You are on page 1of 1

XENCOM USER MANUAL

Basic functions:

1. power on the system.

2. wait for the sim to register to network.

3. when successfully registered to network the device will go to standby mode.

4. once in a standby mode you can make a call.

5. when the call is connected the system will automatically receive your call.

6. once your call is received type in the default password which is 1234. after
that press 1 to turn on /off the pump. you can now disconnect the call. you can
call again to change the status of pump.

Additional Features:

1. in standby mode when the water level gets to the preset low threshold the system
will notify you by giving a call. you can disconnect that call and then call the
system to turn on the pump.

2. once the water level gets to the preset high threshold the system will
automatically turn the pump off without notifying you.

Manual Mode:

1. you can also operate the system manually by the keypad provided on the system.

2. when the system is in a standby mode press any key on the keypad and the system
will prompt you for the password which by default is 1234.

3. when the password is correct the system show the manual mode dialog from which
you can turn on the pump manually by pressing the green push button provided on the
device or make an emergency call to the predefined number.

4. to turn off the pump manually you must go back to standby mode and press and
hold the red push button.

Troubleshooting:

1. sometimes the device may get hanged on "call in progress" screen even after
disconnecting the call. to fix call again and disconnect when its ringing. the
device will go to the standby mode again. repeat if necessary.

2. if you want to use emergency calling feature provided in manual mode you need to
reprogram the microcontroller because number predefined is out of service.

You might also like