DCR:
- Increase HOCDCMINDWPWR (18) & HOCDCMINUPPWR (10)
- RACHACCLEV to -105
- RXMIN (Minum Access RXLEV) default 8 (-102 dBm) can change to 10 (-100 dBm)
- CALLRESTABDIS (Call Reestablishment Forbidden) from yes to no
- RANERRTHRED (Random Access Error Threshold) - default 225 (meaning 40 from
41 bits trainning should be correct,then RACH will be accepted)
HOSR:
- audit neighbor (1st tier harus lengkap & bothway)
- Pbgt margin increase untuk yg banyak fail (better cell)
- Intercell HO hysterisis increase untuk yg banyak fail (uplink/downlink quality/level)
- increase min level offset.
- Increase HOCDCMINDWPWR (18) & HOCDCMINUPPWR (10)
- T3103 diperpanjang 20000 ms untuk mendelay release ketika channel belum dapat
FACH
INTERCELLHYST – BQMARGIN : trigger HO. Makin postif makin sulit, makin negatif
makin mudah.
Memang sebenernya root causenya ada di alarm2 & clock problem yg blm jelas nasibnya gmana
OKI, dari sisi qta coba qta optimize lagi sebisanya.
Beberapa minggu terakhir aq ma mas utomo udah coba beberapa trial namun hasilnya masih tidak terlalu
memuaskan, antara lain sbb :
-, MAXTA
-. TCHDROPSTATUL/DLLEV
-. TCHDROPSTATUL/DLQUAL
-. TCHDROPSTATUL/DLFER
Nah, skarang waktunya qta coba improve'in disemua BSC supaya KPI region qta bs < 1% (kurang 0.2%
lagi da T------------T)
Gpp juga klo misalnya nantinya improve perBSCnya dikit2 tp klo digabungin kan jd besar hehehe...amin.
Coba dibreakdown lagi di BSC nya masing2 ada masalah apa dgn DCR nya (UL/DL lev, UL/DL qual, UL,
TA dsb) trus coba di improve dgn parameter yg berhubungan.
Semoga ini minggu terakhir regional DCR nya berwarna merah.