You are on page 1of 2

REM615

Motor Protection and Control

Selected Order No. H B M A AC AD N A A 1 B N N 1 X G Valid


Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18
IED
Complete Relay H
Complete Relay with test switch installed and wired in 19'' cover plate
Additional price for configuration A K
Note! Not available for standard configuration "D".
Complete Relay with test switch installed and wired in 19'' cover plate
Additional price for configuration B K
Note! Not available for standard configuration "D"
Complete Relay with test switch installed and wired in 19'' cover plate
Additional price for configuration C K
Note! Not available for standard configuration "D"
Complete Relay with test switch installed and wired for CombiFlex rack mounting
Additional price for configuration A L
Note! Not available for standard configuration "D"
Complete Relay with test switch installed and wired for CombiFlex rack mounting
Additional price for configuration B L
Note! Not available for standard configuration "D"
Complete Relay with test switch installed and wired for CombiFlex rack mounting
Additional price for configuration C L
Note! Not available for standard configuration "D"

Standard
IEC B

Main Application
Motor protection and control M

Standard configuration (descriptions in short)


A = Motor protection, optional RTD/mA inputs A
B = Motor protection with current, voltage and frequency based
B
protection and measurement functions, optional RTD/mA inputs
C = Motor protection with current and voltage based protection
C
and measurement functions
D = Motor protection with voltage & frequency based protection and measurements
D
(Sensor inputs)

Analog Inputs/Outputs
Std conf A: 4I (Io 1/5A) A AC
Std conf A: 4I (Io 0.2/1A) A AD
Std conf C: 4I (Io 1/5A) + 5U C AE
Std conf C: 4I (Io 0.2/1A) + 5U C AF
Std conf A: 4I (Io 1/5A) + 2mA + 6RTD A AG
Std conf A: 4I (Io 0.2/1A) + 2mA + 6RTD A AH
Std conf B: 4I + 3U (Io 1/5A) B CA
Std conf B: 4I + 3U (Io 0.2/1A) B CB
Std conf B: 4I (Io 1/5A) + 3U + 2mA + 6RTD B CC
Std conf B: 4I (Io 0.2/1A) + 3U + 2mA + 6RTD B CD
Std conf D: 3Is + 3Us + Io (Io 0.2/1A) D DA

Binary Inputs/Outputs
4BI+6BO Only for Standard Configuration A AB
12BI+10BO Only for Standard Configuration A AD
12BI+6BO+3HSO Only for Standard Configuration A FE
16BI+10BO Only for Standard Configuration C AG
16BI+6BO+3HSO Only for Standard Configuration C FC
8BI+10BO Only for Standard Configuration B and D AH
Only for Standard Configuration B
14BI + 13BO
Note! Order No. 5/6 must be CA or CB
AJ

8BI+6BO+3HSO Only for Standard Configuration B and D FD


Only for Standard Configuration B
14BI+9BO+3HSO
Note! Order No. 5/6 must be CA or CB
FF

Communication (Serial/Ethernet)
RS 485 (including IRIG-B) + Ethernet 100Base FX (LC) A A
RS 485 (including IRIG-B) + Ethernet 100Base TX (RJ45) A B
RS 485 (including IRIG-B) A N
Glassfibre ST + Ethernet 100Base TX (RJ45) B B
Glassfibre ST + Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP B C
Glassfibre ST + Ethernet 100Base TX (3xRJ45) with HSR/PRP B D
Glassfibre ST + Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP B E
Glassfibre ST + Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP and
Not available for Standard Configuration A B F
IEC61850-9-2LE
Glassfibre ST + Ethernet 100Base TX (3xRJ45) with HSR/PRP and
Not available for Standard Configuration A B G
IEC61850-9-2LE
Glassfibre ST + Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP and
Not available for Standard Configuration A B H
IEC61850-9-2LE
Glassfibre ST B N
RS 232/485 (including IRIG-B) + Ethernet 100Base TX (RJ45) C B
RS 232/485 + RS485 / Glassfibre ST (including IRIG-B) C N
Ethernet 100Base FX (LC) N A
Ethernet 100Base TX (RJ45) N B
Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP N C
Ethernet 100Base TX (3xRJ45) with HSR/PRP N D
Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP N E
Ethernet 100Base FX (1xLC, 2xRJ45) with HSR/PRP and IEC61850-9-2LE Not available for Standard Configuration A N F
Ethernet 100Base TX (3xRJ45) with HSR/PRP and IEC61850-9-2LE Not available for Standard Configuration A N G
Ethernet 100Base FX (2xLC, 1xRJ45) with HSR/PRP and IEC61850-9-2LE Not available for Standard Configuration A N H
None N N

Communication (Protocol)
IEC 61850 Only when Order No. 9 = N A
Modbus B
IEC 61850+Modbus C
IEC 103 D
REM615
Motor Protection and Control

Selected Order No. H B M A AC AD N A A 1 B N N 1 X G Valid


Instructions / Order No. Pos. 1 2 3 4 5/6 7/8 9 10 11 12 13 14 15 16 17 18
DNP 3.0 E
IEC 61850 + IEC103 G
IEC 61850 + DNP 3.0 H

Language
English 1
English and German 3
English and Swedish 4
English and Spanish 5
English and Russian 6
English and Polish 7
English and Italian A
English and French C
English and Czech E
English and Turkish L

Front Panel
Small LCD A
Large LCD with Single Line Diagram B

Option 1
NOT allowed when Order No.
Arc protection
9/10 = BB,BN,CB,CN or NN
B

None N

Option 2
None N

Power Supply
48-250 Vdc; 100-240 Vac 1
24-60 Vdc 2

Version
Product Version 5.0 X G

Mounting accessories and arc sensors for REM615

Description Order No.


Semi-flush mounting kit 1MRS050696
Wall mounting kit 1MRS050697
Inclined semi-flush mounting kit 1MRS050831
19 rack mounting kit with cut-out for one IED 1MRS050694
19 rack mounting kit with cut-out for two IEDs 1MRS050695
Mounting bracket for one IED with test switch RTXP in 4U Combiflex
2RCA022642P0001
(RHGT 19 variant C)
Mounting bracket for one IED in 4U Combiflex (RHGT 19 variant C) 2RCA022643P0001
19 rack mounting kit for one IED and one RTXP18 test switch (the
2RCA021952A0003
test switch is not included in the delivery)
19 rack mounting kit for one IED and one RTXP24 test switch (the
2RCA022561A0003
test switch is not included in the delivery)
Cable for optical sensors for arc protection 1.5 m 1MRS120534-1.5
Cable for optical sensors for arc protection 3.0 m 1MRS120534-3
Cable for optical sensors for arc protection 5.0 m 1MRS120534-5

You might also like