You are on page 1of 13

Feature Deployment and Testing Guide

SIB11bis
Feature ID: ZWF21-01-009

Version: V3.11.10

ZTE CORPORATION
NO. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: +86-755-26771900
Fax: +86-755-26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn
LEGAL INFORMATION
Copyright © 2012 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by
contractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History

Revision No. Revision Date Revision Reason

R1.0 2012-08-09 First edition

Serial Number: SJ-20120802112720-010

Publishing Date: 2012-08-09 (R1.0)

SJ-20120802112720-010|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Contents
Chapter 1 Functional Description ............................................................. 1-1
Chapter 2 Preparations .............................................................................. 2-1
Chapter 3 Data Configuration.................................................................... 3-1
Chapter 4 Testing ....................................................................................... 4-1
4.1 Test Purpose...................................................................................................... 4-1
4.2 Steps for Test..................................................................................................... 4-1
4.3 Expected Results ............................................................................................... 4-1

Chapter 5 Counter List............................................................................... 5-1

SJ-20120802112720-010|2012-08-09 (R1.0) ZTE Proprietary and Confidential


II

SJ-20120802112720-010|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Chapter 1
Functional Description
The content of SIB11bis is same with SIB11; it can alleviate the lack of SIB11 space
when there are too many adjacent cells. The parameter “SIB11orSIB11bis” can specify
if adjacent cell information can be broadcast through SIB11bis. So the adjacent cell’s
information will broadcast by SIB11bis when the space of SIB11 is depleted.

1-1

SJ-20120802112720-010|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Feature Deployment and Testing Guide Feature ID: ZWF21-01-009

This page intentionally left blank.

1-2

SJ-20120802112720-010|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Chapter 2
Preparations
License
This Feature is controlled by license, the license parameters is:
gsmRelation.GSMSIB11ORSIB11BIS
utranRelation.Sib11orSib11bis

Hardware Requirement

NE Requirement

RNC None

NodeB None

Software Requirement

NE Involved Version Requirement Notes

UE YES UMTS FDD Number: 1 SamsunGT-


Category: Any 19100
Release: R7, R8

Node B YES V4.11.10.14 ZTE equipment

RNC YES V3.11.10.11 ZTE equipment

MSCS YES ZTE equipment

MGW YES ZTE equipment

SGSN YES ZTE equipment

GGSN NO

HLR NO

2-1

SJ-20120802112720-010|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Feature Deployment and Testing Guide Feature ID: ZWF21-01-009

Topology
Topology is shown in Figure 2-1.

Figure 2-1 Topology

2-2

SJ-20120802112720-010|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Chapter 3
Data Configuration
SGSN/GGSN - ZTE
N/A

MSC/MGW - ZTE
N/A

HLR - ZTE
N/A

RNC
Configure the neighbor cell information and belong to SIB11bis
Path: View > Configuration Management > RNC Managed Element > RNC Radio
Resource Management > Utran Cell > Utran Cell xxx > Neighboring Cell >
Neighboring Cell xxx > Neighboring Physical Cell Identity
Path: View > Configuration Management > RNC Managed Element > RNC Radio
Resource Management > Utran Cell > Utran Cell xxx > Neighboring Cell >
Neighboring Cell xxx > Broadcast in either SIB11 or SIB11bis

Node B
N/A

3-1

SJ-20120802112720-010|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Feature Deployment and Testing Guide Feature ID: ZWF21-01-009

This page intentionally left blank.

3-2

SJ-20120802112720-010|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Chapter 4
Testing
Table of Contents
Test Purpose ..............................................................................................................4-1
Steps for Test .............................................................................................................4-1
Expected Results .......................................................................................................4-1

4.1 Test Purpose


The purpose of this test case is to verify the system supports SIB11bis and the maximum
number of neighbor cells is 96.
Related document:
ZTE UMST Connection Management Feature Guide

4.2 Steps for Test


1. Power on UE1 and camps on Cell1 in Idle mode
2. Configuration the CELL1 neighbor CELL2 and set CELL2 belong to SIB11bis.

3. Reduce the cell1 power or UE far from the CELL1.

4.3 Expected Results


Cell2 can be broadcast in sib11 bis message and cell reselection procedure is normal.

4-1

SJ-20120802112720-010|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Feature Deployment and Testing Guide Feature ID: ZWF21-01-009

This page intentionally left blank.

4-2

SJ-20120802112720-010|2012-08-09 (R1.0) ZTE Proprietary and Confidential


Chapter 5
Counter List
There is no any counter related to Iu Flex feature.

5-1

SJ-20120802112720-010|2012-08-09 (R1.0) ZTE Proprietary and Confidential