SEPTIC TANK

NUMBER USERS PER DAY 20 no.

PER CAPITA USE OF WATER 150 LITERS

PROBABLE PEAK DISCHARGE 84 lpm **FORM TABLE 22.4 AS

SLUDGE WITH DRAWEL PER YEAR 360 day's

AVERAGE TEMPERATURE 25 degree

SURFACE AREA 0.92 m^2 / 10 lpm

75 % OF SEWAGE PARTICLE SIZE 0.05 mm

PERCOLATION RATE ADOPTED 0 minuts

SPECIFIC GRAVITY 1.2

LENGTH / BREADTH RATIO 2 TO 4

LENGTH REQUIRED = 3.00

ADOPTED LENGTH / BREADTH RATIO 3

TIME FOR ANAEROBIC DIGETION 65 day's *FROM FIG.22.1

MINIMUM DEPTH OF SEDIMENTATION 0.3 m

FRESH SLUDGE PER CAPITA PER DAY 0.00083 m^3

DIGESTED SLUDGE PER CAPITA PER DAY 0.0002 m^3

FREE BOARD 0.3 m

AVG. VOLUME OF SLUDGE PER CAPITA PER DAY 0.000515 m^3

SURFACE AREA OF TANK 7.728 m^2

MINIMUM DEPTH OF SEDIMENTATION 0.3 m

VOLUME REQUIRED FOR SEDIMENTATION 2.32 m^3

AVG. VOLUME OF SLUDGE 0.7 m^3

VOLUME REQD. FOR SEDIMENTATION DIGETION 1.44 m^3

VOLUME REQD. FOR FREE BOARD 2 m^3


TOTAL VOLUME OF TANK 7 m^3

TOTAL DEPTH OF TANK 0.9 m

BREADTH 1.6 m

LENGTH OF TANK 4.8 m

ADOPTED SIZE OF SEPTIC TAN K= 5 2 1.5 M (LxBxD)

PERCOLATION TRENCHES

TOTAL SOIL SURFACE AREA RQD. #DIV/0! m^2

TOTAL FLOW PER DAY 3000 LITERS

TOTAL AREA OF TRENCH REQUIRED #DIV/0! m^2

ADOPTING TRENCH WIDTH 1 m

SPACING BETWEEN TRENCHES 1 m

TOTAL LAND AREA RQD. #DIV/0! m^2


**FORM TABLE 22.4 ASSUMED 70% OF FIXTURE UNITS IN USE SIMULTANIOUSLY

*FROM FIG.22.1