You are on page 1of 3

Discharge Suction

P (lb/in^2) 9316.8 2116.8


v (ft/s) 6.303733018 1 lbf = 32.174 lbm-ft/s^2
z (ft) 10 4
F (lbf/in^2 5.5 0.5 efficiency 0.6
F (lbm-ft/ 176.957 16.087 pvap 3.8
F (lbm/ft-s 25481.81 2316.528
density (l 54
volumetric 40 31.7333333333
volumetric 0.0891203642
HEAD (ft) 197.8175 45.15087
TDH (ft) 152.6666666667 Power (lb ft /s) 1224.514
Power (lbf/s) 38.05911
Schedule 40
Diameter ( 1.5
ID (in) 1.61
Area (in^2 2.035831
Area (ft^2 0.014138
Sch. 40 Sch. 80 Sch. 120
DIA. O.D. I.D. Wall O.D. I.D. Wall
3/4 1.05 0.824 0.113 1.05 0.742 0.154
1 1.315 1.049 0.133 1.315 0.957 0.179
1 1/2 1.9 1.61 0.145 1.9 1.5 0.2
2 2.375 2.067 0.154 2.375 1.939 0.218
3 3.5 3.068 0.216 3.5 2.9 0.3
4 4.5 4.026 0.237 4.5 3.826 0.337 4.5 3.624 0.438
5 5.563 5.047 0.258 5.563 4.813 0.375 5.563 4.653 0.5
6 6.625 6.065 0.28 6.625 5.761 0.432 6.625 5.501 0.562
8 8.625 7.981 0.322 8.625 7.625 0.5 8.625 7.189 0.718

40
80
120
Entrance
Inward-protecting Pipe Entrance
Sharp-edged Entrance
Slightly-rounded Entrance
Well-rounded Entrance

Materials of Construction
A. Copper, 0.0000015
B. Commerc 0.000046
C. Wrought 0.000046
D. Ductile 0.00012
E. Ductile 0.00024
F. Concrete 0.00012
G. Riveted 0.0018

You might also like