of frames occurs at an angle which will

also induce significant loads on the other


set of frames (WillfordA/lsop,
Georgiou/Vickery/Church).

Full and partial loading of structures


given in ASCE 7 section 6.8 were
developed for clad structures only. The
provisions of that paragraph are not
applicable to open frame structures due
to the different flow characteristics

4.2.6.2 When, in the engineer's C4.2.6.2 These provisions are an


judgment, there is substantial shielding of attempt by the committee to recognize
equipment by the structure or other the beneficial effects of shielding of
equipment on a given level in the wind equipment by the structure and other
direction under consideration, the wind equipment. The form is very loosely
., load on equipment in 4.2.6.1 on that level based on shielding equations developed
may be reduced by the shielding factor 1'\. for sets of trusses, with an additional
"
factor introduced to account for the
(E+ 8.3)
1'\ = (1 - E ) (4-4) presence of solid elements.

where 1'\ ~ 0.4. The factor 1C is used to account for


equipment to equipment, and equipment
The solidity ratio E is defined in 4.2.4. to structure shielding.

1C is the volumetric solidity ratio for


the level under consideration, defined as
the ratio of the sum of the volumes of all
equipment, vessels, exchangers, etc. on a
level of the structure to the gross volume
ofthe structure at that level.

1C should be taken as 0 when there is


no equipment to equipment shielding
(e.g., if there is only one exchanger or
vessel on the level under consideration,
or the equipment is widely spaced).

The wind load on any equipment or


portion thereof which extends above the
top of the structure shouid not be
reduced.