0% found this document useful (0 votes)
3K views6 pages

Monorail Beam Design

The document describes the design of a monorail beam with a 4m span. Key details include a flange width of 150mm, yield strength of 245MPa, and a design bending moment of 29kN-m. Calculations show the section has a moment capacity of 123.12kN-m, exceeding the design moment. Deflection is also within limits. A second design is presented for a 5.5m span beam with similar analysis and confirmation of adequate strength and deflection. Both designs are determined to be safe.

Uploaded by

Anand.5
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3K views6 pages

Monorail Beam Design

The document describes the design of a monorail beam with a 4m span. Key details include a flange width of 150mm, yield strength of 245MPa, and a design bending moment of 29kN-m. Calculations show the section has a moment capacity of 123.12kN-m, exceeding the design moment. Deflection is also within limits. A second design is presented for a 5.5m span beam with similar analysis and confirmation of adequate strength and deflection. Both designs are determined to be safe.

Uploaded by

Anand.5
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

Design of Monorail Beam (4m span)

flange width b = 150 mm


flange thick t = 10 mm
overall web depth d = 300 mm 280
web thick tw = 6 mm
Span of the beam L = 4000 mm 4
Monorail beam Capacity W = 25 kN (including hoist weight of 5 kN)
Self weight of beam = 2 kN/m
BM due to crane load (WL/4) M3 = 25 kN-m
BM due to self wt (WL /8)2
M1 = 4 kN-m
Design Bending Moment (M1 + M3) M*m = 29 kN-m
Yield Strenth of Steel fy = 245 N/mm2

Nominal section Moment capacity Ms = fy x Z e


= 156702000 N-mm
= 156.702 kN-m
λef = ((b-tw/2xt) x sqrt(fy/250) = 7.128 < λep as per Table 5.2 of AS 4100
flange is compact
λew = (d-2*t)/tw x sqrt(fy/250) = 46.198 < λep as per Table 5.2 of AS 4100
web is compact
Section Modulus Ze = 639600 mm3

Nominal member moment capacity Mb = αm x αs x Ms

Moment modification factor αm = 1.7M*m


refer clause 5.6.1.1 a(iii) of AS 4100 sqrt((M2)2 + (M3)2 + (M4)2)
= 1.61 less or equal to 2.5
M2 = 12.5
M3 = 25
M4 = 12.5
slenderness reduction factor αs = 0.6 x (sqrt((Ms / Mo)^2+3)-(Ms/Mo))
refer eqn 5.6.1.1 (2) = 0.542

Buckling moment Mo = sqrt((π^2 x E x Iy)/Le^2) x (G x J + (π^2 x E x Iw)/Le^2))


Mo 129.692 KN-m 694578.3 24216309694

Elastic Modulus E = 200000 N/mm2


G = 80000 N/mm2
M.I. about YY axis Iy = 5630040 mm4
M.I. about xx axis Ix = 74076000 mm4
warping constant Iw = 1.18372E+11 mm6 refer appendix H
Torsion constant J = 120160 mm 4
refer appendix H

Effective length le = kt x kl x kr x L refer clause 5.6.3


1 x 1 x 1 x 4000 = 4000 mm

refer clause 5.6.1.1 Mb = 136.791 KN-m


capacity factor φ = 0.9 refer table 3.4
φMs 141.032 KN-m
φMb 123.112 KN-m
Lesser of above values is the section moment capacity
= 123.112 KN-m
Design bending Moment 29 KN-m
Hence Safe

for over hanging (case-2)


overhanging length = 2m 2000
Moment due to crane = 50 KN-m
Moment due to self weight of the beam = 4 KN-m
Design Bending Moment (M1 + M3) M*m = 54 KN-m
hence safe

Check for deflection

allowable deflection d lim, v = Span / 600


= 6.67 mm

Deflection for case - 1 = 2.36 mm 0.112497075 2.249941502

Deflection for case - 2 = 4.77 mm 0.26999298 4.499883003

less than allowable deflection hence safe


Design of Monorail Beam (5.5m span)

flange width b = 200 mm


flange thick t = 12 mm
overall web depth d = 400 mm 376
web thick tw = 8 mm
Span of the beam L = 3000 mm 3
Monorail beam Capacity W = 15 kN (including hoist weight of 5 kN)
Self weight of beam = 3 kN/m
BM due to crane load (WL/4) M3 = 11.25 kN-m
BM due to self wt (WL /8)2
M1 = 3.375 kN-m
Design Bending Moment (M1 + M3) M*m = 14.625 kN-m
Yield Strenth of Steel fy = 245 N/mm2

Nominal section Moment capacity Ms = fy x Z e


= 240382240 N-mm
= 240.382 kN-m
λef = ((b-tw/2xt) x sqrt(fy/250) = 7.920 < λep as per Table 5.2 of AS 4100
flange is compact
λew = (d-2*t)/tw x sqrt(fy/250) = 46.528 < λep as per Table 5.2 of AS 4100
web is compact
Section Modulus Ze = 981152 mm3 (doubt)

Nominal member moment capacity Mb = αm x αs x Ms

Moment modification factor αm = 1.7M*m


refer clause 5.6.1.1 a(iii) of AS 4100 sqrt((M2)2 + (M3)2 + (M4)2)
= 1.80 less or equal to 2.5
M2 = 5.625
M3 = 11.25
M4 = 5.625
slenderness reduction factor αs = 0.6 x (sqrt((Ms / Mo)^2+3)-(Ms/Mo))
refer eqn 5.6.1.1 (2) = 0.862

Buckling moment Mo = sqrt((π^2 x E x Iy)/Le^2) x (G x J + (π^2 x E x Iw)/Le^2))


Mo 739.713 KN-m 3512711 1.5577E+11

Elastic Modulus E = 200000 N/mm2


G = 80000 N/mm2
M.I. about YY axis Iy = 16016042.6666667 mm4
M.I. about xx axis Ix = 216148650.666667 mm4
warping constant Iw = 602779781802.667 mm6 refer appendix H
Torsion constant J = 294570.666666667 mm 4
refer appendix H

Effective length le = kt x kl x kr x L refer clause 5.6.3


1 x 1 x 1 x 4000 = 3000 mm

refer clause 5.6.1.1 Mb = 374.067 KN-m


capacity factor φ = 0.9 refer table 3.4
φMs 216.344 KN-m
φMb 336.660 KN-m
Lesser of above values is the section moment capacity
= 216.344 KN-m
Design bending Moment 14.625 KN-m
Hence Safe

for over hanging (case-2)


overhanging length = 3m 3000
Moment due to crane = 45 KN-m
Moment due to self weight of the beam = 13.5 KN-m
Design Bending Moment (M1 + M3) M*m = 58.5 KN-m
hence safe

Check for deflection

allowable deflection d lim, v = Span / 600


= 5.00 mm

Deflection for case - 1 = 0.22 mm 0.024397272 0.195178179

Deflection for case - 2 = 3.83 mm 0.702641444 3.122850862

less than allowable deflection hence safe