You are on page 1of 2

HUSKY 100 Aluminium Track

FITTING INSTRUCTIONS - NOTICE DE POSE - MONTAGE HANDLEIDING - MONTAGEANLEITUNG


INSTRUZIONI DI MONTAGGIO - INSTUCCIONES DE MONTAJE

Packer (P)
P 284 Hanger 285 Hanger 280A Track
Face fix
bracket 281A

100kg
88 Max
284 35
80 Min Hanger 55* Max
66 Max
58 Min 47 Min

11
Maximum leaf size Weight Kit No.
13 Min 2700 x 800 x 50mm 100kg H100/15A
20 50 Max 2700 x 950 x 50mm 100kg H100/18A
8.4Ø 20 Min
104P/89
2700 Metal door 2700 x 1050 x 50mm 100kg H100/20A
MAX guide 2700 x 1250 x 50mm 100kg H100/24A
B B 106N/94 17Ø
7 89
25 Channel
5 14 5
10
94X
20 Channel 25
Guide 25
102N
21
B 24 Lug * Measurements based on 3mm metal framing.
B = 20-50mm P = 2 -14 (All dimensions in mm)
Alternative guide arrangements (Not supplied in kit)

ASSEMBLY OF RETAINING STOP, ALTERNATIVE GUIDE FIT HANGER APRON


1 HANGER & TRACK STOP 2 3 4 TO DOOR PANEL
25 x 10g

106N/94 5
14
Min 120

Soft Firm
Clip Tension
Adjustment Not Supplied 94X
7

INSERT HANGERS AND SECURE TRACK FACE & SOFFIT BRACKET AND CLIPSTOP
5 RETAINING STOP 6 7 FIX OPTIONS 8 LOCATIONS
=
Face Fix 50 275 275 275 275 275 50
=
281A
Soffit Fix d
d 287 601H Clipstop
d Track stop
d 281AX
281A
281A 281AX
281A
281AX
Face Fix
Soffit Fix
d = 275

FIT HANGER APRON TO DOOR FIT DOOR POSITION AND


9 PANEL AND ADJUST HEIGHT 10 GUIDE 11 SECURE RETAINING
STOP

P C Henderson Limited, Durham Road, Bowburn, County Durham, DH6 5NG, UK


Telephone: +44(0)191 377 7345 Facsimile: +44(0)191 377 3116 Website: www.pchenderson.com Part No: 664991
E-mail our Technical Department technical@pchenderson.com March 2011 - Issue 4.
HUSKY 100 Steel Track

FITTING INSTRUCTIONS - NOTICE DE POSE - MONTAGE HANDLEIDING - MONTAGEANLEITUNG


INSTRUZIONI DI MONTAGGIO - INSTUCCIONES DE MONTAJE
P
20
281

83 MAX 280 29 100kg


63 MAX 52* MAX
75 MIN 55 MIN
284 44 MIN
285
11 Maximum leaf size Weight Kit No.
8.4Ø 2700 x 800 x 50mm 100kg H100/15
13 2700 x 950 x 50mm 100kg H100/18
MIN
B 2700 x 1050 x 50mm 100kg H100/20
2700 MAX 2700 x 1250 x 50mm 100kg H100/24
7 17Ø 104P/89
14 102N MIN
10

89 Channel
5

B -14
B = 20-50mm P= 24
2 * Measurements based on 3mm metal framing.
Alternative guide arrangement
(Not supplied in kit) (All dimensions in mm)

ASSEMBLY OF RETAINING STOP, ALTERNATIVE GUIDE FIT HANGER APRON


1 HANGER & TRACK STOP 2 3 4 TO DOOR PANEL
25 x 10g

106N/94 5
14 Min 120

Soft Firm
Clip Tension
Adjustment Not Supplied 94X
7

INSERT HANGERS AND SECURE TRACK FACE & SOFFIT BRACKET AND CLIPSTOP
5 RETAINING STOP 6 7 FIX OPTIONS 8 LOCATIONS
=
50 275 275 275 275 275 50
=
38 x 8g
Soffit Fix d
d 287 601H Clipstop
d Track stop
d 281
281
281
281
281 M5 x16
Face Fix
38 x 8g
d = 275

FIT HANGER APRON TO DOOR FIT DOOR POSITION AND


9 PANEL AND ADJUST HEIGHT 10 GUIDE 11 SECURE RETAINING
STOP