) Whats
longer reliable and high-efficiency pumps. In addition to
MT2700 REDU?
(Balanced type) servicing our own units, we restore, repair, improve and
Stationary MB2500
multi-spring
seals (Balanced type) upgrade even for pumps of other manufacturers. Using
Torishima has the ability to combine field service
MB2704CN the most advanced technologies, we offer products that
(Inside rotating type) engineering and product design technology.
MB2704CZ provide you with the highest efficiency and highest This results in our engineers being able to provide
(Inside rotating type,
with pumping ring)

possible performance. advice on improved design and the upgrade of in-site
MB8500CN
Cartridge
seals (Stationary inside type)
pumping equipment and other rotating equipment.
MB8500CZ
(Stationary inside type,
with pumping ring)
Energy Operating cost and CO2 emissions are reduced by
Saving upgrading to a more reliable and higher-efficiency pump.
MB2400CN
(Outside rotating type)
MB2901
(Stationary balanced type,
non-flushing)
Reduction of
energy consumption
MU2922
Split seals (Stationary balanced type,
dry running application)
and CO2 emissions Impeller Impeller
Before After
MT9200
(Stationary balanced type,
dry running application)
upgrading upgrading

MT4100 Upgrade
Stationary
seals (Balanced type)
For hydraulic
Special-purpose turbines
Existing High- Casing Casing
seals For submersible
sand pumps Existing pump High-efficiency pump pump efficiency
pump

29 30
PUMP PRODUCTS GUIDE

TORISHIMA PUMPMFG. CO., LTD

You might also like