You are on page 1of 4

Sl.No.

Section UNIT Apr/17 May/17 Jun/17 Jul/17 Aug/17 Sep/17 Month Best 1/Oct 2/Oct 3/Oct
F Sectionwise Power Cons in CVRM-1 - - - - - - - - -
10 Running Hours Hrs. 501 531 560 500 607 386 Mar/17 665 - - -
11 TPH 114 116 113 109 106 111 Apr/16 122 - - -
12.00 Power per MT of material kWh/T 39.13 39.43 40.15 42.81 43.65 45.27 Dec/16 44.83 - - -
15.00 --Sectionwise power breakup - - - - - - - - -
15.01 CVRM BF Fan kWh/MT 7.64 7.83 8.07 8.13 8.02 8.38 Apr/16 6.92 - - -
15.02 Main Drive kWh/MT 23.71 22.95 23.12 24.57 25.76 26.73 May/17 22.95 - - -
15.03 Booster Fan kWh/MT 1.36 1.44 1.69 2.42 2.95 2.01 Apr/17 1.36 - - -
15.07 Aux kWh/MT 6.13 6.89 7.02 7.22 6.72 7.39 4.09 - - -
Total 39.13 39.43 40.15 42.81 43.65 45.27 37.00 - - -
Sl.No. Section 4/Oct 5/Oct 6/Oct 7/Oct 8/Oct Oct/17 Ftd
F Sectionwise Power Cons in CVRM-1 - - - - - ###
-
10 Running Hours - 8.1 - 4.0 23.5 35.6
###
11 TPH - 122.1 - 105.2 110.1 112.3
###
12.00 Power per MT of material - 40.7 - 51.4 40.9 44.8
###
15.00 --Sectionwise power breakup - - - - - ###
-
15.01 CVRM BF Fan - 7.0 - 9.3 8.1 7.9
###
15.02 Main Drive - 23.2 - 24.9 24.6 24.3
###
15.03 Booster Fan - 3.1 - 4.8 2.5 2.9
###
15.07 Aux - 7.5 - 12.4 5.8 9.7
###
Total - 40.7 - 51.4 40.9 44.8
###
A Sectionwise power Cons of Line-2 Monthly Best
Sl.No. Section UNIT Apr/17 May/17 Jun/17 Jul/17 Aug/17 Sep/17 Month

B 4.Sectionwise power of VRM


3 Running Hours Hrs. 434 430 422 330 443 458 Jul/16
4 TPH TPH 481 481 478 482 472 478 Jul/17
8 --Sectionwise power breakup
8.03 VRM Fan kWh/T of RM 5.32 5.31 5.32 5.36 5.49 5.52 Oct/16
8.04 VRM Drive kWh/T of RM 4.41 4.37 4.42 4.27 4.40 4.56 Sep/16
8.06 Aux kWh/T of RM 1.78 1.83 1.87 1.93 1.91 1.88
Total kWh/T of RM 11.51 11.52 11.61 11.56 11.80 11.96
- - - - - -
C Sectionwise power of Coal Mill - - - - - -
3 Coal mill prod.-Actual MT 14067 14433 14071 11980 15381 14459 Aug/17
5 Running Hours (A) 634 568 615 499 665 653 Aug/17
7 TPH -Actual TPH 22 25 23 24 23 22 Sep/16
22.3 Coal Mill Fan kWh/T 12.54 13.15 13.77 12.91 13.28 13.54 Aug/16
22.4 Booster Fan kWh/T 3.30 2.88 3.21 3.06 3.15 3.38 Sep/16
22.5 Caol Mill Drive kWh/T 28.23 23.28 23.81 22.82 23.72 23.42 May/16
22.8 Aux kWh/T 14.66 13.25 13.43 15.75 14.90 14.84
Total 58.73 52.56 54.21 54.54 55.04 55.19
- - - - - -
D Sectionwise power of Kiln - - - - - -
3.00 Running Hours Hrs. 712 714 699 536 732 707 Jan/17
4.00 TPH TPH 189 184 186 183 186 194 Dec/34
8.00 --Sectionwise power breakup - - - - - -
8.01 PH Fan kWh/T of Clr 11.77 11.53 11.87 12.01 11.68 11.84 Nov/16
8.02 BH Fan kWh/T of Clr 3.67 3.81 3.49 4.04 3.59 3.70 Apr/16
8.03 Main Drive kWh/T of Clr 1.70 1.72 1.69 1.65 1.68 1.72 Sep/16
8.04 Cooler kWh/T of Clr 4.98 5.02 5.24 5.06 5.12 5.10 Jan/17
8.05 Aux kWh/T of Clr 8.00 8.11 7.97 8.27 6.61 8.17
8.13 Total kWh/T of Clr 30.13 30.18 30.25 31.04 28.68 30.52
Mtd 3.5 100000
Monthly Best
Best Oct/17

515 105.9
482 478.0

5.19 5.2
4.21 4.1
1.74 1.9
11.13 11.2

15,381 4078.1
665 179.4
28 22.7
10.36 12.6
2.60 3.2
16.13 21.8
13.95 15.6
46.66 53.2

744 192.0
194 184.6

10.39 11.8
3.29 3.7
1.20 1.6
4.71 4.9
5.96 6.7
25.55 28.6