design of Prestressed Girder

concrete 23.54
wearing course 1.05
f'c (pc) 34.5
f'ci 27.6
f'c 21
Ec 21538.106
Ec(pc) 27606.249
Ec(i) 24691.78
fr 3.6416754

prestressing steel
fsu 1862
Ep 193000
fpy 1582.70
u 0.25
k 0.00492

allowable stress
at transfer stage
f'c(ct) 15.18
f'c(tt) 3.26
at service stage
f'c(cs) 2.35
f'c(ts) 2.94

superstructure data
slab thickness 0.2
haunch thickness 0.05
girder spacing 2.2
no. of girder 4
rw 6.6
span 23
lanes 2

girder basic properties


Type IV
area 0.509
moment of inertia 0.108511
Yt 0.743
Yb 0.6281
section modulus (top) 0.1460444
section modulus (bottom) 0.1727607
width of top flange 0.508
width of bottom flange 0.666

b(eff) 2.2

moment of inertia (total)


area Y AY AYY I(o)
slab 0.44 1.5211 0.669284 1.018048 0.001467
haunch 0.0254 1.3961 0.0354609 0.049507 5.29E-06
girder 0.509 0.6281 0.3197029 0.200805 0.108511
total 0.9744 1.0244478 1.26836 0.109983

Iz 1.378343
Y' 1.051363
I 1.509307

Yt 0.555152
Yb 1.065948

Stg 4.310433
Sbg 1.415929