You are on page 1of 90

Ref Calculation Output

Specification

ROOF

Characteristic Action:
Parmenent, gk = 0.5 kN/m (Excluding Selfweight)
Variable, qk = 4 kN/m
Design Life = 50 Years
Fire Resistance = 1 Hour
Exposure Class = XC3
Materials:
Characteristic strength of concrete, fck = 25 N/mm
Characteristic strength of steel, fyk = 500 N/mm
Unit weight of concrete = 25 kN/m
Assumed bar bar = 12 mm

SLAB THICKNESS
Estimated thickness considering deflection control, Try
h = 5000 / 25 = 200.00 mm 200
BEAM SIZE Try
Overall depth, h = L/13 = 5000 / 13 = 384.62 mm 400
Width, b = 0.4h = 0.4 x 384.62 = 153.85 mm 200
Use: b x h
200 x 400 mm

Ref Calculation Output

LOADING
Loads on slab

Selfweight = 0.20 x 25 = 5.00 kN/m


Finishing ceiling and service = 0.50 kN/m
Chac. Parmenent action, gk = 5.50 kN/m
Chac. Variable action, qk = 4.00 kN/m

Beam A1-2 / A8-9

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.35 x 5.50 x 2 = 3.85 kN/m
Gk = 5.85 kN/m
Characteristic variable load
w1 = 0.35 x 4.00 x 2 = 2.80 kN/m
Qk = 2.80 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 12.10 kN/m
w = 1.35Gk = 7.90 kN/m

Ref Calculation Output

Beam A2-3 / A3-4 / A6-7 / A7-8

Distribution of action from slab


FF = Ly/Lx 2000 / 2000 = 1.00 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.24 x 5.50 x 2 = 2.64 kN/m
Gk = 4.64 kN/m

Characteristic variable load


w1 = 0.24 x 4.00 x 2 = 1.92 kN/m
Qk = 1.92 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 9.14 kN/m
w = 1.35Gk = 6.26 kN/m

Beam A4-5 / A5-6

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.34 x 5.50 x 2 = 3.74 kN/m
Gk = 5.74 kN/m

Characteristic variable load


w1 = 0.34 x 0.50 x 2 = 0.34 kN/m
Qk = 0.34 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 8.26 kN/m
w = 1.35Gk = 7.75 kN/m

Ref Calculation Output

Beam B1-2 / B8-9

Distribution of action from slab


FF = Ly/Lx 3000 / 3000 = 1.00 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 5.50 x 3 = 5.94 kN/m
w2 = 0.54 x 5.50 x 2 = 5.94 kN/m
Gk = 13.88 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 3 = 4.32 kN/m
w2 = 0.54 x 4.00 x 2 = 4.32 kN/m
Qk = 8.64 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 31.70 kN/m
w = 1.35Gk = 18.74 kN/m

Beam B2-3 / B3-4 / B6-7 / B7-8


Distribution of action from slab
FF = Ly/Lx 3000 / 2000 = 1.50 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.33 x 5.50 x 2 = 3.63 kN/m
w2 = 0.36 x 5.50 x 2 = 3.96 kN/m
Gk = 9.59 kN/m
Characteristic variable load
w1 = 0.33 x 4.00 x 2 = 2.64 kN/m
w2 = 0.36 x 4.00 x 2 = 2.88 kN/m
Qk = 5.52 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 21.23 kN/m
w = 1.35Gk = 12.95 kN/m

Ref Calculation Output

Beam B4-5 / B5-6

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.33 x 5.50 x 3 = 5.45 kN/m
w2 = 0.51 x 4.00 x 2 = 4.08 kN/m
Gk = 11.53 kN/m
Characteristic variable load
w1 = 0.33 x 4.00 x 3 = 3.96 kN/m
w2 = 0.51 x 4.00 x 2 = 4.08 kN/m
Qk = 8.04 kN/m
Total design load on beam
w = 1.35Gk + 1.5Qk = 27.62 kN/m
w = 1.35Gk = 15.56 kN/m

Beam C1-2 / C8-9

Distribution of action from slab


FF = Ly/Lx 5000 / 3000 = 1.67 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 5.50 x 3 = 5.94 kN/m
w2 = 0.36 x 5.50 x 3 = 5.94 kN/m
Gk = 13.88 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 3 = 4.32 kN/m
w2 = 0.36 x 4.00 x 3 = 4.32 kN/m
Qk = 8.64 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 31.70 kN/m
w = 1.35Gk = 18.74 kN/m

Ref Calculation Output

Beam C2-3 / C3-4 / C6-7 / C7-8

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2 One way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.33 x 5.50 x 2 = 3.63 kN/m
Gk = 5.63 kN/m
Characteristic variable load
w1 = 0.33 x 4.00 x 2 = 2.64 kN/m

Qk = 2.64 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 11.56 kN/m
w = 1.35Gk = 7.60 kN/m

Beam C4-5 / C5-6

Distribution of action from slab


FF = Ly/Lx 5000 / 3000 = 1.67 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.33 x 5.50 x 3 = 5.45 kN/m
w2 = 0.33 x 5.50 x 3 = 5.45 kN/m
Gk = 12.89 kN/m
Characteristic variable load
w1 = 0.33 x 4.00 x 3 = 3.96 kN/m
w2 = 0.33 x 4.00 x 3 = 3.96 kN/m
Qk = 7.92 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 29.28 kN/m
w = 1.35Gk = 17.40 kN/m

Ref Calculation Output

Beam D1-2 / D8-9

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2 One way slab
Action from slab
Formula = v.n.lx
Characteristic parmenent load
wo 0.4 x 0.4 x 25 = 4 kN/m
w1 = 0.5 x 5.50 x 2 = 5.50 kN/m
w2 = 0.36 x 5.50 x 3 = 5.94 kN/m
Gk = 15.44 kN/m
Characteristic variable load
w1 = 0.5 x 4.00 x 2 = 4.00 kN/m
w2 = 0.36 x 4.00 x 3 = 4.32 kN/m
Qk = 8.32 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 33.32 kN/m
w = 1.35Gk = 20.84 kN/m

Beam D2-3 / D3-4 / D6-7 / D7-8

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2 One way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.5 x 5.50 x 2 = 5.50 kN/m

Gk = 7.50 kN/m
Characteristic variable load
w1 = 0.5 x 4.00 x 2 = 4.00 kN/m

Qk = 4.00 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 16.13 kN/m
w = 1.35Gk = 10.13 kN/m

Ref Calculation Output


Beam D4-5 / D5-6

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2 One way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.5 x 5.50 x 2 = 5.50 kN/m
w2 = 0.33 x 5.50 x 3 = 5.45 kN/m
Gk = 12.95 kN/m
Characteristic variable load
w1 = 0.5 x 4.00 x 2 = 4.00 kN/m
w2 = 0.33 x 4.00 x 3 = 3.96 kN/m
Qk = 7.96 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 29.42 kN/m
w = 1.35Gk = 17.48 kN/m

Beam E1-3 / E3-5 / E5-7 / E7-9

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2 One way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.5 x 5.50 x 2 = 5.50 kN/m
Gk = 7.50 kN/m

Characteristic variable load


w1 = 0.5 x 4.00 x 2 = 4.00 kN/m
Qk = 4.00 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 16.13 kN/m
w = 1.35Gk = 10.13 kN/m
Output Ref Calculation

Beam 1A-B / 9A-B

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.26 x 5.50 x 2 = 2.86 kN/m
Gk = 4.86 kN/m

Characteristic variable load


w1 = 0.26 x 4.00 x 2 = 2.08 kN/m
Qk = 2.08 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 9.68 kN/m
w = 1.35Gk = 6.56 kN/m

Beam 1B-C/ 9B-C

Distribution of action from slab


FF = Ly/Lx 3000 / 3000 = 1.00 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.24 x 5.50 x 3 = 3.96 kN/m
Gk = 5.96 kN/m

Characteristic variable load


w1 = 0.24 x 4.00 x 3 = 2.88 kN/m
Qk = 2.88 kN/m

mm Total design load on beam


w = 1.35Gk + 1.5Qk = 12.37 kN/m
w = 1.35Gk = 8.05 kN/m
mm
mm
Use: b x h
200 x 400 mm

Output Ref Calculation

Beam 1C-D / 9C-D

Distribution of action from slab


FF = Ly/Lx 5000 / 3000 = 1.67 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 5.50 x 5 = 9.90 kN/m
Gk = 11.90 kN/m

Characteristic variable load


w1 = 0.36 x 4.00 x 5 = 7.20 kN/m
Qk = 7.20 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 26.87 kN/m
w = 1.35Gk = 16.07 kN/m

Beam 1D-E / 3D-E / 5D-E 7D-E / 9D-E

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2
Two way slab
Action from slab
Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m

Gk = 2.00 kN/m

Characteristic variable load


Qk = 0.00 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 2.70 kN/m

Output Ref Calculation

Beam 2A-B / 8A-B

Distribution of action from slab


Two way slab FF = Ly/Lx 2000 / 2000 = 1.00 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 5.50 x 2 = 3.96 kN/m
w2 = 0.4 x 5.50 x 2 = 4.40 kN/m
Gk = 10.36 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 2 = 2.88 kN/m
w2 = 0.4 x 4.00 x 2 = 3.20 kN/m
Qk = 6.08 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 23.11 kN/m
w = 1.35Gk = 13.99 kN/m

Beam 2B-C / 8B-C

Distribution of action from slab


Two way slab FF = Ly/Lx 3000 / 2000 = 1.50 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.45 x 5.50 x 2 = 4.95 kN/m
w2 = 0.36 x 5.50 x 2 = 3.96 kN/m
Gk = 10.91 kN/m
Characteristic variable load
w1 = 0.45 x 4.00 x 2 = 3.60 kN/m
w2 = 0.36 x 4.00 x 2 = 2.88 kN/m
Qk = 6.48 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 24.45 kN/m
w = 1.35Gk = 14.73 kN/m

Output Ref Calculation

Beam 2C-D / 8C-D

Distribution of action from slab


Two way slab FF = Ly/Lx 5000 / 3000 = 1.67 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.5 x 5.50 x 2 = 5.50 kN/m
w2 = 0.55 x 5.50 x 2 = 6.05 kN/m
Gk = 13.55 kN/m
Characteristic variable load
w1 = 0.5 x 4.00 x 2 = 4.00 kN/m
w2 = 0.55 x 4.00 x 2 = 4.40 kN/m
Qk = 8.40 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 30.89 kN/m
w = 1.35Gk = 18.29 kN/m

Beam 3A-B / 7A-B


Distribution of action from slab
Two way slab FF = Ly/Lx 2000 / 2000 = 1.00 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 5.50 x 2 = 3.96 kN/m
w2 = 0.36 x 5.50 x 2 = 3.96 kN/m
Gk = 9.92 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 2 = 2.88 kN/m
w2 = 0.36 x 4.00 x 2 = 2.88 kN/m
Qk = 5.76 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 22.03 kN/m
w = 1.35Gk = 13.39 kN/m

Output Ref Calculation

Beam 3B-C / 7B-C

Distribution of action from slab


Two way slab FF = Ly/Lx 3000 / 2000 = 1.50 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.45 x 5.50 x 2 = 4.95 kN/m
w2 = 0.45 x 5.50 x 2 = 4.95 kN/m
Gk = 11.90 kN/m
Characteristic variable load
w1 = 0.45 x 4.00 x 2 = 3.60 kN/m
w2 = 0.45 x 4.00 x 2 = 3.60 kN/m
Qk = 7.20 kN/m
Total design load on beam
w = 1.35Gk + 1.5Qk = 26.87 kN/m
w = 1.35Gk = 16.07 kN/m

Beam 3C-D / 7C-D

Distribution of action from slab


Two way slab FF = Ly/Lx 5000 / 5000 = 1.00 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.5 x 5.50 x 2 = 5.50 kN/m
w2 = 0.5 x 5.50 x 2 = 5.50 kN/m
Gk = 13.00 kN/m
Characteristic variable load
w1 = 0.5 x 4.00 x 2 = 4.00 kN/m
w2 = 0.5 x 4.00 x 2 = 4.00 kN/m
Qk = 8.00 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 29.55 kN/m
w = 1.35Gk = 17.55 kN/m

Output Ref Calculation

Beam 4A-B / 6A-B

Distribution of action from slab


One way slab FF = Ly/Lx 2000 / 2000 = 1.00 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 5.50 x 2 = 3.96 kN/m
w2 = 0.36 x 5.50 x 2 = 3.96 kN/m
Gk = 9.92 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 2 = 2.88 kN/m
w2 = 0.36 x 4.00 x 2 = 2.88 kN/m
Qk = 5.76 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 22.03 kN/m
w = 1.35Gk = 13.39 kN/m

Beam 4B-C / 6B-C

Distribution of action from slab


Two way slab FF = Ly/Lx 3000 / 2000 = 1.50 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.33 x 5.50 x 3 = 5.45 kN/m
w2 = 0.45 x 5.50 x 3 = 7.43 kN/m
Gk = 14.87 kN/m
Characteristic variable load
w1 = 0.33 x 4.00 x 3 = 3.96 kN/m
w2 = 0.45 x 4.00 x 3 = 5.40 kN/m
Qk = 9.36 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 34.11 kN/m
w = 1.35Gk = 20.07 kN/m

Output Ref Calculation

Beam 4C-D / 6C-D

Distribution of action from slab


One way slab FF = Ly/Lx 3000 / 2000 = 1.50 < 2
Action from slab
Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.48 x 5.50 x 3 = 7.92 kN/m
w2 = 0.5 x 5.50 x 2 = 5.50 kN/m
Gk = 15.42 kN/m
Characteristic variable load
w1 = 0.48 x 4.00 x 3 = 5.76 kN/m
w2 = 0.5 x 4.00 x 2 = 4.00 kN/m
Qk = 9.76 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 35.46 kN/m
w = 1.35Gk = 20.82 kN/m

Beam 5A-B

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2
One way slab
Action from slab
Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 5.50 x 2 = 3.96 kN/m
w2 = 0.36 x 5.50 x 2 = 3.96 kN/m
Gk = 9.92 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 2 = 2.88 kN/m
w2 = 0.36 x 4.00 x 2 = 2.88 kN/m
Qk = 5.76 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 22.03 kN/m
w = 1.35Gk = 13.39 kN/m

Output Ref Calculation


Beam 5B-C

Distribution of action from slab


One way slab FF = Ly/Lx 3000 / 3000 = 1.00 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.33 x 5.50 x 3 = 5.45 kN/m
w2 = 0.33 x 5.50 x 3 = 5.45 kN/m
Gk = 12.89 kN/m
Characteristic variable load
w1 = 0.33 x 4.00 x 3 = 3.96 kN/m
w2 = 0.33 x 4.00 x 3 = 3.96 kN/m
Qk = 7.92 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 29.28 kN/m
w = 1.35Gk = 17.40 kN/m

Beam 5C-D

Distribution of action from slab


FF = Ly/Lx 5000 / 3000 = 1.67 < 2
One way slab
Action from slab
Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.48 x 5.50 x 3 = 7.92 kN/m
w2 = 0.48 x 5.50 x 3 = 7.92 kN/m
Gk = 17.84 kN/m
Characteristic variable load
w1 = 0.48 x 4.00 x 3 = 5.76 kN/m
w2 = 0.48 x 4.00 x 3 = 5.76 kN/m
Qk = 11.52 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 41.36 kN/m
w = 1.35Gk = 24.08 kN/m
Output

Two way slab

Two way slab


Output

One way slab


Output

Two way slab

Two way slab


Output

Two way slab


Two way slab

Output

Two way slab


Two way slab

Output

Two way slab


Two way slab

Output

Two way slab


Two way slab

Output
Two way slab

Two way slab


Ref Calculation Output

Specification

1st, 2nd, 3rd FLOOR

Characteristic Action:
Parmenent, gk = 1.5 kN/m (Excluding Selfweight)
Variable, qk = 4 kN/m
Design Life = 50 Years
Fire Resistance = 1 Hour
Exposure Class = XC3
Materials:
Characteristic strength of concrete, fck = 25 N/mm
Characteristic strength of steel, fyk = 500 N/mm
Unit weight of concrete = 25 kN/m
Weight of brickwork = 2.6 kN/m
Wallheight = 3m

SLAB THICKNESS
Estimated thickness considering deflection control, Try
h = 5000 / 25 = 200.00 mm 200
BEAM SIZE Try
Overall depth, h = L/13 = 5000 / 13 = 384.62 mm 400
Width, b = 0.4h = 0.4 x 384.62 = 153.85 mm 200
Use: b x h
200 x 400 mm

Ref Calculation Output

LOADING
Loads on slab

Selfweight = 0.20 x 25 = 5.00 kN/m


Finishing ceiling and service = 1.50 kN/m
Chac. Parmenent action, gk = 6.50 kN/m
Chac. Variable action, qk = 4.00 kN/m

Beam A1-2 / A8-9

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.35 x 6.50 x 2 = 4.55 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 14.35 kN/m
Characteristic variable load
w1 = 0.35 x 4.00 x 2 = 2.80 kN/m
Qk = 2.80 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 23.57 kN/m
w = 1.35Gk = 19.37 kN/m

Ref Calculation Output

Beam A2-3 / A3-4 / A6-7 / A7-8

Distribution of action from slab


FF = Ly/Lx 2000 / 2000 = 1.00 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.24 x 6.50 x 2 = 3.12 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 12.92 kN/m
Characteristic variable load
w1 = 0.24 x 4.00 x 2 = 1.92 kN/m
Qk = 1.92 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 20.32 kN/m
w = 1.35Gk = 17.44 kN/m

Beam A4-5 / A5-6

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.34 x 6.50 x 2 = 4.42 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 14.22 kN/m
Characteristic variable load
w1 = 0.34 x 1.50 x 2 = 1.02 kN/m
Qk = 1.02 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 20.73 kN/m
w = 1.35Gk = 19.20 kN/m

Ref Calculation Output

Beam B1-2 / B8-9

Distribution of action from slab


FF = Ly/Lx 3000 / 3000 = 1.00 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 6.50 x 3 = 7.02 kN/m
w2 = 0.54 x 6.50 x 2 = 7.02 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 23.84 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 3 = 4.32 kN/m
w2 = 0.54 x 4.00 x 2 = 4.32 kN/m
Qk = 8.64 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 45.14 kN/m
w = 1.35Gk = 32.18 kN/m
Beam B2-3 / B3-4 / B6-7 / B7-8

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 6.50 x 2 = 4.68 kN/m
w2 = 0.36 x 6.50 x 2 = 4.68 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 19.16 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 2 = 2.88 kN/m
w2 = 0.36 x 4.00 x 2 = 2.88 kN/m
Qk = 5.76 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 34.51 kN/m
w = 1.35Gk = 25.87 kN/m

Ref Calculation Output

Beam B4-5 / B5-6

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.33 x 6.50 x 3 = 6.44 kN/m
w2 = 0.51 x 4.00 x 2 = 4.08 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 20.32 kN/m
Characteristic variable load
w1 = 0.33 x 4.00 x 3 = 3.96 kN/m
w2 = 0.51 x 4.00 x 2 = 4.08 kN/m
Qk = 8.04 kN/m
Total design load on beam
w = 1.35Gk + 1.5Qk = 39.49 kN/m
w = 1.35Gk = 27.43 kN/m

Beam C1-2 / C8-9

Distribution of action from slab


FF = Ly/Lx 5000 / 3000 = 1.67 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.4 x 6.50 x 3 = 7.80 kN/m
w2 = 0.36 x 6.50 x 3 = 7.02 kN/m
Gk = 16.82 kN/m
Characteristic variable load
w1 = 0.4 x 4.00 x 3 = 4.80 kN/m
w2 = 0.36 x 4.00 x 3 = 4.32 kN/m
Qk = 9.12 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 36.39 kN/m
w = 1.35Gk = 22.71 kN/m

Ref Calculation Output

Beam C2-3 / C3-4 / C6-7 / C7-8

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2 One way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.24 x 6.50 x 2 = 3.12 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 12.92 kN/m
Characteristic variable load
w1 = 0.24 x 4.00 x 2 = 1.92 kN/m

Qk = 1.92 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 20.32 kN/m
w = 1.35Gk = 17.44 kN/m

Beam C4-5 / C5-6

Distribution of action from slab


FF = Ly/Lx 5000 / 3000 = 1.67 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.4 x 6.50 x 3 = 7.80 kN/m
w2 = 0.33 x 6.50 x 3 = 6.44 kN/m
Gk = 16.24 kN/m
Characteristic variable load
w1 = 0.4 x 4.00 x 3 = 4.80 kN/m
w2 = 0.33 x 4.00 x 3 = 3.96 kN/m
Qk = 8.76 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 35.06 kN/m
w = 1.35Gk = 21.92 kN/m

Ref Calculation Output

Beam D1-2 / D8-9

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2 One way slab
Action from slab
Formula = v.n.lx
Characteristic parmenent load
wo 0.4 x 0.4 x 25 = 4 kN/m
w1 = 0.5 x 6.50 x 2 = 6.50 kN/m
w2 = 0.4 x 6.50 x 3 = 7.80 kN/m
Gk = 18.30 kN/m
Characteristic variable load
w1 = 0.5 x 4.00 x 2 = 4.00 kN/m
w2 = 0.4 x 4.00 x 3 = 4.80 kN/m
Qk = 8.80 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 37.91 kN/m
w = 1.35Gk = 24.71 kN/m

Beam D2-3 / D3-4 / D6-7 / D7-8

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2 One way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.5 x 6.50 x 2 = 6.50 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 16.30 kN/m
Characteristic variable load
w1 = 0.5 x 4.00 x 2 = 4.00 kN/m

Qk = 4.00 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 28.01 kN/m
w = 1.35Gk = 22.01 kN/m

Ref Calculation Output


Beam D4-5 / D5-6

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2 One way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.5 x 6.50 x 2 = 6.50 kN/m
w2 = 0.4 x 6.50 x 3 = 7.80 kN/m
Gk = 16.30 kN/m
Characteristic variable load
w1 = 0.5 x 4.00 x 2 = 4.00 kN/m
w2 = 0.4 x 4.00 x 3 = 4.80 kN/m
Qk = 8.80 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 35.21 kN/m
w = 1.35Gk = 22.01 kN/m

Beam E1-3 / E3-5 / E5-7 / E7-9

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2 One way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.5 x 6.50 x 2 = 6.50 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 16.30 kN/m
Characteristic variable load
w1 = 0.5 x 4.00 x 2 = 4.00 kN/m
Qk = 4.00 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 28.01 kN/m
w = 1.35Gk = 22.01 kN/m
Output Ref Calculation

Beam 1A-B / 9A-B

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.26 x 6.50 x 2 = 3.38 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 13.18 kN/m
Characteristic variable load
w1 = 0.26 x 4.00 x 2 = 2.08 kN/m
Qk = 2.08 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 20.91 kN/m
w = 1.35Gk = 17.79 kN/m

Beam 1B-C/ 9B-C

Distribution of action from slab


FF = Ly/Lx 3000 / 3000 = 1.00 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.24 x 6.50 x 3 = 4.68 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 14.48 kN/m
Characteristic variable load
w1 = 0.24 x 4.00 x 3 = 2.88 kN/m
Qk = 2.88 kN/m

mm Total design load on beam


w = 1.35Gk + 1.5Qk = 23.87 kN/m
w = 1.35Gk = 19.55 kN/m
mm
mm
Use: b x h
200 x 400 mm

Output Ref Calculation

Beam 1C-D / 9C-D

Distribution of action from slab


FF = Ly/Lx 5000 / 3000 = 1.67 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.44 x 6.50 x 5 = 14.30 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 24.10 kN/m
Characteristic variable load
w1 = 0.44 x 4.00 x 5 = 8.80 kN/m
Qk = 8.80 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 45.74 kN/m
w = 1.35Gk = 32.54 kN/m

Beam 1D-E / 3D-E / 5D-E 7D-E / 9D-E

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2
Two way slab
Action from slab
Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
Brickwall, w1 = 2.6 x 3.00 = 7.8 kN/m
Gk = 9.80 kN/m

Characteristic variable load


Qk = 0.00 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 13.23 kN/m
w = 1.35Gk = 13.23 kN/m

Output Ref Calculation

Beam 2A-B / 8A-B

Distribution of action from slab


Two way slab FF = Ly/Lx 2000 / 2000 = 1.00 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 6.50 x 2 = 4.68 kN/m
w2 = 0.4 x 6.50 x 2 = 5.20 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 19.68 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 2 = 2.88 kN/m
w2 = 0.4 x 4.00 x 2 = 3.20 kN/m
Qk = 6.08 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 35.69 kN/m
w = 1.35Gk = 26.57 kN/m

Beam 2B-C / 8B-C

Two way slab Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.47 x 6.50 x 2 = 6.11 kN/m
w2 = 0.36 x 6.50 x 2 = 4.68 kN/m
Gk = 12.79 kN/m
Characteristic variable load
w1 = 0.47 x 4.00 x 2 = 3.76 kN/m
w2 = 0.36 x 4.00 x 2 = 2.88 kN/m
Qk = 6.64 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 27.23 kN/m
w = 1.35Gk = 17.27 kN/m

Output Ref Calculation

Beam 2C-D / 8C-D

Distribution of action from slab


Two way slab FF = Ly/Lx 5000 / 3000 = 1.67 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.44 x 6.50 x 3 = 8.58 kN/m
Brickwall, w2 = 2.6 x 3.00 = 7.8 kN/m
Gk = 18.38 kN/m
Characteristic variable load
w1 = 0.44 x 4.00 x 3 = 5.28 kN/m

Qk = 5.28 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 32.73 kN/m
w = 1.35Gk = 24.81 kN/m

Beam 3A-B / 7A-B


Distribution of action from slab
FF = Ly/Lx 2000 / 2000 = 1.00 < 2
Two way slab
Action from slab
Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 6.50 x 2 = 4.68 kN/m
w2 = 0.36 x 6.50 x 2 = 4.68 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 19.16 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 2 = 2.88 kN/m
w2 = 0.36 x 4.00 x 2 = 2.88 kN/m
Qk = 5.76 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 34.51 kN/m
w = 1.35Gk = 25.87 kN/m

Output Ref Calculation

Beam 3B-C / 7B-C

Distribution of action from slab


Two way slab FF = Ly/Lx 3000 / 2000 = 1.50 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.47 x 6.50 x 2 = 6.11 kN/m
w2 = 0.47 x 6.50 x 2 = 6.11 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 22.02 kN/m
Characteristic variable load
w1 = 0.47 x 4.00 x 2 = 3.76 kN/m
w2 = 0.47 x 4.00 x 2 = 3.76 kN/m
Qk = 7.52 kN/m
Total design load on beam
w = 1.35Gk + 1.5Qk = 41.01 kN/m
w = 1.35Gk = 29.73 kN/m

Beam 3C-D / 7C-D

Two way slab Distribution of action from slab


FF = Ly/Lx 5000 / 3000 = 1.67 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
Brickwall, w1 = 2.6 x 3.00 = 7.8 kN/m

Gk = 9.80 kN/m
Characteristic variable load
Qk = 0.00 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 13.23 kN/m
w = 1.35Gk = 13.23 kN/m

Output Ref Calculation

Beam 4A-B / 6A-B

Distribution of action from slab


One way slab FF = Ly/Lx 2000 / 2000 = 1.00 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 6.50 x 2 = 4.68 kN/m
w2 = 0.36 x 6.50 x 2 = 4.68 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 19.16 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 2 = 2.88 kN/m
w2 = 0.36 x 4.00 x 2 = 2.88 kN/m
Qk = 5.76 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 34.51 kN/m
w = 1.35Gk = 25.87 kN/m

Beam 4B-C / 6B-C


Two way slab
Distribution of action from slab
FF = Ly/Lx 3000 / 2000 = 1.50 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.33 x 6.50 x 3 = 6.44 kN/m
w2 = 0.47 x 6.50 x 3 = 9.17 kN/m
Gk = 17.60 kN/m
Characteristic variable load
w1 = 0.33 x 4.00 x 3 = 3.96 kN/m
w2 = 0.47 x 4.00 x 3 = 5.64 kN/m
Qk = 9.60 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 38.16 kN/m
w = 1.35Gk = 23.76 kN/m

Output Ref Calculation

Beam 4C-D / 6C-D

Distribution of action from slab


One way slab FF = Ly/Lx 3000 / 2000 = 1.50 < 2
Action from slab
Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.44 x 6.50 x 3 = 8.58 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 18.38 kN/m
Characteristic variable load
w1 = 0.44 x 4.00 x 3 = 5.28 kN/m

Qk = 5.28 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 32.73 kN/m
w = 1.35Gk = 24.81 kN/m

Beam 5A-B

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2
One way slab
Action from slab
Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 6.50 x 2 = 4.68 kN/m
w2 = 0.36 x 6.50 x 2 = 4.68 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 19.16 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 2 = 2.88 kN/m
w2 = 0.36 x 4.00 x 2 = 2.88 kN/m
Qk = 5.76 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 34.51 kN/m
w = 1.35Gk = 25.87 kN/m

Output Ref Calculation


Beam 5B-C

Distribution of action from slab


One way slab FF = Ly/Lx 3000 / 3000 = 1.00 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.33 x 6.50 x 3 = 6.44 kN/m
w2 = 0.33 x 6.50 x 3 = 6.44 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 22.67 kN/m
Characteristic variable load
w1 = 0.33 x 4.00 x 3 = 3.96 kN/m
w2 = 0.33 x 4.00 x 3 = 3.96 kN/m
Qk = 7.92 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 42.48 kN/m
w = 1.35Gk = 30.60 kN/m

Beam 5C-D

Distribution of action from slab


One way slab FF = Ly/Lx 5000 / 3000 = 1.67 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.44 x 6.50 x 3 = 8.58 kN/m
w2 = 0.44 x 6.50 x 3 = 8.58 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 26.96 kN/m
Characteristic variable load
w1 = 0.44 x 4.00 x 3 = 5.28 kN/m
w2 = 0.44 x 4.00 x 3 = 5.28 kN/m
Qk = 10.56 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 52.24 kN/m
w = 1.35Gk = 36.40 kN/m
Output

Two way slab

Two way slab


Output

Two way slab

One way slab


Output

Two way slab

Two way slab


Output

Two way slab


Two way slab

Output

Two way slab


Two way slab

Output

Two way slab


Two way slab

Output

Two way slab


Two way slab

Output
Two way slab

Two way slab


Ref Calculation Output

Specification

GROUND

Characteristic Action:
Parmenent, gk = 1.5 kN/m (Excluding Selfweight)
Variable, qk = 4 kN/m
Design Life = 50 Years
Fire Resistance = 1 Hour
Exposure Class = XC3
Materials:
Characteristic strength of concrete, fck = 25 N/mm
Characteristic strength of steel, fyk = 500 N/mm
Unit weight of concrete = 25 kN/m
Weight of brickwork = 2.6 kN/m
Wallheight = 3m

SLAB THICKNESS
Estimated thickness considering deflection control, Try
h = 5000 / 25 = 200.00 mm 200
BEAM SIZE Try
Overall depth, h = L/13 = 5000 / 13 = 384.62 mm 400
Width, b = 0.4h = 0.4 x 384.62 = 153.85 mm 200
Use: b x h
200 x 400 mm

Ref Calculation Output

LOADING
Loads on slab

Selfweight = 0.20 x 25 = 5.00 kN/m


Finishing ceiling and service = 1.50 kN/m
Chac. Parmenent action, gk = 6.50 kN/m
Chac. Variable action, qk = 4.00 kN/m

Beam A1-2 / A8-9

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.35 x 6.50 x 2 = 4.55 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 14.35 kN/m
Characteristic variable load
w1 = 0.35 x 4.00 x 2 = 2.80 kN/m
Qk = 2.80 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 23.57 kN/m
w = 1.35Gk = 19.37 kN/m

Ref Calculation Output

Beam A2-3 / A3-4 / A6-7 / A7-8

Distribution of action from slab


FF = Ly/Lx 2000 / 2000 = 1.00 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.24 x 6.50 x 2 = 3.12 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 12.92 kN/m
Characteristic variable load
w1 = 0.24 x 4.00 x 2 = 1.92 kN/m
Qk = 1.92 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 20.32 kN/m
w = 1.35Gk = 17.44 kN/m

Beam A4-5 / A5-6

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.34 x 6.50 x 2 = 4.42 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 14.22 kN/m
Characteristic variable load
w1 = 0.34 x 1.50 x 2 = 1.02 kN/m
Qk = 1.02 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 20.73 kN/m
w = 1.35Gk = 19.20 kN/m

Ref Calculation Output

Beam B1-2 / B8-9

Distribution of action from slab


FF = Ly/Lx 3000 / 3000 = 1.00 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 6.50 x 3 = 7.02 kN/m
w2 = 0.54 x 6.50 x 2 = 7.02 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 23.84 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 3 = 4.32 kN/m
w2 = 0.54 x 4.00 x 2 = 4.32 kN/m
Qk = 8.64 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 45.14 kN/m
w = 1.35Gk = 32.18 kN/m
Beam B2-3 / B3-4 / B6-7 / B7-8

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.33 x 6.50 x 2 = 4.29 kN/m
w2 = 0.36 x 6.50 x 2 = 4.68 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 18.77 kN/m
Characteristic variable load
w1 = 0.33 x 4.00 x 2 = 2.64 kN/m
w2 = 0.36 x 4.00 x 2 = 2.88 kN/m
Qk = 5.52 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 33.62 kN/m
w = 1.35Gk = 25.34 kN/m

Ref Calculation Output

Beam B4-5 / B5-6

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.33 x 6.50 x 3 = 6.44 kN/m
w2 = 0.51 x 4.00 x 2 = 4.08 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 20.32 kN/m
Characteristic variable load
w1 = 0.33 x 4.00 x 3 = 3.96 kN/m
w2 = 0.51 x 4.00 x 2 = 4.08 kN/m
Qk = 8.04 kN/m
Total design load on beam
w = 1.35Gk + 1.5Qk = 39.49 kN/m
w = 1.35Gk = 27.43 kN/m

Beam C1-2 / C8-9

Distribution of action from slab


FF = Ly/Lx 5000 / 3000 = 1.67 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 6.50 x 3 = 7.02 kN/m
w2 = 0.36 x 6.50 x 3 = 7.02 kN/m
Gk = 16.04 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 3 = 4.32 kN/m
w2 = 0.36 x 4.00 x 3 = 4.32 kN/m
Qk = 8.64 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 34.61 kN/m
w = 1.35Gk = 21.65 kN/m

Ref Calculation Output

Beam C2-3 / C3-4 / C6-7 / C7-8

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2 One way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.33 x 6.50 x 2 = 4.29 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 14.09 kN/m
Characteristic variable load
w1 = 0.33 x 4.00 x 2 = 2.64 kN/m

Qk = 2.64 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 22.98 kN/m
w = 1.35Gk = 19.02 kN/m

Beam C4-5 / C5-6

Distribution of action from slab


FF = Ly/Lx 5000 / 3000 = 1.67 < 2 Two way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.33 x 6.50 x 3 = 6.44 kN/m
w2 = 0.33 x 6.50 x 3 = 6.44 kN/m
Gk = 14.87 kN/m
Characteristic variable load
w1 = 0.33 x 4.00 x 3 = 3.96 kN/m
w2 = 0.33 x 4.00 x 3 = 3.96 kN/m
Qk = 7.92 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 31.95 kN/m
w = 1.35Gk = 20.07 kN/m

Ref Calculation Output

Beam D1-2 / D8-9

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2 One way slab
Action from slab
Formula = v.n.lx
Characteristic parmenent load
wo 0.4 x 0.4 x 25 = 4 kN/m
w1 = 0.5 x 6.50 x 2 = 6.50 kN/m
w2 = 0.36 x 6.50 x 3 = 7.02 kN/m
Gk = 17.52 kN/m
Characteristic variable load
w1 = 0.5 x 4.00 x 2 = 4.00 kN/m
w2 = 0.36 x 4.00 x 3 = 4.32 kN/m
Qk = 8.32 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 36.13 kN/m
w = 1.35Gk = 23.65 kN/m

Beam D2-3 / D3-4 / D6-7 / D7-8

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2 One way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.5 x 6.50 x 2 = 6.50 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 16.30 kN/m
Characteristic variable load
w1 = 0.5 x 4.00 x 2 = 4.00 kN/m

Qk = 4.00 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 28.01 kN/m
w = 1.35Gk = 22.01 kN/m

Ref Calculation Output


Beam D4-5 / D5-6

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2 One way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.5 x 6.50 x 2 = 6.50 kN/m
w2 = 0.33 x 6.50 x 3 = 6.44 kN/m
Gk = 14.94 kN/m
Characteristic variable load
w1 = 0.5 x 4.00 x 2 = 4.00 kN/m
w2 = 0.33 x 4.00 x 3 = 3.96 kN/m
Qk = 7.96 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 32.10 kN/m
w = 1.35Gk = 20.16 kN/m

Beam E1-3 / E3-5 / E5-7 / E7-9

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2 One way slab

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.5 x 6.50 x 2 = 6.50 kN/m

Gk = 8.50 kN/m
Characteristic variable load
w1 = 0.5 x 4.00 x 2 = 4.00 kN/m
Qk = 4.00 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 17.48 kN/m
w = 1.35Gk = 11.48 kN/m
Output Ref Calculation

Beam 1A-B / 9A-B

Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.26 x 6.50 x 2 = 3.38 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 13.18 kN/m
Characteristic variable load
w1 = 0.26 x 4.00 x 2 = 2.08 kN/m
Qk = 2.08 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 20.91 kN/m
w = 1.35Gk = 17.79 kN/m

Beam 1B-C/ 9B-C

Distribution of action from slab


FF = Ly/Lx 3000 / 3000 = 1.00 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.24 x 6.50 x 3 = 4.68 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 14.48 kN/m
Characteristic variable load
w1 = 0.24 x 4.00 x 3 = 2.88 kN/m
Qk = 2.88 kN/m

mm Total design load on beam


w = 1.35Gk + 1.5Qk = 23.87 kN/m
w = 1.35Gk = 19.55 kN/m
mm
mm
Use: b x h
200 x 400 mm

Output Ref Calculation

Beam 1C-D / 9C-D

Distribution of action from slab


FF = Ly/Lx 5000 / 3000 = 1.67 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 6.50 x 5 = 11.70 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 21.50 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 5 = 7.20 kN/m
Qk = 7.20 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 39.83 kN/m
w = 1.35Gk = 29.03 kN/m

Beam 1D-E / 3D-E / 5D-E 7D-E / 9D-E

Distribution of action from slab


FF = Ly/Lx 5000 / 2000 = 2.50 > 2
Two way slab
Action from slab
Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m

Gk = 2.00 kN/m

Characteristic variable load


Qk = 0.00 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 2.70 kN/m
w = 1.35Gk = 2.70 kN/m

Output Ref Calculation

Beam 2A-B / 8A-B

Distribution of action from slab


Two way slab FF = Ly/Lx 2000 / 2000 = 1.00 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 6.50 x 2 = 4.68 kN/m
w2 = 0.4 x 6.50 x 2 = 5.20 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 19.68 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 2 = 2.88 kN/m
w2 = 0.4 x 4.00 x 2 = 3.20 kN/m
Qk = 6.08 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 35.69 kN/m
w = 1.35Gk = 26.57 kN/m

Beam 2B-C / 8B-C

Two way slab Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.45 x 6.50 x 2 = 5.85 kN/m
w2 = 0.36 x 6.50 x 2 = 4.68 kN/m
Gk = 12.53 kN/m
Characteristic variable load
w1 = 0.45 x 4.00 x 2 = 3.60 kN/m
w2 = 0.36 x 4.00 x 2 = 2.88 kN/m
Qk = 6.48 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 26.64 kN/m
w = 1.35Gk = 16.92 kN/m

Output Ref Calculation

Beam 2C-D / 8C-D

Distribution of action from slab


Two way slab FF = Ly/Lx 5000 / 3000 = 1.67 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.5 x 6.50 x 2 = 6.50 kN/m
w2 = 0.55 x 6.50 x 3 = 10.73 kN/m
Gk = 19.23 kN/m
Characteristic variable load
w1 = 0.44 x 4.00 x 2 = 3.52 kN/m
w2 = 0.55 x 4.00 x 3 = 6.60 kN/m
Qk = 10.12 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 41.13 kN/m
w = 1.35Gk = 25.95 kN/m

Beam 3A-B / 7A-B


Distribution of action from slab
FF = Ly/Lx 2000 / 2000 = 1.00 < 2
Two way slab
Action from slab
Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 6.50 x 2 = 4.68 kN/m
w2 = 0.36 x 6.50 x 2 = 4.68 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 19.16 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 2 = 2.88 kN/m
w2 = 0.36 x 4.00 x 2 = 2.88 kN/m
Qk = 5.76 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 34.51 kN/m
w = 1.35Gk = 25.87 kN/m

Output Ref Calculation

Beam 3B-C / 7B-C

Distribution of action from slab


Two way slab FF = Ly/Lx 3000 / 2000 = 1.50 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.45 x 6.50 x 2 = 5.85 kN/m
w2 = 0.45 x 6.50 x 2 = 5.85 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 21.50 kN/m
Characteristic variable load
w1 = 0.45 x 4.00 x 2 = 3.60 kN/m
w2 = 0.45 x 4.00 x 2 = 3.60 kN/m
Qk = 7.20 kN/m
Total design load on beam
w = 1.35Gk + 1.5Qk = 39.83 kN/m
w = 1.35Gk = 29.03 kN/m

Beam 3C-D / 7C-D

Two way slab Distribution of action from slab


FF = Ly/Lx 5000 / 3000 = 1.67 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.5 x 6.50 x 2 = 6.50 kN/m
w2 = 0.5 x 6.50 x 2 = 6.50 kN/m
Brickwall, w1 = 2.6 x 3.00 = 7.8 kN/m
Gk = 16.30 kN/m
Characteristic variable load
w1 = 0.5 x 4.00 x 2 = 4.00 kN/m
w2 = 0.5 x 4.00 x 2 = 4.00 kN/m
Qk = 0.00 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 22.01 kN/m
w = 1.35Gk = 22.01 kN/m

Output Ref Calculation

Beam 4A-B / 6A-B

Distribution of action from slab


One way slab FF = Ly/Lx 2000 / 2000 = 1.00 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 6.50 x 2 = 4.68 kN/m
w2 = 0.36 x 6.50 x 2 = 4.68 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 19.16 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 2 = 2.88 kN/m
w2 = 0.36 x 4.00 x 2 = 2.88 kN/m
Qk = 5.76 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 34.51 kN/m
w = 1.35Gk = 25.87 kN/m

Beam 4B-C / 6B-C


Two way slab
Distribution of action from slab
FF = Ly/Lx 3000 / 2000 = 1.50 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.33 x 6.50 x 3 = 6.44 kN/m
w2 = 0.45 x 6.50 x 3 = 8.78 kN/m
Gk = 17.21 kN/m
Characteristic variable load
w1 = 0.33 x 4.00 x 3 = 3.96 kN/m
w2 = 0.45 x 4.00 x 3 = 5.40 kN/m
Qk = 9.36 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 37.27 kN/m
w = 1.35Gk = 23.23 kN/m

Output Ref Calculation

Beam 4C-D / 6C-D

Distribution of action from slab


One way slab FF = Ly/Lx 3000 / 2000 = 1.50 < 2
Action from slab
Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.48 x 6.50 x 3 = 9.36 kN/m
w2 = 0.5 x 6.50 x 2 = 6.50 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 19.16 kN/m
Characteristic variable load
w1 = 0.48 x 4.00 x 3 = 5.76 kN/m
w2 = 0.5 x 4.00 x 2 = 4.00 kN/m
Qk = 9.76 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 40.51 kN/m
w = 1.35Gk = 25.87 kN/m

Beam 5A-B

One way slab Distribution of action from slab


FF = Ly/Lx 3000 / 2000 = 1.50 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.36 x 6.50 x 2 = 4.68 kN/m
w2 = 0.36 x 6.50 x 2 = 4.68 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 19.16 kN/m
Characteristic variable load
w1 = 0.36 x 4.00 x 2 = 2.88 kN/m
w2 = 0.36 x 4.00 x 2 = 2.88 kN/m
Qk = 5.76 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 34.51 kN/m
w = 1.35Gk = 25.87 kN/m

Output Ref Calculation


Beam 5B-C

Distribution of action from slab


One way slab FF = Ly/Lx 3000 / 3000 = 1.00 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.33 x 6.50 x 3 = 6.44 kN/m
w2 = 0.33 x 6.50 x 3 = 6.44 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 22.67 kN/m
Characteristic variable load
w1 = 0.33 x 4.00 x 3 = 3.96 kN/m
w2 = 0.33 x 4.00 x 3 = 3.96 kN/m
Qk = 7.92 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 42.48 kN/m
w = 1.35Gk = 30.60 kN/m

Beam 5C-D

Distribution of action from slab


One way slab FF = Ly/Lx 5000 / 3000 = 1.67 < 2

Action from slab


Formula = v.n.lx
Characteristic parmenent load
wo 0.2 x 0.4 x 25 = 2 kN/m
w1 = 0.48 x 6.50 x 3 = 9.36 kN/m
w2 = 0.48 x 6.50 x 3 = 9.36 kN/m
Brickwall, w3 = 2.6 x 3.00 = 7.8 kN/m
Gk = 28.52 kN/m
Characteristic variable load
w1 = 0.48 x 4.00 x 3 = 5.76 kN/m
w2 = 0.48 x 4.00 x 3 = 5.76 kN/m
Qk = 11.52 kN/m

Total design load on beam


w = 1.35Gk + 1.5Qk = 55.78 kN/m
w = 1.35Gk = 38.50 kN/m
Output

Two way slab

Two way slab


Output

Two way slab

One way slab


Output

Two way slab

Two way slab


Output

Two way slab


Two way slab

Output

Two way slab


Two way slab

Output

Two way slab


Two way slab

Output

Two way slab


Two way slab

Output
Two way slab

Two way slab

You might also like