Cover to Reinforcement (Walls: BS 8110)
For 1 layer of reinforcement, the vertical bar is on the centreline of the wall thickness, the face of the horizontal bar is closest to the critical concrete face. For 2 layers of reinforcement, the horizontal bars are placed outside the vertical bars at each face. The nominal concrete cover is measured to the face of the horizontal bar or any link/containment transverse reinforcement that may be present. You are required to set a minimum value for the nominal cover, cnom,u, for each wall in the wall properties. These values are then checked against the nominal limiting cover, cnom,lim which depends on the diameter of the reinforcement and maximum nominal aggregate size, hagg (specified in Design Options > Wall > General Parameters). If cnom,u < cnom,lim then a warning is displayed in the calculations.