You are on page 1of 3
DATE To 7 ATTENTION PROJECT SUBJECT F.L FIGUEROA & ASSOCIATES INC. (670 CAVO F. SANCHEZ STREET, CITY OF MANDALUYONG, PHILIPPINES, ENGINEERS * CONSULTANTS TEL NOS,(632) 719-4811 /531-7721 FAX NO. 531-6514 EMAIL ADDRESS: ffainc@yahoo.com * fgueroeferdinand @yahoo.com Aer November 2, 2017 MC Montgear Project in Charge ‘South West ITS Request for Approval RANSMITTAL SHEET Gl -FOR REFERENCE CLOTHERS WE TRANSMIT HEREWITH THE FOLLOWING No. OF SETS | No. OF SHEETS DESCRIPTION 1 [Phoenix Clevis and Loop Hanger with Sample Board sHeeennanseseaesenee Nothing Follows *######exeeexensase TRANSMITTED BY : Frederick Padilla RECEIVED BY =: DATE : November 2, 2017 DATE CLEVIS HANGER PHOENIX FIG, 260: LOADS (LBS) « WEIGHTS (LBS) + DIMENSIONS (IN) Max | Span Rod Rod Take] Adjust. Width Load | Fe. [Melahtlsizea| ® | © F | S | Lower 610 oa rT] ™ [oss * (0.40 730 5} 995 | 1 10" | 0.50 th i [065 9h 1360 [ 72" [0.86 1% | % af 1.10 Te 7 74a 1.54 Te iz 1.430" [1.70 BA [1% | % |The Tao | 7 [3.10 oT | ay ‘s 2000 | 18" | 475 Te [ 2 te b 40_| 3800 | 22" | 860 | Wm | em] 4 | Pe 7 12 | 3800 | 23° | 11.20 Te [17% | 106 | Ye 5 14_ [4200 | 25" | 12.50 1% | 19% | 10% | 2% | % a 16 | aa00 [27 [1985] 1 [te [a | 2 | mI, | 3, Iga 8 4800| 28 [22.25 75% | 24%e | 13% | Ye a 20_| 4800 |~30_| 40.33 11. | 27% | 18% |, | TH 24 | 4800 [32 [4983] 1% [19% | a1%6 | 17H | 2% [mw | 9 307 | 6000 | 33 | 70.18 26%0 | 38%e | 21% | BA | 1H Pipe Sizes 1" andLarger *Span’ represents themaximum recommended distance between hangers ona continuous andstraight run of horizontal standard weight ste! pipe filed with water.Inallcases, verify that chosen locationof hangersdoes notsubjecthangers oa load greater than the maximum recommended loed shown above. “idicaes thet span represents the maximum span for water filled pipe. +The 24” pipe size assembly includes a 11/4" SCH 40 pipe spacer over the 7/8” threaded rod. “+ 30" pipe size: When assembled, the U-strap sits outside ofthe yoke LOOP HANGER PHOENIX ‘Size Range: %' through 8° ‘Material: Carbon Stee! Finish: Strap is Pre-Galvanized Zinc Material. Nut is Zinc Plated Service: Recommended for suspension of non-insulated stationary pipe line, ‘Maximum Temperature: 650°F ‘Approvals: Complies with Federal Specification A-A-1192A (Type10) \WW-H-171 (Type 10), ANSUIMSS SP-69 and MSS SP-58 (Type 10) UL Listed and FM Approved (Sizes %"— 8°), Features: ‘© Threads are countersunk so that they cannot become burred or damage. ‘+ Knurled swivel nut provides vertical adjustment after piping is in place, ‘© Captured swivel nut in the %" through 6" sizes. The capture is permanent in ‘The bottom portion of the band, allowing the hanger to be opened during installation i desired, but not allowing the nut to fall completely out Ordering: Specify size, figure number and name. Note: The acceptability of galvanized coatings at temperatures above 450°F is at the discretion of the end user. Metric nut available upon request. Non-captured nut also available upon request FIG. 69 ae a ON (iN) | Maxtoad | Weight | RodsieA |B i irees! Pipe Size a ag ; %

You might also like