Figure 37 FZQE interfaces
DC IN GND MT RET EAC OPT1-2 BF
ANT1-8
Optical IF DAC PA
LNA
ADC/FB
LNA
ADC/RX
DAC PA
RF IC#1
DAC PA
LNA
ADC/FB
DDR2 LNA
ADC/RX
DFE/DSP DAC PA
RF IC#2
Flash ROM
DAC PA
LNA
ADC/FB
LNA
ADC/RX
MCU
DAC PA
RF IC#3
DAC PA
LNA
FPGA
ADC/FB
LNA
ADC/RX
DAC PA
RF IC#4
BF
DC IN
SURGE
RET PSU
Electrical specifications
Table 195 FZQE electrical specifications
Property Value
Nominal supply voltage -48.0 V DC
Nominal input voltage range -40.5 V DC to -57.0 V DC
Extended input voltage range -36.0 V DC to -60.0 V DC
IP rating IP65
height
width
Weight 22 kg (48.5 lbs)
depth
Environmental specifications
Flexi Remote Radio Head 8TX 3500 (FZQE) Flexi Multiradio 10 Base Station TD-LTE RF Module
and Remote Radio Head Description
LEDs
Table 200 FZQE LEDs
LED status Description Alarm
RRH - red, stable A critical alarm has occurred or Critical alarm
a reset is ongoing (red stable
for max. 5 s, then yellow
stable).
RRH - red, blinking A major or minor alarm has Major or minor alarm
occurred.
RRH - yellow, stable Module is on and the status is No alarm
set to ‘waiting’ or ‘blocked’.
RRH - yellow, blinking SW download is in progress or No alarm
configuration is ongoing.
Module is non-operational at
the moment.
RRH - green, stable Module is operational. No alarm
RRH - green, blinking Module is loading software or No alarm
parameters.
RRH OPTx port - green, stable SFP link is connected to the No alarm
System Module or extension
sub-module.
RRH OPTx port - red, stable SFP is installed, but no fiber or No alarm
link is present.
RRH OPTx port - switched off No SFP or SFP power is down. No alarm
RRH TX - green, stable PA power is on. No alarm
RRH TX - green, blinking PA power is off. No alarm
w NOTICE: The RRH should always be mounted in a vertical orientation with connectors
on the bottom side to ensure convection cooling.
g Note: The minimum startup voltage is 40.5 V DC. If the input voltage is below/beyond
extended limits, unit might shut down.