You are on page 1of 5

1.

Work done on 10/7/2018


case 55980 (2h) - Beam bottom bar and tabulated report not tally - Change the way
to obtain the data
case 52028 (1h) - Custom Parameter setting: Beam cover - Implement the custom
cover
case 55849 (1h) - Column Full Report - explain the value
case 55909 (2h) - Wall foundation Pilecap profile error - pilecap grouping issue
case 56024 (2h) - Wall slenderness check: Slab and beam relative stiffness
calculation - debug to get the value

2. Work to do on 11/7/2018
case 56027 (2h) - Raft design: Stay at 90% and will not continue
case 53220 (2h) - New load combination for punching slab checking
case 55983 (2h) - Beam critical region: Dimension
case 56001 (2h) - Beam critical region: Update Tabulated Report for Shear

1. Work done on 11/7/2018


case 56027 (1h) - Raft design: Stay at 90% and will not continue - send the case to
Wang
case 53220 (1h) - New load combination for punching slab checking - not able to
reproducible
case 55983 (2h) - Beam critical region: Dimension - fix the bug in detailing
case 56043 (4h) - BS VS EC Column Moments - pending

2. Work to do on 12/7/2018
case 56043 (4h) - BS VS EC Column Moments
case 56046 (2h) - Raft design result not updated
case 56032 (2h) - Internal Error in Design Slab
case 56001 - Beam critical region: Update Tabulated Report for Shear

1. Work done on 12/7/2018


case 56043 (3h) - BS VS EC Column Moments - explore the Madd calculation
case 56032 (1h) - Internal Error in Design Slab - fixed the exception
case 56046 (3h) - Raft design result not updated - fixed by save the file in plan
base
case 56034 (0.5h) - Esteem.Tests.BatchProcess unit test fails - rebaseline the
result
case 56058 (0.5h) - Esteem.Tests.Slab unit test fails - discovered that it is due
to slab moment value
case 55859 (0.5h) - Pile position - can be adjusted by selecting the wall pile
assignment

2. Work to do on 13/7/2018
case 56043 (2h) - BS VS EC Column Moments - check the minimum k factor
case 56001 (2h) - Beam critical region: Update Tabulated Report for Shear
case 55514 (2h) - DCH Detailing: Column passed but shown as failed
case 55511 (2h) - DCM Detailing: Column summary report error

1. Work done on 13/7/2018


case 56066 (1h): Esteem.Tests.BatchProcess unit test fails - fixed the breaking
code
case 56071 (1h): Esteem.Tests.CBSection unit test fails - fixed the breaking code
case 56069 (1h): Esteem.Tests.RCWallDetailing unit test fails - fixed the breaking
code
case 56043 (2h): BS VS EC Column Moments - change the k value from 1 to 0.1 for
fixed foundation
case 56001 (1.5h): Beam critical region: Update Tabulated Report for Shear (fixed
the bug)
case 55514 (1h): DCH Detailing: Column passed but shown as failed (not
reproducible)

2. Work to do on 16/7/2018
case 55193 (4h): Detailing option for DCM and DCH (beam & column ONLY)
Study on the moment capacity check (2h)
case 56086 (2h): 3D Raft/TransferSlab Contour Steel Area Band Strip Cut for Design

1. Work done on 16/7/2018


case 55193 (4h): Detailing option for DCM and DCH (beam & column ONLY) - fixed the
reporting part (send to Lau for other issue)
case 56043 (4h): BS VS EC Column Moments - beam stiffness multiplies 2 and column
stiffness only considers current column stiffness alone

2. Work to do on 17/7/2018
case 56043 (6h): BS VS EC Column Moments - Explore the beta calculation
case 56035 (2h): Esteem.Tests.BatchProcess unit test fails - revised the beam
torsion design for EC2
case 56114 (2h): Pile footing report: Check for pile load
case 56085 (2h): 2D Slab Contour Steel Area Band Strip Cut for Design : study the
implementation for the design

1. Work done on 17/7/2018


case 56043 (6h): BS VS EC Column Moments - Explore the beta calculation - done and
implement the revised rlative stiffness calculation to wall, check the limit for BS
and EC2. BS will 0.4 and EC2 will be 0.1, compare the wall beta value between
BS8110 and EC2
case 56035 (2h): Esteem.Tests.BatchProcess unit test fails - revised the beam
torsion design for EC2 - implemented

2. Work to do on 18/7/2018
case 56139 (2h): Esteem.Tests.CodeCommon unit test fails - due to relative stiffnes
set to 0.4
case 56114 (2h): Pile footing report: Check for pile load - output checking
case 56132 (2h): Beam shear and torsion failed: Section near column support -
result checking
case 56134 (2h): Unable to re-open Raft design result - file saving problem
case 55193 (2h): Detailing option for DCM and DCH (beam & column ONLY) - critical
region dimension issue

1. Work done on 18/7/2018


case 56132 (1h): Unable to re-open Raft design result - send to Wang for checking -
due to meshData3D deserialize error
case 56139 (1h): Esteem.Tests.CodeCommon unit test fails - remove the 0.4 checking
for BS 8110
case 56043 (2h): BS VS EC Column Moments - remove the 0.4 checking for BS 8110 and
multiplication of 2 only applicable to beam and slab, add in reference note and
check the k = 10 for slab
case 56114 (1.5h): Pile footing report: Check for pile load - round up the pile
length value
case 56147 (2h): Top element stiffness calculation for wall - BS 8100 - revised the
specification which the Min(kTW, kB) only applicable if one end of the wall is
restrained by the beam and the other end of the wall restrained by the wall.

2. Work to do on 19/7/2018
case 56043 (2h): BS VS EC Column Moments - follow up
case 55193 (4h): Detailing option for DCM and DCH (beam & column ONLY)
case 52028 (2h): Custom Parameter setting: Beam cover - updated the code

1. Work done on 19/7/2018


case 56043 (2h): BS VS EC Column Moments - close
case 52028 (1h): Custom Parameter setting: Beam cover - done
case 56162 (2h): unable design pilecap - governed by moment which induced by pile
spacing
case 56172 (2h): Raft not design - design the raft column even with edge beam
case 56171 (2h): Raft slab design exception - fixed the exception

2. Work to do on 20/7/2018
case 56172 (2h): Raft not design
case 56023 (4h): Parameter usage of TBeamEffect and BeamStiffInc
case 56176 (2h): Raft, slab, flat slab Detailing based on Steel area contour

1. Work done on 20/7/2018


case 56043 (2h): BS VS EC Column Moments - modify the layout in order to make the
column pass
case 56172 (3h): Raft not design - remove the checking of beam
case 55980 (3h): Beam bottom bar and tabulated report not tally
case 56176 (1h): Raft, slab, flat slab Detailing based on Steel area contour -
create a button for band strip cut detailing

2. Work to do on 23/7/2018
case 55193 (3h): Detailing option for DCM and DCH (beam & column ONLY)
case 56147 (1h): Top element stiffness calculation for wall - BS 8110
case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour

1. Work done on 23/7/2018


case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour -
create a button and create data class to keep the As value
case 55193 (1h): Detailing option for DCM and DCH (beam & column ONLY) -
implemented the critical region length computation in the report
case 56147 (2h): Top element stiffness calculation for wall - BS 8110 -
implemented, multiplication of 2 only applied to slab and transverse beam
case 56172 (1.5h): Raft not design - provide a replacement method for
Esteem.Slab.Raft.RaftDesign.GetColumnCount(prj)
cas e56209 (1h): Raft failure message not tally with failed element list - fixed

2. Work to do on 24/7/2018
case 51101 (2h): Column Design Report for DCM Selected - Exception thrown when open
column full report
case 56023 (2h): Parameter usage of TBeamEffect and BeamStiffInc - check the Ec
usage
case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour -
create a button and create data class to keep the As value

1. Work done on 24/7/2018


case 56023 (2h): Parameter usage of TBeamEffect and BeamStiffInc - check the Ec
usage (use the original Ec)
case 56172 (2h): check the code to ensure RaftDesign class is not used in raft slab
design
case 51101 (2h): Column Design Report for DCM Selected - Exception thrown when open
column full report - fixed
case 56176 (2h): Raft, slab, flat slab Detailing based on Steel area contour -
create data class for the object who intersect with the cut line
2. Work to do on 25/7/2018
case 56176 (6h): Raft, slab, flat slab Detailing based on Steel area contour -
create data class for the object who intersect with the cut line (continue)
case 56230 (2h): Seismic EC8: capacity check (for checking purpose)

1. Work done on 25/7/2018


case 56172 (0.5h): Raft not design - fixed breaking code
case 56043 (0.5h): BS VS EC Column Moments - change the epsilon method to symbol, >
case 56176 (7h): Raft, slab, flat slab Detailing based on Steel area contour -
create data class for the object who intersect with the cut line (continue)

2. Work to do on 26/7/2018
case 56176 (7h): Raft, slab, flat slab Detailing based on Steel area contour
case 56230 (1h): Seismic EC8: capacity check (for checking purpose) - study the
specification

1. Work done on 26/7/2018


case 56172 (1.5h): raft not design: revised the IsColumnWithinOnSlabs() method
case 56238 (1.5h): fixed the raftslab design report
case 56242 (1.5h): Critical region length: Tapered beam - fixed
case 56176 (6h): Raft, slab, flat slab Detailing based on Steel area contour

2. Work to do on 27//2018
case 54573 (2h): Pad footing detailing comments from Ir Anthony
case 54618 (2h): Revise flexural shear check for pile cap design
case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour

1. Work done on 27/7/2018


case 54573 (2h): Pad footing detailing comments from Ir Anthony - change the
lapping dimension style
case 54618 (2h): Revise flexural shear check for pile cap design - fixed
case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour -
create the raftslab span class

2. Work to do on 30//2018
case 53068 (2h): Raft Punching Shear Design for Floor based slab - result
verification
case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour -
create the raftslab span class

1. Work done on 30/7/2018


case 53068 (2h): Raft Punching Shear Design for Floor based slab - result
verification
case 56277 (2h): Lot 61643 bungalow - fixed the combined footing bug case, does
not consider back fill soil load

2. Work to do on 31/7/2018
case 53068 (1h): Raft Punching Shear Design for Floor based slab - result
verification - done
case 56254 (2h): Critical region detailing not shown - fixed
case 56147 (1h): Top element stiffness calculation for wall - fixed
case 56176 (6h): Raft, slab, flat slab Detailing based on Steel area contour -
create the raftslab span class

1. Work done on 31/7/2018


case 53068 (1h): Raft Punching Shear Design for Floor based slab - result
verification - done
case 56254 (2h): Critical region detailing not shown - fixed
case 56147 (1h): Top element stiffness calculation for wall - fixed
case 56176 (6h): Raft, slab, flat slab Detailing based on Steel area contour -
create the raftslab span class

2. Work to do on 1/8/2018
case 56176 (8h): Raft, slab, flat slab Detailing based on Steel area contour -
create the raftslab span class

1. Work done on 1/8/2018


case 56298 (1h): Program hangs when run slab design with P-delta = True - fixed the
index issue
case 56300 (2h): Click on Beam tabulated report will have an exception - fixed
case 56176 (5h): Raft, slab, flat slab Detailing based on Steel area contour -
create the raftslab span class

2. Work to do on 2/8/2018
case 56176 (8h): Raft, slab, flat slab Detailing based on Steel area contour -
create the raftslab span class

1. Work done on 2/8/2018


case 56147 (1h): Top element stiffness calculation for wall - BS 8110
case 56176 (8h): Raft, slab, flat slab Detailing based on Steel area contour

2. Work to do on 3/8/2018
case 56175 (2h): Column drop profile overlap with beam
case 56176 (6h): Raft, slab, flat slab Detailing based on Steel area contour

1. Work done on 3/8/2018


case 56176 (5h): Raft, slab, flat slab Detailing based on Steel area contour - done
the column drop detailing
case 54573 (2h): Pad footing detailing comments from Ir Anthony - top bar diameter,
top bar spacing and top bar reinforcement strength

2. Work to do on 6/8/2018
case 56175 (4h): Column drop profile overlap with beam
case 56172 (2h): Raft not design
case 56176 (2h): Raft, slab, flat slab Detailing based on Steel area contour

1. Work done on 6/8/2018


case 56175 (4h): Column drop profile overlap with beam - synchronise the checking
with the raft slab design
case 56172 (2h): Raft not design - fixed the detailing issue
case 55193 & 56323 (2h): New Parameter: Seismic Detailing Style and Detailing
option for DCM and DCH (beam & column ONLY) - Point the parameter to
SeismicDetailingStyle

2. Work to do on 8/8/2018
case 56350 (6h): study on flat slab design
case 56230 (2h): Seismic EC8: capacity check (for checking purpose)