Professional Documents
Culture Documents
COHR-DILAS COMPACT-AC PKG PDF
COHR-DILAS COMPACT-AC PKG PDF
Features
Easy-to-integrate CW system features conduction cooled diode laser modules
and consists of a compact 19” (4 HU), rack-mountable chassis and metal-
armoured fiber. Can be combined with DILAS’ processing heads offering
camera and pyrometer options, and allowing the closed-loop operation of the
system in pre-defined temperature ranges for quality relevant applications in
medical device manufacturing and automotive. Available with an optional
fiber-input galvo scanner featuring a field of operation in which the laser spot
can be freely addressed.
Device Specification
200µm Version 400µm Version
Optical Parameters Units
Optical Output Power (CW)
1
W 30 60 90 50 80 110
Stability Over 24-hour (Cooling ΔT = ±1K) % ±2
Wavelength1 nm 808/9801
Wavelength Tolerance1 nm ±10
Pilot Laser
Wavelength nm 650
Output Power mW ≤5
Fiber Parameters
Fiber Connector Type1 SMA
Fiber Length1 m 5
Numerical Aperture NA 0.2
Smallest Fiber Core Diameter 2
µm 200 400
Electrical Parameters
Operating Voltage V 200-240 Single Phase
Frequency Hz 50/60
Power Consumption kVA 0.39 0.39 0.46 0.46 0.46 0.77
Overall Efficiency % >12
Operation Mode CW or Modulated
Modulation Pulse Width (Min. Value) μs 200
Modulation Rise/Fall Time (Min. Value) μs 150
Thermal Parameters
Temperature Ambient in Operation (100% Duty Cycle) °C 15 to 40 (Non-Condensing)
Storage Temperature °C 5 to 50
Mechanical Parameters
Dimension [w x h x d] mm³ 483 x 176 x 500
Weight (Including Water/Air-Chiller) kg 25
Noise Emission dB(A) <70
1
Consult DILAS Industrial Laser Systems for other available options.
2
Additional fiber core diameters available: 300µm, 600µm, 800µm. Larger diameter than listed can be used.
COMPACT Diode Laser System (Air-Cooled)
Package Dimension
Features
- Free standing fiber tip
- High centricity
Device Specification
Parameter Units
Connector Type SMA 905 Both Sides, with Free Standing Fiber Tip.
Ferule Diameter mm 3.167 – 3.172
Outer Diameter (Largest Diameter at Connector) mm 9.5
Cable Diameter mm 7.6
Fiber Length 1
m 2 or 5 ± 0.1
Numerical Aperture NA 0.22 ± 0.02
Core Diameter 1, 2
µm 200 400 600 800
Cladding Diameter 2
µm 280 480 720 880
Centricity µm <6
Long Term Bending Radius (Coil Radius) 3 mm 44 96 144 176
Short Term Bending Radius mm 22 48 72 88
1
Others available upon request.
2
Can differ by ±2%.
3
Minimum value.
Dimensions