Professional Documents
Culture Documents
On-line Analyzers
Process Liquids Process Water
Desalination &
• Treatment baths
Control Room
uted control systems (DCS).
HOST
Remote screen sharing
Plant engineers, maintenance engineers and other authorized
users can remotely take over the analyzer screen (the client)
by means of LAN Ethernet software (such as VNC). Authorized
users can carry out all manual operations and settings from a
remote PC. Conduct trouble-shooting before doing any
physical intervention, grab cross-platform screenshots for
reports or presentations, the possibilities are endless.
4 - 20 mA industry standard
• Results, trendings
• Logs, alarms
• Data graphs • Results, trendings
• Control & simulation of wet parts • Logs, alarms
• Calibration, validation program s • Calibration, validation
• Setup (I/O, communication, • Setup (I/O, communication,
preconditioning) preconditioning)
CLIENT
Screen sharing on
remote desktop
TCP / IP LAN
PROCESS
Scope of supply:
• 10 ¼” incorporated industrial panel PC with excellent • Data logging of 1000 last recorded results
graphics and running AppliTek controller software
• Complete separation between wet part and electronics
• Digital outputs: up to 24 DO (24 VDC) and 6 DO (220 VAC) • Data logging of last 30 titration curves (for titrators)
• Digital inputs: up to 8 DI • Multiple streams (up to 8, application depending)
• Up to 8 analog inputs • ATEX configuration in accordance with 94/9/EC directive
Chemical - Petrochemical
4-tertiary-butylcatechol Acetic acid Acidity Ammonia Bromine Index Caustic Chloride Chlorine
Cyanide Ethyl acetate Fluoride Hardness Hydroxide Hypochlorite Moisture Phenol Silica
Sodium Sodium hydroxide Sulphate Sulphide Sulphuric acid TMAH Total Hydrocarbons
Semiconductor
Acetic acid Ammonia Copper EDTA Fluoride Hydrochloric acid Hydrogen fluoride Hydrogen
peroxide Total and free acid Sulphuric acid
Mining
Acidity Alkalinity Ammonium Aluminium Carbonate Chloride Chromic acid Copper Cyanide
EDTA Hydrochloric acid Iron II Iron III Nickel Silver Sulphuric acid Total Cyanide Zinc
Ion-selective
Ion-selective
Colorimtery
Colorimtery
Methodology Methodology
Titration
Parameter Titration Parameter (continued)
4-tertiary-butylcatechol Hypochlorite
ABC analysis Iron II
Acetic acid Iron III
Acidity Lime
Acid number Magnesium
Acrylonitrile Metabisulphite
Aldehyde Moisture
Alkalinity Na/P molar ratio
Aluminium Nickel
Aluminium chloride Nitrate
Ammonia Nitric acid
Ammonia/Nitrate Oleum
Aniline Ortho-phosphate
Anion active surfactants Oxalic acid
Benzoic acid P&M number
Bicarbonate Peracetic acid
Boric acid Permanganate
Bromine index Peroxide
Calcium Persulphate
Calcium oxide pH
Caprolactam Phenol
Carbonate Phosphate
Carbon oxide Phosphoric acid
Caustic Phthalic acid
Chemical Oxygen Demand Poly vinyl alcohol
Chlorate Potassium
Chloride Potassium hydroxide
Chlorine Potassium iodate
Chromium III Potassium iodide
Chromium VI Redox
Copper Silica
Cyanide Silver
Fatty acids Sodium
Fluoride Sodium hydroxide
Formaldehyde Sodium sulphate
Formic acid Strontium carbonate
Free Chloride Sulphate
Free Cyanide Sulphide
Hardness Sulphite
Hydrazine Sulphonic acid
Hydrochloric acid Sulphuric acid
Hydrogen peroxide Thio cyanate
Hydroquinone TMAH
Hydroxide Tri ethyl amine
Hydroxylamine Tri methyl amine
Zinc
Ion-selective
Ion-selective
Colorimtery
Colorimtery
Methodology Methodology
Titration
Titration
TOTAL parameters COMBINED parameters *
Design - Features
• Titration, colorimetry or ion-selective electrode (ISE) • Ethernet TCP/IP based connection
• Single methodology and single parameter • Reduced down-time by smart features and add-on units
• Straight-forward design, reduced reagent consumption • Data logging of 1000 last recorded results
• High quality sample pump, micropumps, vessel, tubing • Complete wet part - electronics separation
• Incorporated industrial panel PC with AppliTek controller • Available in Ex-proof configuration complying with ATEX or
software NEC500 directives
Ion-selective
Colorimtery
Methodology
Titration
Enclosures - Configurations Parameter
Acetic acid
The EnviroLyzer® Series of On-line Water Analyzers are Acidity
equipped with a new compact dust- and splash-proof Alkalinity
analyzer enclosure consisting of a powder coated steel Aluminium
back, combined with an ergonomic ABS hinged part. Ammonia
Purging with instrument air is possible in case of extreme Bicarbonate
humidity or risk of accumulation of corrosive gases. Biocides
Boron
Where site-specific requirements may compromise the Calcium
analyzer’s potential, optional enclosures/configurations Chloride
are available. If necessary, the analyzer can be integrated Chlorine
in various protective enclosures such as an IP65 rated Chlorine dioxyde
protective cabinet for outdoor use. For hazardous areas, Chlorite
the analyser is integrated in a protective enclosure with Chromium III
all necessary connections, special analytics and control Chromium VI
units, a stand-alone system factory tested to fully meet Color
Copper
ATEX or NEC 500 directives.
Cyanide (free)
Fatty acids
Fluoride
Formaldehyde
Hardness (total)
Hydrazine
Hydrochloric acid
Hydrogen fluoride
Hydroxide
Iron II
Iron III
Magnesium
Manganese
Nickel
Nitrate
Nitrite
Oxalic acid
Permanganate
Phenol
Phosphate
Phosphoric acid
Potassium hydroxide
Silica
Silicium dioxyde
Sodium
Sodium hydroxide
Sodium hypochlorite
Sulphate
Sulphide
Sulphite
Sulphuric acid
Thio cyanate
Total hardness
Urea
Zinc
• True continuous analysis • 5 ¾” color touch screen with buttons for immediate access
• High quality sample, transfer and addition pumps for acid and • Standard auto-cleaning, auto-validation, auto-calibration
persulfate, mass flow meter, dual wavelength IR detector • Data logging of 1000 last recorded results
• Compliant with standard methods USEPA 415.2, ISO 8245 and • Complete wet part / electronics separation
DIN-EN 1484 • Factory configured, tested and calibrated
Trace level determination of heavy metals Measurement of total heavy metal content
VPA® Voltammetric Process Analyzer is a fully automatic Accuracy, precision and stability of results are very critical
on-line analyzer system for the simultaneous determination when monitoring for heavy metal contents in water sam-
of a wide range of hazardous heavy metals in water. The ples by photometric and electrochemical methods. The
whole system consists of an industrial controller, a number VPA® can be equipped with an optional add-on unit to
analytical units (depending on choice of metals), a com- digest organics, while suspended particles can be dissolved
plete sample preparation unit and reagent containers, all completely. The new digestion unit is conform with US EPA
built and enclosed in a floorstanding cabinet. Method 200.2 or 200.7 and processes samples with concen-
trated acids and oxidizing agents at high temperature.
Voltammetry
Colorimetry
Methodology
Parameter
Antimony
Bismuth
Cadmium
Chromium III
Chromium VI
Copper
Iron II
Iron III
Lead
Manganese II
Manganese VII
Mercury
Nickel
Selenium
Silver
Thallium
Tin
Zinc
• Advanced voltammetric principle allowing for high sensitivity • 5 ¾” color touch screen with buttons for immediate access
and low reagent consumption
• Standard auto-calibration / automatic background correction
• Batch operation principle limits loading of the electrode and
• Data logging of 1000 last recorded results
allows to program at will the analysis sequence
• Complete wet part / electronics separation
• Up to three (3) sampling points possible
• Factory configured, tested and calibrated
• Built-in sample pretreating digestion unit (optional)
Reliability
As a specialist manufacturer of on-line analyzers, we are challenged with
offering our customers the best in industrial grade analytics for on-line
monitoring of liquids, from stand-alone analyzers to complete industrial
monitoring systems. All hardware components are carefully selected, with
industrial computers / human interfaces controlling the operation. Results:
massive amounts of process data are reliably measured, logged and com-
municated in a seamlessly easy way to plant managers or control centers.
Flexibility
The incorporated software flexibility minimizes physical operator interven-
tion. The analyzer screen (the client) can remotely be taken over by means
of LAN Ethernet software (such as VNC software). Authorized users can car-
ry out all necessary manual operations and settings from a remote PC using
a modem, internet or intranet connection.
Safety
Standard general purpose zone, optionally conform ATEX or NEC500.
Industrial needs are to be met by industrial solutions. AppliTek can meet
strict regulations for the construction, including materials as well as design
requirements in hazardous locations. On top of that, all automatic features
that come standard with AppliTek on-line analyzers are also included in the
ex-proof design. Special attention is given to wet parts that come in direct
contact with process streams.
Trustability is the currency of exchange between you, the customer, and our
company. A proven track record of 25 years of analytical technology is at
APPLITEK n.v.
NAZARETH BELGIUM
your service. AppliTek’s quality approach is visible in all steps of the delivery
TEL: (32) 9 3863402 FAX: (32) 9 3867297
chain, from the initial design up to quality control. Moreover, the best suited E-mail: team@applitek.com
Responsibility
AppliTek supplies you with the ideal formula for all your needs in process
monitoring. From the application and feasibility study to basic engineering
to the final implementation of the analyzer system, AppliTek is and remains
your single partner. AppliTek’s symbiosis between analytical expertise and
system integration guarantees you a complete solution for a measuring
problem, not merely supply of an analyzer.
AppliTek NV/SA
Industrial Zone « De Prijkels »
Venecoweg 19
B-9810 Nazareth
Belgium
Tel.: +32 9 386 34 02
For USA call: +1-866-417-5887 (toll free)
Fax.: +32 9 386 72 97
E-mail: team@applitek.com
Visit us on www.applitek.com
Follow us on Facebook