1. Outdoor:
RTN600 ODU
RTN XMC ODU
High Power
Standard Power
Low Power
MODEL:
1: refer to RAU Band 2: refer to equipment type PDH (P) or SDH (S)
3: refer to T/R (duplex distance) 4: refer to Sub band 5: refer to high power (P) & low power (N)
Table show example from Sub band and duplex distance at ODU:
ODU:
As show in figure, according to ODU direction at installation determine link Polarization (H or V), where
is no horn separated as Ericsson ODU
XMC-1 XMC-2
Label:
Show RAU sub Show frequency range Show frequency band and 2
band Hi or low supported indicate XMC-2 & 1 for
XMC-1
Hybrid Coupler (Power Splitter):
Label:
Model:
1: indicate hybrid Coupler 2: refer to frequency band 3: refer to Balanced (B) or UN Balanced (U)
IF cable type:
RG-8U 120 m to 180 m Type N, male connector Type N, male connector Yes
cable
1/2- 180 m to 300 m Type N, male connector Type N, male connector Yes
inch
cable
Note: A 5D cable connects the IF interface of an ODU to the IF interface of an IDU. An RG-8U cable or 1/2-inch
cable connects the IF interface of an ODU to the IF jumper of an IDU
IF Specification of ODU:
Item Specification
Center frequency of the input IF 350 MHz
IF Signal Center frequency of the RX IF 140 MHz
Return loss of the IF interface < -15 dB
Modulation mode ASK
ODU O&M Signal Uplink signal 5.5 MHz
Downlink signal 10 MHz
Indoor:
1. Chassis
2. CST or CSH (main processing card)
3. IFU2 or any IF board to connect with ODU
4. FAN
5. PIU (Power interface Unit)
Chassis:
Air flow:
Heights: 2U
Controlling Board:
CST (Control switching and timing board) CSH (Control Switching and Hybrid board)
Valid slots 7/8 main 7 & stand by 8 7/8 main 7
Service Provide 32x32 cross connection VC4 Provide 32x32 cross connection VC4
Supported Support VC12 (E1) & VC4 Support VC12 (E1) & VC4 & 10G Packet switching
DCN Support out band DCN Support out band and in band DCN
NMS/COM port Port RJ45 Node Management (NM) Port RJ45 Node Management (NM)
EXT To manage cascaded nodes To manage cascaded nodes
Caution: never connect EXT port and NMS port with one cable as show in fig, where two ports connected
internal on same hub
CST:
CSH:
Each card has compact flash (CF) and Dip switch to take back up from main memory like as RMM at
NPU (Ericsson vendor)
2: refer CF card
IFU2:
IFX2:
ISU2:
ISX2:
SL1D & SL1DA: use to support one STM1 or 2 STM1 channelized & two ports SFP according to SFP
type it will support electrical or Optical
SP3S:
SP3D:
E1 cable:
E1 Panel:
Use to drop E1
physically dir RBS
Power cable
FAN:
To get current alarm at RTN node press right click on RTN node as show in fig. and choose current
alarms:
1. History alarms on NMS: this types get all alarms that synched between node at site &
U2000 server if node became down MNG & restored MNG again after specific time this
duration not synched by U2000 to get alarms at this duration use the second type
2. History alarms on NE: get all alarms on NE at site actual
to know link between two NE node and position for IF at each NE ( Site and facing) press on line
between two NE the following table appear as show in fig
It mean link
from R2856
to R2853
4
13
5
7
8
9
10
11
12
12. Refer to ODU type (High Power) with RTN600 ODU as show before
13. Refer to AM (Adaptive Modulation) this solution use to save high priority CCT at bad
weathered& discarded low priority data (packet)
It mean E1 cross
Connection
E1 Source Connection
Destination
E1 dropping fig:
At SP3D card
The same steps with IFU2 Boarded you make cross connection at this indoor, at facing indoor received
E1 from the same E1 number that you selected here to drop it at destination card
Right click on CCT and choose Expand to Bidirectional (and start delete E1 number 2 as we created
before)
1. E-Line
2. E-LAN
3. QinQ
1 3 4
5 2
Card EM6F use to support Native Ethernet LAN port and should be set this parameter at LAN Port
1. Tag aware (forward frame that has VLAN Tag and drop another tag)
2. Access (forward all frames like as no tag on frame)
3. Hybrid (forward frame with Tag or no tag)
To create VLAN & assign Microwave port and EM6F port in the same VLAN (Switching)
2
1
To set RTN IP