Demands on Girder

Span 13.64 m
Tributary Width 1.36 m
Girder Area 0.33 m2
Girder SW 8.2 kN/m max slab
thickness
Girder DL BM 190 kNm
Girder DL SF 56 kN
Slab max thickness 0.371 m
min thickness 0.371 m
Slab BM 293 kNm
Slab SF 86 kN
Total Girder DL BM 483 kNm
Total Girder DL SF 142 kNm
Footpath Deck
thickness 0 m
Footpath SF 0 kNm
Footpath BM 0 kN
Barrier Width 0.00 m if barrier is located on this girder
Barrier Load 0.0 kN/m
Barrier BM 0 kNm
Barrier SF 0 kN
Surfacing 0 kN/m
Services 2.8 kN/m
Surfacing+services BM 65 kNm
Surfacing+services SF 19 kN
Total SDL BM 65 kNm
Total SDL SF 19 kN
HN UDL / Footpath UDL 0 kPa
HN UDL BM 0 kNm
HN UDL SF 0 kN
HN Wheel Loads AASHTO Distribition for T beams
No of lanes 2 1 lane S/1.98
Wheel Distribution factor 0.74 2 or more lanes S/1.83
HN BM 193 kNm
HN SF 98 kN (assume two 60 kN loads)
Footpath 0 kPa
Footpath BM 0 kNm
Footpath SF 0 kN

Serviceability Load Case for load combination 1A


BM 798 includes 1.3 impact
Live load factor @ SLS 1

Ultimate Load Case for load combination 1A


BM 1304 kNm
SF 504 kN
Serviceability Girder Stresses: General Case
Girder Depth 0.65 m
DHC Composite D= 0.65 m No of strands 24 yt
Span = 18 Slab t = 0 m

Composite Section Girder Section Pult


A 0.4443 m^2 A 0.4443 m^2 P 2428.8 KN 0.55 %fpu 184
I 0.023 m^4 I ### m^4 Ptransfer 3091 KN 0.7 %fpu
Y slab top 0.328 m Y girder 0.328 m top ecc mid -0.193 m
Y girder 0.328 m top girder Y girder 0.322 m bot yt = 0.521 m
Y girder 0.322 m bot

MIDSPAN STRESS TRANSFER STRESSES


Critical Stress Stress Stress Critical Stress Stress Stress
Class Combination Moment Girder Girder Slab Class Combination Moment Girder Girder Slab
Bottom Top Top Bottom Top Top
KNm MPa MPa MPa KNm MPa MPa MPa

P/A 5.47 5.47 P/A 6.96 6.96


P*ecc*Y/I 6.64 -6.78 P*ecc*Y/I 8.45 -8.63

SUB TOTAL 12.11 -1.31 SUB TOTAL 15.41 -1.67

Girder DL 450 -6.39 6.52 Girder DL 190 -2.69 2.75


Slab DL 0 0.00 0.00 (Girder SW Only)

SUB TOTAL 450 -6.39 6.52 SUB TOTAL -2.69 2.75

LC1A Footpath DL 0
Barrier DL 0
SDL 93
Footpath UDL 628
HN UDL (I=1.3) 0
HN Wheel loads (I=1.3) 0

Total Loads 721 -10.24 10.45 10.45

TOTAL -4.52 15.66 10.45 TOTAL 12.72 1.08 0.00


ALLOWABLE STRESS : Tension=0.0, Compression=18.0 MPa (fcu=45) ALLOWABLE STRESS : Tens.=-2.95, Comp.=21 MPa (fcu=35 MPa at transf.)

LC4 HO load Case


Footpath
Ignore DL cases
these load 0
Barrier DL 0
SDL 93
Footpath UDL 628
UDL 0
HO Wheel loads 0 use a value of 1.5 to allow for 1 lane HN +1 lane HO
Total Load 721 -10.24 10.45 10.45

0.33Temperature 0.00 0.00 0.00

TOTAL -4.52 15.66 10.45


ALLOWABLE STRESS : Tension=-3.4 MPa, Compression=20.3 MPa (fcu=45)

HN load Case
LC2A Footpath DL 0
Barrier DL 0
SDL 93
Footpath UDL 628
HN UDL (I=1.3) 0
HN Wheel loads (I=1.3) 0
Total Loads 721 -10.24 10.45 10.45

Temperature 0.00 0.00 0.00

TOTAL -4.52 15.66 10.45


ALLOWABLE STRESS : Tension=-3.4 MPa, Compression=20.3 MPa (fcu=45)