You are on page 1of 33

LTE700 Site Solution

Prepared by Ibrahim Shibli, Tamer Alborhamy


Version-1.
Scope introduction
1. LTE700 Sites will be added with the existing LTE1800 & LTE2100.
2. New CommScope antenna (16 Ports) will be installed and replace all existing antennas.
3. New Huawei antenna (16 Ports) will be installed and replace all existing antennas.
4. In case of Site has Penta antenna installed , will connect L700 only on the new 16 ports
antenna.
5. For L700 collocated with L1800 or L2100 , the existing system module (FSMF MR10) + one Flexi
baseband Extension module (FBBC) will be added for more fibers and baseband capacities.
6. New RF modules (FRPA)will be installed for LTE700.
7. In case of wall mounted sites for LTE1800 & LTE2100 will install 3 RF modules (FRPA) each will
be connected with 1 fiber cable from System module.
LTE FDD700 MOP
Installation Scenario
Scenario 1: Site with LTE1800 or LTE2100 for sharing sites using Octa antenna with 3 sets of installation :
• Set1 : Site installed with 1 LTE700 RF Module.

• Set2 : Site installed with 2 LTE700 RF Module ( 2 Sectors are far from the 3rd sector)

• Set3 : Site installed with 3 LTE700 RF Module ( Wall mount Site )

Scenario 2: Site with LTE1800 or LTE2100 for sharing sites using Huawei antenna with 3 Sets of installation
• Set1 : Site installed with 1 LTE700 RF Module.

• Set2 : Site installed with 2 LTE700 RF Module ( 2 Sectors are far from the 3rd sector)

• Set3 : Site installed with 3 LTE700 RF Module ( Wall mount Site )

Notes to be considered :
• Additional 150 Mbps will be added to the existing Bandwidth of either L1800 or L2100 based on site type.
• 6Gbit fiber cables should be used with 6Gbit SFP.
• Special Pre-fabricated jumpers for Octa antenna will be used (4.3-10 Female).
HW Used in the Project
Flexi Multiradio 10 BTS
Flexi Multiradio 10 System Module outdoor FSMF

High capacity System Module with multi radio capability

• Multi radio platform for GSM, WCDMA, LTE

• Pay as You Grow -capacity expansion with extension sub-


modules (1-2 FBBC)

• Integrated high capacity Ethernet transport

• IP65 Outdoor Module for different installation scenarios and use


cases

• 10.1 – 19.7 kg
• IP65
• -35 to +55 °C
Flexi Multiradio 10 BTS
• Release 3 System Module, FSMF with FBBA and FBBC
• RL40 onwards

Optional power GE or RP3 RF RP3 RF port, RP3 RF port, RP3 RF port, Optional transport sub-
distribution sub- Combo port, OptInt #1 OptInt #2 OptInt #3 module FTIF
module FPFD OptInt #6

Sync In

BB BB
DC out DC in LMP SRIO Ext1 Ext2 GE EAC Sync Out
OPT1 OPT2 OPT3

FBBA FBBC
(RL50) (RL60)

DC in DC out SRIO BB Ext DC in BB Ext RP3 port ( OptInt #4, use in


RL70) or SRIO Combo port
RP3 RF port, OptInt #4 RP3 RF ports
RL70: OptInt #1 (OptInt #1 and #2, RP3 RF port, OptInt #5
use in RL70) RL70: OptInt #3
Flexi Multiradio 10 BTS
Capacity Extension sub-module FBBC

Improved RF unit connectivity with FBBC


• FBBC has the same baseband capacity as FBBA
optional Power optional Transport
• 4 optical ports in FBBC HW (OBSAI RP3 6 Gbps) Distribution sub-module sub-module
• Total 8 ports with FSMF FSMF
FBBC slot for 2nd FBBC

FBBC installation
Connect Power cable from DC outport of FSMF to DC
input on FBBC

Connect FBBC data cable from BBEXT1 on FSMF to BBEXT


on FBBC
FBBC interfaces

-48 VDC input for


power connection

baseband extension
optical OBSAI optical OBSAI optical OBSAI The SRIO/RF4 combo port can be configured to work as fourth RP3-01
baseband extension
RP3-01 6 RP3-01 6 RP3-01 6 interface or as SRIO interface for external baseband extension, for example,
interface towards to connect additional Flexi Multiradio 10 BTS System Module in the future LTE
Gbit/s Gbit/s Gbit/s
System Module SW release.
interfaces interfaces interfaces
(QSFP)
Name Module name SW Support TX RX Obsai Rp-3 Comments
bandwidth* bandwidth*

FRPA Flexi RF Module 6*40W 700 (FRPA) 472703A LTE: RL50 6*TX: 35 MHz 6*RX: 35 MHz 3 x 6 Gb Band 28 (703-738UL & 758-793 DL)
SRAN 16.2 Output power 6 x 40W
6 Gb OBSAI RP3 SFPs:

Sales item Name Length For Notes


472579A FOSH Optical SFP H 850 up to 300 m SM - RFM 6 Gb Multimode SFP
nm 6 Gb 300 m MM 850 nm for OBSAI, two
needed per connection,
LC PC connector
CommScope Antenna 16 ports 4L / 12H – 6 RET
N.B. RET cable should be connected to Antenna Sector (A) and FPRA RF module and detected from LTE700 System module whether its collocated with L1800 or L2100.
All jumpers should be connected according to below standard

Ports distribution /
technology
Technology Color
2300 2300
MHz/RET5 MHz/RET5
2100 1400 700 MHz Green
MHz/RET6 MHz/RET3
900 MHz White
1800 1800
MHz/RET4 MHz/RET4 1400 MHz Gray

1800 MHz Blue

2100 MHz Red


700 MHz/RET1 900 MHz/RET2
2300 MHz Yellow

CommScope_Dat
asheet
RET Labeling for CommScope antenna
N.B. RET cable should be connected to Antenna Sector (A) and FPRA RF module and detected from LTE700 System module whether its collocated with L1800 or L2100.

Each CommScope antenna has 6 RETs and RETs will be labeled according to its Serial Number .
I.e. Sector A antenna has 6 RETs with SN :

RET Sector A RET Sector B RET Sector C


4CM22511 L700 4CM22521 L700 4CM22531 L700
4CM22512 U/G900 4CM22522 U/G900 4CM22532 U/G900
4CM22513 L1400 4CM22523 L1400 4CM22533 L1400
4CM22514 G/L1800 4CM22524 G/L1800 4CM22534 G/L1800
4CM22515 L2300 4CM22525 L2300 4CM22535 L2300
4CM22516 U/L2100 4CM22526 U/L2100 4CM22536 U/L2100

Sector A / SN : 4CM2251 Sector B / SN : 4CM2252 Sector C / SN : 4CM2253


Huawei Antenna 16 ports 4L / 12H – 8 RET
N.B. RET cable should be connected to Antenna Sector (A) and FPRA RF module and detected from LTE700 System module whether its collocated with L1800 or L2100.
All jumpers should be connected according to below standard

Ports distribution /
technology
2300 MHz/Y3 700 MHz Technology Color
/R1
700 MHz Green

900 MHz White

2300 900 1400 MHZ Gray


MHz/Y4 MHz/R2
1800 MHz Blue

2100 MHz Red

2300 MHz Yellow

Huawei_Antenna_
Datashaeet
RET Labeling for Huawei antenna
N.B. RET cable should be connected to Antenna Sector (A) and FPRA RF module and detected from LTE700 System module whether its collocated with L1800 or L2100.

Each Huawei antenna has 8 RETs and RETs will be labeled according to last 2 digits .

RET Sector A RET Sector B RET Sector C


Antenna S/N RET S/N Antenna S/N RET S/N Antenna S/N RET S/N
701273110H9000171 M2731H9017R6637r1 701273110H9000174 M2731H901881925r1 701273110H9000182 M2731H901AN1558r1
701273110H9000171 M2731H9017S64RBy5 701273110H9000174 M2731H9018946RBy5 701273110H9000182 M2731H901AP58RBy5
701273110H9000171 M2731H9017T8838r2 701273110H9000174 M2731H9018A0690r2 701273110H9000182 M2731H901AQ3610r2
701273110H9000171 M2731H9017U79RTy6 701273110H9000174 M2731H9018B16RTy6 701273110H9000182 M2731H901AR43RTy6
701273110H9000171 M2731H9017V92LTy2 701273110H9000174 M2731H9018C41LTy2 701273110H9000182 M2731H901AS81LTy2
701273110H9000171 M2731H9017W50CTy4 701273110H9000174 M2731H9018D15CTy4 701273110H9000182 M2731H901AT60CTy4
701273110H9000171 M2731H9017X90LBy1 701273110H9000174 M2731H9018E26LBy1 701273110H9000182 M2731H901AU90LBy1
701273110H9000171 M2731H9017Y51CBy3 701273110H9000174 M2731H9018F40CBy3 701273110H9000182 M2731H901AV15CBy3

Sector A_Lowest S/N Sector B_Lower S/N Sector C_Highest S/N

Last 2 digits indicates to technology Last 2 digits indicates to technology Last 2 digits indicates to technology
type. type. type.
RET Labeling for Huawei antenna
N.B. RET cable should be connected to Antenna Sector (A) and FPRA RF module and detected from LTE700 System module whether its collocated with L1800 or L2100.

Array number is the last 2 digits in the RET S/N and all RETs should be labeled according to it

Array Technology
R1 L700
R2 G/U900
Y1 G/L1800
Y2 G/L1800
Y3 L2300
Y4 L2300
Y5 L1400
Y6 L/U2100
Antenna S/N RET S/N labeling Antenna S/N RET S/N labeling Antenna S/N RET S/N labeling
701273110H9000171 M2731H9017R6637r1 Sec (A) / L700 701273110H9000174 M2731H901881925r1 Sec (B) / L700 701273110H9000182 M2731H901AN1558r1 Sec (C) / L700

701273110H9000171 M2731H9017S64RBy5 Sec (A) / L1400 701273110H9000174 M2731H9018946RBy5 Sec (B) / L1400 701273110H9000182 M2731H901AP58RBy5 Sec (C) / L1400

701273110H9000171 M2731H9017T8838r2 Sec (A) / G/U900 701273110H9000174 M2731H9018A0690r2 Sec (B) / G/U900 701273110H9000182 M2731H901AQ3610r2 Sec (C) / G/U900

701273110H9000171 M2731H9017U79RTy6 Sec (A) / L/U2100 701273110H9000174 M2731H9018B16RTy6 Sec (B) / L/U2100 701273110H9000182 M2731H901AR43RTy6 Sec (C) / L/U2100

701273110H9000171 M2731H9017V92LTy2 Sec (A) /G/L1800 701273110H9000174 M2731H9018C41LTy2 Sec (B) /G/L1800 701273110H9000182 M2731H901AS81LTy2 Sec (C) /G/L1800

701273110H9000171 M2731H9017W50CTy4 Sec (A) / L2300 701273110H9000174 M2731H9018D15CTy4 Sec (B) / L2300 701273110H9000182 M2731H901AT60CTy4 Sec (C) / L2300

701273110H9000171 M2731H9017X90LBy1 Sec (A) /G/L1800 701273110H9000174 M2731H9018E26LBy1 Sec (B) /G/L1800 701273110H9000182 M2731H901AU90LBy1 Sec (C) /G/L1800

701273110H9000171 M2731H9017Y51CBy3 Sec (A) / L2300 701273110H9000174 M2731H9018F40CBy3 Sec (B) / L2300 701273110H9000182 M2731H901AV15CBy3 Sec (C) / L2300
RET Labeling for Huawei antenna
N.B. RET cable should be connected to Antenna Sector (A) and FPRA RF module and detected from LTE700 System module whether its collocated with L1800 or L2100.

S/N ends with (Y1) it means G/L1800


according to the previous array table

This is the lowest antenna S/N will be


sector (A)
RET Labeling for Huawei antenna
N.B. RET cable should be connected to Antenna Sector (A) and FPRA RF module and detected from LTE700 System module whether its collocated with L1800 or L2100.

BTS_ID : Technology name

Sector number
Example of Jumpers labeling
N.B. RET cable should be connected to Antenna Sector (A) and FPRA RF module and detected from LTE700 System module whether its collocated with L1800 or L2100.

Antenna should be labeled before installation


according to S/N – ascending order – Sector A is the
lowest S/N
i.e. Xxxx1 Sector A
C B A Xxxx2 Sector B
Xxxx3 Xxxx2 Xxxx1 Xxxx3 Sector C
Jumpers labeling standard

All Jumpers should be labeled using Steel tags. And


the labeling process should be according the
following standard :
S : referring to sector #
T : referring to technology
J : referring to Jumper #
900 MHz/RET2

i.e. S : A / T:L700 / J 1 +45


i.e. S : A / T:L700 / J 2 -45
FPFD Power distributer will be installed in FSMF if
not exists and will be used for indoor and outdoor
sites.

FPFD installed in FSMF

FPFD
• Power distribution unit
optional for FSMF MR10
FPFD Flexi Power Distribution for MR10
• Optional PDU to FSMF for Flexi Version Ampacity DC Input Notes
Multiradio10 BTS
.204 40A fix. up to FPCA DC dual cable not
• Integrated to MR10 FSMF core unit 50mm² needed for 240W RFM.
FPCA .203 DC cable
• IP65 protection level needed for 360W RFM
• One DC input and 4+1 DC outputs mode *)

• DC outputs: .103 30A @60V/ up to FPCA DC dual cable not


45A @40V 25mm² needed for 240W RFM/
• 4 outputs mode
• Power interfaces via screw terminal .101 30A fix. up to FPCA DC dual cable
(4…16mm²) .102 25mm² needed for >1100W
loads
• 1 internal output for direct feeding to
FSMF
*) power battery-back up use. Power System low Voltage Load
• OVP Level EN61000-4-5 2kV Disconnect limit and site configuration/ design to be checked in
stacked configuration.
Constant 55V DC operated sites without battery back-up do not
need FPCA.

FPFD Flexi Power Distribution


Flexi Power Module FPMA for outdoor sites
System Overview

• FPMA is a compact Zero footprint outdoor Power System (-35°C…+55°C)


AC/DC Front End Module FPAA
• Does not need air-filter nor air-conditioning
56V /1kW
• Consists of 3U casing, High Efficiency Rectifier and Lithium-Ferrite battery technology Modules

• Suitable for all Flexi BTS installation solutions (wall, pole, mast, stack, cabinet)

• Single FPMA casing can house up to four rectifier/ battery modules

• Scales from 1kW to 8kW rectification in 1kW steps

• Scalable up to 4kW with back-up and support of n+1 redundancy

• High Efficiency Module ~95% @ 230Vac @ 40 – 90% load

• Nominal 230V AC 50Hz


• 1-phase 230V AC, 3-phase star 230V or 3-phase delta 208/240V 60Hz

• Space for optional AC Surge Protector

• Alarm indication for AC failure and module fault detection

Flexi Power Module FPMA


FPAA Flexi AC/DC Submodule (for FPMA)

• Flexi Power AC/DC sub module 230V


• Rectifiers power from 200…240VAC to 55VDC, max. AC current 6A
• Typical efficiency is 95% @ 230VAC with the 40 – 90% load.
• Environmental protection level of IP 65
• Air flow direction adjustable

Back to front airflow Front to back airflow General view of FPAA


Power Consumption

Power consumption / No RF
Number of RF Modules
sharing
1 934
L700 (FRPA)
2 1082
3 1230
4 1640
Installation Guidelines
1. Label all jumpers that are connected to the existing technologies before dismantling to avoid any sectors swap in
case of Roll-back situation.
2. Dismantle all the existing antennas and jumpers from the tower and replace it with the new CommScope antenna
following the azimuth from SCO.
3. Install the new RF module for LTE700 (FPRA) with 2 SFPs.
4. RET cable should be connected to FPRA RF module and detected from LTE700 System module whether its
collocated with L1800 or L2100.
5. In case of outdoor sites , Install the new AC/DC converter FPMA.
6. RF module’s electricity (FPRA) will be derived from FPFD card or from rectifier depends on power options
availability.
7. After installing CommScope antenna , Install all jumpers for all existing technologies ; plus LTE700 as per the color
code.
8. Install FBBC card for LTE1800/2100 system module (FSMF) with 2 SFP for RF connection.
9. connect 2 fibers from system module to RF module (FBBC card OPT1 – RF module OPT1 ) (FBBC card OPT2 – RF
module OPT2 ) in case of 1 RF module is used
10. connect 1 fiber from system module to each RF module (FBBC card OPT1 – RF module1 OPT1 ) (FBBC card OPT2
– RF2 module OPT1 ) in case of 2 RF module is used
11. connect 3 fibers from system module to each RF module (FBBC card OPT1 – RF module1 OPT1 ) (FBBC card
OPT2 – RF module2 OPT1 ) (FBBC card OPT3 – RF module3 OPT1 ) in case of 3 RF module is used
Scenario 1 Site using 1 RF module with 16 ports Antenna

Octa Antenna Octa Antenna Octa Antenna

B
Fiber Optic
C A
If Octa/Huawei antenna will
be installed , all other
Sync cable
antennas will be dismantled
RF Jumper and all technologies will be
migrated to the Octa
antenna
Port 6
FRPA 240W
Port 5 Port 1
OPT 1
Port 2
OPT 2
Port 3
Port 4

FBBC Card
with 4 OPT FBBC/OPT 1
In case of 1 RF Module , 2
Ports FBBC/OPT 2
opt fibers will be connected
to the RF module

LTE1800 or LTE2100 G1800 or U2100


Scenario 1 Site using 2 RF module with 16 ports Antenna

Octa Antenna Octa Antenna Octa Antenna

C B A

Fiber Optic If Octa/Huawei antenna will


Port 6 Port 5
be installed , all other
Sync cable
antennas will be dismantled
RF Jumper FRPA 240W FRPA 240W and all technologies will be
migrated to the Octa
antenna
Port 4 Port 3 Port 2 Port 1

OPT 1 OPT 1

FBBC Card
with 4 OPT
Ports In case of 2 RF Module , 1
opt fiber will be connected
to each RF module
LTE1800 or LTE2100 G1800 or U2100
Scenario 1 Site using 3 RF module with 16 ports Antenna ( Wall-mount)

Octa Antenna Octa Antenna Octa Antenna

C
B A If Octa/Huawei antenna
will be installed , all other
antennas will be
Port 1 Port 2 Port 1 Port 2 Port 1
Port 2
dismantled and all
technologies will be
migrated to the Octa
antenna

FRPA 240W FRPA 240W FRPA 240W

OPT 1 OPT 1
OPT 1
FBBC Card
with 4 OPT In case of 3 RF Module , 1
Ports opt fiber will be
connected to each RF
module
LTE1800 or LTE2100 G1800/U2100
OPT 1
OPT 3
OPT 2
L700 Commissioning

Add 3 New Cells for L700


L700 Commissioning

Assign each cell on RF


module ports with TXRX
usage

Cell 1
Cell 2
Cell 3
L700 Commissioning

Power should be 44.8


dBm / 30.199 Watts
L700 Commissioning

L700 is collocated with


L1800

Use the same Bandwidth and


EARFCN frequency for L700
L700 Commissioning

L700 is collocated with


L2100

Use the same Bandwidth and


EARFCN frequency for L700

You might also like