Table 282 FXED LEDs (Cont.)
LED color Description Alarm
Periodic Red and Green Antenna line device No alarm
faulty/degraded
Blinking Colors (Red, Yellow, Module highlighting (Flexi BTS No alarm
and Green), each color stable SM functionality that can help
for 0.5 second identifying faulty module)
RF Module fan/TX status LED: At least one fan is faulty or -
Red degraded
RF Module fan/TX status LED: All fans are working -
Green
RF Module fan/TX status LED: RF transmission is ON -
Color set according to fan
status, stable
RF Module fan/TX status LED: RF transmission is OFF -
Color set according to fan
status, blinking
g Note: The minimum startup voltage is 40.5 V DC. If the input voltage is below/beyond
extended limits, unit might shut down.
Table 283 FRGU functional specification
Property Value
Output power 6x60 W
MIMO 4TX
Outdoor installation Yes
SW supported technology WCDMA, FDD-LTE
TX frequency range 2110-2170 MHz
RX frequency range 1920-1980 MHz
DL instantaneous bandwidth 60 MHz
UL instantaneous bandwidth 60 MHz
DL filter bandwidth 60 MHz
Descriptions of 6TX RF Modules Flexi Multiradio BTS RF Module and Remote Radio
Head Description
Table 283 FRGU functional specification (Cont.)
Property Value
UL filter bandwidth 60 MHz
Interfaces
Figure 64 FRGU interfaces
ANT 5 ANT3 ANT2 ANT1
RXO3 TX/RX RXO2 TX/RX TX/RX TX/RX
ANT6 ANT4
TX/RX TX/RX RET RXO1
Table 284 FRGU interfaces
Interface Label on the HW Number of Connector type Additional info
interfaces
Power connector DC IN 1 3-pole screw -
terminal
Antenna ANT 6 7/16 -
connector
RF output RxO 3 QMA -
connector
Remote Electrical RET 1 8-pin circular -
Tilt
External Alarm EAC 1 MDR36 -
Connection
Optical interface OPT 3 SFP 1.5 Gbps to 6
Gbps
Flexi Multiradio BTS RF Module and Remote Radio Descriptions of 6TX RF Modules
Head Description
Table 285 FRGU ALD support
ALD support via antenna ports Value
AISG ANT1, ANT3, ANT5, RET: AISG 2.0
Proprietary AISG 1.1 No
CWA (for non-AISG installations) Yes
Voltage ANT1, ANT3, ANT5: 25 V or 12 V
ANT2, ANT4, ANT6: 12 V
RET: 25 V
Power per port 30 W
Figure 65 FRGU functional block diagram
RFModule
Filter
PA
PA Main
TX Bias-T VSWR
TXRF filter
PA Div Tx/Rx
Det
EAC RX
filter
RXRF LNA
RxOUT
RXMain TX Bias-T VSWR
filter
RET RXDiv Tx/Rx
Det
RX
filter
LNA
PA
PA Main
TX Bias-T VSWR
TXRF filter
PA Div Tx/Rx
Det
OpticalIF RX
filter
RXRF LNA
OpticalIF RF RxOUT
control RXMain TX Bias-T VSWR
filter
RXDiv Tx/Rx
Det
RX
OpticalIF filter
LNA
PA
PA Main
TX Bias-T VSWR
TXRF filter
PA Div Tx/Rx
Det
RX
filter
RXRF LNA
RxOUT
RXMain TX Bias-T VSWR
filter
RXDiv Tx/Rx
Det
RX
filter
LNA
DCIN
PSU
Fanassembly
Electrical specifications
Descriptions of 6TX RF Modules Flexi Multiradio BTS RF Module and Remote Radio
Head Description
Table 286 FRGU electrical specifications
Property Value
Nominal supply voltage -48.0 V DC
Nominal input voltage range -40.5 V DC to -57.0 V DC
Extended input voltage range -36.0 V DC to -40.5 V DC
-57.0 V DC to -60.0 V DC
Power consumption
Table 287 FRGU power consumption
Mode Configuration Output power Estimated power consumption [W] at 48VDC
per carrier input at 25°C. Non-committed estimated
[W] values depend on the final product HW and
SW optimization with +/- 10% margin.
Average = (6h low hour load, 10h medium
hour load and 8h busy hour load) / 24h
Power Power Power
consumption consumption consumption
ETSI 202706 ETSI 202706 100% RF
average load busy hour power load
PRRH, static load PBH RRH, P100% RRH
static
Table 288 FRGU installation and mechanical specifications
Property Value
Installation options • floor/stack installation
• pole installation
• wall installation
• 19'' rack/cabinet
IP rating IP65
Related optional items Pole installation
• Flexi Mounting Kit for Floor, Wall and Pole
(FMFA)
• Flexi Pole Kit (FPKA)
• Flexi Pole Kit (FPKC)
• Flexi Module Casing (EMHx)
Flexi Multiradio BTS RF Module and Remote Radio Descriptions of 6TX RF Modules
Head Description
Table 288 FRGU installation and mechanical specifications (Cont.)
Property Value
Floor/Wall installation
• Flexi Mounting Kit for Floor, Wall and Pole
(FMFA)
• Flexi Module Casing (EMHx)
Outdoor 19'' rack
• Flexi Module Casing (EMHx)
Cabinet/indoor 19''' rack
• No optional items needed
Table 289 FRGU dimensions and weight
Property Value Dimensions orientation
Height Core RFM: 115 mm (4.5 in.)
Depth Core RFM: 400 mm (15.7 in.)
Without front covers: 422 mm height
(16.6 in.)
depth
width
With front covers: 560 mm
(22.1 in.)
Width Core RFM: 420 mm (16.5 in.)
Without front covers: 447 mm
(17.6 in.)
With front covers: 492 mm
(19.4 in.)
Weight 24 kg (52.9 lb)
Volume 19.3 l
Environmental specifications
Table 290 FRGU environmental specifications
Property Value
Maximum operational outdoor temperature (at +55°C (131°F)
constant high ambient temperature maximum
output power might be limited)
Minimum operational temperature (including -35°C (-31°F)
cold start)
LEDs
Descriptions of 6TX RF Modules Flexi Multiradio BTS RF Module and Remote Radio
Head Description
Table 291 FRGU LEDs
LED color Description Alarm
Red, stable Critical alarm affecting the Fault
whole RF module or all
antenna carriers
Red, blinking Operation degraded Major/critical alarm
• Major alarm affecting the
whole RF Module
• Major alarm affecting the
whole RF Module
• Major/Critical alarm
affecting a module
subcomponent or antenna
carrier
Flexi Multiradio BTS RF Module and Remote Radio Descriptions of 6TX RF Modules
Head Description
Table 291 FRGU LEDs (Cont.)
LED color Description Alarm
RF Module fan/TX status LED: RF transmission is ON -
Color set according to fan
status, stable
RF Module fan/TX status LED: RF transmission is OFF -
Color set according to fan
status, blinking
g Note: The minimum startup voltage is 40.5 V DC. If the input voltage is below/beyond
extended limits, unit might shut down.
Flexi Multiradio BTS RF Module and Remote Radio Avoiding Passive Intermodulation during RF Module
Head Description and RRH operation
• maximum bandwidth (BW) used for the carriers is more than 0.5 x duplex separation
of the band
• carriers in configuration are wideband in nature (for example WCDMA or LTE), or
combination of wideband and narrow band carriers (for example RF sharing GSM-
WCDMA or GSM-LTE).
• antenna line PIM performance is poor, or not on the required level for the
configuration.
Table 598 Typical reference sensitivity degradation with different Antenna line PIM
performance.
PIM Typical Note
performance degradation
-140 dBc @ 2x43 ~10 dB High degradation, carrier configuration unusable in many
dBm cases
-153 dBc @ 2x43 ~2 dB Modest degradation, tolerable in many cases
dBm
-161 dBc @ 2x43 ~0.2 dB Minimal degradation, however, difficult to reach on the
dBm typical site environment.
When using wideband carrier configurations where PIM products fall into own receiver
band, it is recommended that antenna line PIM performance is at least -153 dBc
measured with 2 x 43dB test signals.
However, this kind of performance might be very difficult to achieve and maintain over
time in outdoor environment due to mechanisms behind the PIM including corrosion,
oxidation, material imperfections, and defects in workmanship. Some of these
parameters might change, and can degrade performance during operation. Taking that
into consideration, it is highly recommended not to use carrier configurations which are
generating intermodulation results in landing in own receiver channels.