You are on page 1of 2

Demands on Girder

Span 28 m
Tributary Width 3 m
Girder Area 0.54 m2
Girder SW 13.6 kN/m max slab
thickness
Girder DL BM 1330 kNm
Girder DL SF 190 kN
Slab max thickness 0.2 m
min thickness 0.2 m
Slab BM 1470 kNm
Slab SF 210 kN
Total Girder DL BM 2800 kNm
Total Girder DL SF 400 kNm
Footpath Deck
thickness 0 m
Footpath SF 0 kNm
Footpath BM 0 kN
Barrier Width 0.00 m if barrier is located on this girder
Barrier Load 0 kN/m
Barrier BM 0 kNm
Barrier SF 0 kN
Surfacing 8.3 kN/m
Services 0 kN/m
Surfacing+services BM 813 kNm
Surfacing+services SF 116 kN
Total SDL BM 813 kNm
Total SDL SF 116 kN
HN UDL / Footpath UDL 0 kPa
HN UDL BM 0 kNm
HN UDL SF 0 kN
HN Wheel Loads AASHTO Distribition for T beams
No of lanes 0 1 lane S/1.98
Wheel Distribution factor 1.52 2 or more lanes S/1.83
HN BM 0 kNm
HN SF 0 kN (assume two 60 kN loads)
Footpath 5 kPa
Footpath BM 1470 kNm
Footpath SF 210 kN
Serviceability Girder Stresses: General Case
Girder Depth 1.20 m
Tee Roff Girder Composite D= 1.4 m No of strands 44 yt
Span = 28 Slab t = 0.2 m

Composite Section Girder Section Pult


A 1.1430 m^2 A 0.543 m^2 P 6050 KN 0.55 %fpu 250
I 0.260 m^4 I 0.104 m^4 Ptransfer 7700 KN 0.7 %fpu
Y slab top 0.450 m Y girder 0.636 m top ecc mid -0.389 m
Y girder 0.250 m top girder Y girder 0.564 m bot yt = 1.025 m
Y girder 0.950 m bot

MIDSPAN STRESS TRANSFER STRESSES


Critical Stress Stress Stress Critical Stress Stress Stress
Class Combination Moment Girder Girder Slab Class Combination Moment Girder Girder Slab
Bottom Top Top Bottom Top Top
KNm MPa MPa MPa KNm MPa MPa MPa

P/A 11.14 11.14 P/A 14.18 14.18


P*ecc*Y/I 12.76 -14.39 P*ecc*Y/I 16.24 -18.32

SUB TOTAL 23.90 -3.25 SUB TOTAL 30.42 -4.14

Girder DL 1330 -7.21 8.14 Girder DL 1330 -7.21 8.14


Slab DL 1470 -7.97 8.99 (Girder SW Only)

SUB TOTAL 2800 -15.19 17.13 SUB TOTAL -7.21 8.14

LC1A Footpath DL 0
Barrier DL 0
SDL 813
Footpath UDL 1470
HN UDL (I=1.3) 0
HN Wheel loads (I=1.3) 0

Total Loads 2283 -8.33 2.19 3.94

TOTAL 0.38 16.06 3.94 TOTAL 23.21 4.00 0.00


ALLOWABLE STRESS : Tension=0.0, Compression=18.0 MPa (fcu=45) ALLOWABLE STRESS : Tens.=-2.95, Comp.=21 MPa (fcu=40 MPa at transf.)

LC4 HO load Case


Ignore these load
Footpath DL cases 0
Barrier DL 0
SDL 813
Footpath UDL 1470
UDL 0
HO Wheel loads 0 use a value of 1.5 to allow for 1 lane HN +1 lane HO
Total Load 2283 -8.33 2.19 3.94

0.33Temperature 0.00 0.00 0.00

TOTAL 0.38 16.06 3.94


ALLOWABLE STRESS : Tension=-3.4 MPa, Compression=20.3 MPa (fcu=45)

HN load Case
LC2A Footpath DL 0
Barrier DL 0
SDL 813
Footpath UDL 1470
HN UDL (I=1.3) 0
HN Wheel loads (I=1.3) 0
Total Loads 2283 -8.33 2.19 3.94

Temperature 0.00 0.00 0.00

TOTAL 0.38 16.06 3.94


ALLOWABLE STRESS : Tension=-3.4 MPa, Compression=20.3 MPa (fcu=45)

382910834.xls Page 2 08:40:29 03/30/2018