You are on page 1of 66

EBARA Submersible Sewage Pumps DLFU

Contents
Project: Model: Chk’d: Date:
Model DLFU 100DLFU61.5 100DLFU637 250DLFU611
100DLFU62.2 100DLFU645 250DLBFU615
50DLFU61.5 100DLMFU62.2 150DLFU67.5 250DLCFU615
80DLFU61.5 100DLFU63.7 150DLFU611 250DLFU618
80DLMFU61.5 100DLMFU63.7 150DLFU615 250DLFU622
80DLFU62.2 100DLFU65.5 150DLFU618 250DLFU630
80DLMFU62.2 100DLMFU65.5 150DLFU622 250DLFU637
80DLFU63.7 100DLFU67.5 150DLFU630 250DLFU645
80DLMFU63.7 100DLMFU67.5 150DLFU637 300DLFU618
80DLFU65.5 100DLFU611 150DLFU645 300DLFU622
80DLMFU65.5 100DLMFU611 200DLFU67.5 300DLFU630
80DLFU67.5 100DLFU615 200DLFU611 300DLFU637
80DLCMFU67.5 100DLMFU615 200DLFU615 300DLFU645
80DLFU611 100DLFU618 200DLFU618
80DLCMFU611 100DLMFU618 200DLFU622
80DLFU615 100DLFU622 200DLFU630
80DLFU618 100DLMFU622 200DLFU637
80DLFU622 100DLFU630 200DLFU645

Section Page

Specifications 2-158
Selection Chart 2-165
Performance Curves 2-166
Outline Drawings 2-191
Sectional View 2-210
QDC Information 2-278
Technical Information 2-289.1
material specification
impeller description
motor protection
cable entry
paint specifications
mechanical seal
general
Motor Data 2-315.1
motor electrical specifications
cable data
wiring diagrams
motor electrical data

EBARA Fluid Handling


www.pumpsebara.com 2-155
(t) 803 327 5005 • (f) 803 327 5097 rev. 11/02
EBARA Submersible Sewage Pumps DLFU
Contents
Project: Model: Chk’d: Date:

EBARA Fluid Handling


www.pumpsebara.com 2-156
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Model Designation
Project: Model: Chk’d: Date:

DLF/
100 DLMF
U 6 1.5 2

DISCHARGE SIZE – mm
50mm – 2" 200mm – 8"
80mm – 3" 250mm – 10"
100mm – 4" 300mm – 12"
150mm – 6"

MODEL TYPE
DLF/DLMF – submersible sewage pump
DLFM/DLMFM – FM explosion proof designation

GEOGRAPHIC DESIGNATION
U – U.S.A. market

HERTZ
6 - 60

RATED KW
1.5 – 2HP 7.5 – 10HP 22 – 30HP
2.2 – 3HP 11 – 15HP 30 – 40HP
3.7 – 5HP 15 – 20HP 37 – 50HP
5.5 – 71/2HP 18 – 25HP 45 – 60HP

PHASE
none – three phase

VOLTAGE
2 - 208/230
4 - 460
5 - 575

EBARA Fluid Handling


www.pumpsebara.com 2-157
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Specifications
Project: Model: Chk’d: Date:
Model DLFU
Specifications

Standard Optional

Size 2, 3, 4, 6, 8, 10, 12 inch

Range of HP 2 to 60 HP
Range of Performance Capacity 13 to 4000 GPM
Head 7 to 243 feet
Limitation
Maximum Water Temperature 104°F ( 40°C)
Synchronous Speed 1800 RPM
Materials
Casing Cast Iron
Impeller Cast Iron (2 to 60HP)
Ductile Iron (150-300 DLFU 40 to 60 HP)
Shaft 403 Stainless Steel (2 to 5HP)
420 Stainless Steel (71/2 to 60HP)
Motor Frame Cast Iron
Fastener 304 Stainless Steel
Mechanical Seal Double Mechanical Seal
Material – Upper Side Carbon/Ceramic (2 to 60HP) Tungsten Carbide/Tungsten Carbide
Material – Lower Side Silicon Carbide/Silicon Carbide (2 to 60HP) Tungsten Carbide/Tungsten Carbide
Tungsten Carbide/Tungsten Carbide (150-300 DLFU
50 and 60HP only)
Impeller Type Semi-open (2 to 30HP)
Enclosed (40 to 60HP)
Bearing Prelubricated Ball Bearing
Motor Insulation Class F (2-5HP), H (71/2 to 60HP) FM Explosion Proof, Class 1,
Three Phase 208/230/460V Division 1, Group C, D
Service Factor 1.15
Motor Protection Thermal Detector – Klixons
Mechanical Seal Leakage Detector – Float Switch
Submersible cable 33 ft. (2 to 5HP) ____ ft. (customer specified)
50 ft. (71/2 to 60HP)
Accessories QDC System

EBARA Fluid Handling


www.pumpsebara.com 2-158
(t) 803 327 5005 • (f) 803 327 5097 rev. 02/13
EBARA Submersible Sewage Pumps DLFU
Specifications
Project: Model: Chk’d: Date:
A. General:
Provide submersible sewage pumps suitable for continuous duty operation underwater without loss of watertight
integrity to a depth of 65 feet. Pump system design shall include a guide rail system be such that the pump will be
automatically connected to the discharge piping when lowered into place on the discharge connection. The pump
shall be easily removable for inspection or service, requiring no bolts, nuts, or other fasteners to be disconnected, or
the need for personnel to enter the wet well. The motor and pump shall be designed, manufactured, and assembled
by the same manufacturer.

B. Manufacturer:
EBARA International Corporation

C. Pump Characteristics:
Pumps shall conform to the following requirements:

Number of units
Design flow (gpm)
Design TDH (ft)
Minimum shut off head (ft)
RPM 1800
Maximum HP
Minimum efficiency at design (%)
Minimum power factor at design (%)
Voltage/HZ 208/230V, 460V / 60
Phase 3

D. Pump Construction:
All major parts of the pumping unit(s) including casing, impeller, suction cover, wear rings, motor frame and discharge
elbow shall be manufactured from gray cast iron, ASTM A-48 Class 30. Castings shall have smooth surfaces devoid
of blow holes or other casting irregularities. Casing design shall be centerline discharge with a large radius on the
cut water to prevent clogging. Units shall be furnished with a discharge elbow and 125 lb. flat face ANSI flange. All
exposed bolts and nuts shall be 304 stainless steel. All mating surfaces of major components shall be machined and
fitted with NBR o-rings where watertight sealing is required. Machining and fitting shall be such that sealing is
accomplished by automatic compression of o-rings in two planes and o-ring contact is made on four surfaces without
the requirement of specific torque limits. Internal and external surfaces are prepared to SPPC-VISI-SP-3-63 then
coated with a zinc-chromate primer. The external surfaces are then coated with a H.B. Teneme-Tar 46H-413 Polyamide
Epoxy - Coal Tar paint

1. Impellers:
a. For units 2 to 5 HP, the impeller shall be radial single or multi-vane, semi-open design. It shall be dynamically
balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the
impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might
otherwise clog the pump. The 2 to 5 HP impeller design shall also include back pump out vanes to reduce the
pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located
behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct
connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include
a replaceable cast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintain
working clearances and hydraulic efficiencies.

b. For units 71/2 to 30 HP, the impeller shall be a mixed flow multi-vane semi-open design. It shall be dynamically
balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the
impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might
otherwise clog the pump. The 71/2 to 30 HP impeller design shall also include back pump out vanes to reduce the
pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located
behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct

EBARA Fluid Handling


www.pumpsebara.com 2-159
(t) 803 327 5005 • (f) 803 327 5097 rev. 10/11
EBARA Submersible Sewage Pumps DLFU
Specifications
Project: Model: Chk’d: Date:
connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include
a replaceable cast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintain
working clearances and hydraulic efficiencies.

c. For high head units with 4'' discharge, 40 to 60 HP shall have a radial multi-vane, enclosed impeller design. It
shall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns.
The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release
of objects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce the
entry of foreign materials into the mechanical seal area. Impellers shall be direct connected to the motor shaft
with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable casing wear
ring at the pump suction to maintain working clearances and hydraulic efficiencies.

d. For units 6'' to 12'' discharge sizes, 40 to 60 HP, the impeller shall be a mixed flow multi-vane enclosed design. It
shall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns.
The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release
of objects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce the
entry of foreign materials into the seal area. Impellers shall be direct connected to the motor shaft with a slip fit,
key driven, and secured with an impeller bolt. The design shall include a replaceable casing wear ring at the
pump suction to maintain working clearances and hydraulic efficiencies.

optional K-series design:


e. For units 2 to 5 HP, the impeller shall be radial single or multi-vane, semi-open design. It shall be dynamically
balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the
impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might
otherwise clog the pump. The 2 to 5 HP impeller design shall also include back pump out vanes to reduce the
pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located behind
the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct connected
to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable
cast iron suction cover. The suction cover shall contain a groove(s) perpendicular to the suction opening to disrupt
fibrous solids that may otherwise become lodged between the impeller and suction cover. The suction cover shall
be designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies.

f. For units 71/2 to 30 HP, the impeller shall be a mixed flow multi-vane semi-open design. It shall be dynamically
balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the
impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might
otherwise clog the pump. The 71/2 to 30 HP impeller design shall also include back pump out vanes to reduce the
pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located
behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct
connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include
a replaceable cast iron suction cover. The suction cover shall contain a groove(s) perpendicular to the suction opening
to disrupt fibrous solids that may otherwise become lodged between the impeller and suction cover.The suction
cover shall be designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies.

2. Mechanical Seals
a. For units 2 to 5 HP, double mechanical seals operating in an oil bath shall be provided on all units. The oil filled
seal chamber shall be designed to prevent over-filling and include an anti-vortexing vane to insure proper lubrication
of both seal faces. Lower face materials shall be silicon carbide, upper faces carbon vs. ceramic, NBR elastomers,
and 304SS hardware. Seal system shall not rely on pumping medium for lubrication.

b. Units 71/2 to 60 HP shall be designed to include a double mechanical seal in a tandem arrangement. Each seal
shall be positively driven and act independently with its own spring system. The upper seal operates in an oil
bath, while the lower seal is lubricated by the oil from between the shaft and the seal faces, and in contact with

EBARA Fluid Handling


www.pumpsebara.com 2-160
(t) 803 327 5005 • (f) 803 327 5097 rev. 10/11
EBARA Submersible Sewage Pumps DLFU
Specifications
Project: Model: Chk’d: Date:
the pumpage. The oil filled seal chamber shall be designed to prevent over-filling and include an anti-vortexing
vane to insure proper lubrication of both seal faces. Lower face materials shall be silicon carbide (tungsten carbide
for 150-300 DLF 50 & 60 HP only), upper faces carbon vs. ceramic, NBR elastomers, and 304SS hardware. Seal
system shall not rely on pumping medium for lubrication.

E. Motor Construction:
The pump motor shall be an air filled induction type with a squirrel cage rotor, shell type design, built to NEMA MG-1,
Design B specifications. Stator windings shall be copper, insulated with moisture resistant Class H insulation, rated
for 356°F. The stator shall be dipped and baked three times in Class H varnish and heat shrunk fitted into the stator
housing. Rotor bars and short circuit rings shall be manufactured of cast aluminum. Motor shaft shall be one piece
AISI403 for 2 to 5 HP, AISI420 for 71/2 to 60 HP, rotating on two permanently lubricated ball bearings designed for a
minimum B-10 life of 60,000 hours. Motor service factor shall be 1.15 and capable of up to 20 starts per hour. The
motor shall be designed for continuous duty pumping at a maximum sump temperature of 104°F. Voltage and
frequency tolerances shall be a maximum 10 / 5% respectively. Motor over temperature protection shall be provided
by miniature thermal protectors embedded in the windings. Mechanical seal failure protection shall be provided by a
mechanical float switch located in a chamber above the seal. This switch shall be comprised of a magnetic float that
actuates a dry reed switch encapsulated within the stem. Should the mechanical seal fail, liquid shall be directed
into the float chamber, in which the rising liquid activates the switch opening the normally closed circuit. For units 2
to 30 HP the float body and float shall be a polypropylene material with a 316SS stopper. Units 40 HP and greater,
the float switch components shall be 304SS. The motor shall be non-overloading over the entire specified range of
operation and be able to operate at full load intermittently while unsubmerged without damage to the unit.

Power cable jacket shall be manufactured of an oil resistant chloroprene rubber material, designed for submerged
applications. Cable shall be watertight to a depth of a least 65'. The cable entry system shall comprise of primary,
secondary, and tertiary sealing methods. The primary seal shall be achieved by a cylindrical elastomeric grommet
compressed between the motor cover and a 304SS washer. Secondary sealing is accomplished with a compressed
o-ring made of NBR material. Compression and subsequent sealing shall preclude specific torque requirements. The
system shall also include tertiary sealing to prevent leakage into the motor housing due to capillary action through the
insulation if the cable is damaged or cut. The cable wires shall be cut, stripped, re-connected with a copper butt end
connector, and embedded in epoxy within the cable gland. This provides a dead end for leakage through the cable
insulation into the motor junction area. The cable entry system shall be the same for both the power and control cables.

F. Guide Rail system:


Design shall include two (2) 304SS schedule 40 guide rails sized to mount directly to the quick discharge connector,
QDC, at the floor of the wetwell and to a guide rail bracket at the top of the wetwell below the hatch opening, (refer
to project drawings). Intermediate guide brackets are recommended for rail lengths over 15 feet.

Guide rails are not part of the pump package and shall be supplied by others.

The QDC shall be manufactured of cast iron, ASTM A48 Class 30. It shall be designed to adequately support the
guide rails, discharge piping, and pumping unit under both static and dynamic loading conditions with support legs
that are suitable for anchoring it to the wetwell floor. The face of the inlet QDC flange shall be perpendicular to the
floor of the wetwell. The discharge flange of the QDC shall conform to ANSI B16.1 Class 125.

The pump design shall include an integral self-aligning sliding bracket. Sealing of the pumping unit to the QDC shall
be accomplished by a single, linear, downward motion of the pump. The entire weight of the pump unit shall be guided
to and wedged tightly against the inlet flange of the QDC, making metal to metal contact with the pump discharge
forming a seal without the use of bolts, gaskets or o-rings.

A stainless steel lifting chain of adequate length for removing and installing the pump unit is recommended. The chain
shall have a round link with a 2-1/4'' inside diameter every two feet. This link will allow for a sliding pinch bar through
the link to pick the chain, more than once if necessary, at multiple intervals during pump removal and installation.

EBARA Fluid Handling


www.pumpsebara.com 2-161
(t) 803 327 5005 • (f) 803 327 5097 rev. 10/11
EBARA Submersible Sewage Pumps DLFMU–Explosion Proof Non-clog
Specifications
Project: Model: Chk’d: Date:
A. General:
Provide FM explosion proof submersible non clog sewage pumps suitable for continuous duty operation underwater
without loss of watertight integrity to a depth of 65 feet. Pump system design shall include a guide rail system be
such that the pump will be automatically connected to the discharge piping when lowered into place on the dis-
charge connection. The pump shall be easily removable for inspection or service, requiring no bolts, nuts, or other
fasteners to be disconnected, or the need for personnel to enter the wet well. The motor and pump shall be
designed, manufactured, and assembled by the same manufacturer.

B. Manufacturer:
EBARA International Corporation

C. Pump Characteristics:
Pumps shall conform to the following requirements:

Number of units
Design flow (gpm)
Design TDH (ft)
Minimum shut off head (ft)
RPM 1800
Maximum HP
Minimum efficiency at design (%)
Minimum power factor at design (%)
Voltage/HZ 208/230V, 460V / 60
Phase 3

D. Pump Construction:
All major parts of the pumping unit(s) including casing, impeller, suction cover, wear rings, motor frame and discharge
elbow shall be manufactured from gray cast iron, ASTM A-48 Class 30. Castings shall have smooth surfaces devoid
of blow holes or other casting irregularities. Casing design shall be centerline discharge with a large radius on the
cut water to prevent clogging. Units shall be furnished with a discharge elbow and 125 lb. flat face ANSI flange. All
exposed bolts and nuts shall be 304 stainless steel. All mating surfaces of major components shall be machined and
fitted with NBR o-rings where watertight sealing is required. Machining and fitting shall be such that sealing is
accomplished by automatic compression of o-rings in two planes and o-ring contact is made on four surfaces without
the requirement of specific torque limits. Internal and external surfaces are prepared to SPPC-VISI-SP-3-63 then coated
with a zinc-chromate primer. The external surfaces are then coated with a H.B. Teneme-Tar 46H-413 Polyamide
Epoxy - Coal Tar paint.

1. Impellers:
a. For units 2 to 5HP, the impeller shall be single or radial multi-vane, semi-open design. It shall be dynamically balanced
and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the impeller
vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might otherwise
clog the pump. The 2 to 5 HP impeller design shall also include back pump out vanes to reduce the pressure and
entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located behind the impeller
hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct connected to the
motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable
cast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintain working
clearances and hydraulic efficiencies.

b. For units 71/2 to 30 HP, the impeller shall be a mixed flow multi-vane semi-open design. It shall be dynamically
balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the
impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might
otherwise clog the pump. The 71/2 to 30 HP impeller design shall also include back pump out vanes to reduce the
pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located
behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct

EBARA Fluid Handling


www.pumpsebara.com 2-162
(t) 803 327 5005 • (f) 803 327 5097 rev. 10/11
EBARA Submersible Sewage Pumps DLFMU–Explosion Proof Non-clog
Specifications
Project: Model: Chk’d: Date:
connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include
a replaceable cast iron suction cover. The suction cover shall be designed such that it may be adjusted to maintain
working clearances and hydraulic efficiencies.

c. For high head units, 4'' discharge, 40 to 60 HP shall have a radial multi-vane, enclosed impeller design. It shall
be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns. The
inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of
objects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce the entry
of foreign materials into the mechanical seal area. Impellers shall be direct connected to the motor shaft with a
slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable casing wear ring at
the pump suction to maintain working clearances and hydraulic efficiencies.

d. For units 6'' to 12'' discharge sizes, 40 to 60 HP, the impeller shall be a mixed flow multi-vane enclosed design. It
shall be dynamically balanced and shall be designed for solids handling with a long thrulet without acute turns.
The inlet edge of the impeller vanes shall be angled toward the impeller periphery so as to facilitate the release
of objects that might otherwise clog the pump. A lip seal shall be located behind the impeller hub to reduce the
entry of foreign materials into the seal area. Impellers shall be direct connected to the motor shaft with a slip fit,
key driven, and secured with an impeller bolt. The design shall include a replaceable casing wear ring at
the pump suction to maintain working clearances and hydraulic efficiencies.

optional K-series design:


e. For units 2 to 5HP, the impeller shall be single or radial multi-vane, semi-open design. It shall be dynamically balanced
and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the impeller
vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might otherwise
clog the pump. The 2 to 5 HP impeller design shall also include back pump out vanes to reduce the pressure and
entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located behind the impeller
hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct connected to the
motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include a replaceable
cast iron suction cover. The suction cover shall contain a groove(s) perpendicular to the suction opening to disrupt
fibrous solids that may otherwise become lodged between the impeller and suction cover. The suction cover shall
be designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies.

f. For units 71/2 to 30 HP, the impeller shall be a mixed flow multi-vane semi-open design. It shall be dynamically
balanced and shall be designed for solids handling with a long thrulet without acute turns. The inlet edge of the
impeller vanes shall be angled toward the impeller periphery so as to facilitate the release of objects that might
otherwise clog the pump. The 71/2 to 30 HP impeller design shall also include back pump out vanes to reduce the
pressure and entry of foreign materials into the mechanical seal area. In addition, a lip seal shall be located
behind the impeller hub to further reduce the entry of foreign materials into the seal area. Impellers shall be direct
connected to the motor shaft with a slip fit, key driven, and secured with an impeller bolt. The design shall include
a replaceable cast iron suction cover. The suction cover shall contain a groove(s) perpendicular to the suction opening
to disrupt fibrous solids that may otherwise become lodged between the impeller and suction cover. The suction
cover shall be designed such that it may be adjusted to maintain working clearances and hydraulic efficiencies.

2. Mechanical Seals
a. For units 2 to 5 HP, double mechanical seals operating in an oil bath shall be provided on all units. The oil filled
seal chamber shall be designed to prevent over-filling and include an anti-vortexing vane to insure proper lubrication
of both seal faces. Lower face materials shall be silicon carbide, upper faces carbon vs. ceramic, NBR elastomers,
and 304SS hardware. Seal system shall not rely on pumping medium for lubrication.

b. Units 71/2 to 60 HP shall be designed to include a double mechanical seal in a tandem arrangement. Each seal
shall be positively driven and act independently with its own spring system. The upper seal operates in an oil
bath, while the lower seal is lubricated by the oil from between the shaft and the seal faces, and in contact with

EBARA Fluid Handling


www.pumpsebara.com 2-163
(t) 803 327 5005 • (f) 803 327 5097 rev. 10/11
EBARA Submersible Sewage Pumps DLFMU–Explosion Proof Non-clog
Specifications
Project: Model: Chk’d: Date:
the pumpage. The oil filled seal chamber shall be designed to prevent over-filling and include an anti-vortexing
vane to insure proper lubrication of both seal faces. Lower face materials shall be silicon carbide (tungsten carbide
for 150-300 DLFU 50 & 60 HP only), upper faces carbon vs. ceramic, NBR elastomers, and 304SS hardware.
Seal system shall not rely on pumping medium for lubrication.

E. Motor Construction:
The pump motor shall be FM Explosion Proof, Class 1, Division 1, Groups C, D. The design shall be an air filled
induction type with a squirrel cage rotor, shell type design, built to NEMA MG-1, Design B specifications. Stator
windings shall be copper, insulated with moisture resistant Class H insulation, rated for 356°F. The stator shall be
dipped and baked three times in Class H varnish and heat shrunk fitted into the stator housing. Rotor bars and short
circuit rings shall be manufactured of cast aluminum. Motor shaft shall be one piece AISI403 material for 2 to 5 HP,
AISI420 for 71/2 to 60 HP material, rotating on two permanently lubricated ball bearings designed for a minimum B-10
life of 60,000 hours. Motor service factor shall be 1.15 and capable of up to 20 starts per hour. The motor shall be
designed for continuous duty pumping at a maximum sump temperature of 104°F. Voltage and frequency tolerances
shall be a maximum 10 / 5% respectively. Motor over temperature protection shall be provided by miniature thermal
protectors embedded in the windings. Mechanical seal failure protection shall be provided by a mechanical float
switch located in a chamber above the seal. This switch shall be comprised of a magnetic float that actuates a dry
reed switch encapsulated within the stem. Should the mechanical seal fail, liquid shall be directed into the float
chamber, in which the rising liquid activates the switch opening the normally closed circuit. For units 2 to 10 HP the
float body and float shall be a polypropylene material with a 316SS stopper. Units 15 HP and greater, the float switch
components shall be 304SS. The motor shall be non-overloading over the entire specified range of operation and be
able to operate at full load intermittently while unsubmerged without damage to the unit.

Power cable jacket shall be manufactured of an oil resistant chloroprene rubber material, designed for submerged
applications. Cable shall be watertight to a depth of a least 65'. The cable entry system shall comprise of primary,
secondary, and tertiary sealing methods. The primary seal shall be achieved by a cylindrical elastomeric grommet
compressed between the motor cover and a 304SS washer. Secondary sealing is accomplished with a compressed
o-ring made of NBR material. Compression and subsequent sealing shall preclude specific torque requirements. The
system shall also include tertiary sealing to prevent leakage into the motor housing due to capillary action through
the insulation if the cable is damaged or cut. The cable wires shall be cut, stripped, re-connected with a copper butt
end connector, and embedded in epoxy within the cable gland. This provides a dead end for leakage through the cable
insulation into the motor junction area. The cable entry system shall be the same for both the power and control cables.

F. Guide Rail system:


Design shall include two (2) 304SS schedule 40 guide rails sized to mount directly to the quick discharge connector,
QDC, at the floor of the wetwell and to a guide rail bracket at the top of the wetwell below the hatch opening, (refer
to project drawings). Intermediate guide brackets are recommended for rail lengths over 15 feet.

Guide rails are not part of the pump package and shall be supplied by others.

The QDC shall be manufactured of cast iron, ASTM A48 Class 30. It shall be designed to adequately support the
guide rails, discharge piping, and pumping unit under both static and dynamic loading conditions with support legs
that are suitable for anchoring it to the wetwell floor. The face of the inlet QDC flange shall be perpendicular to the
floor of the wetwell. The discharge flange of the QDC shall conform to ANSI B16.1 Class 125.

The pump design shall include an integral self-aligning sliding bracket. Sealing of the pumping unit to the QDC shall
be accomplished by a single, linear, downward motion of the pump. The entire weight of the pump unit shall be guided
to and wedged tightly against the inlet flange of the QDC, making metal to metal contact with the pump discharge
forming a seal without the use of bolts, gaskets or o-rings.

A stainless steel lifting chain of adequate length for removing and installing the pump unit is recommended. The chain
shall have a round link with a 2-1/4'' inside diameter every two feet. This link will allow for a sliding pinch bar through
the link to pick the chain, more than once if necessary, at multiple intervals during pump removal and installation.

EBARA Fluid Handling


www.pumpsebara.com 2-164
(t) 803 327 5005 • (f) 803 327 5097 rev. 04/11
EBARA Submersible Sewage Pumps DLFU
Selection Chart
Project: DLFU
Model Model: Chk’d: Date:
Three Phase 60Hz
m ft 60Hz (Synchronous Speed – 1800 RPM)
300
80

60 200 28 29
50 27
150
40 25 / 26 40
23 / 24 39
30 100 7 21 / 22 38 48
6 37 47
80 19 / 20 36
61
TOTAL HEAD

5 46
20 17 / 18 35
60 44 45 60
4
15 50 15 / 16 43 53
34 52 59
40 3 66
13 / 14
10 1 42 51 58
30 33 65
2 57
8 9 / 10 11 / 12 32 50 64
31
6 20 41 63
30 54 62
5 15 49
4 55 56
8
3 10
10 15 20 30 40 50 60 80 100 150 200 300 400 500 600 800 1000 1500 2000 3000 4000 USGPM

0.1 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.5 2.0 3.0 4.0 5.0 6.0 8.0 10 15 m3/min
CAPACITY
Please note: Overlap in coverage is designated by the two numbers; for example "9 / 10". Refer to the legend
below for the specific model numbers.

1 50DLFU61.5 2HP 19 80DLFU611 15HP 37 100DLFU622 30HP 55 250DLBFU615 20HP


2 80DLMFU61.5 2HP 20 100DLMFU611 15HP 38 150DLFU630 40HP 56 250DLCFU615 20HP
3 80DLMFU62.2 3HP 21 80DLFU615 20HP 39 150DLFU637 50HP 57 250DLFU618 25HP
4 80DLMFU63.7 5HP 22 100DLMFU615 20HP 40 150DLFU645 60HP 58 250DLFU622 30HP
5 80DLMFU65.5 7½HP 23 80DLFU618 25HP 41 150DLFU67.5 10HP 59 250DLFU630 40HP
6 80DLCMFU67.5 10HP 24 100DLMFU618 25HP 42 150DLFU611 15HP 60 250DLFU637 50HP
7 80DLCMFU611 15HP 25 80DLFU622 30HP 43 150DLFU615 20HP 61 250DLFU645 60HP
8 100DLFU61.5 2HP 26 100DLMFU622 30HP 44 150DLFU618 25HP 62 300DLFU618 25HP
9 80DLFU61.5 2HP 27 100DLFU630 40HP 45 150DLFU622 30HP 63 300DLFU622 30HP
10 100DLMFU61.5 2HP 28 100DLFU637 50HP 46 200DLFU630 40HP 64 300DLFU630 40HP
11 80DLFU62.2 3HP 29 100DLFU645 60HP 47 200DLFU637 50HP 65 300DLFU637 50HP
12 100DLMFU62.2 3HP 30 100DLFU62.2 3HP 48 200DLFU645 60HP 66 300DLFU645 60HP
13 80DLFU63.7 5HP 31 100DLFU63.7 5HP 49 200DLFU67.5 10HP
14 100DLMFU63.7 5HP 32 100DLFU65.5 7½HP 50 200DLFU611 15HP
15 80DLFU65.5 7½HP 33 100DLFU67.5 10HP 51 200DLFU615 20HP
16 100DLMFU65.5 7½HP 34 100DLFU611 15HP 52 200DLFU618 25HP
17 80DLFU67.5 10HP 35 100DLFU615 20HP 53 200DLFU622 30HP
18 100DLMFU67.5 10HP 36 100DLFU618 25HP 54 250DLFU611 15HP

EBARA Fluid Handling


www.pumpsebara.com 2-165
(t) 803 327 5005 • (f) 803 327 5097 rev. 03/03
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

50DLF61.5 (2HP) Synchronous Speed: 1800 RPM 2, 3 inch Discharge


60
Curve No: DL-C603-9203
Solid Dia 1 1/2"
LM65
Max. Dia. 182mm-No Trim
50

40
Total Head (Ft)
Efficiency (%)

60

50 30
EFFICIENCY

40

Brake Horsepower (BHP)


20
30

20 BHP
10 2

10
1

0 0 0
0 20 40 60 80 100 120 140

Capacity USGPM

80DLF61.5 (2HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


100 50 6.0
Curve No: DL-C604-9203
Solid Dia: 2 1/2"
LM80 5.5
90

5.0
80 40
4.5
70
Max. Dia. 170mm - No Trim 4.0
Total Head (Ft)
Efficiency (%)

60 30
3.5

50 3.0
EFFICIENCY
2.5
40 20
Brake Horsepower (BHP)

BHP 2.0
30
1.5
20 10
1.0

10
0.5

0 0 0.0
0 20 40 60 80 100 120 140 160 180 200 220 240 260

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-166
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

80DLMF61.5 (2HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


50
Curve No: DLM-C601-9203
Solid Dia 3"
LM80
Max. Dia. 170mm-No Trim
40
Total Head (Ft)
Efficiency (%)

60 30

50
EFFICIENCY

40 20

Brake Horsepower (BHP)


30

BHP
20 10 2

10 1

0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260
Capacity USGPM

80DLF62.2 (3HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


40

Curve No: DL-C605-9203


Solid Dia 2 1/2"
Max. Dia. 160mm LL100

30
70
Total Head (Ft)
Efficiency (%)

60
Min. Dia. 145mm
EFFICIENCY
50 20

40
Brake Horsepower (BHP)

30
10
20
BHP
3
10 2
1
0 0 0
0 40 80 120 160 200 240 280 320 360 400
Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-167
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

80DLMF62.2 (3HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


60
Curve No: DLM-C602-9203
Solid Dia 3"
Max. Dia. 188mm - No Trim LM80
50

40
Total Head (Ft)
Efficiency (%)

30
EFFICIENCY
50

Brake Horsepower (BHP)


40 20
BHP
30 3

20 10 2

10 1

0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260
Capacity USGPM

80DLF63.7 (5HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


60
Curve No: DLM-C607-9203
Solid Dia 3"
LL100
50 Max. Dia. 189mm

40
EFFICIENCY (%)

Total Head (Ft)

70
Min. Dia. 171mm
60 30 EFFICIENCY

50
Brake Horsepower (BHP)

40 20

30

BHP
20 10 5

10

0 0 0
0 100 200 300 400 500 600
Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-168
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

80DLMF63.7 (5HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


70

Max. Dia. 208mm Curve No: DLM-C603-9203


Solid Dia 3"
60 LM80

50
Min. Dia. 188mm
Efficiency (%)

Total Head (Ft)

40

70

60 30
EFFICIENCY

Brake Horsepower (BHP)


50

40 20

30
BHP
20 10 5

10

0 0 0
0 40 80 120 160 200 240 280 320

Capacity USGPM

80DLF65.5 (71/2HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


70
Curve No: DLM-C608-9203
Solid Dia 3"
Max. Dia. 207mm LL100
60 60

50 50
EFFICIENCY
EFFICIENCY (%)

Total Head (Ft)

Min. Dia. 186mm


40 40

30 30
Brake Horsepower (BHP)

20 20 8
BHP
6

10 10 4

0 0 0
0 100 200 300 400 500 600
Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-169
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

80DLMF65.5 (71/2HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


90
Curve No: DLM-C604-9203
Max. Dia. 225mm Solid Dia: 3"
80 LM80

70

60 60
Total Head (Ft)

Min. Dia. 203mm


Efficiency (%)

EFFICIENCY

50 50

40 40

Brake Horsepower (BHP)


30 30

20 20 8
BHP
6
10 10 4
2
0 0 0
0 50 100 150 200 250 300 350 400

Capacity USGPM

80DLF67.5 (10HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


80
Curve No: DLM-C609-9203
Max. Dia. 151.9/249mm Solid Dia 3"
70 70 LL100

60 60
EFFICIENCY
EFFICIENCY (%)

Total Head (Ft)

50 50 Min. Dia. 122.9/220mm

40 40

30 30
Brake Horsepower (BHP)

BHP
20 20 10

10 10 5

0 0 0
0 100 200 300 400 500 600 700 800

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-170
(t) 803 327 5005 • (f) 803 327 5097 rev. 02/09
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

80DLCMF67.5 (10HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


100 100 50
Curve No: DLM-C605-9203
Max. Dia. 187.5/259mm T.D.H.
Solid Dia: 3"
90 90 45
LL80

80 80 40
Min. Dia. 165.5/237mm T.D.H.

70 70 35
EFFICIENCY
Total Head (Ft)
Efficiency (%)

60 60 30

50 50 25

Brake Horsepower (BHP)


40 40 20

30 30 15
BHP
20 20 10

10 10 5

0 0 0
0 100 200 300 400 500 600

Capacity USGPM

80DLF611 (15HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


100 90
Max. Dia. 172.4/263mm
Curve No: DLM-C610-9203
Solid Dia 3"
90 80 LL100

80
70

70 Min. Dia. 151.4/242mm


60
Total Head (Ft)
Efficiency(%)

60
50
50
EFFICIENCY
40
40
Brake Horsepower (BHP)

30
30

20
20 BHP
15

10 10 10
5
0 0 0
0 100 200 300 400 500 600 700 800

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-171
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

80DLCMF611 (15HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


100 120
Curve No: DLM-C606-9203
110 Solid Dia 3"
90
Max. Dia. 215/281mm LL80
100
80
90
70
80 EFFICIENCY
Min. Dia. 191/257mm
Efficiency (%)

Total Head (Ft)

60
70

50 60

50
40

Brake Horsepower (BHP)


40
30
30 BHP
15
20
20 10

10
10 5

0 0 0
0 100 200 300 400 500 600
Capacity USGPM

80DLF615 (20HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


120
Curve No: DLM-C611-9203
Max. Dia. 196.4/287mm
110 Solid Dia 3"
LL100
100

90
Min. Dia. 172.4/263mm
80
Total Head (Ft)
Efficiency (%)

70 70

60 60
EFFICIENCY
50 50
Brake Horsepower (BHP)

40 40

30 30
BHP
20 20 20
15
10 10 10
5
0 0 0
0 100 200 300 400 500 600 700 800
Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-172
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

80DLF618 (25HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


140
Max. Dia. 225/307mm Curve No: DLM-C612-9203
Solid Dia 3"
LL100
120

100
Min. Dia. 199/281mm
Total Head (Ft)
Efficiency (%)

80

70

60 60
EFFICIENCY
50 25

Brake Horsepower (BHP)


BHP
40 40 20

30 15

20 20 10

10 5

0 0 0
0 100 200 300 400 500 600 700 800

Capacity USGPM

80DLF622 (30HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


160
Curve No: DLM-C613-9203
Max. Dia. 238/320mm
Solid Dia 3"
140 LL100

120

Min. Dia. 211/293mm


Total Head (Ft)

100
Efficiency (%)

80
70
EFFICIENCY
Brake Horsepower (BHP)

60 60
50
40 40
30 BHP 30
20 20 20
10 10
0 0 0
0 100 200 300 400 500 600 700 800

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-173
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

100DLF61.5 (2HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


30
Curve No: DL-C613-9203
Solid Dia 3"
Max. Dia. 138mm
LM80

60

EFFICIENCY
50 20
Total Head (Ft)
Efficiency (%)

Min. Dia. 125mm


40

30

Brake Horsepower (BHP)


10

20

3
BHP
10 2

0 0 0
0 50 100 150 200 250 300 350

Capacity USGPM

100DLF62.2 (3HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


40
Curve No: DL-C614-9203
Solid Dia 3"
LM80
Max. Dia. 160mm

30

EFFICIENCY
Total Head (Ft)

60
Efficiency (%)

Min. Dia. 145mm


50 20

40
Brake Horsepower (BHP)

30
10
20 BHP
3
10 2
1
0 0 0
0 100 200 300 400

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-174
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

100DLMF62.2 (3HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


40

Curve No: DL-C605-9203


Solid Dia 2 1/2"
Max. Dia. 160mm LL100

30
70
Efficiency (%)

Total Head (Ft)

60
Min. Dia. 145mm
EFFICIENCY
50 20

40

Brake Horsepower (BHP)


30
10
20
BHP
3
10 2
1
0 0 0
0 40 80 120 160 200 240 280 320 360 400
Capacity USGPM

100DLF63.7 (5HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


50
Curve No: DL-C615-9203
Solid Dia 3"
LM80

40
Max. Dia. 172mm
Total Head (Ft)

60 30
Efficiency (%)

EFFICIENCY
Min. Dia. 156mm
50

40 20
Brake Horsepower (BHP)

30

20 10 5
4
BHP 3
10
2
1
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 600

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-175
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

100DLMF63.7 (5HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


60
Curve No: DLM-C607-9203
Solid Dia 3"
LL100
50 Max. Dia. 189mm

40
Total Head (Ft)
Efficiency (%)

70
Min. Dia. 171mm
EFFICIENCY
60 30

50

Brake Horsepower (BHP)


40 20

30

20 10 5
BHP
10

0 0 0
0 100 200 300 400 500 600
Capacity USGPM

100DLF65.5 (71/2HP) Synchronous Speed: 1800 RPM 4, 6 inch Discharge


100 45
Curve No: DLM-C614-9203
Solid Dia 3"
90 40 LL125
Max. Dia. 102.8/217mm
80
35

70
30
Efficiency (%)

Total Head (Ft)

60
Min. Dia. 89.8/204mm EFFICIENCY
25
50
20
40
Brake Horsepower (BHP)

15
30

10 10
20 BHP

10 5 5

0 0 0
0 100 200 300 400 500 600 700 800 900 1000

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-176
(t) 803 327 5005 • (f) 803 327 5097 rev. 03/07
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

100DLMF65.5 (71/2HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


70
Curve No: DLM-C608-9203
Solid Dia 3"
Max. Dia. 207mm LL100
60 60

EFFICIENCY
50 50
Efficiency (%)

Total Head (Ft)

Min. Dia. 186mm


40 40

30 30

Brake Horsepower (BHP)


20 20 8
BHP
6

10 10 4

0 0 0
0 100 200 300 400 500 600
Capacity USGPM

100DLF67.5 (10HP) Synchronous Speed: 1800 RPM 4, 6 inch Discharge


60
Curve No: DLM-C615-9203
Solid Dia 3"
LL125
Max. Dia. 120.8/235mm
100 50

90

80 40
Total Head (Ft)
Efficiency (%)

Min. Dia. 103.8/218mm


70
EFFICIENCY
60 30

50
Brake Horsepower (BHP)

40 20

30
BHP
20 10 10

10 5

0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-176.1
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

100DLMF67.5 (10HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


100 90
Curve No: DLM-C609-9203
80 Solid Dia. 3"
90 LL100 80
Max. Dia. 151.9/249mm.

80 70
70

70 Min. Dia. 122.9/220mm


60 EFFICIENCY 60
Total Head (Ft)

60
50
50
50

Brake Horsepower (BHP)


Efficiency (%)

40 40
40
30 30
30

20 20
20
BHP
10 10 10

0 0 0
0 100 200 300 400 500 600 700 800

Capacity USGPM

100DLF611 (15HP) Synchronous Speed: 1800 RPM 4, 6 inch Discharge


90
Curve No: DLM-C616-9203
Solid Dia 3"
80 LL125
Max. Dia. 142.8/257mm

70 70
EFFICIENCY

60 60
Total Head (Ft)
Efficiency (%)

Min. Dia. 120.7/235mm


50 50

40 40
Brake Horsepower (BHP)

30 30

20 20
BHP
15
10 10 10
5
0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-177
(t) 803 327 5005 • (f) 803 327 5097 rev. 02/15
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

100DLMF611 (15HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


100 90 90
Curve No: DLM-C610-9203
Max. Dia. 172.4/263mm Solid Dia 3"
90 80 80
LL100

80 Min. Dia. 151.4/242mm


70 70

70
60 60
Total Head (Ft)
Efficiency (%)

60
EFFICIENCY
50 50
50
40 40

Brake Horsepower (BHP)


40

30 30
30

20 20
20 BHP

10 10 10

0 0 0
0 100 200 300 400 500 600 700 800

Capacity USGPM

100DLF615 (20HP) Synchronous Speed: 1800 RPM 4, 6 inch Discharge


110
Curve No: DLM-C617-9203
Max. Dia. 173.1/278mm
Solid Dia 3"
100
LL125

90

80

70 70 EFFICIENCY
Total Head (Ft)

Min. Dia. 151.1/256mm


Efficiency (%)

60 60

50 50
Brake Horsepower (BHP)

40 40

30 30

BHP
20 20 20
15
10 10 10
5
0 0 0
0 200 400 600 800 1000 1200

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-178
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

100DLMF615 (20HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


120
Curve No: DLM-C611-9203
Max. Dia. 196.4/287mm
110 Solid Dia 3"
LL100
100

90
Min. Dia. 172.4/263mm
80
Total Head (Ft)
Efficiency (%)

70 70

60 60
EFFICIENCY
50 50

Brake Horsepower (BHP)


40 40

30 30
BHP
20 20 20
15
10 10 10
5
0 0 0
0 100 200 300 400 500 600 700 800
Capacity USGPM

100DLMF618 (25HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


140
Max. Dia. 225/307mm Curve No: DLM-C612-9203
Solid Dia 3"
LL100
120

100
Min. Dia. 199/281mm
Total Head (Ft)
Efficiency (%)

80

70

60 60
EFFICIENCY
50 25
Brake Horsepower (BHP)

40 40 20

30 BHP 15

20 20 10

10 5

0 0 0
0 100 200 300 400 500 600 700 800

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-179
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

100DLF618 (25HP) Synchronous Speed: 1800 RPM 4, 6 inch Discharge


120
Curve No: DLM-C618-9203
110 Solid Dia 3"
Max. Dia. 192/288mm LL125

100 100

90 90

80 80
Min. Dia. 168/264mm
Total Head (Ft)
Efficiency (%)

70 70

60 60

50 50

Brake Horsepower (BHP)


EFFICIENCY
40 40

30 30
25
20 20 20
BHP
15
10 10 10
5
0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200

Capacity USGPM

100DLMF622 (30HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


160
Curve No: DLM-C613-9203
Max. Dia. 238/320mm
Solid Dia 3"
140 LL100

120

Min. Dia. 211/293mm


Total Head (Ft)

100
Efficiency (%)

80
70
EFFICIENCY
Brake Horsepower (BHP)

60 60
50
40 40
30 BHP 30
20 20 20
10 10
0 0 0
0 100 200 300 400 500 600 700 800

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-180
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

100DLF622 (30HP) Synchronous Speed: 1800 RPM 4, 6 inch Discharge


140
Curve No: DLM-C619-9203
Max. Dia. 208/304mm Solid Dia 3"
120 LL125

100 100

90
Total Head (Ft)

Min. Dia. 183/279mm


Efficiency (%)

80 80

70

60 60

Brake Horsepower (BHP)


50
EFFICIENCY
40 40

30 30

20 20 BHP 20

10 10

0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200
Capacity USGPM

100DLF630 to 645 (40-60HP) Synchronous Speed: 1800 RPM 3, 4 inch Discharge


260
D = 360mm
Curve No: DL-C601-9608
240 50 Solid Dia 3"
D = 345mm
60 LL100

220 65
D = 330mm
68
200
D = 315mm
70
Total Head (Ft)

180 D = 300mm

160
70
140

120
40 HP

100
60 HP

80
50 HP
60

40
0 200 400 600 800 1000 1200 1400 1600 1800
Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-180.1
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
150DLF67.5 200DLF67.5 (10HP) Synchronous Speed: 1800 RPM 6, 8 inch Discharge
60
Curve No: DL-C622-9203
Solid Dia 3"
LL150

50
Max. Dia. 124.6/225mm

70
40 EFFICIENCY
Total Head (Ft)
Efficiency (%)

60

Min. Dia. 107.6/208mm


50 30

40

Brake Horsepower (BHP)


20
30

20 BHP
10 10

10
5

0 0 0
0 200 400 600 800 1000 1200 1400

Capacity USGPM

150DLF611 200DLF611 (15HP) Synchronous Speed: 1800 RPM 6, 8 inch Discharge


80
Curve No: DL-C623-9203
Solid Dia 3"
LL150
70 70
Max. Dia. 143.6/244mm
EFFICIENCY
60 60
Total Head (Ft)

50 50
Efficiency (%)

40 40

Min. Dia. 125.6/226mm


30 30
Brake Horsepower (BHP)

20 20
BHP
15
10 10 10
5
0 0 0
0 200 400 600 800 1000 1200 1400 1600

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-181
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

150DLF615 200DLF615 (20HP) Synchronous Speed: 1800 RPM 6, 8 inch Discharge


100
Curve No: DL-C624-9203
Max. Dia. 180/268mm Solid Dia 3"
90 LL150

80

70 70
Total Head (Ft)

EFFICIENCY
Efficiency (%)

60 60
Min. Dia. 152/240mm

50 50

40 40

Brake Horsepower (BHP)


30 30

BHP
20 20 20

10 10 10

0 0 0
0 200 400 600 800 1000 1200 1400 1600

Capacity USGPM

150DLF618 200DLF618 (25HP) Synchronous Speed: 1800 RPM 6, 8 inch Discharge


110
Curve No: DL-C625-9203
Solid Dia 3"
100 LL150
Max. Dia. 186/274mm

90

80

EFFICIENCY
Total Head (Ft)

70 70
Min. Dia. 163/251mm
Efficiency (%)

60 60

50 50
Brake Horsepower (BHP)

40 40

30 30 BHP
25
20 20 20
15
10 10 10
5
0 0 0
0 200 400 600 800 1000 1200 1400 1600

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-181.1
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:
150DLF622 200DLF622 (30HP) Synchronous Speed: 1800 RPM 6,8 inch Discharge
110
Curve No: DL-C626-9203
Solid Dia 3"
100 LL150
Max. Dia. 192/296mm
90

80

EFFICIENCY
70 70
Total Head (Ft)

Min. Dia. 168/272mm


Efficiency (%)

60 60

50 50

40 40

Brake Horsepower (BHP)


BHP
30 30 30

20 20 20

10 10 10

0 0 0
0 200 400 600 800 1000 1200 1400 1600

Capacity USGPM

150DLF630 (40HP) Synchronous Speed: 1800 RPM 6 inch Discharge


140
Curve No: DLY-C601-9203
Solid Dia 3"
Max. Dia. 204/310mm LL150Y
120

100
Total Head (Ft)

Min. Dia. 178/284mm


Efficiency (%)

80 80

70
EFFICIENCY
60 60

50
Brake Horsepower (BHP)

40 40 BHP 40

30 30

20 20 20

10 10

0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-182
(t) 803 327 5005 • (f) 803 327 5097 rev. 02/15
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

150DLF637 (50HP) Synchronous Speed: 1800 RPM 6 inch Discharge


160
Curve No: DLY-C602-9203
Max. Dia. 226/324mm Solid Dia 3"
140 LL150Y

120

Min. Dia. 199/297mm


100
Total Head (Ft)
Efficiency (%)

80
70 EFFICIENCY
60 60

Brake Horsepower (BHP)


50 BHP 50
40 40 40
30 30
20 20 20
10 10
0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000

Capacity USGPM

150DLF645 (60HP) Synchronous Speed: 1800 RPM 6 inch Discharge


200
Curve No: DLY-C603-9203
Solid Dia 3"
180 Max. Dia. 255/353mm LL150Y

80 160

EFFICIENCY
70 140
Total Head (Ft)
Efficiency (%)

60 120 Min. Dia. 225/323mm

50 100

40 80
Brake Horsepower (BHP)

30 60

20 40 60
BHP
50
10 20 40
30
0 0 20
0 200 400 600 800 1000 1200 1400 1600 1800

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-183
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

200DLF630 (40HP) Synchronous Speed: 1800 RPM 8 inch Discharge


120
Curve No: DLY-C604-9203
110 Solid Dia 3"
Max. Dia. 220/307mm
LL200Y
100

90

80
Min. Dia. 194/281mm
Total Head (Ft)
Efficiency (%)

70 70

60 60
EFFICIENCY
50 50

Brake Horsepower (BHP)


40 40

30 30
BHP
20 20 40
30
10 10 20
10
0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200

Capacity USGPM

200DLF637 (50HP) Synchronous Speed: 1800 RPM 8 inch Discharge


160
Curve No: DLY-C605-9203
Solid Dia 3"
140 LL200Y
Max. Dia. 241/328mm

120

100
Total Head (Ft)

Min. Dia. 217/304mm


Efficiency (%)

80
70
EFFICIENCY
60 60
Brake Horsepower (BHP)

50
BHP
40 40 50
30 40
20 20 30
10 20
0 0 10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-184
(t) 803 327 5005 • (f) 803 327 5097 rev. 02/15
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

200DLF645 (60HP) Synchronous Speed: 1800 RPM 8 inch Discharge


180
Curve No: DLY-C606-9203
Solid Dia 3"
160 LL200Y
Max. Dia. 263/350mm

80 140

EFFICIENCY
Total Head (Ft)

70 120
Efficiency (%)

Min. Dia. 232/319mm


60 100

50 80

Brake Horsepower (BHP)


40 60 BHP 60
50
30 40 40
30
20 20 20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400

Capacity USGPM

250DLF611 (15HP) Synchronous Speed: 1800 RPM 10 inch Discharge


100 60
Curve No: DL-C627-9203
Solid Dia 3 1/4"
90
LL250
Max. Dia. 143.1/243mm
50
80

70 EFFICIENCY
40
EFFICIENCY (%)

Total Head (Ft)

60

Min. Dia. 130.1/230mm


50 30

40
Brake Horsepower (BHP)

20
30
BHP
15
20
10 10

10
5

0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-185
(t) 803 327 5005 • (f) 803 327 5097 rev. 03/07
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

250DLBF615 (20HP) Synchronous Speed: 1800 RPM 10 inch Discharge


70
Curve No: DL-C628-9203
Solid Dia 3 1/4"
LL250
60

Max. Dia. 158.1/258mm


50
EFFICIENCY (%)

Total Head (Ft)

40

70
EFFICIENCY
Min. Dia. 138.1/238mm
60 30

Brake Horsepower (BHP)


50

40 20

30
BHP
20 10 20

10 10

0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200

Capacity USGPM

250DLCF615 (20HP) Synchronous Speed: 1800 RPM 10 inch Discharge


80
Curve No: DL-C629-9203
Solid Dia 3 1/4"
70 LL250

Max. Dia. 171/265mm


60
EFFICIENCY (%)

Total Head (Ft)

50

Min. Dia. 151/245mm


40
70 EFFICIENCY
60 30
Brake Horsepower (BHP)

50
40 20
30 25
BHP
20 10 20
10 15
0 0 10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-186
(t) 803 327 5005 • (f) 803 327 5097 rev. 02/15
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

250DLF618 (25HP) Synchronous Speed: 1800 RPM 10 inch Discharge


90
Curve No: DL-C630-9203
Solid Dia 3 1/4"
80 LL250
Max. Dia. 179/273mm

70 70
EFFICIENCY

60 60
EFFICIENCY (%)

Total Head (Ft)

50 50
Min. Dia. 157/251mm

40 40

Brake Horsepower (BHP)


30 30
BHP
25
20 20 20
15
10 10 10
5
0 0 0
0 400 800 1200 1600 2000 2400

Capacity USGPM

250DLF622 (30HP) Synchronous Speed: 1800 RPM 10 inch Discharge


100

Max. Dia. 187/281mm Curve No: DL-C631-9203


90 Solid Dia 3 1/4"
LL250

80 80
EFFICIENCY
70 70
EFFICIENCY (%)

Total Head (Ft)

60 60
Min. Dia. 169/263mm

50 50

40 40
Brake Horsepower (BHP)

BHP
30 30 30

20 20 20

10 10 10

0 0 0
0 400 800 1200 1600 2000 2400

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-187
(t) 803 327 5005 • (f) 803 327 5097 rev. 02/15
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

250DLF630 (40HP) Synchronous Speed: 1800 RPM 10 inch Discharge


100
Max. Dia. 216/306mm
Curve No: DLY-C607-9203
90 Solid Dia 3"
LL250Y

80 80

EFFICIENCY
70 70
EFFICIENCY (%)

Min. Dia. 190/280mm


Total Head (Ft)

60 60

50 50

40 40

Brake Horsepower (BHP)


30 30

BHP
20 20 40
30
10 10 20
10
0 0 0
0 300 600 900 1200 1500 1800 2100 2400 2700 3000

Capacity USGPM

250DLF637 (50HP) Synchronous Speed: 1800 RPM 10 inch Discharge


140
Max. Dia. 231/321mm
Curve No: DLY-C608-9203
Solid Dia 3"
120 LL250Y

100
EFFICIENCY (%)

Total Head (Ft)

Min. Dia. 203/293mm


80
EFFICIENCY
70

60 60
BHP
50 50
Brake Horsepower (BHP)

40 40 40

30 30

20 20 20

10 10

0 0 0
0 500 1000 1500 2000 2500 3000

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-188
(t) 803 327 5005 • (f) 803 327 5097 rev. 02/15
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

250DLF645 (60HP) Synchronous Speed: 1800 RPM 10 inch Discharge


140

Curve No: DLY-C609-9203


Max. Dia. 248/338mm
Solid Dia 3"
120 LL250Y

100
EFFICIENCY (%)

Total Head (Ft)

Min. Dia. 219/309mm


80 80
EFFICIENCY
70

60 60

Brake Horsepower (BHP)


50

40 40
BHP
30 60

20 20 40

10 20

0 0 0
0 500 1000 1500 2000 2500 3000 3500

Capacity USGPM

300DLF618 (25HP) Synchronous Speed: 1800 RPM 12 inch Discharge


50
Curve No: DL-C632-9203
Solid Dia 3 1/2"
LL300
Max. Dia. 137.1/237mm
40
EFFICIENCY (%)

Total Head (Ft)

60 30
EFFICIENCY
50
Min. Dia. 120.1/220mm
40 20
Brake Horsepower (BHP)

30
BHP
25
20 10 20
15
10 10
5
0 0 0
0 1000 2000 3000
Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-189
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

300DLF622 (30HP) Synchronous Speed: 1800 RPM 12 inch Discharge


50
Max. Dia. 151.1/251mm Curve No: DL-C633-9203
Solid Dia 3 1/2"
LL300

40
Total Head (Ft)
Efficiency (%)

60 30 EFFICIENCY
Min. Dia. 131.1/231mm

50

40 20

Brake Horsepower (BHP)


30

20 10 BHP 30

10 20

0 0 10
0 1000 2000 3000
Capacity USGPM

300DLF630 (40HP) Synchronous Speed: 1800 RPM 12 inch Discharge


60
Max. Dia. 155.6/274mm Curve No: DLY-C610-9203
Solid Dia 3"
LL300Y
50

40
Total Head (Ft)
Efficiency (%)

Min. Dia. 134.6/253mm


70
EFFICIENCY
60 30

50
Brake Horsepower (BHP)

40 20
BHP
30 40

20 10 30

10 20

0 0 10
0 1000 2000 3000 4000
Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-190
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Performance Curves
Project: GPM: TDH: EFF: HP: Chk’d: Date:

300DLF637 (50HP) Synchronous Speed: 1800 RPM 12 inch Discharge


80

Curve No: DLY-C611-9203


Max. Dia. 174/278mm
Solid Dia 3"
70
LL300Y

60
EFFICIENCY (%)

50
Total Head (Ft)

Min. Dia. 151/255mm

80 40
70
60 30

Brake Horsepower (BHP)


EFFICIENCY
50
40 20 BHP 50
30 40
20 10 30
10 20
0 0 10
0 600 1200 1800 2400 3000 3600 4200

Capacity USGPM

300DLF645 (60HP) Synchronous Speed: 1800 RPM 12 inch Discharge


100
Curve No: DLY-C612-9203
Solid Dia 3"
90 Max. Dia. 191/295mm LL300Y

80 80

EFFICIENCY
70 70
EFFICIENCY (%)

Total Head (Ft)

60 60
Min. Dia. 167/271mm

50 50

40 40
Brake Horsepower (BHP)

30 30

BHP
20 20 60
50
10 10 40
30
0 0 20
0 1000 2000 3000 4000 5000

Capacity USGPM

EBARA Fluid Handling


www.pumpsebara.com 2-190.1
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU
50DLFU, 2HP
80DLFU, 2 to 30HP

f
e
ø

t
(n) QTY - (h) HOLES

Flange (ANSI 125 PSI F.F)


inch
ø e f t n h
2 43/4 6 5
/8 4 3
/4
3 6 71/2 3
/4 4 3
/4
4 71/2 9 15
/16 8 3
/4

mm
ø e f t n h
50 121 152 16 4 19
80 152 191 19 4 19
100 191 229 24 8 19
Dimensions: inch
OUTPUT PUMP & MOTOR
PHASE SIZE
ø MODEL WEIGHT
Lb
kW HP A B C D E F G H J L
2/3 50DLFU61.5 1.5 2 1711/16 101/8 125/8 51/16 95/8 77/8 5
/16 2711/16 71/16 65/16 132
80DLFU61.5 1.5 2 203/4 111/2 15 53/4 111/4 811/16 5
/16 281/2 81/4 71/16 148
80DLFU62.2 2.2 3 2313/16 133/16 173/16 65/8 13 /8
3
913/16 5
/16 301/4 91/4 81/16 209
80DLFU63.7 3.7 5 2313/16 133/16 173/16 65/8 133/8 913/16 5
/16 3113/16 91/4 81/16 209
80DLFU65.5 5.5 71/2 2313/16 133/16 173/16 65/8 13 /8
3
913/16 3
/8 371/8 91/4 11 317
THREE 3/4 80DLFU67.5 7.5 10 251/16 141/2 173/4 75/16 14 1211/16 3
/8 361/16 913/16 101/4 344
80DLFU611 11 15 261/8 153/16 189/16 75/8 143/4 1211/16 5
/16 399/16 105/8 913/16 470
80DLFU615 15 20 261/8 153/16 189/16 75/8 143/4 1211/16 5
/16 425/16 105/8 1013/16 564
80DLFU618 18.5 25 271/4 1513/16 195/16 715/16 15 /16 1211/16
9 5
/16 437/8 117/16 1013/16 639
80DLFU622 22 30 271/4 1513/16 195/16 715/16 159/16 1211/16 5
/16 437/8 117/16 1013/16 694

Dimensions: mm
OUTPUT PUMP & MOTOR
PHASE SIZE
ø
MODEL WEIGHT
kg
kW HP A B C D E F G H J L
50/80 50DLFU61.5 1.5 2 450 257 321 129 245 200 8 703 180 160 60
80DLFU61.5 1.5 2 527 292 381 146 285 220 8 724 210 180 67
80DLFU62.2 2.2 3 605 335 436 169 340 250 8 768 235 205 95
80DLFU63.7 3.7 5 605 335 436 169 340 250 8 808 235 205 95
80DLFU65.5 5.5 71/2 605 335 436 169 340 250 10 943 235 280 144
THREE 80/100 80DLFU67.5 7.5 10 636 369 451 186 355 323 10 916 250 260 156
80DLFU611 11 15 664 385 471 193 375 323 8 1005 270 250 213
80DLFU615 15 20 664 385 471 193 375 323 8 1075 270 275 256
80DLFU618 18.5 25 692 402 491 202 395 323 8 1115 290 275 290
80DLFU622 22 30 692 402 491 202 395 323 8 1115 290 275 315
*Note: All 80DLFU dimensions are based on 3'' discharge.
EBARA Fluid Handling
www.pumpsebara.com 2-191
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLMFU
80DLMFU, 2 to 71/2HP
80DLCMFU, 10 to 15HP

f
e
ø

t
(n) QTY - (h) HOLES

Flange (ANSI 125 PSI F.F)


inch
ø e f t n h
3 6 71/2 3
/4 4 3
/4
4 71/2 9 15
/16 8 3
/4
mm
ø e f t n h
80 152 191 19 4 19
100 191 229 24 8 19

Dimensions: inch
OUTPUT PUMP & MOTOR
PHASE SIZE
ø MODEL WEIGHT
Lb
kW HP A B C D E F G H J L
80DLMFU61.5 1.5 2 203/4 111/2 15 53/4 111/4 811/16 5
/16 281/2 81/4 7 /16
1
157
80DLMFU62.2 2.2 3 203/4 111/2 15 53/4 111/4 811/16 5
/16 291/2 81/4 71/2 187
80DLMFU63.7 3.7 5 217/16 121/8 153/8 61/16 115/8 811/16 5
/16 311/16 811/16 71/2 205
THREE 3/4
80DLMFU65.5 5.5 71/2 227/16 1215/16 16 67/16 12 /16
3
811/16 3
/8 363/8 91/4 101/4 311
80DLCMFU67.5 7.5 10 263/8 1415/16 187/8 71/2 133/16 121/16 3
/8 355/8 101/4 97/16 375
80DLCMFU611 11 15 279/16 1511/16 1911/16 77/8 14 12 5
/16 395/16 11 97/16 500

Dimensions: mm
OUTPUT PUMP & MOTOR
PHASE SIZE
ø MODEL WEIGHT
kg
kW HP A B C D E F G H J L
80DLMFU61.5 1.5 2 527 292 381 146 285 220 8 724 210 180 71
80DLMFU62.2 2.2 3 527 292 381 146 285 220 8 750 210 190 85
80DLMFU63.7 3.7 5 545 308 391 154 295 220 8 789 220 190 93
THREE 80/100
80DLMFU65.5 5.5 71/2 570 328 406 164 310 220 10 924 235 261 141
80DLCMFU67.5 7.5 10 670 379 480 190 335 307 10 905 260 240 170
80DLCMFU611 11 15 700 399 500 200 355 305 8 998 280 240 227
*Note: All dimensions are based on 3'' discharge.
EBARA Fluid Handling
www.pumpsebara.com 2-192
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU
100DLFU, 2 to 60HP

f
e
ø

t
(n) QTY - (h) HOLES

Flange (ANSI 125 PSI F.F)


inch
ø e f t n h
3 6 71/2 3
/4 4 3
/4
4 71/2 9 15
/16 8 3
/4
6 91/2 11 1 8 7
/8
mm
ø e f t n h
80 152 191 19 4 19
100 191 229 24 8 19
150 241 279 25 8 22
Dimensions: inch
OUTPUT PUMP & MOTOR
PHASE SIZE
ø MODEL WEIGHT
Lb
kW HP A B C D E F G H J L
3/4 100DLFU61.5 1.5 2 213/4 101/2 169/16 51/4 12 1013/16 5
/16 2915/16 77/8 811/16 170
100DLFU62.2 2.2 3 227/8 111/8 175/16 59/16 1213/16 1013/16 5
/16 3013/16 811/16 811/16 198
100DLFU63.7 3.7 5 227/8 111/8 175/16 59/16 1213/16 1013/16 5
/16 323/8 811/16 811/16 216
100DLFU65.5 5.5 71/2 289/16 1511/16 2011/16 77/8 161/8 15 3
/8 377/16 11 117/16 353
100DLFU67.5 7.5 10 289/16 1511/16 2011/16 77/8 161/8 15 3
/8 377/16 11 117/16 395
4/6 100DLFU611 11 15 289/16 1511/16 2011/16 77/8 161/8 15 5
/16 411/8 11 117/16 476
THREE
100DLFU615 15 20 293/4 167/16 217/16 81/4 1615/16 1413/16 5
/16 431/4 1113/16 1113/16 602
100DLFU618 18.5 25 307/8 171/4 221/4 811/16 1711/16 1413/16 5
/16 4413/16 125/8 1113/16 677
100DLFU622 22 30 307/8 171/4 221/4 811/16 1711/16 1413/16 5
/16 4413/16 125/8 1113/16 736
4 100DLFU630 30 40 331/4 199/16 235/8 95/8 191/8 197/16 5
/16 553/4 143/16 195/16 1001
100DLFU637 37 50 331/4 199/16 235/8 95/8 191/8 197/16 5
/16 595/16 143/16 205/16 1171
100DLFU645 45 60 331/4 199/16 235/8 95/8 19 /
1
8 197/16 5
/16 595/16 143/16 205/16 1219

Dimensions: mm
OUTPUT PUMP & MOTOR
PHASE SIZE
ø MODEL WEIGHT
kg
kW HP A B C D E F G H J L
100DLFU61.5 1.5 2 553 267 420 134 305 275 8 760 200 220 77
80/100
100DLFU62.2 2.2 3 581 282 440 141 325 275 8 782 220 220 90
100DLFU63.7 3.7 5 581 282 440 141 325 275 8 822 220 220 98
100DLFU65.5 5.5 71/2 725 398 525 200 410 381 10 951 280 290 160
100DLFU67.5 7.5 10 725 398 525 200 410 381 10 951 280 290 179
100DLFU611 11 15 725 398 525 200 410 381 8 1044 280 290 216
THREE 100/150
100DLFU615 15 20 755 417 545 210 430 377 8 1099 300 300 273
100DLFU618 18.5 25 784 438 565 220 450 377 8 1139 320 300 307
100DLFU622 22 30 784 438 565 220 450 377 8 1139 320 300 334
100 100DLFU630 30 40 845 497 600 245 485 493 8 1416 360 490 454
100DLFU637 37 50 845 497 600 245 485 493 8 1506 360 516 531
100DLFU645 45 60 845 497 600 245 485 493 8 1506 360 516 553
*Note: All dimensions are based on 4'' discharge.
EBARA Fluid Handling
www.pumpsebara.com 2-193
(t) 803 327 5005 • (f) 803 327 5097 rev. 11/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLMFU
100DLMFU, 3 to 30HP

f
e
ø

t
(n) QTY - (h) HOLES

Flange (ANSI 125 PSI F.F)


inch
ø e f t n h
3 6 71/2 3
/4 4 3
/4
4 71/2 9 15
/16 8 3
/4
mm
ø e f t n h
80 152 191 19 4 19
100 191 229 24 8 19
Dimensions: inch
OUTPUT PUMP & MOTOR
PHASE SIZE MODEL WEIGHT
Lb
ø kW HP A B C D E F G H J L
100DLMFU62.2 2.2 3 249/16 133/16 1715/16 65/8 133/8 913/16 5
/16 301/4 91/4 81/16 209
100DLMFU63.7 3.7 5 249/16 133/16 1715/16 65/8 133/8 913/16 5
/16 3113/16 91/4 81/16 209
100DLMFU65.5 5.5 71/2 249/16 133/16 1715/16 65/8 13 /8
3
913/16 3
/8 371/8 91/4 11 317
100DLMFU67.5 7.5 10 2513/16 141/2 181/2 75/16 14 1211/16 3
/8 361/16 913/16 101/4 344
THREE 3/4
100DLMFU611 11 15 267/8 153/16 181/2 75/8 143/4 1211/16 5
/16 399/16 105/8 913/16 470
100DLMFU615 15 20 267/8 153/16 181/2 75/8 143/4 1211/16 5
/16 425/16 105/8 1013/16 564
100DLMFU618 18.5 25 28 1513/16 201/16 715/16 15 /16 1211/16
9 5
/16 437/8 117/16 1013/16 639
100DLMFU622 22 30 28 1513/16 201/16 715/16 159/16 1211/16 5
/16 437/8 117/16 1013/16 694

Dimensions: mm
OUTPUT PUMP & MOTOR
PHASE SIZE MODEL WEIGHT
kg
ø kW HP A B C D E F G H J L
100DLMFU62.2 2.2 3 624 335 455 169 340 250 8 768 235 205 95
100DLMFU63.7 3.7 5 624 335 455 169 340 250 8 808 235 205 95
100DLMFU65.5 5.5 71/2 624 335 455 169 340 250 10 943 235 280 144
100DLMFU67.5 7.5 10 655 369 470 186 355 323 10 916 250 260 156
THREE 80/100
100DLMFU611 11 15 683 385 470 193 375 323 8 1005 270 250 213
100DLMFU615 15 20 683 385 470 193 375 323 8 1075 270 275 256
100DLMFU618 18.5 25 711 402 510 202 395 323 8 1115 290 275 290
100DLMFU622 22 30 711 402 510 202 395 323 8 1115 290 275 315

*Note: All dimensions are based on 4'' discharge.


EBARA Fluid Handling
www.pumpsebara.com 2-193.1
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU
150DLFU, 10 to 60HP

f
e
ø

t
(n) QTY - (h) HOLES

Flange (ANSI 125 PSI F.F)


inch
ø e f t n h
6 91/2 11 1 8 7
/8
8 113/4 131/2 11/8 8 7
/8
mm
ø e f t n h
150 241 279 25 8 22
200 298 343 29 8 22

Dimensions: inch
OUTPUT PUMP & MOTOR
PHASE SIZE MODEL WEIGHT
Lb
ø kW HP A B C D E F G H J L
150DLFU67.5 7.5 10 313/4 1615/16 231/4 89/16 1711/16 165/16 3
/8 381/2 1113/16 123/8 428
150DLFU611 11 15 313/4 1615/16 231/4 89/16 1711/16 165/16 5
/16 423/16 1113/16 123/8 549
150DLFU615 15 20 33 1713/16 24 9 181/2 161/8 5
/16 441/4 125/8 125/8 635
150DLFU618 18.5 25 33 1713/16 24 9 18 /2
1
161/8 5
/16 4513/16 125/8 125/8 712
THREE 6/8
150DLFU622 22 30 341/4 187/8 2413/16 91/2 195/16 163/16 5
/16 453/4 133/8 125/8 787
150DLFU630 30 40 321/2 189/16 231/4 95/16 173/4 237/8 5
/16 529/16 133/4 161/8 1294
150DLFU637 37 50 321/2 189/16 231/4 95/16 173/4 237/8 5
/16 557/8 133/4 1615/16 1345
150DLFU645 45 60 321/2 189/16 231/4 95/16 17 /4
3
237/8 5
/16 557/8 133/4 1615/16 1404

Dimensions: mm
OUTPUT PUMP & MOTOR WEIGHT
PHASE SIZE MODEL kg
ø kW HP A B C D E F G H J L
150DLFU67.5 7.5 10 806 430 590 217 450 414 10 978 300 315 194
150DLFU611 11 15 806 430 590 217 450 414 8 1071 300 315 249
150DLFU615 15 20 838 453 610 228 470 410 8 1124 320 320 288
150DLFU618 18.5 25 838 453 610 228 470 410 8 1164 320 320 323
THREE 150/200
150DLFU622 22 30 870 479 630 241 490 411 8 1162 340 320 357
150DLFU630 30 40 826 471 590 236 451 607 8 1335 350 409 587
150DLFU637 37 50 826 471 590 236 451 607 8 1420 350 430 610
150DLFU645 45 60 826 471 590 236 451 607 8 1420 350 430 637

EBARA Fluid Handling


www.pumpsebara.com 2-194
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU
200DLFU, 10 to 60HP

f
e
ø

t
(n) QTY - (h) HOLES

Flange (ANSI 125 PSI F.F)


inch
ø e f t n h
6 91/2 11 1 8 7
/8
8 113/4 131/2 11/8 8 7
/8
mm
ø e f t n h
150 241 279 25 8 22
200 298 343 29 8 22

Dimensions: inch
OUTPUT PUMP & MOTOR
PHASE SIZE MODEL WEIGHT
Lb
ø kW HP A B C D E F G H J L
200DLFU67.5 7.5 10 33 1615/16 241/2 89/16 1711/16 165/16 3
/8 381/2 1113/16 123/8 428
200DLFU611 11 15 337/16 1615/16 241/2 9 1711/16 165/16 5
/16 423/16 1113/16 123/8 549
200DLFU615 15 20 341/4 1713/16 251/4 9 181/2 161/8 5
/16 441/4 125/8 125/8 635
200DLFU618 18.5 25 343/4 1713/16 251/4 91/2 181/2 161/8 5
/16 4513/16 125/8 125/8 712
THREE 6/8
200DLFU622 22 30 349/16 187/8 261/16 89/16 19 /16
5
163/16 5
/16 453/4 133/8 125/8 787
200DLFU630 30 40 353/16 209/16 247/8 105/16 181/8 263/16 5
/16 541/8 143/16 1711/16 1347
200DLFU637 37 50 353/16 209/16 247/8 105/16 18 /8
1
263/16 5
/16 571/2 143/16 181/2 1398
200DLFU645 45 60 353/16 209/16 247/8 105/16 181/8 263/16 5
/16 571/2 143/16 181/2 1457

Dimensions: mm
OUTPUT PUMP & MOTOR WEIGHT
PHASE SIZE MODEL kg
ø kW HP A B C D E F G H J L
200DLFU67.5 7.5 10 838 430 622 217 450 414 10 978 300 315 194
200DLFU611 11 15 850 430 622 228 450 414 8 1071 300 315 249
200DLFU615 15 20 870 453 642 228 470 410 8 1124 320 320 288
200DLFU618 18.5 25 882 453 642 241 470 410 8 1164 320 320 323
THREE 150/200
200DLFU622 22 30 878 479 662 217 490 411 8 1162 340 320 357
200DLFU630 30 40 895 522 632 262 461 665 8 1375 360 449 611
200DLFU637 37 50 895 522 632 262 461 665 8 1460 360 470 634
200DLFU645 45 60 895 522 632 262 461 665 8 1460 360 470 661

EBARA Fluid Handling


www.pumpsebara.com 2-195
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU
250DLFU, 15 to 60HP

f
e
ø

t
(n) QTY - (h) HOLES

Flange (ANSI 125 PSI F.F)


inch
ø e f t n h
10 141/4 16 13/16 12 1
mm
ø e f t n h
250 362 406 30 12 25

Dimensions: inch
OUTPUT PUMP & MOTOR
PHASE SIZE MODEL WEIGHT
Lb
ø kW HP A B C D E F G H J L
250DLFU611 11 15 381/4 205/8 2711/16 109/16 1911/16 241/2 5
/16 451/4 149/16 153/8 736
250DLBFU615 15 20 381/4 205/8 2711/16 109/16 1911/16 241/2 5
/16 4711/16 149/16 161/8 833
250DLCFU615 15 20 393/16 215/16 287/16 103/4 20 /
1
2 2415/16 5
/16 477/8 153/8 165/16 877
10 250DLFU618 18.5 25 393/16 215/16 287/16 103/4 201/2 2415/16 5
/16 497/16 153/8 165/16 959
THREE
250DLFU622 22 30 393/16 215/16 287/16 103/4 20 /
1
2 2415/16 5
/16 497/16 153/8 165/16 1030
250DLFU630 30 40 423/8 2311/16 301/2 1115/16 221/2 2913/16 5
/16 571/16 175/16 209/16 1570
250DLFU637 37 50 423/8 2311/16 301/2 1115/16 22 /
1
2 2913/16 5
/16 603/8 175/16 217/16 1631
250DLFU645 45 60 423/8 2311/16 301/2 1115/16 221/2 2913/16 5
/16 603/8 175/16 217/16 1713

Dimensions: mm
OUTPUT PUMP & MOTOR
PHASE SIZE MODEL WEIGHT
kg
ø kW HP A B C D E F G H J L
250DLFU611 11 10 972 524 703 269 500 622 8 1149 370 390 334
250DLBFU615 15 20 972 524 703 269 500 622 8 1211 370 410 378
250DLCFU615 15 20 996 541 723 273 520 634 8 1216 390 415 398
250DLFU618 18.5 25 996 541 723 273 520 634 8 1256 390 415 435
THREE 250
250DLFU622 22 30 996 541 723 273 520 634 8 1256 390 415 467
250DLFU630 30 40 1077 602 774 304 571 757 8 1449 440 523 712
250DLFU637 37 50 1077 602 774 304 571 757 8 1534 440 544 740
250DLFU645 45 60 1077 602 774 304 571 757 8 1534 440 544 777

EBARA Fluid Handling


www.pumpsebara.com 2-196
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU
300DLFU, 25 to 60HP

f
e
ø

t
(n) QTY - (h) HOLES

Flange (ANSI 125 PSI F.F)


inch
ø e f t n h
12 17 19 11/4 12 1
mm
ø e f t n h
300 432 483 32 12 25

Dimensions: inch
OUTPUT PUMP & MOTOR
PHASE SIZE MODEL WEIGHT
Lb
ø kW HP A B C D E F G H J L
300DLFU618 18.5 25 44 231/8 323/16 117/8 225/8 267/16 5
/16 511/8 169/16 1715/16 1047
300DLFU622 22 30 44 231/8 323/16 117/8 225/8 267/16 5
/16 511/8 169/16 1715/16 1107
THREE 12 300DLFU630 30 40 491/8 275/16 355/16 1313/16 2513/16 341/8 5
/16 6013/16 1911/16 245/16 1733
300DLFU637 37 50 491/8 275/16 355/16 1313/16 2513/16 341/8 5
/16 641/8 1911/16 253/16 1795
300DLFU645 45 60 491/8 275/16 355/16 1313/16 2513/16 341/8 5
/16 641/8 1911/16 253/16 1876

Dimensions: mm
SIZE OUTPUT PUMP & MOTOR WEIGHT
PHASE MODEL kg
ø kW HP A B C D E F G H J L
300DLFU618 18.5 25 1118 587 817 302 575 671 8 1298 420 455 475
300DLFU622 22 30 1118 587 817 302 575 671 8 1298 420 455 502
THREE 300 300DLFU630 30 40 1248 693 897 351 656 867 8 1544 500 618 786
300DLFU637 37 50 1248 693 897 351 656 867 8 1629 500 639 814
300DLFU645 45 60 1248 693 897 351 656 867 8 1629 500 639 851

EBARA Fluid Handling


www.pumpsebara.com 2-197
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector
50DLFU, 2HP
2 / (65) 31 / (800) 9 1
29/16 (65)
80DLFU, 2HP 16 2

29/16 (65)
100DLFU, 2 to 5HP
G

279/16 (700)
F
13/8 (35)

29/16 (65)
Manhole dimensions in
Guide pipe support floor frame installation Floor Frame
5 /2 (140)
1
Bolt 2– /2 x 1 /16
1 3
19/16 (40)
39/16 (90)
23/8 (60) (12x30)
115/16 (50)
23/4 (70)

Submersible Cable
2 /4 (70)
3
23/16 (56) f
e
Guide pipe length

SGP (W) 1" ø

t
M1 N1 Q
N2 (n) QTY - (h) HOLES
M2
P.C

ø
Flange (ANSI 125 PSI F.F)
T
.D.
J

L . W. L. inch
ø e f t n h
ø1 2 43/4 6 5
/8 4 3
/4
R

3 6 71/2 3
/4 4 3
/4
S
P

4 71/2 9 15
/16 8 3
/4
U

4 – H Holes mm
C
ø e f t n h
B A 50 121 152 16 4 19
Bolt 2 – /8 (16) 5
80 152 191 19 4 19
315/16
100 191 229 24 8 19
(100)
Dimensions: inch
OUTPUT QDC QDC PUMP & MOTOR WEIGHT Lb
PHASE SIZE
ø MODEL MODEL
kW HP A B C H J M1 M2 N1 N2 P R S ø1 F G L Q T U PUMP QDC
2/3 50DLFU61.5 1.5 2 LM65 87/16 6 33/4 1
/2 51/2 65/16 33/4 43/4 13/4 511/16 913/16 71/2 21/2 101/8 181/4 81/4 71/16 295/8 115/16 132 31
80DLFU61.5 1.5 2 LM80 87/16 65/8 39/16 9
/16 61/8 61/2 39/16 415/16 115/16 67/8 111/4 91/16 3 111/2 201/8 95/8 81/4 311/16 29/16 148 37
THREE 3/4 100DLFU61.5 1.5 2 LM80 87/16 81/4 39/16 9
/16 61/8 711/16 39/16 415/16 115/16 67/8 1113/16 91/16 3 101/2 197/16 95/8 77/8 307/8 1 170 37
100DLFU62.2 2.2 3 LM80 87/16 81/4 39/16 9
/16 61/8 711/16 39/16 415/16 115/16 67/8 1113/16 91/16 3 111/8 201/2 95/8 811/16 313/4 1 198 37
100DLFU63.7 3.7 5 LM80 87/16 81/4 39/16 9
/16 61/8 711/16 39/16 415/16 115/16 67/8 1113/16 91/16 3 111/8 201/2 95/8 811/16 333/8 1 216 37

Dimensions: mm
OUTPUT QDC QDC PUMP & MOTOR WEIGHT kg
PHASE SIZE
ø MODEL
kW HP MODEL A B C H J M1 M2 N1 N2 P R S ø1 F G L Q T U PUMP QDC
50/80 50DLFU61.5 1.5 2 LM65 215 153 95 12 140 160 95 120 45 145 250 190 65 257 464 210 180 753 50 60 14
80DLFU61.5 1.5 2 LM80 215 168 90 15 155 165 90 125 50 175 285 230 80 292 511 245 210 789 65 67 17
THREE 80/100 100DLFU61.5 1.5 2 LM80 215 210 90 15 155 195 90 125 50 175 300 230 80 267 494 245 200 785 25 77 17
100DLFU62.2 2.2 3 LM80 215 210 90 15 155 195 90 125 50 175 300 230 80 282 521 245 220 807 25 90 17
100DLFU63.7 3.7 5 LM80 215 210 90 15 155 195 90 125 50 175 300 230 80 282 521 245 220 847 25 98 17
*Note: All 80DLFU dimensions are based on 3'' discharge.
All 100DLFU dimensions are based on 4'' discharge.
EBARA Fluid Handling
www.pumpsebara.com 2-198
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector
80DLMFU, 2 to 71/2HP
29/16 (65) 311/2 (800) 29/16 (65)

29/16 (65)
G
13/8 (35)

279/16 (700)
F
Guide pipe support

29/16 (65)
51/2 (140) Bolt 2– /2 x 1 /16
1 3
39/16 (90)

Floor Frame
19/16 (40)

23/8 (60) (12x30)


Manhole dimensions
floor frame installation
Submersible Cable
115/16 (50)
23/4 (70)

23/4 (70) 23/16 (56)


Guide pipe length

SGP (W) 1"

m 415/16 (125) Q
4 - 9/16 (15)Holes
3 /16 (90)
9
115/16 (50)
P.C f
.D. e
T

61
/8 ( ø
155 ø
)
L . W. L.

t
91/16 (230)

0)
67/8 (175)

3 (8 (n) QTY - (h) HOLES


L
r

Flange (ANSI 125 PSI F.F)


29/16 (65)

39/16 (90)
Bolt 2 – 5/8 (16)
6 /4 (171) 87/16 (215)
3
inch
ø e f t n h r m
315/16 (100) 3 6 71/2 3
/4 4 3
/4 113/16 61/2
4 71/2 9 15
/16 8 3
/4 1113/16 711/16
mm
ø e f t n h r m
80 152 191 19 4 19 284 165
100 191 229 24 8 19 300 195
Dimensions: inch
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT Lb
PHASE SIZE
ø PUMP MODEL
MODEL
kW HP F G L Q T PUMP Q.D.C.
80DLMFU61.5 1.5 2 LM80 111/2 205/16 913/16 81/4 311/16 157 37
80DLMFU62.2 2.2 3 LM80 111/2 205/16 915/16 81/4 321/16 187 37
THREE 3/4
80DLMFU63.7 3.7 5 LM80 121/8 21 915/16 811/16 335/8 205 37
80DLMFU65.5 5.5 71/2 LM80 1215/16 22 127/8 91/4 3815/16 311 37

Dimensions: mm
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT kg
PHASE SIZE
ø PUMP MODEL
MODEL
kW HP F G L Q T PUMP Q.D.C.
80DLMFU61.5 1.5 2 LM80 292 516 250 210 789 71 17
80DLMFU62.2 2.2 3 LM80 292 516 253 210 815 85 17
THREE 80/100
80DLMFU63.7 3.7 5 LM80 308 534 252 220 854 93 17
80DLMFU65.5 5.5 71/2 LM80 328 559 327 235 989 141 17

EBARA Fluid Handling


www.pumpsebara.com 2-199
(t) 803 327 5005 • (f) 803 327 5097 rev. 11/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector
80DLCMFU, 10 to 15HP
29/16 (65) 311/2 (800) 29/16 (65)

29/16 (65)
G
23/16 (55)

279/16 (700)
F

29/16 (65)
Guide pipe support
Floor Frame

9 /16 (246)
11 Bolt 2–5/8 x 13/16 Manhole dimensions in
(16x30) floor frame installation
57/8 (150)
Submersible Cable

33/8 (85)
23/4 (70)
315/16 (100)

65/16 (160)
Guide pipe length

SGP (W) 11/2"


T

4 – 9/16 (15)Holes 715/16 (185)


m Q
P.C 43/4 (120) 31/8 (80)
.D. ø
6 /18
(155
) f
L . W. L.
3 (80
) e
ø
101/16 (255)

97/16 (240)
r

t
(n) QTY - (h) HOLES
61/2 (165) 23/16 (55)
U

71/16 (180)
Bolt 2 – 5/8 (16) 63/4 (171) 12 (305) Flange (ANSI 125 PSI F.F)
inch
ø e f t n h r m
3 6 71/2 3
/4 4 3
/4 133/4 711/16
4 71/2 9 15
/16 8 3
/4 143/8 87/8
mm
ø e f t n h r m
80 152 191 19 4 19 350 195
100 191 229 24 8 19 365 226
Dimensions: inch
SIZE OUTPUT Q.D.C. PUMP & MOTOR WEIGHT Lb
PHASE ø MODEL
kW HP MODEL F G L Q T U PUMP Q.D.C.
80DLCMFU67.5 7.5 10 LL80 1415/16 273/16 111/8 101/4 375/16 111/16 375 97
THREE 3/4 80DLCMFU611 11 15 LL80 1511/16 283/8 111/4 11 411/16 13/4 500 97

Dimensions: mm
SIZE OUTPUT Q.D.C. PUMP & MOTOR WEIGHT Lb
PHASE ø MODEL
kW HP MODEL F G L Q T U PUMP Q.D.C.
80DLCMFU67.5 7.5 10 LL80 379 690 283 260 948 43 170 44
THREE 80/100
80DLCMFU611 11 15 LL80 399 720 285 280 1043 45 227 44

EBARA Fluid Handling


www.pumpsebara.com 2-200
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector
80DLFU, 3 to 30HP 2 / (65) 31 / (800) 9
16
1
2 29/16 (65)

29/16 (65)
G
23/16 (55)

279/16 (700)
F

29/16 (65)
Guide pipe support
Floor Frame
9 /16 (246)
11 Bolt 2–5/8 x 13/16 Manhole dimensions in
(16x30) floor frame installation
57/8 (150)
Submersible Cable
315/16 (100)
23/4 (70)

33/8 (85) f
e
Guide pipe length

65/16 (160) ø
SGP (W) 11/2"

t
4 – 3/4 (19) Holes (n) QTY - (h) HOLES
81/4 (210) 75/16 (185) Q
P.C
T

.D.
6 /78
ø 41/8 (105) 31/8 (80) Flange (ANSI 125 PSI F.F)
(17
5) inch
) L.W.L.
ø 4 (100 ø e f t n h
3 6 71/2 /4 4 /4
143/8 (365)

3 3
107/16 (265)
97/16 (240)

4 71/2 9 15
/16 8 3
/4
L

mm
U

ø e f t n h
61/2 (165) 23/16 (55)
80 152 191 19 4 19
Bolt 4 – 5/8 (16) 81/4 (210) 117/16 (290)
71/16 (180) 100 191 229 24 8 19

Dimensions: inch
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT Lb
PHASE SIZE
ø MODEL
MODEL
kW HP F G L Q T U PUMP Q.D.C.
80DLFU62.2 2.2 3 LL100 133/16 253/8 125/8 91/4 343/4 41/2 209 101
80DLFU63.7 3.7 5 LL100 133/16 253/8 125/8 91/4 365/16 41/2 209 101
80DLFU65.5 5.5 71/2 LL100 133/16 253/8 159/16 91/4 415/8 41/2 317 101
80DLFU67.5 7.5 10 LL100 141/2 269/16 1113/16 913/16 3711/16 15/8 344 101
THREE 3/4
80DLFU611 11 15 LL100 153/16 2711/16 115/8 105/8 415/16 15/8 470 101
80DLFU615 15 20 LL100 153/16 2711/16 123/8 105/8 441/8 15/8 564 101
80DLFU618 18.5 25 LL100 1513/16 283/4 123/8 117/16 4511/16 15/8 639 101
80DLFU622 22 30 LL100 1513/16 283/4 123/8 117/16 4511/16 15/8 694 101

Dimensions: mm
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT kg
PHASE SIZE
ø MODEL
MODEL
kW HP F G L Q T U PUMP Q.D.C.
80DLFU62.2 2.2 3 LL100 335 644 320 235 883 115 95 46
80DLFU63.7 3.7 5 LL100 335 644 320 235 923 115 95 46
80DLFU65.5 5.5 71/2 LL100 335 644 395 235 1058 115 144 46
80DLFU67.5 7.5 10 LL100 369 675 300 250 958 42 156 46
THREE 80/100
80DLFU611 11 15 LL100 385 703 295 270 1050 42 213 46
80DLFU615 15 20 LL100 385 703 315 270 1120 42 256 46
80DLFU618 18.5 25 LL100 402 730 315 290 1160 42 290 46
80DLFU622 22 30 LL100 402 730 315 290 1160 42 315 46

EBARA Fluid Handling


www.pumpsebara.com 2-201
(t) 803 327 5005 • (f) 803 327 5097 rev. 12/03
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector
100DLMFU, 3 to 30HP 2 / (65) 31 / (800) 2/ 9
16
1
2
9
16 (65)

29/16 (65)
G
23/16 (55)

279/16 (700)
F

29/16 (65)
Guide pipe support
Floor Frame

9 /16 (246)
11 Bolt 2–5/8 x 13/16 Manhole dimensions in
57/8 (150) (16x30) floor frame installation
315/16 (100)

Submersible Cable

f
23/4 (70)

33/8 (85)
e
ø
Guide pipe length

65/16 (160)
SGP (W) 11/2"

t
4 – 3/4 (19) Holes (n) QTY - (h) HOLES
P.C
81/4 (210) 75/16 (185) Q
.D. ø 41/8 (105) 31/8 (80)
Flange (ANSI 125 PSI F.F)
T

6 /78
(175
) inch
0) L.W.L.
ø 4 (10 ø e f t n h
14 /8 (365)

3 6 71/2 3
/4 4 3
/4
107/16 (265)
97/16 (240)

4 71/2 9 15
/16 8 3
/4
L
3

6 91/2 11 1 8 3
/4
61/2 (165) 23/16 (55)
U

mm
71/16 (180) Bolt 4 – 5/8 (16) 81/4 (210) 117/16 (290) ø e f t n h
80 152 191 19 4 19
100 191 229 24 8 19
150 240 280 24 8 19
Dimensions: inch
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT Lb
PHASE SIZE
ø MODEL
MODEL
kW HP F G L Q T U PUMP Q.D.C.
100DLMFU62.2 2.2 3 LL100 133/16 253/8 125/8 91/4 343/4 41/2 209 101
100DLMFU63.7 3.7 5 LL100 133/16 253/8 125/8 91/4 365/16 41/2 209 101
100DLMFU65.5 5.5 71/2 LL100 133/16 253/8 15 /16
9
91/4 415/8 41/2 317 101
3
100DLMFU67.5 7.5 10 LL100 141/2 269/16 1113/16 913/16 3711/16 15/8 344 101
THREE 4
100DLMFU611 11 15 LL100 153/16 2711/16 115/8 105/8 415/16 15/8 470 101
6
100DLMFU615 15 20 LL100 153/16 2711/16 123/8 105/8 441/8 15/8 564 101
100DLMFU618 18.5 25 LL100 1513/16 283/4 12 /8
3
117/16 4511/16 15/8 639 101
100DLMFU622 22 30 LL100 1513/16 283/4 123/8 117/16 4511/16 15/8 694 101

Dimensions: mm
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT kg
PHASE SIZE
ø MODEL
MODEL
kW HP F G L Q T U PUMP Q.D.C.
100DLMFU62.2 2.2 3 LL100 335 644 320 235 883 115 95 46
100DLMFU63.7 3.7 5 LL100 335 644 320 235 923 115 95 46
100DLMFU65.5 5.5 71/2 LL100 335 644 395 235 1058 115 144 46
80
100DLMFU67.5 7.5 10 LL100 369 675 300 250 958 42 156 46
THREE 100
150 100DLMFU611 11 15 LL100 385 703 295 270 1050 42 213 46
100DLMFU615 15 20 LL100 385 703 315 270 1120 42 256 46
100DLMFU618 18.5 25 LL100 402 730 315 290 1160 42 290 46
100DLMFU622 22 30 LL100 402 730 315 290 1160 42 315 46

EBARA Fluid Handling


www.pumpsebara.com 2-201.1
(t) 803 327 5005 • (f) 803 327 5097 rev. 03/13
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector
100DLFU, 71/2 to 30HP   
        

  
*

  
)



  
  


*XLGH3LSH6XSSRUW


   0DQKROHGLPHQVLRQVLQ
   IORRUIUDPHLQVWDOODWLRQ
   %ROW [  
   )ORRU)UDPH
>[@

6XEPHUVLEOH&DEOH

6*3 : 
  

  





  
*XLGHSLSHOHQJWK

P

 
f
     
e
7
3
&

  4 ø
'



 

 >@+ROHV



t
/:/

(n) QTY - (h) HOLES


  

  
U

  N
/

 0 


;
8

Flange (ANSI 125 PSI F.F)





  

  
inch

  %ROW >@ ø e f t n h r m k

   4 71/2 9 15
/16 8 3
/4 1711/16 1213/16 95/8
6 91/2 11 1 8 7
/8 185/16 139/16 113/8
mm
ø e f t n h r m m
100 191 229 24 8 19 450 326 245
150 241 279 25 8 22 465 345 290
Dimensions: inch
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT Lb
PHASE SIZE
ø MODEL
MODEL
kW HP F G L Q T U PUMP Q.D.C.
100DLFU65.5 5.5 71/2 LL125 1511/16 2613/16 143/8 11 403/16 211/16 353 143
100DLFU67.5 7.5 10 LL125 1511/16 2613/16 143/8 11 403/16 211/16 395 143
100DLFU611 11 15 LL125 1511/16 2613/16 143/8 11 4313/16 211/16 476 143
THREE 4/6
100DLFU615 15 20 LL125 167/16 28 145/8 1113/16 463/16 27/8 602 143
100DLFU618 18.5 25 LL125 171/4 293/16 145/8 125/8 473/4 27/8 677 143
100DLFU622 22 30 LL125 171/4 293/16 145/8 125/8 473/4 27/8 736 143

Dimensions: mm
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT kg
PHASE SIZE
ø MODEL
MODEL
kW HP F G L Q T U PUMP Q.D.C.
100DLFU65.5 5.5 71/2 LL125 398 681 366 280 1021 69 160 65
100DLFU67.5 7.5 10 LL125 398 681 366 280 1021 69 179 65
100DLFU611 11 15 LL125 398 681 366 280 1114 69 216 65
THREE 100/150
100DLFU615 15 20 LL125 418 711 372 300 1173 73 273 65
100DLFU618 18.5 25 LL125 438 741 372 320 1213 73 307 65
100DLFU622 22 30 LL125 438 741 372 320 1213 73 334 65

EBARA Fluid Handling


www.pumpsebara.com 2-202
(t) 803 327 5005 • (f) 803 327 5097 rev. 04/15
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector
100DLFU, 40 to 60HP
  
        

*

  


  

*XLGH3LSH6XSSRUW
 
 %ROW [  
  

     
>[@

)



  
  


0DQKROHGLPHQVLRQVLQ
IORRUIUDPHLQVWDOODWLRQ
)ORRU)UDPH
  

 6XEPHUVLEOH&DEOH
   
  


/:/
6*3 : 
*XLGHSLSHOHQJWK

P
4
 
     

 
f
7
3
&

  
/

e
'

  

 

+ROHV ø



 

t
  
U

(n) QTY - (h) HOLES


  

 N
0


;
Flange (ANSI 125 PSI F.F)
8


  
%ROW >@       inch
 

  
ø e f t n h r m k
4 71/2 9 15
/16 8 3
/4 1711/16 1213/16 95/8
6 91/2 11 1 8 7
/8 185/16 139/16 113/8
mm
ø e f t n h r m m
100 191 229 24 8 19 450 325 245
150 241 279 25 8 22 465 345 290

Dimensions: inch
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT Lb
PHASE SIZE
ø MODEL
MODEL
kW HP F G L Q T U PUMP Q.D.C.
100DLFU630 30 40 LL125HH 199/16 357/8 4711/16 143/16 541/16 63/16 1001 183
THREE 4 100DLFU637 37 50 LL125HH 199/16 357/8 513/16 143/16 579/16 63/16 1171 183
100DLFU645 45 60 LL125HH 199/16 357/8 513/16 143/16 579/16 63/16 1219 183

Dimensions: mm
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT kg
PHASE SIZE
ø MODEL
MODEL
kW HP F G L Q T U PUMP Q.D.C.
100DLFU630 30 40 LL125HH 497 911 1211 360 1373 157 454 83
THREE 100 100DLFU637 37 50 LL125HH 497 911 1301 360 1462 157 531 83
100DLFU645 45 60 LL125HH 497 911 1301 360 1462 157 553 83

EBARA Fluid Handling


www.pumpsebara.com 2-203
(t) 803 327 5005 • (f) 803 327 5097 rev. 04/15
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector
150DLFU, 10 to 30HP
29/16 (65) 435/16 (1100) 29/16 (65)

29/16 (65)
G
115/16 (50)

311/2 (800)
F

29/16 (65)
Guide pipe support
Floor Frame
Bolt 2–5/8 x 13/16
19/16 (40)

109/16 (268) Manhole dimensions in


(16x30) floor frame installation
5 7/8(150)
39/16 (90)

Submersible Cable
315/16 (100)
23/4 (70)

65/16 (160) 39/16 (90)


Guide pipe length

SGP (W) 2"


f
14 (355)
e
81/16 61/8 Q ø
(205) (155)

t
P.C

ø (n) QTY - (h) HOLES


.D.

4 – 3/4 (19) Holes


T
9
13 16
/

L . W. L. Flange (ANSI 125 PSI F.F)


inch
ø e f t n h
191/2 (495)

ø6
15 /16 (405)

(15 6 91/2 11 1 8 7
/8
125/8 (320)

0)
8 113/4 131/2 11/8 8 7
/8
15

mm
U

Bolt 4–5/8 811/16 (220) 611/16 (170) ø e f t n h


1113/16 (300) (16) 123/8 (315) 143/16 (360) 150 241 279 25 8 22
200 298 343 29 8 22
Dimensions: inch
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT Lb
PHASE SIZE
ø MODEL
MODEL
kW HP F G L Q T U PUMP Q.D.C.
150DLFU67.5 7.5 10 LL150 1615/16 287/16 159/16 1113/16 4111/16 33/16 428 176
150DLFU611 11 15 LL150 1615/16 287/16 159/16 1113/16 453/8 33/16 549 176
THREE 6/8 150DLFU615 15 20 LL150 1713/16 295/8 16 /16
1
125/8 475/8 33/8 635 176
150DLFU618 18.5 25 LL150 1713/16 295/8 161/16 125/8 493/16 33/8 712 176
150DLFU622 22 30 LL150 187/8 3015/16 15 /16
15
133/8 491/16 35/16 787 176

Dimensions: mm
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT kg
PHASE SIZE
ø MODEL
MODEL
kW HP F G L Q T U PUMP Q.D.C.
150DLFU67.5 7.5 10 LL150 430 722 396 300 1059 81 194 80
150DLFU611 11 15 LL150 430 722 396 300 1152 81 249 80
THREE 150/200 150DLFU615 15 20 LL150 453 753 408 320 1209 85 288 80
150DLFU618 18.5 25 LL150 453 753 408 320 1249 85 323 80
150DLFU622 22 30 LL150 479 786 405 340 1246 84 357 80

EBARA Fluid Handling


www.pumpsebara.com 2-204
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector
200DLFU, 10 to 30HP
29/16 (65) 435/16 (1100) 29/16 (65)

29/16 (65)
G
115/16 (50)

311/2 (800)
F

29/16 (65)
Guide pipe support
Floor Frame
Bolt 2–5/8 x 13/16
19/16 (40)

109/16 (268) Manhole dimensions in


(16x30) floor frame installation
57/8(150)
39/16 (90)

Submersible Cable
23/4 (70)

315/16 (100)

65/16 (160) 39/16 (90)


Guide pipe length

SGP (W) 2"


f
14 (355) e
ø
81/16 61/8 Q
(205) (155)

t
(n) QTY - (h) HOLES
P.C

ø
.D.

4 – 3/4 (19) Holes


T
9
13 16

Flange (ANSI 125 PSI F.F)


/

L . W. L.
inch
ø e f t n h
ø6
191/2 (495)
1515/16 (405)

(15 6 91/2 11 1 8 7
/8
125/8 (320)

0) 8 113/4 131/2 11/8 8 7


/8
mm
U

ø e f t n h
Bolt 4– / 5
8 8 /16 (220) 6 / (170)
11 11
16
150 241 279 25 8 22
1113/16 (300) (16) 123/8 (315) 143/16 (360) 200 298 343 29 8 22
Dimensions: inch
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT Lb
PHASE SIZE
ø MODEL
MODEL
kW HP F G L Q T U PUMP Q.D.C.
200DLFU67.5 7.5 10 LL150 1615/16 287/16 159/16 1113/16 4111/16 33/16 428 176
200DLFU611 11 15 LL150 1615/16 287/16 159/16 1113/16 453/8 33/16 549 176
THREE 6/8 200DLFU615 15 20 LL150 1713/16 295/8 16 /16
1
125/8 475/8 33/8 635 176
200DLFU618 18.5 25 LL150 1713/16 295/8 161/16 125/8 493/16 33/8 712 176
200DLFU622 22 30 LL150 187/8 3015/16 15 /16
15
133/8 491/16 35/16 787 176

Dimensions: mm
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT kg
PHASE SIZE
ø MODEL
MODEL
kW HP F G L Q T U PUMP Q.D.C.
200DLFU67.5 7.5 10 LL150 430 722 396 300 1059 81 194 80
200DLFU611 11 15 LL150 430 722 396 300 1152 81 249 80
THREE 150/200 200DLFU615 15 20 LL150 453 753 408 320 1209 85 288 80
200DLFU618 18.5 25 LL150 453 753 408 320 1249 85 323 80
200DLFU622 22 30 LL150 479 786 405 340 1246 84 357 80

EBARA Fluid Handling


www.pumpsebara.com 2-205
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector
150DLFU, 40 to 60HP
200DLFU, 40 to 60HP
G
Floor Frame

E1
E2
F
Bolt 2–5/8 x 13/16 D1
(16x30) D2
Floor plate
45/16 (110)
19/16 (40)

57/8 (150) Guide pipe support


/16 (5)
3

SGP (W) 2"


N 39/16 (90)

65/16 (160)
f
e
P Q ø
T

6 /8 (155)
1

t
ø (n) QTY - (h) HOLES
L . W. L.
Flange (ANSI 125 PSI F.F)
23/8 (60)

inch
L
R
S

ø e f t n h
U
123/8 (315)

6 91/2 11 1 8 7
/8
A1 8 113/4 131/2 11/8 8 7
/8
B1
315/16 mm
(100) Bolt 4 – 15/16 (24) ø e f t n h
A2
B2 150 241 279 25 8 22
200 298 343 29 8 22
Dimensions: inch
OUTPUT QDC PUMP & MOTOR ACCESS HOLE WEIGHT Lb
PHASE SIZE
ø MODEL
kW HP MODEL A1 A2 B1 B2 F G L N P Q R S T U D1 D2 E1 E2 PUMP QDC
150DLFU630 30 40 LL150YU 161/8 143/16 201/2 161/8 189/16 315/16 1513/16 91/4 1213/16 197/8 1911/16 153/16 471/16 51/4 393/4 447/8 279/16 3211/16 1294 179
6 150DLFU637 37 50 LL150YU 161/8 143/16 201/2 161/8 189/16 315/16 165/8 91/4 1213/16 197/8 1911/16 153/16 503/8 51/4 393/4 447/8 279/16 3211/16 1345 179
THREE 150DLFU645 45 60 LL150YU 161/8 143/16 201/2 161/8 189/16 315/16 165/8 91/4 1213/16 197/8 1911/16 153/16 503/8 51/4 393/4 447/8 279/16 3211/16 1404 179
200DLFU630 30 40 LL200YU 175/16 169/16 215/8 181/2 209/16 321/2 171/2 107/16 14 201/4 235/8 163/4 471/16 67/8 435/16 487/16 311/2 365/8 1347 227
8 200DLFU637 37 50 LL200YU 175/16 169/16 215/8 181/2 209/16 321/2 185/16 107/16 14 201/4 235/8 163/4 503/8 67/8 435/16 487/16 311/2 365/8 1398 227
200DLFU645 45 60 LL200YU 175/16 169/16 215/8 181/2 209/16 321/2 185/16 107/16 14 201/4 235/8 163/4 503/8 67/8 435/16 487/16 311/2 365/8 1457 227

Dimensions: mm
OUTPUT QDC PUMP & MOTOR ACCESS HOLE WEIGHT kg
PHASE SIZE
ø MODEL
kW HP MODEL A1 A2 B1 B2 F G L N P Q R S T U D1 D2 E1 E2 PUMP QDC
150DLFU630 30 40 LL150YU 410 360 520 410 471 795 402 235 325 505 500 385 1195 133 1010 1140 700 830 587 81
150 150DLFU637 37 50 LL150YU 410 360 520 410 471 795 423 235 325 505 500 385 1280 133 1010 1140 700 830 610 81
THREE 150DLFU645 45 60 LL150YU 410 360 520 410 471 795 423 235 325 505 500 385 1280 133 1010 1140 700 830 637 81
200DLFU630 30 40 LL200YU 440 420 550 470 522 825 444 265 355 515 600 425 1195 175 1100 1230 800 930 611 103
200 200DLFU637 37 50 LL200YU 440 420 550 470 522 825 465 265 355 515 600 425 1280 175 1100 1230 800 930 634 103
200DLFU645 45 60 LL200YU 440 420 550 470 522 825 465 265 355 515 600 425 1280 175 1100 1230 800 930 661 103

EBARA Fluid Handling


www.pumpsebara.com 2-206
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector
250DLFU, 15 to 30HP

29/16 (65) 471/4 (1200) 29/16 (65)

29/16 (65)
Manhole dimensions in
floor frame installation
G

357/16 (900)
F
Floor Frame

29/16 (65)
Bolt 2–5/8 x 13/16 77/8 (200)
/16 (30)

(16x30)
13

315/16 (100)

Submersible Cable
Guide pipe length

4 /4 (120)
3

97/16 (240) SGP (W) 3"

f
17 / (435)
1
8 7 /16
11 Q e
(195) ø
ø

t
T

L . W. L. (n) QTY - (h) HOLES


Bolt 4 – 13/16 (30)
279/16 (700)

Flange (ANSI 125 PSI F.F)


175/16 (440)
133/4 (350)

inch
ø e f t n h
U
153/4 (400)

1911/16 (500)
10 141/4 16 13/16 12 1
235/8 (600) 259/16 (650) mm
317/8 (810) ø e f t n h
250 362 406 30 12 25

Dimensions: inch
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT Lb
PHASE SIZE
ø MODEL
MODEL
kW HP F G L Q T U PUMP Q.D.C.
250DLFU611 11 15 LL250U 205/8 357/16 173/4 149/16 471/2 25/16 736 331
250DLBFU615 15 20 LL250U 205/8 357/16 187/16 149/16 4915/16 25/16 833 331
THREE 10 250DLCFU615 15 20 LL250U 215/16 363/8 181/8 153/8 4911/16 113/16 877 331
250DLFU618 18.5 25 LL250U 215/16 363/8 181/8 153/8 511/4 113/16 959 331
250DLFU622 22 30 LL250U 215/16 363/8 181/8 153/8 511/4 113/16 1030 331

Dimensions: mm
OUTPUT Q.D.C. PUMP & MOTOR WEIGHT kg
PHASE SIZE
ø MODEL
MODEL
kW HP F G L Q T U PUMP Q.D.C.
250DLFU611 11 15 LL250U 524 900 451 370 1207 58 334 150
250DLBFU615 15 20 LL250U 524 900 468 370 1269 58 378 150
THREE 250 250DLCFU615 15 20 LL250U 541 924 461 390 1262 46 398 150
250DLFU618 18.5 25 LL250U 541 924 461 390 1302 46 435 150
250DLFU622 22 30 LL250U 541 924 461 390 1302 46 467 150

EBARA Fluid Handling


www.pumpsebara.com 2-207
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector
250DLFU, 40 TO 60HP
300DLFU, 40 TO 60HP

Floor Frame
G

E2
E1
F
Bolt 2–5/8 x 13/16 D1
(16x30) D2

Floor plate
45/16 (110)
19/16 (40)

57/8 (150) Guide pipe support


(5)
/16
3

N 43/4 (120)

SGP (W) 3" f


97/16 (240) e
ø
P Q

t
T

6 /8 (155)
1

ø (n) QTY - (h) HOLES

L . W. L. Flange (ANSI 125 PSI F.F)


inch
23/8 (60)

ø e f t n h
S

10 141/4 16 13/16 12 1
U

12 17 19 11/4 12 1
123/8 (315)

A1
31/8 (80)

B1
mm
315/16
Bolt 4 – 13/16 (30) ø e f t n h
(100)
250 362 406 30 12 25
300 432 483 32 12 25
Dimensions: inch
OUTPUT QDC PUMP & MOTOR ACCESS HOLE WEIGHT Lb
PHASE SIZE
ø MODEL MODEL
kW HP A1 A2 B1 B2 F G L N P Q R S T U D1 D2 E1 E2 PUMP QDC
250DLFU630 30 40 LL250YU 259/16 1911/16 311/8 221/16 2311/16 393/4 179/16 123/8 171/8 25 279/16 175/16 483/8 83/4 471/4 531/8 357/16 415/16 1570 344
10 250DLFU637 37 50 LL250YU 259/16 1911/16 311/8 221/16 2311/16 393/4 183/8 123/8 171/8 25 279/16 175/16 513/4 83/4 471/4 531/8 357/16 415/16 1631 344
THREE 250DLFU645 45 60 LL250YU 259/16 1911/16 311/8 221/16 2311/16 393/4 183/8 123/8 171/8 25 279/16 175/16 513/4 83/4 471/4 531/8 357/16 415/16 1713 344
300DLFU630 30 40 LL300YU 263/4 2213/16 325/16 253/16 275/16 437/8 207/8 139/16 185/16 273/8 311/2 215/8 509/16 915/16 513/16 571/16 393/8 451/4 1733 450
12 300DLFU637 37 50 LL300YU 263/4 2213/16 325/16 253/16 275/16 437/8 213/4 139/16 185/16 273/8 311/2 215/8 537/8 915/16 513/16 571/16 393/8 451/4 1795 450
300DLFU645 45 60 LL300YU 263/4 2213/16 325/16 253/16 275/16 437/8 213/4 139/16 185/16 273/8 311/2 215/8 537/8 915/16 513/16 571/16 393/8 451/4 1876 450

Dimensions: mm
OUTPUT QDC PUMP & MOTOR ACCESS HOLE WEIGHT kg
PHASE SIZE
ø MODEL MODEL
kW HP A1 A2 B1 B2 F G L N P Q R S T U D1 D2 E1 E2 PUMP QDC
250DLFU630 30 40 LL250YU 650 500 790 560 602 1010 446 315 435 635 700 440 1229 223 1200 1350 900 1050 712 156
250 250DLFU637 37 50 LL250YU 650 500 790 560 602 1010 467 315 435 635 700 440 1314 223 1200 1350 900 1050 740 156
THREE 250DLFU645 45 60 LL250YU 650 500 790 560 602 1010 467 315 435 635 700 440 1314 223 1200 1350 900 1050 777 156
300DLFU630 30 40 LL300YU 680 580 820 640 693 1115 531 345 465 695 800 550 1284 253 1300 1450 1000 1150 786 204
300 300DLFU637 37 50 LL300YU 680 580 820 640 693 1115 552 345 465 695 800 550 1369 253 1300 1450 1000 1150 814 204
300DLFU645 45 60 LL300YU 680 580 820 640 693 1115 552 345 465 695 800 550 1369 253 1300 1450 1000 1150 851 204

EBARA Fluid Handling


www.pumpsebara.com 2-208
(t) 803 327 5005 • (f) 803 327 5097 rev. 07/03
EBARA Submersible Sewage Pumps DLFU
Dimensions
Project: Model: Chk’d: Date:
Model DLFU with Quick Discharge Connector
300DLFU, 25 to 30HP

215/16 (75) 471/4 (1200) 215/16 (75)


Manhole dimensions in

215/16 (75)
floor frame installation
G

357/16 (900)
F

215/16 (75)
Floor Frame
Bolt 2–5/8 x 13/16 77/8 (200)
13/16 (30)

(16x30)
315/16 (100)

43/4 (120) Submersible Cable


Guide pipe length

97/16 (240) SGP (W) 3"

185/16 (465) 711/16 Q


(195)
f
e
T

ø ø
L . W. L.
Bolt 4 – 13/16 (30)
t
(n) QTY - (h) HOLES
311/2 (800)
215/8 (550)
1615/16 (430)

Flange (ANSI 125 PSI F.F)


U
153/4 (400)

2213/16 (580) inch


253/16 (640) 263/4 (680) ø e f t n h
331/16 (840) 12 17 19 11/4 12 1
mm
ø e f t n h
300 432 483 32 12 25
Dimensions: inch
SIZE OUTPUT Q.D.C. PUMP & MOTOR WEIGHT Lb
PHASE ø MODEL
kW HP MODEL F G L Q T U PUMP Q.D.C.
300DLFU618 18.5 25 LL300U 231/8 3811/16 225/16 169/16 553/8 45/16 1047 331
THREE 12
300DLFU622 22 30 LL300U 231/8 3811/16 225/16 169/16 553/8 45/16 1107 331

Dimensions: mm
SIZE OUTPUT Q.D.C. PUMP & MOTOR WEIGHT kg
PHASE ø MODEL
kW HP MODEL F G L Q T U PUMP Q.D.C.
300DLFU618 18.5 25 LL300U 587 983 566 420 1407 109 475 150
THREE 300
300DLFU622 22 30 LL300U 587 983 566 420 1407 109 502 150

EBARA Fluid Handling


www.pumpsebara.com 2-209
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Sectional View
Project: Model: Chk’d: Date:
2 to 5HP

924 811 200


1

838
811
115 2
4
120
817 7

120
115 6
3
849 814
2

876 830

849 801

909 802

120
193 5
2
115 120
2 4

120 816
3
193
213 1
115
1
120
2

174 005

117

021

080
120 012 001 111
1 125 039

PART ASTM, AISI NO. FOR PART ASTM, AISI NO. FOR
NO. PART NAME MATERIAL CODE 1 UNIT NO. PART NAME MATERIAL CODE 1 UNIT
001 CASING CAST IRON A48 Class 30 1 174 DISCHARGE ELBOW CAST IRON A48 Class 30 1
005 INTERMEDIATE CASING CAST IRON A48 Class 30 1 193-1 PLUG 304 STAINLESS AISI304 1
†012 SUCTION COVER CAST IRON A48 Class 30 1 193-2 PLUG 304 STAINLESS AISI304 1
†021 IMPELLER CAST IRON A48 Class 30 1 200 LIFTING HANGER STEEL A283 Grade D 1
039 KEY 420 STAINLESS AISI420 1 213 AIR VENT VALVE BRASS B36 No. 272 1
080 BUSHING STEEL A283 Grade D 1 801 ROTOR — 1
†111 MECHANICAL SEAL — 1 SET 802 STATOR — 1
†115-1 O-RING RUBBER (NBR) 1 811-1 POWER CABLE — 1
†115-2 O-RING RUBBER (NBR) 1 811-2 CONTROL CABLE — 1
†115-3 O-RING RUBBER (NBR) 1 814 MOTOR COVER CAST IRON A48 Class 30 1
†115-4 O-RING RUBBER (NBR) 2 816 BRACKET CAST IRON A48 Class 30 1
†117 GASKET 1 817 BRACKET CAST IRON A48 Class 30 1
120-1 BOLT 304 STAINLESS AISI304 4 830 SHAFT 403 STAINLESS AISI403 1
120-2 BOLT 304 STAINLESS AISI304 8 838 WASHER 304 STAINLESS AISI304 2
120-3 BOLT 304 STAINLESS AISI304 4 †849-1 BALL BEARING — 1
120-4 BOLT 304 STAINLESS AISI304 4 †849-2 BALL BEARING — 1
120-5 BOLT 304 STAINLESS AISI304 3 876 MOTOR PROTECTOR — 3
120-6 BOLT 304 STAINLESS AISI304 4 909 LEAKAGE DETECTOR — 1
120-7 BOLT 304 STAINLESS AISI304 2 924 PACKING RUBBER (NBR) 2
125 BOLT 304 STAINLESS AISI304 1

Motors are purchased as a complete unit


†: Recommended spare parts

EBARA Fluid Handling


www.pumpsebara.com 2-210
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Sectional View
Project: Model: Chk’d: Date:
71/2 to 10HP

817 115
4
838 924 811
1 1 1
200 120 811 924
7 2 2
115 838
3 2
115
849 5
2
120
876 6

814 801

830 802
849 120
1 5
909
120
115 4
2
193 816
2
193 120
1 3

213 115
1
120
2

005

001

111

174 114

117 021
120
1 039

012 125

PART ASTM, AISI NO. FOR PART ASTM, AISI NO. FOR
NO. PART NAME MATERIAL CODE 1 UNIT NO. PART NAME MATERIAL CODE 1 UNIT
001 CASING CAST IRON A48 Class 30 1 174 DISCHARGE ELBOW CAST IRON A48 Class 30 1
005 INTERMEDIATE CASING CAST IRON A48 Class 30 1 193-1 PLUG 304 STAINLESS AISI304 1
†012 SUCTION COVER CAST IRON A48 Class 30 1 193-2 PLUG 304 STAINLESS AISI304 1
†021 IMPELLER CAST IRON A48 Class 30 1 200 LIFTING HANGER STEEL A283 Grade D 1
039 KEY 420 STAINLESS AISI420 1 213 AIR VENT VALVE BRASS B36 No. 272 1
†111 MECHANICAL SEAL — 1 SET 801 ROTOR — 1
†114 OIL SEAL RUBBER (NBR) 1 802 STATOR — 1
†115-1 O-RING RUBBER (NBR) 1 811-1 POWER CABLE — 1
†115-2 O-RING RUBBER (NBR) 1 811-2 CONTROL CABLE — 1
†115-3 O-RING RUBBER (NBR) 1 814 MOTOR COVER CAST IRON A48 Class 30 1
†115-4 O-RING RUBBER (NBR) 1 816 BRACKET CAST IRON A48 Class 30 1
†115-5 O-RING RUBBER (NBR) 1 817 BRACKET CAST IRON A48 Class 30 1
†117 GASKET 1 830 SHAFT 420J2 STAINLESS AISI420 1
120-1 BOLT 304 STAINLESS AISI304 4 838-1 WASHER 304 STAINLESS AISI304 1
120-2 BOLT 304 STAINLESS AISI304 8 838-2 WASHER 304 STAINLESS AISI304 1
120-3 BOLT 304 STAINLESS AISI304 4 †849-1 BALL BEARING — 1
120-4 BOLT 304 STAINLESS AISI304 6 †849-2 BALL BEARING — 1
120-5 BOLT 304 STAINLESS AISI304 3 876 MOTOR PROTECTOR — 3
120-6 BOLT 304 STAINLESS AISI304 4 909 LEAKAGE DETECTOR — 1
120-7 BOLT 304 STAINLESS AISI304 2 924-1 PACKING RUBBER (NBR) 1
125 BOLT 304 STAINLESS AISI304 1 924-2 PACKING RUBBER (NBR) 1

Motors are purchased as a complete unit


†: Recommended spare parts

EBARA Fluid Handling


www.pumpsebara.com 2-211
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Sectional View
Project: Model: Chk’d: Date:
15 to 30HP

817 115 838 924 811 200 120 811 924 838
5 1 1 1 8 2 2 2

115 115
4 6
849 120
2 7

876 830

814 801
909
802
115
3 849
1
120
4
120
193 6
2
120
115 5
1
816
213 2
115
2
816
1

005

120
174 2

193
117 1
120
1 120
3
012 001

125
039 021 114 111

PART ASTM, AISI NO. FOR PART ASTM, AISI NO. FOR
NO. PART NAME MATERIAL CODE 1 UNIT NO. PART NAME MATERIAL CODE 1 UNIT
001 CASING CAST IRON A48 Class 30 1 174 DISCHARGE ELBOW CAST IRON A48 Class 30 1
005 INTERMEDIATE CASING CAST IRON A48 Class 30 1 193-1 PLUG 304 STAINLESS AISI304 1
†012 SUCTION COVER CAST IRON A48 Class 30 1 193-2 PLUG 304 STAINLESS AISI304 1
†021 IMPELLER CAST IRON A48 Class 30 1 200 LIFTING HANGER STEEL A283 Grade D 1
039 KEY 420 STAINLESS AISI420 1 213 AIR VENT VALVE BRASS B36 No. 272 1
†111 MECHANICAL SEAL — 1 SET 801 ROTOR — 1
†114 OIL SEAL RUBBER (NBR) 1 802 STATOR — 1
†115-1 O-RING RUBBER (NBR) 1 811-1 POWER CABLE — 1
†115-2 O-RING RUBBER (NBR) 1 811-2 CONTROL CABLE — 1
†115-3 O-RING RUBBER (NBR) 1 814 MOTOR COVER CAST IRON A48 Class 30 1
†115-4 O-RING RUBBER (NBR) 1 816-1 BRACKET CAST IRON A48 Class 30 1
†115-5 O-RING RUBBER (NBR) 1 816-2 BRACKET CAST IRON A48 Class 30 1
†115-6 O-RING RUBBER (NBR) 1 817 BRACKET CAST IRON A48 Class 30 1
†117 GASKET 1 830 SHAFT 420J2 STAINLESS AISI420 1
120-1 BOLT 304 STAINLESS AISI304 4 838-1 WASHER 304 STAINLESS AISI304 1
120-2 BOLT 304 STAINLESS AISI304 8 838-2 WASHER 304 STAINLESS AISI304 1
120-3 BOLT 304 STAINLESS AISI304 4 †849-1 BALL BEARING — 1
120-4 BOLT 304 STAINLESS AISI304 6 †849-2 BALL BEARING — 1
120-5 BOLT 304 STAINLESS AISI304 6 876 MOTOR PROTECTOR — 3
120-6 BOLT 304 STAINLESS AISI304 3 909 LEAKAGE DETECTOR — 1
120-7 BOLT 304 STAINLESS AISI304 6 924-1 PACKING RUBBER (NBR) 1
120-8 BOLT 304 STAINLESS AISI304 2 924-2 PACKING RUBBER (NBR) 1
125 BOLT 304 STAINLESS AISI304 1

Motors are purchased as a complete unit


†: Recommended spare parts

EBARA Fluid Handling


www.pumpsebara.com 2-212
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Sectional View
Project: Model: Chk’d: Date:
40 to 60HP
100DLFU
120 811 924 838
838 924 811 200 8 2 2 2
1 1 1
115 115
6 7
115
817 5
849
120 2
7
801
876
802
814 120
6
830 115
4
849 120
1 4
120 816
2
5
816
115 1
3
193
1
909
120
193 3
2
115 111
2
115 005
1
114
213
120
2

001

021

039
174 080

117 125

167 107
120
1

PART ASTM, AISI NO. FOR PART ASTM, AISI NO. FOR
NO. PART NAME MATERIAL CODE 1 UNIT NO. PART NAME MATERIAL CODE 1 UNIT
001 CASING CAST IRON A48 Class 30 1 125 BOLT 304 STAINLESS AISI304 1
005 INTERMEDIATE CASING CAST IRON A48 Class 30 1 *167 BASE STEEL A283 Grade D 1
†021 IMPELLER CAST IRON A48 Class 30 1 174 DISCHARGE ELBOW CAST IRON A48 Class 30 1
039 KEY 420 STAINLESS AISI420 1 193-1 PLUG 304 STAINLESS AISI304 1
080 BUSHING 304 STAINLESS AISI 304 1 193-2 PLUG 304 STAINLESS AISI304 1
†107 WEARING RING 304 STAINLESS AISI 304 1 200 LIFTING HANGER STEEL A283 Grade D 1
†111 MECHANICAL SEAL — 1 SET 213 AIR VENT VALVE BRASS B36 No. 272 1
†114 OIL SEAL RUBBER (NBR) 1 801 ROTOR — 1
†115-1 O-RING RUBBER (NBR) 1 802 STATOR — 1
†115-2 O-RING RUBBER (NBR) 1 811-1 POWER CABLE — 2
†115-3 O-RING RUBBER (NBR) 1 811-2 CONTROL CABLE — 1
†115-4 O-RING RUBBER (NBR) 1 814 MOTOR COVER CAST IRON A48 Class 30 1
†115-5 O-RING RUBBER (NBR) 1 816-1 BRACKET CAST IRON A48 Class 30 1
†115-6 O-RING RUBBER (NBR) 2 816-2 BRACKET CAST IRON A48 Class 30 1
†115-7 O-RING RUBBER (NBR) 1 817 BRACKET CAST IRON A48 Class 30 1
†117 GASKET 1 830 SHAFT 420J2 STAINLESS AISI420 1
120-1 BOLT 304 STAINLESS AISI304 8 838-1 WASHER 304 STAINLESS AISI304 2
120-2 BOLT 304 STAINLESS AISI304 8 838-2 WASHER 304 STAINLESS AISI304 1
120-3 BOLT 304 STAINLESS AISI304 8 †849-1 BALL BEARING — 1 SET
120-4 BOLT 304 STAINLESS AISI304 8 †849-2 BALL BEARING — 1
120-5 BOLT 304 STAINLESS AISI304 6 876 MOTOR PROTECTOR — 3
120-6 BOLT 304 STAINLESS AISI304 4 909 LEAKAGE DETECTOR — 1
120-7 BOLT 304 STAINLESS AISI304 6 924-1 PACKING RUBBER (NBR) 2
120-8 BOLT 304 STAINLESS AISI304 2 924-2 PACKING RUBBER (NBR) 1
Motors are purchased as a complete unit
†: Recommended spare parts
*: Option for hard-piped installations

EBARA Fluid Handling


www.pumpsebara.com 2-213
(t) 803 327 5005 • (f) 803 327 5097 rev. 01/02
EBARA Submersible Sewage Pumps DLFU
Sectional View
Project: Model: Chk’d: Date:
40 to 60HP
150DLFU
200DLFU 817 115
6
838 924 811
1 1 1 200 120 811
9 2
924
2
838
2

250DLFU 849
2
115
7

300DLFU 115
120
8
5
801
876
802
814
120
7
830
849 111
1
120
115 6
4

115 816
3 2
193
909 2

120
120 4
5
816
1
120
3

005

001

114
174
021

280 072
193 120
1 2

117 039
115 120
1 1
115
2 107 167 125

PART ASTM, AISI NO. FOR PART ASTM, AISI NO. FOR
NO. PART NAME MATERIAL CODE 1 UNIT NO. PART NAME MATERIAL CODE 1 UNIT
001 CASING CAST IRON A48 Class 30 1 125 BOLT 304 STAINLESS AISI304 1
005 INTERMEDIATE CASING CAST IRON A48 Class 30 1 *167 BASE STEEL A283 Grade D 1
†021 IMPELLER DUCTILE IRON A536 60-40-18 1 174 DISCHARGE ELBOW CAST IRON A48 Class 30 1
039 KEY 420 STAINLESS AISI420 1 193-1 PLUG 304 STAINLESS AISI304 1
†072 SIDE RING CAST IRON A48 Class 30 1 193-2 PLUG 304 STAINLESS AISI304 1
†107 WEARING RING 304 STAINLESS AISI304 1 200 LIFTING HANGER STEEL A283 Grade D 1
†111 MECHANICAL SEAL — 1 SET 280 ELBOW SUPPORT STEEL A283 Grade D 2
†114 OIL SEAL RUBBER (NBR) 1 801 ROTOR — 1
†115-1 O-RING RUBBER (NBR) 1 802 STATOR — 1
†115-2 O-RING RUBBER (NBR) 1 811-1 POWER CABLE — 2
†115-3 O-RING RUBBER (NBR) 1 811-2 CONTROL CABLE — 1
†115-4 O-RING RUBBER (NBR) 1 814 MOTOR COVER CAST IRON A48 Class 30 1
†115-5 O-RING RUBBER (NBR) 1 816-1 BRACKET CAST IRON A48 Class 30 1
†115-6 O-RING RUBBER (NBR) 2 816-2 BRACKET CAST IRON A48 Class 30 1
†115-7 O-RING RUBBER (NBR) 1 817 BRACKET CAST IRON A48 Class 30 1
†117 GASKET 1 830 SHAFT 420J2 STAINLESS AISI420 1
120-1 BOLT 304 STAINLESS AISI304 3
/4 838-1 WASHER 304 STAINLESS AISI304 2
120-2 BOLT 304 STAINLESS AISI304 4 838-2 WASHER 304 STAINLESS AISI304 1
120-3 BOLT 304 STAINLESS AISI304 8 †849-1 BALL BEARING — 1 SET
120-4 BOLT 304 STAINLESS AISI304 4 †849-2 BALL BEARING — 1
120-5 BOLT 304 STAINLESS AISI304 8 876 MOTOR PROTECTOR — 3
120-6 BOLT 304 STAINLESS AISI304 8 909 LEAKAGE DETECTOR — 1
120-7 BOLT 304 STAINLESS AISI304 4 924-1 PACKING RUBBER (NBR) 2
120-8 BOLT 304 STAINLESS AISI304 6 924-2 PACKING RUBBER (NBR) 1
120-9 BOLT 304 STAINLESS AISI304 2
Motors are purchased as a complete unit
†: Recommended spare parts
*: Option for hard-piped installations

EBARA Fluid Handling


www.pumpsebara.com 2-214
(t) 803 327 5005 • (f) 803 327 5097 rev. 02/09