July 10, 2013 | Slide 2
PASS The ABB Hybrid Module
Overall Description
GIS
high
DTB
Circuit Breaker
LTB Current Transformer
Circuit Breaker
low
Encapsulation
ABB Group
July 10, 2013 | Slide 4
PASS Plug And Switch System
Components
1
2
1
3
2
4
3
6 1. Stud for HV connection
8 2. Bushing
3. Current transformer
4. SF6 Voltage transformer
7 5
inductive type
5. DS/ES Operating drive
mechanism
6. Circuit breaker
9 7. Combined
Disconnector/Earthing switch
8. BLK Spring-type circuit
breaker operating mechanism
9. Local control cubicle
ABB Group
July 10, 2013 | Slide 5
PASS Plug And Switch System
Circuit breaker
Self-blast or Auto-puffer
Arc-assisted pressure
generation leads to less need
of interrupting energy
Smaller operating
mechanism
Lower stresses on
mechanical components
ABB Group
July 10, 2013 | Slide 6
PASS Plug And Switch System
BLK spring drive
Extremely reliable
Low power consumption
Precise and stable
operating times
ABB Group
July 10, 2013 | Slide 7
PASS Plug And Switch System
Motor Drive
ABB Group
Month DD, Year | Slide 8
PASS Plug And Switch System
Combined disconnector and earthing switch
Integrated DS\ES
ABB Group
July 10, 2013 | Slide 9
PASS Plug And Switch System
Portholes for safe earthing
ABB Group
July 10, 2013 | Slide 10
PASS Plug And Switch System
DS\ES drive indicator for safety
ABB Group
July 10, 2013 | Slide 11
PASS Plug And Switch System
Gas density control
Density monitor
Since the dielectric strength of
the switchgear and the breaking
capacity of the SF6 circuit-
breaker depend on the density
of the SF6 gas, a gas density
relay is installed to control gas
density and detect leakage.
ABB Group
July 10, 2013 | Slide 12
PASS Plug And Switch System
Current Transformers
ABB Group
July 10, 2013 | Slide 13
PASS Plug And Switch System
Voltage Transformers and Surge Arresters
ABB Group
July 10, 2013 | Slide 14
PASS Plug And Switch System
Bushings
Explosion proof
Maximum safety of personnel and
Glass fiber reinforced equipment
epoxy resin tube Non-brittle
Reduced handling damage risk
Low weight
Easier handling and reduced
Silicone rubber sheds foundation loads
Maintenance free
No cleaning in polluted
environments
Outstanding seismic
performance
Aluminum end fitting For best safety and reliability
ABB Group
July 10, 2013 | Slide 15
Agenda
Schedule
What is PASS
PASS benefits
Success Stories and references
ABB Group
July 10, 2013 | Slide 16
Why Innovative Switchgear
Advantages
ABB Group
July 10, 2013 | Slide 17
Why Innovative Switchgear
Flexibility
ABB Group
July 10, 2013 | Slide 18
Why Innovative Switchgear
Flexibility
ABB Group
July 10, 2013 | Slide 19
Why Innovative Switchgear
Flexibility
ABB Group
July 10, 2013 | Slide 20
145 kV H5 Substation Layout
Top View comparison
ABB Group
July 10, 2013 | Slide 21
145 kV H5 Substation Layout
3d Comparison
AIS
PASS M0
ABB Group
July 10, 2013 | Slide 22
145 kV H5 Substation Layout
Chart and benefits
Space Comparison
PASS
AIS
ABB Group
July 10, 2013 | Slide 23
245 kV H3 Substation Layout
Top View comparison
ABB Group
July 10, 2013 | Slide 24
245 kV H3 Substation Layout
Chart and benefits
Space Comparison
PASS
AIS
ABB Group
July 10, 2013 | Slide 25
Innovation with PASS
PASS M0H module Multifunctional Module
Transportable
No high voltage
test on site
Advantages:
ABB Group
July 10, 2013 | Slide 26
Innovation with PASS
PASS M0H module Multifunctional Module
Pre-assembled
Pretested
Transportable
No high voltage
test on site
ABB Group
July 10, 2013 | Slide 27
Why Innovative Switchgear
Space Saving
ABB Group
July 10, 2013 | Slide 28
Why Innovative Switchgear
Easy transportability
ABB Group
Month DD, Year | Slide 29
Why Innovative Switchgear
Easy transportability
ABB Group
Month DD, Year | Slide 30
Why Innovative Switchgear
Easy transportability
PASS M0 on a skid
ABB Group
Month DD, Year | Slide 31
Why Innovative Switchgear
Easy transportability
Transport
configuration
Service
configuration
ABB Group
Month DD, Year | Slide 32
Why Innovative Switchgear
Erection & Commissioning
Service position
Erection on
support
structure
Transport
module
ABB Group
July 10, 2013 | Slide 33
Why Innovative Switchgear
Ideal solution for fast track projects
ABB Group
July 10, 2013 | Slide 34
Why Innovative Switchgear
Financial comparison
ABB Group
July 10, 2013 | Slide 35
Agenda
Schedule
What is PASS
PASS benefits
Success Stories and references
ABB Group
July 10, 2013 | Slide 36
PASS M0S 245 kV - Compactness
Tenaris Dalmine co-generation plant
ABB Group
June 22, 2012 | Slide 37
PASS M0 145 kV - Retrofitting
Tauron Welnowiec
ABB Group
June 22, 2012 | Slide 38
PASS M00 72.5 kV - Extension
GEG Grenoble
ABB Group
June 22, 2012 | Slide 39
PASS M0 145 kV Reliability
Saudi Aramco - Shaybah e Abquaiq substations
Pre-assembled
Customer need
Pre-tested
Refurbishment of two old AIS S/S minimizing the
Trasportable
No HV test on site
outage and installation time
Utilize pre-existing bus bar system and AIS
equipments (PT, SA)
ABB response
ABB supplied 10 completed HV bays made by
Hybrid switchgears type PASS M0 in SBB and
DBB configuration (132 kV)
ABB optimized the PASS design to be suitable
for aggressive environmental condition (Desert
storm, +52 C, High solar radiation)
Customer benefits
Costs and time saving during erection and
commissioning
Reduced outage time during S/S revamping
ABB Group
July 10, 2013 | Slide 40
PASS M00 72,5 kV - Safety
Interlocking safety system for mining industry in Australia
ABB Group
June 22, 2012 | Slide 41
PASS M0 H 145 kV Fast Erection & Commissioning
Samsung Engineering for Lukoil in Iraq
ABB Group
June 22, 2012 | Slide 42
PASS The ABB Hybrid Module
Reference Map
More than 5500 modules installed at July 2012
More than 7500 equivalent bays*
*
SBB = 1 bay equivalent
DBB = 1,5 bay equivalent
DCB = 2 bays equivalent
ABB Group
July 10, 2013 | Slide 43