You are on page 1of 25

1|Page

RTN 950
1. Outdoor:

There are two main types:

RTN600 ODU
RTN XMC ODU

RTN 600 ODU types:

High Power
Standard Power
Low Power

Comparison between ODU:

Low power (LP) Standard Power (SP) High Power (HP)


Modulation Supported QPSK-16QAM QPSK256 QAM QPSK256 QAM
Channel Spacing 3.528 MHz 3.528 MHz 756 MHz
Min Tx power / Max 0 /-20 dBm -6 /-20-25 dBm 1 /-20-25 dBm
Rx Power

How read RAU Label at site:

Show ODU type


(SP or LP or HP)

Show frequency range support by this RAU

MODEL:

1: refer to RAU Band 2: refer to equipment type PDH (P) or SDH (S)

3: refer to T/R (duplex distance) 4: refer to Sub band 5: refer to high power (P) & low power (N)

6: refer to output power level (standard or high)

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
2|Page

Table show example from Sub band and duplex distance at ODU:

ODU:

As show in figure, according to ODU direction at installation determine link Polarization (H or V), where
is no horn separated as Ericsson ODU

RTN XMC ODU

RTN 600 ODU

RTN XMC types:

XMC-1 XMC-2

Modulation Supported QPSK-16QAM QPSK256 QAM


Channel Spacing 3.528 MHz 3.556MHz

Min Tx power / Max Rx Power According to frequency According to frequency


ODU types Low capacity for PDH High power
Frequency band 723 GHz 742 GHz

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
3|Page

Label:

Show RAU sub Show frequency range Show frequency band and 2
band Hi or low supported indicate XMC-2 & 1 for
XMC-1
Hybrid Coupler (Power Splitter):

There are two types:

Balanced: losses between standard and Main equal (3dBm)


Un Balanced: losses at stand by 6 dBm

Label:

Model:

1: indicate hybrid Coupler 2: refer to frequency band 3: refer to Balanced (B) or UN Balanced (U)

4: refer to losses at standby

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
4|Page

IF cable type:

Type Applicable Distance Connector IF Jumper


(Distance Between an Required
IDU and an ODU)
ODU Side IDU Side

5D < 120 m Type N, male connector Type TNC, male connector No


cable

RG-8U 120 m to 180 m Type N, male connector Type N, male connector Yes
cable

1/2- 180 m to 300 m Type N, male connector Type N, male connector Yes
inch
cable

Note: A 5D cable connects the IF interface of an ODU to the IF interface of an IDU. An RG-8U cable or 1/2-inch
cable connects the IF interface of an ODU to the IF jumper of an IDU

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
5|Page

IF Specification of ODU:

Item Specification
Center frequency of the input IF 350 MHz
IF Signal Center frequency of the RX IF 140 MHz
Return loss of the IF interface < -15 dB
Modulation mode ASK
ODU O&M Signal Uplink signal 5.5 MHz
Downlink signal 10 MHz

Indoor:

Minimum requirements to install RTN:

1. Chassis
2. CST or CSH (main processing card)
3. IFU2 or any IF board to connect with ODU
4. FAN
5. PIU (Power interface Unit)

Chassis:

Air flow:

Heights: 2U

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
6|Page

All Board installed in chassis is half slot:

Controlling Board:

CST (Control switching and timing board) CSH (Control Switching and Hybrid board)
Valid slots 7/8 main 7 & stand by 8 7/8 main 7
Service Provide 32x32 cross connection VC4 Provide 32x32 cross connection VC4
Supported Support VC12 (E1) & VC4 Support VC12 (E1) & VC4 & 10G Packet switching
DCN Support out band DCN Support out band and in band DCN
NMS/COM port Port RJ45 Node Management (NM) Port RJ45 Node Management (NM)
EXT To manage cascaded nodes To manage cascaded nodes

Caution: never connect EXT port and NMS port with one cable as show in fig, where two ports connected
internal on same hub

CST:

CSH:

Each card has compact flash (CF) and Dip switch to take back up from main memory like as RMM at
NPU (Ericsson vendor)

1: refer to dip switch

2: refer CF card

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
7|Page

There are two buttons at card interface:

Button Name Description


CF RCV CF configuration restoration button After this button is pressed and held for eight seconds, the board
automatically restores the NE database from the CF card.
RST Warm reset button After this button is pressed, a warm reset is performed on the
board.

IF (Intermediate frequency) boards:

Main function convert baseband signal to IF (intermediate frequency)

IF1 IFU2 IFX2 ISU2 ISX2


Modulation QPSK128 QPSK256 QPSK256 QPSK256 QPSK256
Supported QAM QAM QAM QAM QAM
Channel spacing 728 MHZ 756 MHZ 756 MHZ 3.556 MHZ
E1 4E1STM 1 5 E175 E1 5 E175 E1 Support STM1& 2 Support STM1& 2
STM1 or 5 E1 STM1 or 5 E1
75 E1 75 E1
Packet rate NA 9420 Mb/S 9420 Mb/S 4456 M/bS 4456 M/bS
Min capacity 8 Mb/Sec 22 M 22 M 8 Mb/Sec 8 Mb/Sec
Max capacity 155 Mb/Sec 570 Mb/S 570 Mb/S 606 Mb/S 606 Mb/S
XPIC NA NA yes NA yes
Power -48 V -48 V -48 V -48 V -48 V
Slots (1+0) 3,5,4,6,12 3,5,4,6,12 3,5,4,6,12 3,5,4,6,12 3,5,4,6,12
priority
Slots (1+1) 3&5, 4&6, 1&2 3&5, 4&6, 1&2 3&5, 4&6, 1&2 3&5, 4&6, 1&2 3&5, 4&6, 1&2
Priority
DCN Out band only In band & Out In band & Out In band & Out In band & Out
band band band band
AM (Adaptive NA yes yes only only
Modulation) in Integrated IP in Integrated IP
radio mode radio mode
IF1 Board:

IFU2:

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
8|Page

IFX2:

ISU2:

ISX2:

Ethernet interface Board:

Use to drop Ethernet frame IEEE 802.3 at site

EM6T EM6TA EM6F EM6FA


FE (fast Ethernet) 4 Electrical 4 Electrical 4 Electrical 4 Electrical
GE (Giga Ethernet) 2 Electrical 2 Electrical 2 SFP (Optical) 2 SFP (Optical)
Valid Slots 4,6,2,1,3,5 4,6,2,1,3,5 4,6,2,1,3,5 4,6,2,1,3,5

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
9|Page

EFP8: support Ethernet over PDH support 8 ports 10/100 Mb/Sec

Valid slots: 4, 6, 1,2,3,5

SL1D & SL1DA: use to support one STM1 or 2 STM1 channelized & two ports SFP according to SFP
type it will support electrical or Optical

SP3S & SP3D: use to support E1 dropping at site

SP3S Support 16 E1 & SP3D Support 32 E1

SP3S:

SP3D:

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
10 | P a g e

E1 cable:

E1 Panel:

Use to drop E1
physically dir RBS

PIU (Power Interface Unit):

Power cable

Input Voltage: -38.4 V to -72.0 V

FAN:

Power Consumption: 4.1 W at room temp

Power Consumption: 29 W at high temp

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
11 | P a g e

U2000 Management Server

To get current alarm at RTN node press right click on RTN node as show in fig. and choose current
alarms:

The following fig appear

Alarm with green color it mean alarm clear if color


gray it mean alarm still found

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
12 | P a g e

Main alarms and solution:

Card Alarm Meaning


BD-Status & Hard Bad Card faulty & changed
It mean there is switching from main to
RPS-IND
CSH/CST stand by
indicating that the MS protection
APS-IND
switching occurs on SL1D card
IF cable Open
MW LOF Indicating that the radio frame is lost.
BD Status & Hard Bad Card faulty & changed
IF1/IFU2/ISU2 indicating that the power voltage is
Volt Loss
unavailable solve cold restart
indicates that the number of bit errors at
MAC_EXT_EXC
the MAC layer crosses the threshold
TU AIS Hard Bad Cross connection not complete at path
indicating that the signals on the receive
SL1D R-LOS
line side are lost
BD status & Hard Bad Card faulty & changed
indicating that the 2 Mbit/s analog
T-LOS
signal is lost at the specific port
There is problem at cross connection
TU-AIS
SP3D/SP3S (AIS)
UP E1 AIS E1 down from far end physical
Down E1 AIS E1 down from near end physical
BD status & Hard Bad Card faulty & changed
indicating that the radio receive power is
Radio RSL low
very low (like as RF input level)
ODU indicating that the radio transmit power
Radio TSL low
is very low
BD status & Hard Bad Card faulty & changed
indicating the loss of Ethernet port
Eth LOS
connection
EM6F/EM6T Solution force speed (100 Mb/S) not
Eth excessive BER
Auto negotiation
BD status & Hard Bad Card faulty & changed

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
13 | P a g e

There are two types for history alarms:

1. History alarms on NMS: this types get all alarms that synched between node at site &
U2000 server if node became down MNG & restored MNG again after specific time this
duration not synched by U2000 to get alarms at this duration use the second type
2. History alarms on NE: get all alarms on NE at site actual

to know link between two NE node and position for IF at each NE ( Site and facing) press on line
between two NE the following table appear as show in fig

This mark mean link 1+0

It mean link
from R2856
to R2853

3-IFU2 mean card IFU2 install


at slot 3 at site Source (R2856)

It mean card IFU2 install


at slot 4 at destination
(Facing)

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
14 | P a g e

To open NE (Network Element) press on NE double click:

This related to ODU and


each ODU has 2 before slot
number that connected with
it at indoor

It is indoor part and


each slot has zero
before number that
mean indoor

Slot 3 has IFU2 connect with ODU at (23) as show in NE fig

Press on it to open NE Press on it when add new Module


Explorer and configure at magazine
Modules

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
15 | P a g e

Open NE Explorer to start radio link Configuration:

Open Function treeconfigurationRadio Link Configuration as show in fig

4
13
5

7
8
9
10
11
12

1. To select IF board that you will configure it


2. To configure link type 1+0 or 1+1 according to SF6 file
3. Link ID (always default 1)
4. IF channel (channel spacing at E///) according to SF6 file
5. Modulation Mode (QPSK1024 QAM) according to IF board capability
6. Tx frequency
7. T/R Spacing it refer to duplex distance always let it zero where program write Rx automatic
according to duplex distance standard at this sub band
8. Tx power, it refer to transmitted power, RSL (Received signal power show under Tx power as
show in fig)
9. Unmute refer to transmitter power on
10. Refer to ODU Band at this example 23 GHZ
11. Refer to ODU Sub band (high or low)

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
16 | P a g e

12. Refer to ODU type (High Power) with RTN600 ODU as show before
13. Refer to AM (Adaptive Modulation) this solution use to save high priority CCT at bad
weathered& discarded low priority data (packet)

How to create E1 cross connection Local:

Open Function treeconfigurationSDH Service configurationpress create as show in fig

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
17 | P a g e

The following fig appears:

It mean E1 cross
Connection

E1 Source Connection

Press here to select E1 dropping


number as show in E1 dropping fig

Destination

It mean cross connection between E1


number 2 at SP3D & number 2 at IFU2

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
18 | P a g e

E1 dropping fig:

At SP3D card

Green slot mean available card can


make cross connection on it, Blue
Boarder mean it is selected
Select mark on needed
E1

The same steps with IFU2 Boarded you make cross connection at this indoor, at facing indoor received
E1 from the same E1 number that you selected here to drop it at destination card

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
19 | P a g e

To delete E1 locally (at Site):

Right click on CCT and choose Expand to Bidirectional (and start delete E1 number 2 as we created
before)

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
20 | P a g e

Native Ethernet Service types:

1. E-Line
2. E-LAN
3. QinQ

Steps to create E-LAN Service:

Open NE ExplorerConfigurationInterface ManagementEthernet Interface as show in fig

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
21 | P a g e

Configure LAN interface that will use in E-LAN Service:

1 3 4
5 2

Card EM6F use to support Native Ethernet LAN port and should be set this parameter at LAN Port

1. LAN Port Number


2. Port status :Enable
3. Encapsulation type: 802.1Q
4. Working Mode: Auto (auto negotiate Speed)
5. Name: description

Set Port Rule:

1. Tag aware (forward frame that has VLAN Tag and drop another tag)
2. Access (forward all frames like as no tag on frame)
3. Hybrid (forward frame with Tag or no tag)

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
22 | P a g e

Set parameter (Hybrid) as show in fig

Set Microwave port (at TN called WAN Port)

Open NE ExplorerConfigurationInterface ManagementMicrowave Interface

Set parameter 802.1 and write description at name part

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
23 | P a g e

Set tag type (Hybrid)

To create VLAN & assign Microwave port and EM6F port in the same VLAN (Switching)

Open NE ExplorerConfigurationEthernet Service ManagementE-LAN Service

Press here to start


switching service

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
24 | P a g e

1- Service ID: number range 1-4294967295


2- Service name: describe VLAN Name as TN
3- Press configure to start port selection 1
2
process

1- Ports that will started switching process 3


between them
2- VLAN ID, you can write range from VLAN
ID for ex 1-10 or write different VLAN ID
120,11,12 on the same port

2
1

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238
25 | P a g e

RTN Management parameter:

To set RTN IP

Open NE ExplorerCommunicationCommunication Parameters

7 for all RTN


installed at VF
eg network

Prepared by: Ahmed Hussien Bebars


ahmed.bebars.ericsson@gmail.com Mobile:+201024614238