What is the NM3/hr (normal cubic meter per hour) and SM3/hr (standard cubic meter
per hour) flowrate corresponding to 100m3/hr of nitrogen flowing through a pipe?
Operating temperature of nitrogen stream is 800C. Operating pressure at the point
of flow measurement is 25 bar.
Solution
The calculation of normal and standard gas flowrates (NM3/hr and SM3/hr
calculation), first requires the normal and standard conditions to be fixed. Normal
temperature and pressure conditions are already defined in the problem statement
and standard temperature and pressure conditions defined by NIST are to be used.