You are on page 1of 19

BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE STRUCTURE: STUB

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010

LENGTH UNIT WT. PC. WT.


MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)

NMA 1 HT 150x150x12 4104 27.30 112.04 3 336.12


NMA 1E HT 150x150x12 4104 27.30 112.04 1 112.04
NMA 2 L90x90x6 300 8.20 2.46 12 29.52
NMA 2X L90x90x6 300 8.20 2.46 12 29.52
NMA 2Y L130x130x10 500 19.70 9.85 4 39.40

TOTAL= 546.60 KGS


BOLTS & NUTS
M16x45 DIA BOLT 0.140 96 13.44
M16x50 DIA BOLT 0.148 32 4.74

3.5 THK SPRING WASHER 0.009 128 1.15


TOTAL= 19.33

GRAND TOTAL= 565.92

Page 1 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE STRUCTURE: TEMPLATE

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)

NMA 01 L80x80x6 1172 7.30 8.56 4 34.22


NMA 02 L75x75x5 4500 5.70 25.65 4 102.60
NMA 03 L75x75x5 1965 5.70 11.20 4 44.80
NMA 04 L75x75x5 2885 5.70 16.44 4 65.78
NMA 05 L75x75x5 3702 5.70 21.10 4 84.41
NMA 06 L65x65x5 256 4.90 1.25 8 10.04
NMA 07 L45x45x4 1062 2.70 2.87 32 91.76
NMA 08 L45x45x4 999 2.70 2.70 8 21.58
NMA 09 L45x45x4 938 2.70 2.53 4 10.13
NMA 010 L45x45x4 1231 2.70 3.32 4 13.29
NMA 010 X L45x45x4 1231 2.70 3.32 4 13.29
NMA 011 L50x50x5 2974 3.80 11.30 4 45.20
NMA 012 L50x50x5 2974 3.80 11.30 4 45.20
NMA 013 L50x50x5 3044 3.80 11.57 4 46.27
NMA 014 L50x50x5 3044 3.80 11.57 4 46.27

TOTAL: 674.85 KGS

BOLTS & NUTS


M16x35 DIA BOLT 0.124 28 3.47
M16x40 DIA BOLT 0.132 124 16.37
M16x45 DIA BOLT 0.140 24 3.36

3.5 THK SPRING WASHER 0.009 176 1.58

TOTAL 24.78 KGS

GRAND TOTAL= 699.63 KGS

Page 2 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE SUPER STRUCTURE

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)

NMA 3 HT 150x150x12 4460 27.30 121.76 3 365.28


NMA 3 S HT 150x150x12 4460 27.30 121.76 1 121.76
NMA 4 HT 130x130x10 456 19.70 8.98 12 107.76
NMA 5 8MM PLATE 120x456 62.80 3.44 24 82.56
NMA 6 L75x75x5 4000 5.70 22.80 4 91.20
NMA 6 A L75x75x5 4000 5.70 22.80 4 91.20
NMA 7 L75x75x5 2937 5.70 16.74 4 66.96
NMA 7 A L75x75x5 2937 5.70 16.74 4 66.96
NMA 8 L45x45x4 1277 2.70 3.45 8 27.60
NMA 9 L50x50x5 1615 3.80 6.14 8 49.12
NMA 10 L65x65x5 2576 4.90 12.62 8 100.96
NMA 11 L50x50x5 1714 3.80 6.51 6 39.06
NMA 11 X L50x50x5 1714 3.80 6.51 2 13.02
NMA 12 L45x45x4 1277 2.70 3.45 6 20.70
NMA 12 A L45x45x4 1277 2.70 3.45 2 6.90
NMA 13 HT 150x150x12 3540 27.30 96.64 3 289.92
NMA 13 S HT 150x150x12 3540 27.30 96.64 1 96.64
NMA 14 L75x75x5 5673 5.70 32.34 4 129.36
NMA 14 A L75x75x5 5673 5.70 32.34 4 129.36
NMA 15 L45x45x4 1123 2.70 3.03 8 24.24
NMA 16 L45x45x4 1354 2.70 3.66 8 29.28
NMA 17 L60x60x5 2286 4.50 10.29 8 82.32
NMA 18 L45x45x4 1461 2.70 3.94 8 31.52
NMA 19 L45x45x4 1123 2.70 3.03 8 24.24
NMA 20 HT 150x150x12 5300 27.30 144.69 3 434.07
NMA 20 S HT 150x150x12 5300 27.30 144.69 1 144.69
NMA 21 L75x75x5 4844 5.70 27.61 4 110.44
NMA 21 A L75x75x5 4844 5.70 27.61 4 110.44
NMA 22 L45x45x4 929 2.70 2.51 8 20.08
NMA 23 L45x45x4 1484 2.70 4.01 4 16.04
NMA 23 X L45x45x4 1484 2.70 4.01 4 16.04
NMA 24 L45x45x4 1509 2.70 4.07 8 32.56
NMA 25 L45x45x4 1033 2.70 2.79 4 11.16
NMA 25 X L45x45x4 1033 2.70 2.79 4 11.16
NMA 26 L60x60x5 4167 4.50 18.75 4 75.00
NMA 26 A L60x60x5 4167 4.50 18.75 4 75.00

Page 3 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE SUPER STRUCTURE

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)
NMA 27 L45x45x4 1001 2.70 2.70 4 10.80
NMA 27 X L45x45x4 1001 2.70 2.70 4 10.80
NMA 28 L45x45x4 1207 2.70 3.26 8 26.08
NMA 29 L45x45x4 1108 2.70 2.99 4 11.96
NMA 29 X L45x45x4 1108 2.70 2.99 4 11.96
NMA 30 HT 130x130x12 4315 23.50 101.40 1 101.40
NMA 30 S HT 130x130x12 4315 23.50 101.40 1 101.40
NMA 30 A HT 130x130x12 4315 23.50 101.40 2 202.80
NMA 31 HT 130x130x10 456 19.70 8.98 4 35.92
NMA 32 8MM PLATE 120x456 62.80 3.44 8 27.52
NMA 33 L60x60x5 3857 4.50 17.36 2 34.72
NMA 33 A L60x60x5 3857 4.50 17.36 2 34.72
NMA 34 L45x45x4 945 2.70 2.55 2 5.10
NMA 34 X L45x45x4 945 2.70 2.55 2 5.10
NMA 35 L45x45x4 1182 2.70 3.19 4 12.76
NMA 35 A L45x45x4 1137 2.70 3.07 4 12.28
NMA 36 L45x45x4 1020 2.70 2.75 2 5.50
NMA 36 X L45x45x4 1020 2.70 2.75 2 5.50
NMA 37 L60x60x5 3810 4.50 17.15 2 34.30
NMA 37 A L60x60x5 3810 4.50 17.15 2 34.30
NMA 38 L45x45x4 921 2.70 2.49 2 4.98
NMA 38 X L45x45x4 921 2.70 2.49 2 4.98
NMA 39 L45x45x4 1022 2.70 2.76 2 5.52
NMA 39 X L45x45x4 1022 2.70 2.76 2 5.52
NMA 40 L 8MM PLATE 165x390 62.80 4.04 2 8.08
NMA 40 R 8MM PLATE 165x390 62.80 4.04 2 8.08
NMA 41 L75x75x5 2937 5.70 16.74 2 33.48
NMA 42 L75x75x5 3540 5.70 20.18 2 40.36
NMA 42 A L75x75x5 3540 5.70 20.18 2 40.36
NMA 43 6MM PLATE 97x280 47.10 1.28 2 2.56
NMA 44 L50x50x5 1453 3.80 5.52 4 22.08
NMA 45 6MM PLATE 150x245 47.10 1.73 4 6.92
NMA 46 L 8MM PLATE 175x394 62.80 4.33 2 8.66
NMA 46 R 8MM PLATE 175x394 62.80 4.33 2 8.66
NMA 47 L80x80x6 3146 7.30 22.97 2 45.94
NMA 48 L65x65x5 3587 4.90 17.58 2 35.16
NMA 48 A L65x65x5 3587 4.90 17.58 2 35.16

Page 4 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE SUPER STRUCTURE

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)
NMA 49 L50x50x5 1533 3.80 5.83 2 11.66
NMA 49 X L50x50x5 1533 3.80 5.83 2 11.66
NMA 50 HT 130x130x10 5186 19.70 102.16 1 102.16
NMA 50 S HT 130x130x10 5186 19.70 102.16 1 102.16
NMA 50 A HT 130x130x10 5186 19.70 102.16 2 204.32
NMA 51 HT 130x130x10 386 19.70 7.60 4 30.40
NMA 52 8MM PLATE 105x386 62.80 2.55 8 20.40
NMA 53 2MM PLATE 95x190 15.70 0.28 8 2.24
NMA 54 L75x75x6 3986 6.80 27.10 2 54.20
NMA 54 A L75x75x6 3986 6.80 27.10 2 54.20
NMA 55 L45x45x4 682 2.70 1.84 4 7.36
NMA 56 L45x45x4 973 2.70 2.63 2 5.26
NMA 56 X L45x45x4 973 2.70 2.63 2 5.26
NMA 57 HT 45x45x4 1338 2.70 3.61 4 14.44
NMA 58 L45x45x4 1012 2.70 2.73 2 5.46
NMA 58 X L45x45x4 1012 2.70 2.73 2 5.46
NMA 59 L45x45x4 682 2.70 1.84 4 7.36
NMA 60 L65x65x5 3938 4.90 19.30 2 38.60
NMA 60 A L65x65x5 3938 4.90 19.30 2 38.60
NMA 61 L45x45x4 667 2.70 1.80 4 7.20
NMA 62 L45x45x4 963 2.70 2.60 2 5.20
NMA 62 X L45x45x4 963 2.70 2.60 2 5.20
NMA 63 HT 45x45x4 1339 2.70 3.62 4 14.48
NMA 64 L45x45x4 1002 2.70 2.71 2 5.42
NMA 64 X L45x45x4 1002 2.70 2.71 2 5.42
NMA 65 L45x45x4 668 2.70 1.80 4 7.20
NMA 66 6MM PLATE 150x415 47.10 2.93 4 11.72
NMA 67 L70x70x5 2571 5.30 13.63 2 27.26
NMA 68 L70x70x5 3258 5.30 17.27 2 34.54
NMA 68 A L70x70x5 3258 5.30 17.27 2 34.54
NMA 69 6MM PLATE 95x260 47.10 1.16 2 2.32
NMA 70 L50x50x5 1269 3.80 4.82 4 19.28
NMA 71 6MM PLATE 150x267 47.10 1.89 4 7.56
NMA 72 6MM PLATE 157x235 47.10 1.74 4 6.96
NMA 73 L60x60x5 2775 4.50 12.49 2 24.98
NMA 74 L60x60x5 3308 4.50 14.89 2 29.78
NMA 74 A L60x60x5 3308 4.50 14.89 2 29.78

Page 5 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE SUPER STRUCTURE

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)
NMA 75 L50x50x5 1339 3.80 5.09 4 20.36
NMA 76 6MM PLATE 150x186 47.10 1.31 4 5.24
NMA 77 HT100x100x10 5100 14.90 75.99 1 75.99
NMA 77 S HT100x100x10 5100 14.90 75.99 1 75.99
NMA 77 A HT100x100x10 5100 14.90 75.99 2 151.98
NMA 78 HT100x100x10 316 14.90 4.71 8 37.68
NMA 79 8MM PLATE 93x316 62.80 1.85 16 29.60
NMA 80 HT 70x70x5 3749 5.30 19.87 2 39.74
NMA 80 A HT 70x70x5 3749 5.30 19.87 2 39.74
NMA 81 L45x45x4 610 2.70 1.65 8 13.20
NMA 82 L45x45x4 925 2.70 2.50 2 5.00
NMA 82 X L45x45x4 925 2.70 2.50 2 5.00
NMA 83 L45x45x4 1175 2.70 3.17 8 25.36
NMA 84 L45x45x4 958 2.70 2.59 2 5.18
NMA 84 X L45x45x4 958 2.70 2.59 2 5.18
NMA 85 L45x45x4 603 2.70 1.63 8 13.04
NMA 86 L60x60x5 3715 4.50 16.72 2 33.44
NMA 86 A L60x60x5 3715 4.50 16.72 2 33.44
NMA 87 L45x45x4 912 2.70 2.46 2 4.92
NMA 87 X L45x45x4 912 2.70 2.46 2 4.92
NMA 88 L45x45x4 950 2.70 2.57 2 5.14
NMA 88 X L45x45x4 950 2.70 2.57 2 5.14
NMA 89 6MM PLATE 192x249 47.10 2.25 4 9.00
NMA 90 HT 70x70x5 2194 5.30 11.63 2 23.26
NMA 91 L65x65x5 3012 4.90 14.76 2 29.52
NMA 91 A L65x65x5 3012 4.90 14.76 2 29.52
NMA 92 6MM PLATE 99x230 47.10 1.07 2 2.14
NMA 93 L50x50x5 1081 3.80 4.11 4 16.44
NMA 94 6MM PLATE 133x263 47.10 1.65 4 6.60
NMA 95 6MM PLATE 139x227 47.10 1.49 4 5.96
NMA 96 HT 60x60x5 2409 4.50 10.84 2 21.68
NMA 97 L60x60x5 3066 4.50 13.8 2 27.60
NMA 97 A L60x60x5 3066 4.50 13.8 2 27.60
NMA 98 L50x50x5 1141 3.80 4.34 4 17.36
NMA 99 6MM PLATE 100x117 47.10 0.55 4 2.20
NMA 100 HT100x100x10 3300 14.90 49.17 1 49.17
NMA 100 S HT100x100x10 3300 14.90 49.17 1 49.17

Page 6 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE SUPER STRUCTURE

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)
NMA 100 A HT100x100x10 3300 14.90 49.17 2 98.34
NMA 101 L75x75x5 3551 5.70 20.24 2 40.48
NMA 101 A L75x75x5 3551 5.70 20.24 2 40.48
NMA 102 L45x45x4 512 2.70 1.38 8 11.04
NMA 103 L45x45x4 880 2.70 2.38 2 4.76
NMA 103 X L45x45x4 880 2.70 2.38 2 4.76
NMA 104 L45x45x4 992 2.70 2.68 8 21.44
NMA 105 L45x45x4 896 2.70 2.42 2 4.84
NMA 105 X L45x45x4 896 2.70 2.42 2 4.84
NMA 106 L45x45x4 512 2.70 1.38 8 11.04
NMA 107 L65x65x5 3502 4.90 17.16 2 34.32
NMA 107 A L65x65x5 3502 4.90 17.16 2 34.32
NMA 108 L45x45x4 866 2.70 2.34 2 4.68
NMA 108 X L45x45x4 866 2.70 2.34 2 4.68
NMA 109 L45x45x4 885 2.70 2.39 2 4.78
NMA 109 X L45x45x4 885 2.70 2.39 2 4.78
NMA 110 L 6MM PLATE 190x256 47.10 2.29 2 4.58
NMA 110 R 6MM PLATE 190x256 47.10 2.29 2 4.58
NMA 111 HT 60x60x5 1829 4.50 8.23 2 16.46
NMA 112 6MM PLATE 140x244 47.10 1.61 4 6.44
NMA 113 HT 60x60x5 2042 4.50 9.19 2 18.38
NMA 114 HT 90x90x8 5300 10.80 57.24 1 57.24
NMA 114 S HT 90x90x8 5300 10.80 57.24 1 57.24
NMA 114 A HT 90x90x8 5300 10.80 57.24 2 114.48
NMA 115 L65x65x5 2783 4.90 13.64 2 27.28
NMA 115 A L65x65x5 2783 4.90 13.64 2 27.28
NMA 116 L50x50x5 922 3.80 3.50 4 14.00
NMA 117 6MM PLATE 117x215 47.10 1.18 4 4.72
NMA 118 L65x65x5 2833 4.90 13.88 2 27.76
NMA 118 A L65x65x5 2833 4.90 13.88 2 27.76
NMA 119 L50x50x5 922 3.80 3.50 4 14.00
NMA 120 6MM PLATE 117x215 47.10 1.18 4 4.72
NMA 121 L60x60x5 2321 4.50 10.44 2 20.88
NMA 121 A L60x60x5 2321 4.50 10.44 2 20.88
NMA 122 6MM PLATE 117x190 47.10 1.05 4 4.20
NMA 123 L60x60x5 2320 4.50 10.44 2 20.88
NMA 123 A L60x60x5 2320 4.50 10.44 2 20.88

Page 7 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE SUPER STRUCTURE

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)
NMA 124 6MM PLATE 117x200 47.10 1.10 4 4.40
NMA 125 L60x60x5 2166 4.50 9.75 2 19.50
NMA 125 A L60x60x5 2166 4.50 9.75 2 19.50
NMA 126 6MM PLATE 170x210 47.10 1.68 4 6.72
NMA 127 L65x65x5 1656 4.90 8.11 2 16.22
NMA 128 6MM PLATE 117x150 47.10 0.83 4 3.32
NMA 129 L60x60x5 2136 4.50 9.61 2 19.22
NMA 129 A L60x60x5 2136 4.50 9.61 2 19.22
NMA 130 6MM PLATE 119x190 47.10 1.06 4 4.24
NMA 131 L50x50x5 1846 3.80 7.01 2 14.02
NMA 132 6MM PLATE 117x155 47.10 0.85 4 3.40
NMA 133 HT75x75x6 3900 6.80 26.52 1 26.52
NMA 133 S HT75x75x6 3900 6.80 26.52 1 26.52
NMA 133 A HT75x75x6 3900 6.80 26.52 2 53.04
NMA 134 L60x60x5 2663 4.50 11.98 2 23.96
NMA 134 A L60x60x5 2663 4.50 11.98 2 23.96
NMA 135 L50x50x5 833 3.80 3.17 4 12.68
NMA 136 6MM PLATE 110x215 47.10 1.11 4 4.44
NMA 137 L65x65x5 2710 4.90 13.28 2 26.56
NMA 137 A L65x65x5 2710 4.90 13.28 2 26.56
NMA 138 L50x50x5 834 3.80 3.17 4 12.68
NMA 139 6MM PLATE 110x225 47.10 1.17 4 4.68
NMA 140 L60x60x5 2176 4.50 9.79 2 19.58
NMA 140 A L60x60x5 2176 4.50 9.79 2 19.58
NMA 141 6MM PLATE 110x205 47.10 1.06 4 4.24
NMA 142 L60x60x5 2176 4.50 9.79 2 19.58
NMA 142 A L60x60x5 2176 4.50 9.79 2 19.58
NMA 143 6MM PLATE 110x210 47.10 1.09 4 4.36
NMA 144 HT75x75x6 2640 6.80 17.95 1 17.95
NMA 144 S HT75x75x6 2640 6.80 17.95 1 17.95
NMA 144 A HT75x75x6 2640 6.80 17.95 2 35.90
NMA 145 L60x60x5 2032 4.50 9.14 2 18.28
NMA 145 A L60x60x5 2032 4.50 9.14 2 18.28
NMA 146 6MM PLATE 162x211 47.10 1.61 4 6.44
NMA 147 L60x60x5 1470 4.50 6.62 2 13.24
NMA 148 L60x60x5 1994 4.50 8.97 2 17.94
NMA 148 A L60x60x5 1994 4.50 8.97 2 17.94

Page 8 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE SUPER STRUCTURE

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)
NMA 149 6MM PLATE 112x195 47.10 1.03 4 4.12
NMA 150 L50x50x5 1652 3.80 6.28 2 12.56
NMA 151 6MM PLATE 110x115 47.10 0.60 4 2.40
NMA 152 L50x50x5 1732 3.80 6.58 2 13.16
NMA 152 A L50x50x5 1732 3.80 6.58 2 13.16
NMA 153 6MM PLATE 110x115 47.10 0.60 4 2.40
NMA 154 L50x50x5 1764 3.80 6.70 2 13.40
NMA 154 A L50x50x5 1764 3.80 6.70 2 13.40
NMA 155 6MM PLATE 110x156 47.10 0.81 4 3.24
NMA 156 L50x50x5 1470 3.80 5.59 4 22.36
NMA 157 HT 65x65x5 3991 4.90 19.56 1 19.56
NMA 157 S HT 65x65x5 3991 4.90 19.56 1 19.56
NMA 157 A HT 65x65x5 3991 4.90 19.56 2 39.12
NMA 158 L45x45x4 1786 2.70 4.82 4 19.28
NMA 159 L45x45x4 1023 2.70 2.76 4 11.04
NMA 160 L45x45x4 1524 2.70 4.11 4 16.44
NMA 161 L45x45x4 577 2.70 1.56 4 6.24
NMA 162 6MM PLATE 109x177 47.10 0.91 2 1.82
NMA 163 6MM PLATE 168x422 47.10 3.34 1 3.34
NMA 164 HT 60x60x5 4084 4.50 18.38 2 36.76
NMA 165 HT 60x60x5 4084 4.50 18.38 2 36.76
NMA 166 HT 50x50x5 3770 3.80 14.33 2 28.66
NMA 167 HT 50x50x5 3770 3.80 14.33 2 28.66
NMA 168 6MM PLATE 150x344 47.10 2.43 2 4.86
NMA 169 L45x45x4 447 2.70 1.21 4 4.84
NMA 170 L45x45x4 1357 2.70 3.66 2 7.32
NMA 170 X L45x45x4 1357 2.70 3.66 2 7.32
NMA 171 L45x45x4 809 2.70 2.18 2 4.36
NMA 171 X L45x45x4 809 2.70 2.18 2 4.36
NMA 172 L45x45x4 1398 2.70 3.77 2 7.54
NMA 172 X L45x45x4 1398 2.70 3.77 2 7.54
NMA 173 8MM PLATE 120x256 62.80 1.93 2 3.86
NMA 173 X 8MM PLATE 120x256 62.80 1.93 2 3.86
NMA 174 HT 45x45x4 200 2.70 0.54 2 1.08
NMA 175 L45x45x4 1094 2.70 2.95 2 5.90
NMA 176 HT 45x45x5 1950 3.40 6.63 2 13.26
NMA 177 HT 45x45x5 2081 3.40 7.08 2 14.16

Page 9 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE SUPER STRUCTURE

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)
NMA 178 L60x60x5 3966 4.50 17.85 1 17.85
NMA 178 A L60x60x5 3966 4.50 17.85 1 17.85
NMA 179 L65x65x5 2794 4.90 13.69 2 27.38
NMA 180 HT 45x45x5 2140 3.40 7.28 2 14.56
NMA 181 HT 45x45x5 1967 3.40 6.69 2 13.38
NMA 182 L45x45x4 1136 2.70 3.07 2 6.14
NMA 183 6MM PLATE 120x126 47.10 0.71 12 8.52
NMA 184 L90x90x6 126 8.20 1.03 12 12.36
NMA 185 L90x90x6 263 8.20 2.16 2 4.32
NMA 186 HT 60x60x5 3964 4.50 17.84 2 35.68
NMA 187 HT 60x60x5 3964 4.50 17.84 2 35.68
NMA 188 HT 50x50x5 3658 3.80 13.90 2 27.80
NMA 189 HT 50x50x5 3658 3.80 13.90 2 27.80
NMA 190 6MM PLATE 150x344 47.10 2.43 2 4.86
NMA 191 L45x45x4 428 2.70 1.16 4 4.64
NMA 192 L45x45x4 1289 2.70 3.48 2 6.96
NMA 192 X L45x45x4 1289 2.70 3.48 2 6.96
NMA 193 L45x45x4 785 2.70 2.12 2 4.24
NMA 193 X L45x45x4 785 2.70 2.12 2 4.24
NMA 194 L45x45x4 1422 2.70 3.84 2 7.68
NMA 194 X L45x45x4 1422 2.70 3.84 2 7.68
NMA 195 8MM PLATE 120x257 62.80 1.94 2 3.88
NMA 195 X 8MM PLATE 120x257 62.80 1.94 2 3.88
NMA 196 HT 45x45x4 200 2.70 0.54 2 1.08
NMA 197 L45x45x4 863 2.70 2.33 2 4.66
NMA 198 HT 45x45x4 1731 2.70 4.67 2 9.34
NMA 199 HT 45x45x4 1736 2.70 4.69 2 9.38
NMA 200 L50x50x5 3386 3.80 12.87 1 12.87
NMA 200 A L50x50x5 3386 3.80 12.87 1 12.87
NMA 201 L65x65x4 2503 4.00 10.01 2 20.02
NMA 202 HT 45x45x4 1891 2.70 5.11 2 10.22
NMA 203 HT 45x45x4 1812 2.70 4.89 2 9.78
NMA 204 L45x45x4 1011 2.70 2.73 2 5.46
NMA 205 L90x90x6 246 8.20 2.02 2 4.04
NMA 206 HT 60x60x5 3902 4.50 17.56 2 35.12
NMA 207 HT 60x60x5 3902 4.50 17.56 2 35.12
NMA 208 HT 50x50x5 3587 3.80 13.63 2 27.26

Page 10 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE SUPER STRUCTURE

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)
NMA 209 HT 50x50x5 3587 3.80 13.63 2 27.26
NMA 210 6MM PLATE 150x344 47.10 2.43 2 4.86
NMA 211 L45x45x4 429 2.70 1.16 4 4.64
NMA 212 L45x45x4 1263 2.70 3.41 2 6.82
NMA 212 X L45x45x4 1263 2.70 3.41 2 6.82
NMA 213 L45x45x4 786 2.70 2.12 2 4.24
NMA 213 X L45x45x4 786 2.70 2.12 2 4.24
NMA 214 L45x45x4 1411 2.70 3.81 2 7.62
NMA 214 X L45x45x4 1411 2.70 3.81 2 7.62
NMA 215 8MM PLATE 127x277 62.80 2.21 2 4.42
NMA 215 X 8MM PLATE 127x277 62.80 2.21 2 4.42
NMA 216 HT 45x45x4 200 2.70 0.54 2 1.08
NMA 217 L45x45x4 739 2.70 2.00 2 4.00
NMA 218 HT 45x45x4 1599 2.70 4.32 2 8.64
NMA 219 HT 45x45x4 1491 2.70 4.03 2 8.06
NMA 220 L50x50x5 2871 3.80 10.91 1 10.91
NMA 220 A L50x50x5 2871 3.80 10.91 1 10.91
NMA 221 L65x65x4 2220 4.00 8.88 2 17.76
NMA 222 HT 45x45x4 1638 2.70 4.42 2 8.84
NMA 223 HT 45x45x4 1663 2.70 4.49 2 8.98
NMA 224 L45x45x4 879 2.70 2.37 2 4.74
NMA 225 L90x90x6 229 8.20 1.88 2 3.76
NMA 226 HT 65x65x5 3877 4.90 19.00 2 38.00
NMA 227 HT 65x65x5 3877 4.90 19.00 2 38.00
NMA 228 HT 50x50x5 3547 3.80 13.48 2 26.96
NMA 229 HT 50x50x5 3547 3.80 13.48 2 26.96
NMA 230 6MM PLATE 150x344 47.10 2.43 2 4.86
NMA 231 L45x45x4 426 2.70 1.15 4 4.60
NMA 232 L45x45x4 1237 2.70 3.34 2 6.68
NMA 232 X L45x45x4 1237 2.70 3.34 2 6.68
NMA 233 L45x45x4 781 2.70 2.11 2 4.22
NMA 233 X L45x45x4 781 2.70 2.11 2 4.22
NMA 234 L45x45x4 1410 2.70 3.81 2 7.62
NMA 234 X L45x45x4 1410 2.70 3.81 2 7.62
NMA 235 6MM PLATE 104x274 47.10 1.34 2 2.68
NMA 235 X 6MM PLATE 104x274 47.10 1.34 2 2.68
NMA 236 HT 45x45x4 200 2.70 0.54 2 1.08

Page 11 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE SUPER STRUCTURE

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)
NMA 237 L45x45x4 639 2.70 1.73 2 3.46
NMA 238 HT 45x45x4 1494 2.70 4.03 2 8.06
NMA 239 L45x45x4 1272 2.70 3.43 2 6.86
NMA 240 L50x50x5 2368 3.80 9.00 1 9.00
NMA 240 A L50x50x5 2368 3.80 9.00 1 9.00
NMA 241 HT 45x45x4 1974 2.70 5.33 2 10.66
NMA 242 HT 45x45x4 1384 2.70 3.74 2 7.48
NMA 243 HT 45x45x4 1525 2.70 4.12 2 8.24
NMA 244 L45x45x4 753 2.70 2.03 2 4.06
NMA 245 L90x90x6 211 8.20 1.73 2 3.46
NMA 246 HT 65x65x5 3838 4.90 18.81 2 37.62
NMA 247 HT 65x65x5 3838 4.90 18.81 2 37.62
NMA 248 HT 50x50x5 3518 3.80 13.37 2 26.74
NMA 249 HT 50x50x5 3518 3.80 13.37 2 26.74
NMA 250 6MM PLATE 150x344 47.10 2.43 2 4.86
NMA 251 L45x45x4 425 2.70 1.15 4 4.60
NMA 252 L45x45x4 1226 2.70 3.31 2 6.62
NMA 252 X L45x45x4 1226 2.70 3.31 2 6.62
NMA 253 L45x45x4 777 2.70 2.10 2 4.20
NMA 253 X L45x45x4 777 2.70 2.10 2 4.20
NMA 254 L45x45x4 1407 2.70 3.80 2 7.60
NMA 254 X L45x45x4 1407 2.70 3.80 2 7.60
NMA 255 6MM PLATE 105x257 47.10 1.27 2 2.54
NMA 255 X 6MM PLATE 105x257 47.10 1.27 2 2.54
NMA 256 HT 45x45x4 200 2.70 0.54 2 1.08
NMA 257 L45x45x4 583 2.70 1.57 2 3.14
NMA 258 HT 45x45x4 1438 2.70 3.88 2 7.76
NMA 259 L45x45x4 1147 2.70 3.10 2 6.20
NMA 260 L50x50x5 2110 3.80 8.02 1 8.02
NMA 260 A L50x50x5 2110 3.80 8.02 1 8.02
NMA 261 HT 45x45x4 1852 2.70 5.00 2 10.00
NMA 262 L45x45x4 1242 2.70 3.35 2 6.70
NMA 263 HT 45x45x4 1452 2.70 3.92 2 7.84
NMA 264 L45x45x4 677 2.70 1.83 2 3.66
NMA 265 L90x90x6 202 8.20 1.66 2 3.32
NMA 266 HT 70x70x5 3848 5.30 20.39 2 40.78
NMA 267 HT 70x70x5 3848 5.30 20.39 2 40.78

Page 12 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE SUPER STRUCTURE

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)
NMA 268 HT 50x50x5 3456 3.80 13.13 2 26.26
NMA 269 HT 50x50x5 3456 3.80 13.13 2 26.26
NMA 270 6MM PLATE 155x386 47.10 2.82 2 5.64
NMA 271 L45x45x4 412 2.70 1.11 4 4.44
NMA 272 L45x45x4 1236 2.70 3.34 2 6.68
NMA 272 X L45x45x4 1236 2.70 3.34 2 6.68
NMA 273 L45x45x4 737 2.70 1.99 2 3.98
NMA 273 X L45x45x4 737 2.70 1.99 2 3.98
NMA 274 L45x45x4 1323 2.70 3.57 2 7.14
NMA 274 X L45x45x4 1323 2.70 3.57 2 7.14
NMA 275 6MM PLATE 153x252 47.10 1.82 2 3.64
NMA 275 X 6MM PLATE 153x252 47.10 1.82 2 3.64
NMA 276 HT 45x45x4 200 2.70 0.54 2 1.08
NMA 277 L45x45x4 565 2.70 1.53 2 3.06
NMA 278 HT 45x45x4 1435 2.70 3.87 2 7.74
NMA 279 L45x45x4 1100 2.70 2.97 2 5.94
NMA 280 L50x50x5 1857 3.80 7.06 1 7.06
NMA 280 A L50x50x5 1857 3.80 7.06 1 7.06
NMA 281 HT 45x45x4 1700 2.70 4.59 2 9.18
NMA 282 L45x45x4 1142 2.70 3.08 2 6.16
NMA 283 HT 45x45x4 1430 2.70 3.86 2 7.72
NMA 284 L45x45x4 639 2.70 1.73 2 3.46
NMA 285 L90x90x6 192 8.20 1.57 2 3.14
TOTAL 9482.50 KGS

BOLTS & NUTS Per unit Wt Qty Total Wt.


M16x35 DIA BOLT 0.124 556 68.94
M16x40 DIA BOLT 0.132 742 97.94
M16x45 DIA BOLT 0.140 515 72.10
M16x50 DIA BOLT 0.148 404 59.79
M16x55 DIA BOLT 0.156 652 101.71
M16x60 DIA BOLT 0.164 14 2.30
M16x65 DIA BOLT 0.172 4 0.69

3.5 THK SPRING WASHER 0.009 2887 25.98


16x175 STEP BOLTS 0.417 93 38.78
5 THK.PACK WASHER FOR 16DIA BOLT 0.028 6 0.17

Page 13 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE SUPER STRUCTURE

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)
6 THK.PACK WASHER FOR16DIA BOLT 0.033 384 12.67
8 THK.PACK WASHER FOR 16DIA BOLT 0.044 80 3.52
10THK.PACK WASHER FOR16DIA BOLT 0.055 100 5.50

TOTAL= 490.10 KGS

GRAND TOTAL= 9972.60 KGS

Page 14 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE STRUCTURE: +3MTR EXTN

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)

NMA 300 HT 150x150x12 3012 27.30 82.23 3 246.68


NMA 300 S HT 150x150x12 3012 27.30 82.23 1 82.23
NMA 301 HT 130x130x10 456 19.70 8.98 4 35.93
NMA 302 8MM PLATE 120x456 62.80 3.44 8 27.49
NMA 303 L65x65x5 4049 4.90 19.84 2 39.68
NMA 303 X L65x65x5 4049 4.90 19.84 2 39.68
NMA 304 L50x50x5 4049 3.80 15.39 2 30.77
NMA 304 X L50x50x5 4049 3.80 15.39 2 30.77
NMA 305 L45x45x4 959 2.70 2.59 4 10.36
NMA 305 X L45x45x4 959 2.70 2.59 4 10.36
NMA 306 L45x45x4 1353 2.70 3.65 4 14.61
NMA 306 X L45x45x4 1353 2.70 3.65 4 14.61
NMA 307 L50x50x5 1869 3.80 7.10 4 28.41
NMA 307 X L50x50x5 1869 3.80 7.10 4 28.41
NMA 308 L50x50x5 1671 3.80 6.35 3 19.05
NMA 308 X L50x50x5 1671 3.80 6.35 3 19.05
NMA 308 Y L50x50x5 1671 3.80 6.35 1 6.35
NMA 308 Z L50x50x5 1671 3.80 6.35 1 6.35
NMA 309 L45x45x4 1057 2.70 2.85 4 11.42
NMA 309 X L45x45x4 1057 2.70 2.85 4 11.42
NMA 310 L60x60x5 5342 4.50 24.04 3 72.12
NMA 310 A L60x60x5 5342 4.50 24.04 1 24.04
NMA 311 8MM PLATE 190x324 62.80 3.87 4 15.46
NMA 312 HT 45x45x5 2990 3.40 10.17 4 40.66
NMA 313 HT 45x45x5 2990 3.40 10.17 4 40.66
NMA 314 HT 45x45x5 1270 3.40 4.32 4 17.27
NMA 315 L45x45x5 1442 3.40 4.90 4 19.61
NMA 315 X L45x45x5 1442 3.40 4.90 4 19.61
NMA 316 L50x50x5 2555 3.80 9.71 4 38.84
NMA 317 6MM PLATE 110x140 47.10 0.73 16 11.61

TOTAL 1013.51 KGS

Page 15 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE STRUCTURE: +3MTR EXTN

BOLTS & NUTS


M16x35 DIA BOLT 0.124 92 11.41
M16x40 DIA BOLT 0.132 88 11.62
M16x45 DIA BOLT 0.140 8 1.12
M16x50 DIA BOLT 0.148 16 2.37
M16x55 DIA BOLT 0.156 120 18.72

3.5 THK SPRING WASHER 0.009 324 2.92


M16x175 STEP BOLTS 0.417 4 1.67
6MM THK PACK WASHERS 0.033 32 1.06

TOTAL 50.87 KGS

GRAND TOTAL= 1064.38 KGS

Page 16 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE STRUCTURE: +6MTR.EXTN

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)

NMA 300 HT 150x150x12 3012 27.30 82.23 3 246.68


NMA 300 S HT 150x150x12 3012 27.30 82.23 1 82.23
NMA 301 HT 130x130x10 456 19.70 8.98 4 35.93
NMA 302 8MM PLATE 120x456 62.80 3.44 8 27.49
NMA 303 L65x65x5 4049 4.90 19.84 2 39.68
NMA 303 X L65x65x5 4049 4.90 19.84 2 39.68
NMA 304 L50x50x5 4049 3.80 15.39 2 30.77
NMA 304 X L50x50x5 4049 3.80 15.39 2 30.77
NMA 305 L45x45x4 959 2.70 2.59 4 10.36
NMA 305 X L45x45x4 959 2.70 2.59 4 10.36
NMA 306 L45x45x4 1353 2.70 3.65 4 14.61
NMA 306 X L45x45x4 1353 2.70 3.65 4 14.61
NMA 307 L50x50x5 1869 3.80 7.10 4 28.41
NMA 307 X L50x50x5 1869 3.80 7.10 4 28.41
NMA 308 L50x50x5 1671 3.80 6.35 3 19.05
NMA 308 X L50x50x5 1671 3.80 6.35 3 19.05
NMA 308 Y L50x50x5 1671 3.80 6.35 1 6.35
NMA 308 Z L50x50x5 1671 3.80 6.35 1 6.35
NMA 309 L45x45x4 1057 2.70 2.85 4 11.42
NMA 309 X L45x45x4 1057 2.70 2.85 4 11.42
NMA 310 L60x60x5 5342 4.50 24.04 3 72.12
NMA 310 A L60x60x5 5342 4.50 24.04 1 24.04
NMA 311 8MM PLATE 190x324 62.80 3.87 4 15.46
NMA 312 HT 45x45x5 2990 3.40 10.17 4 40.66
NMA 313 HT 45x45x5 2990 3.40 10.17 4 40.66
NMA 314 HT 45x45x5 1270 3.40 4.32 4 17.27
NMA 315 L45x45x5 1442 3.40 4.90 4 19.61
NMA 315 X L45x45x5 1442 3.40 4.90 4 19.61
NMA 316 L50x50x5 2555 3.80 9.71 4 38.84
NMA 317 6MM PLATE 110x140 47.10 0.73 16 11.61
NMA 600 HT 150x150x12 3012 27.30 82.23 3 246.68
NMA 600 S HT 150x150x12 3012 27.30 82.23 1 82.23
NMA 601 HT 130x130x10 456 19.70 8.98 4 35.93
NMA 602 8MM PLATE 120x456 62.80 3.44 8 27.49
NMA 603 L65x65x5 4209 4.90 20.62 2 41.25
NMA 603 X L65x65x5 4209 4.90 20.62 2 41.25
NMA 604 L50x50x5 4209 3.80 15.99 2 31.99
NMA 604 X L50x50x5 4209 3.80 15.99 2 31.99
NMA 605 L45x45x4 1039 2.70 2.81 4 11.22
NMA 605 X L45x45x4 1039 2.70 2.81 4 11.22

Page 17 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE STRUCTURE: +6MTR.EXTN

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)
NMA 606 L45x45x4 1405 2.70 3.79 4 15.17
NMA 606 X L45x45x4 1405 2.70 3.79 4 15.17

Page 18 of 19
BILL OF MATERIAL

PURCHASER: AP TRANSCO TOWER: "A"(NMA)


DESCRIPTION: 220KV M/C TRANSMISSION LINE STRUCTURE: +6MTR.EXTN

PROJECT: CONSTRUCTION OF 220KV DC LINE ON NARROW BASE MULTI CKT TOWERS FROM 400KV
MAMIDIPALLY SS TO PROPOSED 220KV FAB CITY SS - APT-E-8-2010
LENGTH UNIT WT. PC. WT.
MARK No. SECTION QTY. TOTAL (Kg.) REMARKS
(mm) (Kg./M) (Kg.)
NMA 607 L65x65x4 2027 4.00 8.11 4 32.43
NMA 607 X L65x65x4 2027 4.00 8.11 4 32.43
NMA 608 L65x65x4 1771 4.00 7.08 4 28.34
NMA 608 X L65x65x4 1771 4.00 7.08 4 28.34
NMA 609 L45x45x4 1076 2.70 2.91 4 11.62
NMA 609 X L45x45x4 1076 2.70 2.91 4 11.62
NMA 610 L60x60x5 5806 4.50 26.13 4 104.51
NMA 611 8MM PLATE 187x341 62.80 4.00 4 16.02
NMA 612 L65x65x4 3270 4.00 13.08 4 52.32
NMA 613 L65x65x4 3270 4.00 13.08 4 52.32
NMA 614 HT 45x45x5 1383 3.40 4.70 4 18.81
NMA 615 L45x45x5 1498 3.40 5.09 4 20.37
NMA 615 X L45x45x5 1498 3.40 5.09 4 20.37
NMA 616 L50x50x5 2781 3.80 10.57 4 42.27
NMA 617 6MM PLATE 110x140 47.10 0.73 16 11.61
TOTAL 2088.48 KGS

BOLTS & NUTS


M16x35 DIA BOLT 0.124 184 22.82
M16x40 DIA BOLT 0.132 176 23.23
M16x45 DIA BOLT 0.140 16 2.24
M16x50 DIA BOLT 0.148 32 4.74
M16x55 DIA BOLT 0.156 240 37.44

3.5 THK SPRING WASHER 0.009 648 5.83


M16x175 STEP BOLTS 0.417 8 3.34
6MM THK PACK WASHERS 0.033 64 2.11

TOTAL= 50.89KGS
101.74 KGS

GRAND TOTAL= 2190.23 KGS

Page 19 of 19