You are on page 1of 5

Legal Statement Year 2002/2003 releases

(c) 2002/2003 www.pveng.com www.pveng.com

Terms
This software is the property of Pressure Vessel Engineering Ltd (www.pveng.com).
If you use this product you agree to the following terms and conditions:
1 This program is the property of www.pveng.com
2 This program is not available for sale under any circumstances.
The user uses this software at their own risk.
3 This notice must be included with all copies made.
4 This product is used "as is" without warrantees or liability. It is your responsibility
to know how to use this software. Any product designed with this software
is your responsibility. www.pveng.com does not guarantee the accuracy of this product.
All risk associated with this products use is assumed by the user.
5 www.pveng.com does not provide support for the use of this product
6 The codes and standards that this product is based on change periodically. It
is your responsibility to check that you are using an appropriate version.
7 This program is not a substitute for knowing the applicable codes and standards.
8 It is your job to ensure that you are using the most up-to-date version of this software
9 There is no guarantee that future versions of this program will be made available.

Locked Cells
This spreadsheet is locked for your convenience. You can move between input
cells using the Tab key. The password to unlock it is "100". If you make changes
to this spreadsheet you are required to remove the "www.pveng.com"
hyperlink. You are responsible for any and all changes that you make.

Comments
If you have comment, corrections or questions about this product send an email
to lb@pveng.com. I am sorry, but I do not answer all emails.
lb@pveng.com

Printing and Excel/Windows Russian Roulette


A Printing macro is provided with this spreadsheet. Press Ctrl+p to print the calculations.
The macro checks for a dangerous error condition where Excel allows input values
to be changed but does not recalculate the outputs. If this occurs, an error
message will pop up instead of printing. Your computer has run out of resources and must be restarted.
This protection is only available if you use the print macro. Use Windows NT/2000 to get more
Windows systems resources. Quit playing Russian Roulette - Do not use Windows 95/98/ME for
any type of engineering work.

Verification
This program was verified in one of the following ways
1 comparing it with an ASME code book examples - most examples are found in App. L
2 Hand calculations
3 Comparison with other commercial software
4 two or more of the above methods
Although every effort was made to make this software accurate and easy to understand, there
is no way to guarantee that it is accurate.

Registration
This program can not be registered. It remains the property of www.pveng.com

#NAME? <- Useful page 2 formula


#NAME? <- Useful page 3 formula
#NAME? <- Useful page 4 formula
50 ASME Sample L-2.3.3 Verification Calculation #1 7-Dec-17 Page 2 of 2
51

52 Conical Section UG-32(g)


53

54 tc = ThickB - corrosion = 0.625 - 0 tc = 0.625


55

56 PDi 1000 * 199.732


57 tMin = ---------------- = ---------------------------------------------- tMin = 11.046
58 2cos(a)*(SE-0.6P) 2 * cos(0.524)*(13800*0.8-0.6*1000) ERROR
59

60 2SEtcCos(a) 2 * 13800 * 0.8 * 0.625 * Cos(0.524)


61 PMax = ---------------- = ---------------------------------------------- PMax = 60
62 D + 1.2*tc*cos(a) 199.732 + 1.2 * 0.625 * cos(0.524) ERROR
63

64 Opening In Cone - Required Thickness, E=1 UG-32(g)


65

66 30.000 <- Dd Diameter of cone at opening


67 for reinforcement
68 PDd 1000 * 30 calculations only!
69 tatOpening = ---------------- = ---------------------------------------------- tatOpening = 1.312
70 2cos(a)*(SE-0.6P) 2 * cos(0.524)*(13800*1-0.6*1000)
71

72 Head stress relief (UCS-79 (d) - carbon and low alloy steel only)
73

74 Yes <- Head is cold formed(Yes/no)


75 100.0% <- Fiber elongation > 5% ? Required Yes ?
76 no <- Vessel carries lethal substances(Yes/no) no no
77 no <- Impact testing is required (Yes/no) no no
78 no <- Formed between 250 and 900 Degrees F no no
79 no <- Greater than 10% reduction in thickness no no
80 no <- Head is greater than 5/8" thick before forming no no
81 Stress Relieve ? no
82

83

84
Head - Internally Pressurized

Written By: Laurence Brundrett

Code: ASME VIII div 1


Addenda: A2000
Sections: UG-32, App 1-4(d), UCS 79 (d), UG-37 1(a)

Update Log

Date Change
1-Jan-99 Program Written
16-May-99 Added Audit Sheet
Check Spelling
Moved Factor M and Volume calculations onto separate sheets
Checked Against L-1.5.2(g) - Sample Calculations
7-Oct-99 Updated Graphics to A99 Standard
9-Oct-99 Re-arranged contents to make page 2 optional
Added Maximum working pressure
Volume Calculations Checked
Added Stress Meter
Set Sample Values
Checked Against A99 Update
Locked Cells
10-Oct-99 Added print protection macro
12-Jan-00 Modified print protection macro
1-Jun-00 Hand Calculate Results
Refer to verification calculations
Changed Fr to mid radius (was set to ID)
Added Commentary
Cells Locked
8-Aug-00 Copied from F&D head spreadsheet
Removed M factor and drawing section
Changed Commentary
Changed Calculation sheet and Volume Sheet Formulas
9-Aug-00 Hand verification calculation - sample from ASME VIII L-2.3.3
Cells Locked - Pasword = "100"
Volume calculation has not been verified
2-Oct-00 Changed to A2000 Format
A2000 print macro
A2000 Legal Statement
All Calculations on one page suitable for moving and renaming tabs
Version number assigned = Ver 1.1
Thickness for reinforcment changed to required thickness at E=1
Cells Locked - Password = "100"
24-Oct-00 Fiber elongation set to 100%
Rf calculations removed