Ted Cable Geometry
Span 28 m
Tributary Width 3 m
Girder Area 0.54 m2
Girder SW 13.6 kN/m max slab
thickness
Girder DL BM 1330 kNm
Girder DL SF 190 kN
Slab max thickness 0.2 m
min thickness 0.2 m
Slab BM 1470 kNm
Slab SF 210 kN
Total Girder DL BM 2800 kNm
Total Girder DL SF 400 kNm
Footpath Deck
thickness 0 m
Footpath SF 0 kNm
Footpath BM 0 kN
Barrier Width 0.00 m if barrier is located on this girder
Barrier Load 0 kN/m
Barrier BM 0 kNm
Barrier SF 0 kN
Surfacing 8.3 kN/m
Services 0 kN/m
Surfacing+services BM 813 kNm
Surfacing+services SF 116 kN
Total SDL BM 813 kNm
Total SDL SF 116 kN
HN UDL / Footpath UDL 0 kPa
HN UDL BM 0 kNm
HN UDL SF 0 kN
HN Wheel Loads AASHTO Distribition for T beams
No of lanes 0 1 lane S/1.98
Wheel Distribution factor 1.52 2 or more lanes S/1.83
HN BM 0 kNm
HN SF 0 kN (assume two 60 kN loads)
Footpath 5 kPa
Footpath BM 1470 kNm
Footpath SF 210 kN
Serviceability Girder Stresses: General Case
Girder Depth 1.20 m
Tee Roff Girder Composite D= 1.4 m No of strands 44 yt
Span = 28 Slab t = 0.2 m
LC1A Footpath DL 0
Barrier DL 0
SDL 813
Footpath UDL 1470
HN UDL (I=1.3) 0
HN Wheel loads (I=1.3) 0
HN load Case
LC2A Footpath DL 0
Barrier DL 0
SDL 813
Footpath UDL 1470
HN UDL (I=1.3) 0
HN Wheel loads (I=1.3) 0
Total Loads 2283 -8.33 2.19 3.94