You are on page 1of 6

RAFT FOUNDATION DESIGN

1 - GENERAL
Ultimate strength design method is used for reinforced concrete design.
For the stability check of foundation earth cone method is used.It is assumed that
sides of the cone make an angle (frustrum angle) with vertical.
Foundation design is checked according to overturning and compression.

2 - MATERIAL CHARACTERISTICS
Concrete : BS20 (C20)
Characteristic compressive strength of concrete 160 kg/cm2
Design compressive strength of concrete 130 kg/cm2
Design tensile strength of concrete 10,0 kg/cm2
Shear stregth of concrete 10 kg/cm2
Specific weigth of concrete 2400 kg/m3

Reinforcing steel bar :


St IIIa Yield strength of steel 4200 kg/cm2
Max.Allowable Design Stress 3.652 kg/cm2
St I Yield strength of steel 2500 kg/cm2
Max.Allowable Design Stress 2.174 kg/cm2

3 - LOADING
Loads are taken from Structural analysis/foundation loads sheets. Moments at base are
calculated according to these loads. (At both X and Y direction.)

4 - FOUNDATION TYPE
Raft type foundation are used for this antenna type of tower.

5 - SOIL PARAMETERS
Soil parameters are on the calculation sheets for each type of antenna tower.

REVISION Page No
a
ANTENNA TOWER HT- 40 GSM TOWERS b 1
c
RAFT FOUNDATION DESIGN

SOIL PARAMETERS :

Unit Weight of Soil : 1800 kg/m3


Soil Bearing Capacity : 1 kg/cm2
Frustrum Angle : 20 °

Moments At Base

1)x-x Direction :

Mxx overturning = 696406 kgm


S.F. = 1,3
= 696406 kgm with safet factor

Hy horizontal = 38 kN Max H= 40 KN
= 3874 kg 4077,472 kg
= 3874 kg 5300,714 kg
V tension = 566 kN
= 57696 kg
= 75005 kg
Vcompres = 610 kN
= 62181 kg
= 80836 kg

2) y-y Direction :

Myy overturning = 0 kNm


= 0 kgm
S.F. = 1,3
= 0 kgm with safet factor

Hy horizontal = 0 kN
= 0 kg
= 0 kg

Symetrical

REVISION Page No
a
ANTENNA TOWER HT- 40 GSM TOWERS b 2
c
RAFT FOUNDATION DESIGN

A A
0,65 0,65 2tanD= Stup Type foundat 0,06
4,504

0,30 HK

2,00 D D H
0,6 4,642 0,6

0,50
T

4,672
Overturning Check = B= 6,492

Mtotal overturning = 535697 kgm without safety factor


Mtotal overturning = 696406 kgm with safety factor

Vconcrete = B² * T + 4 * H* A²
= 25,0 m3

Vsoil = H / 3 ( B² + E² + B * E ) - Vchimney
= 101,2 m3
E = 7,948 m
W foundation = Vcon*2400+Vsoil*1700
= 231992 kg

6N = 243654 kg =(Vten^2+Vcom^2)+Wfoun

e = 0,39 m OK %0RY61
M resisting = 6N*B/2
= 790900 kgm

F.S = M resisting / Mtotal overturning


= 1,1 overturning is not critical OK

Base Pressure Check =


V = 6N / B2 (1+- 6e/B)
Vmax = 0,79 < 1,00 OK
Vmin = 0,37

REVISION Page No
a
ANTENNA TOWER HT- 40 GSM TOWERS b 3
c
RAFT FOUNDATION DESIGN

Reinforcement Calculation =

a ) Raft Reinforcement =

M a-a = (( Vaa * L² ) / 2 + ( Vmax - Vaa ) * L² ) / 3 ) * B


M a-a = 902788 kgcm
Vaa = 0,75 kg/cm2

As = M a-a / fyd * j * d
= 10 cm2

Min. reinforcement Area = B * T * 0.003 91 cm2


Use St IIIa in both directUse St IIIa 46 I 16 Ast= 92 Enough Reinf.
for one level OK.
TOTAL Reinforcement……………… 92 I 16

b ) Chimney Reinforcement = Unit weigh I 16 1,58

M = Hx,z * (H+HK)
= 1219164 kgcm

As = M / fyd * j * d
= 9,94 cm2 ( At one side )1.25 safety

Use St IIIa 5 I 16 Ast= 10 Enough Reinf.


Total Reinf: 16 OK.
Unit weight I 16 1,58

13,8

13,8

13,8
5
I kg/m
c) Stirrups I 8/ every 20 cm Use St I unit weghts I 8 0,39
unit weghts I 10 0,61
Unit weigh I8 0,39 unit weghts I 14 1,21
unit weghts I 16 1,58
6) Chair I 16 every 1 m2 Use St I unit weghts I 18 2
unit weghts I 20 2,47
Unit weigh I 16 1,58 unit weghts I 24 3,55
unit weghts I 26 4,17
unit weghts I 30 5,55
REVISION Page No
a
ANTENNA TOWER HT- 40 GSM TOWERS b 4
c
RAFT FOUNDATION DESIGN

PUNCHING CHECK

Hn
T-5

Hn=A+2*((T-5)tan(45))/2 110,00 CM
Apunc=Hn*(T-5)*4 19800 CM2
Tp=Fcomp/Apunc = 4,1 kg/cm2 < 10 kg/cm2 OK

REVISION Page No
a
ANTENNA TOWER HT- 40 GSM TOWERS b 5
c
A B C B A FOUNDATION GEOMETRICAL DIMENSIONS (cm)

60 65 399 65 60 A B C D E F G H1 H2 H3 H
60 65 399 450 637 529 649 50 200 30 280

EXCAVATION DIMENSIONS (cm)


EX - 1 EX - 2 EX - 3
669 669 290

FOUNDATION REINFORCMENT DIMENSIONS (cm)

BASE REINFORCMENT COLON REINFORC. STRIPS CHAIRS

669
R1 R2 R3 R4 R5 R6 R7 R8

450
E 637 LENGHT 30 629 30 629 30 260 230 140

649
D BAR SIZE 16 16 16 16 16 16 8 16
G QUANTITY 92 46 92 46 64 64 67 42

EX - 2
WEIGHT 44 457 44 457 30 263 60 93

TOTAL W. 501 501 293 60 93

FOUNDATION TOTALS

EXCAVATION TOTAL 130 M3

CONCRETE TOTAL 25 M3

REINFORCMENT TOTAL 1.448 KG

R2
EX -1 = 669 R1
LENGTH = 689 cm UPPER LEVEL NOTES
D = 450 TYPE= ‡ 16
QUANTITY= 46 23 + 23
1-U 1- ALL DIMENSIONS ARE IN CM.
WEIGHT= 501 kg 2- CONRETE 28 DAYS STRENGTH 200 Kg/cm2
stub 3- FORMED IRON BARS STRENGTH 42 Kg/mm2 YIELDING .
4- FORMED IRON BARS STRENGTH 25 Kg/mm2 YIELDING .
BASE REINFORCMENT 5- SOIL BEARING CAPACITY 1 KG/CM2

30
ground

H3
level
LENGTH = 689 cm
TYPE= ‡ 16
D R3 QUANTITY= 46 23 + 23 1-L
2

280
WEIGHT= 501 kg
column LOWER LEVEL
reinf. R4

200
H2
290

H
3
strips

EX - 3
upper 1-U
reinf.

COLUMN REINFORCMENT 2

50
R6

H1
R5
LENGTH = 290 cm
TYPE= ‡ 16 REVISION DATE NOTES DRW. APPR.
plane QUANTITY= 64 16 x 4
concrete WEIGHT= 293 kg PROJECT: TOWER TYPE : HT- 40 GSM TOWERS
min 10 cm 1-L lower reinf.
4 4
chairs
CHAIRS FOUNDATION DESIG CALCULATIONS
A F A
60 529 60 30 LENGTH = 140 cm SOIL TYPE BEARING CAPACITY 1 kg/cm2
R8 TYPE= ‡ 16
QUANTITY= 42 1/1 m2 DATE
WEIGHT= 93 kg APPROVE G.KIRGIZ
DESIGN G.KIRGIZ
25 25 DRAWN D.KOSE

D Slope of chimney 3
STRIPS
For stup foundation = 0,06
LENGTH = 230 cm
5 TYPE= ‡ 8
QUANTITY= 67 17 x 4
WEIGHT= 60 kg

SCALE DIMENSIONS IN CM DRW.NO


R7

You might also like