Cement

Compression Testers 94
Sample Preparation 95
Fineness 98
Setting Time 99
Flow 101
Soundness and Expansion 102

tel: 1-800-323-1242 fax: 1-970-663-9781 web: www.eleusa.com 93


Cement
COMPRESSION TESTERS

The compact single unit design offers a large surface area on the lower platen and
a 9" (229 mm) wide horizontal opening between the steel uprights. All hydraulic
pump operating controls are mounted on the front of the unit for easy access, and
the built-in overload protection provides machine and operator safety.
Supplied complete with standard platens, the ACCU-TEKTM 250 machines can test
6" x 12" (152 x 305 mm) cylinders, using either the capping compound or capping
pad methods. Included attachments make it easy to perform tests on 2” (50 mm)
cube samples.
The complete system meets ASTM C-109, C-39 and AASHTO T-22 specifications
covering the design and accuracy of hydraulic testing machines.

Specifications
Capacity. 250,000 lbf. (1,112 kN).
Frame. Upper and lower steel plate sections with four steel uprights,
threaded and welded into place; 14.75" w. x 12" d. x 37" h.
(375 x 305 x 940 mm).
Ram. 6-1/8" (155 mm) diameter; 3" (76 mm) travel.
Upper Platen. Swivel seat type; 6-1/4” (159 mm) diameter.
Lower Platen. 7" (178 mm) diameter.
Vertical Clearance. 12-1/2" (318 mm); or 14-1/2" (368 mm) with lower spacer
removed.
Horizontal Clearance. 9" (229 mm) between uprights.
Pump. 1 h.p. (0.7kw) electro-hydraulic pump mounted within reservoir
with overload protection.
Controls. Pump-mounted pressure compensated flow control valve with
4-position control lever and adjustable flow valve. Pump On/Off
switch.
Display. Digital display with membrane keypad; pace deviation bargraph;
automatic stress calculation; data storage for 500 tests; RS232C
data output and printer ports.
Range. 2,500 to 250,000 lbf. (11.2 to 1,112 kN).
Accuracy. Factory calibrated to within 0.5% of reading - from 1% to 100%
of machine capacity.
Overall Dimensions. 25.5" w. x 12" d. x 45" h. (648 x 305 x 1,143 mm).
Weight. Net 535 lbs. (243 kg).

Ordering Information
EI39-6100/02. 110vAC, 60 Hz, 1ø.
EI39-6100/06. 220vAC, 60 Hz, 1ø.
EI39-6100/01. 220vAC, 50 Hz, 1ø.
ACCU-TEK™ 250 Digital Series
ASTM C-109, C-39; AASHTO T-22. Compression Testing of 2” Cubes Test Set
ASTM C-109.
■ Selectable display in English or Metric units.
■ Automatic stress calculation and display. The Compression Testing of 2” Cubes Test Set is designed for testing 2” cement
■ Data storage and transfer capabilities for 500 tests. cubes.
■ RS-232C communication port for use on personal computers.
■ Adjusts for capping compound or capping pad method, by Ordering Information
removing the platen spacer. Set includes: 1 Accu-tek 250 Compression Machine (39-6100/0x)
2 Cement Cube Mold, 3-Unit (39-0412)
■ Includes platens for testing standard 2" (50.8 mm) cubes, 2 Cover Plate For Cement (39-0412/10)
frame stand, and download software with RS-232 cable. 1 Hard Rubber Tamper For (39-0420)
The lightweight, portable ACCU-TEK™ 250 Digital Series compression tester 1 Beaker, Glass 250Ml (88-6106)
offers economical, affordable quality testing on-site or in the lab. Each tester 1 Graduated Cylinder, 500ml (88-6010)
consists of a heavy duty 250,000 lbf. (1,112 kN) capacity load frame, hydraulic 1 Trowel (88-7410)
pump and digital readout system. EI3900/02. 110vAC, 60Hz, 1ø.
Using microprocessor technology, the digital readout system automatically displays EI3900/06. 220vAC, 60Hz, 1ø.
load and stress calculations.The easy-to-use membrane keyboard makes selection EI3900/01. 220vAC, 50Hz, 1ø.
of operating parameters simple and a pace deviation bar graph allows for fine
adjustment of the loading rate.The system features a large, backlit digital display for
easy viewing.

94 tel: 1-800-323-1242 fax: 1-970-663-9781 web: www.eleusa.com


Cement
S A M P L E P R E PA R AT I O N

Mortar Mixer, 5 Qt. (4.73 Liter)


ASTM C-305; AASHTO T-162.
■ 5 qt. (4.73 liter) capacity.
■ Three-speed selective transmission.
■ Stainless steel mixing bowl and beater for rust resistance and
easy cleaning.
■ Supplied complete with clearance adjustment bracket per
ASTM requirements.
This special 5 quart (4.73 liter) Mortar Mixer is used for mixing cement pastes
and mortars in accordance with ASTM and AASHTO specifications.The table
mounted unit has a planetary mixing action so that the stainless steel beater
reaches every part of the batch, rotating on its axis opposite to the direction in
which it moves around the bowl.This gives a thorough blending and mixing of all of
the ingredients, resulting in a consistent and predictable result in the finished mix.

Specifications
Capacity. 5 qts. (0.167 ft, 4.73 liters).
Motor. 1/6 h.p.; 124 Watts.
Speeds. Low, intermediate, and high; 139, 285 and 591 rpm.
Mixing. Planetary action.
Bowl. Stainless steel; with clearance adjustment bracket.
Beater. Flat-type; stainless steel.
Dimensions. 10-3/8" x 12-1/4" x 17" h. (263 x 311 x 432 mm).
Weight. Net 37 lbs. (16.8 kg); Shpg. 55 lbs. (25 kg).

Ordering Information
EI39-0075/02. 115vAC, 60 Hz, 1ø.
EI39-0075/06. 220vAC, 60 Hz, 1ø.
EI39-0075/01. 220vAC, 50 Hz, 1ø.

Replacement Parts
EI39-0075/10. Stainless Steel Bowl.
EI39-0075/12. Stainless Steel Beater.

tel: 1-800-323-1242 fax: 1-970-663-9781 web: www.eleusa.com 95


Cement
S A M P L E P R E PA R AT I O N

Cement Cube Mold (ASTM)


ASTM C-87, C-109, C-141, C-579, C-593; AASHTO T-106. 2" (50.8 mm) Cube Test System
■ Manufactured in strict conformance to ASTM and AASHTO ■ Complete, low cost system for making and testing 2"
specifications. (50.8 mm) cubes.
■ Three-gang design for multiple sample preparation. ■ Durable brass mold frame.
■ Wide flange design for mold stability and performance. ■ Removable polypropylene water tight disposable liners.
■ Precision machined forged bronze construction for accuracy ■ No cleaning of mold required, just insert new liner.
and corrosion resistance. ■ New “unbonded” capping system required when using this
method; capping accessories included in every kit.
Designed and manufactured in strict conformance to ASTM standards, the Cement ■ Reproducible, accurate results.
Cube Mold is used to form 2" (50.8 mm) cube samples for compressive strength
testing of Portland cement, mortars, lime, gypsum and capping compounds. The 2” (50mm) Cube Test System consists of a brass three gang mold with liners
for specimen preparation and a new unbonded capping system for use during
The main feature in the design is the wide flange construction of the top and base. compression testing.
This wide flange simplifies the striking off of excess amounts of cement when the
cubes are being prepared and gives greater stability to the mold in storage, In operation the plastic liners are placed into the mold cavities. A layer of cement
preparation and curing.The sturdy flanges prevent warping of the mold during use. (about 1") is placed into all compartments and tamped.The compartments are
Warping has been the cause of cement cube molds losing their dimensions and then filled to overflowing, tamped, and then smoothed flush to the top of the
angular tolerances. mold. After curing, the samples are easily removed by pulling the liner tabs up and
out of the cavity.The specimens are then stripped by cutting the plastic liner with a
Another important feature is the use of mechanical screw clamps to connect the utility knife.
two halves of the mold so they can be drawn tightly together.This same feature is
important in removing cubes from the mold.With an unscrewing action on the Compression testing of the specimens is performed using the provided capping
clamps, the two sides of the mold can be drawn apart uniformly.This eliminates system.Testing without the use of the cap system will result in erroneous low
prying the mold sections apart with a trowel, knife or other sharp instrument, a compressive strengths.
practice which destroys mold surfaces and springs the mold out of tolerance.The
“T” bolts are held in place by snap rings which precludes loss and allows for ready Specifications
replacement should the “T” bolt be damaged.To facilitate cleaning of the mold, all Mold Frame. Brass; three gang.
of its surfaces are clean lined and smooth. Liners. Water tight polypropylene with tabs.
Tamping Rod. Polypropylene.
Specifications Retainer Caps. Stainless steel.
Sample Size. Up to three 2" (50.8 mm) cubes. Compression Pads. Polyurethane; 1/4" (6.3 mm) thick.
Construction. Forged bronze; three-gang with wide-flanged top and base; Weight. Net 7 lbs. (3.2 kg).
machined and ground finish.
Mold Closure. Mechanical; “T” bolt screw clamps held in place by snap rings.
Base Plate. Machined forged bronze with knurled hold-down screws. Ordering Information
EI39-0414. Includes stainless steel three gang mold, 27 liners, tamping rod,
Weight. Net 12 lbs. (5.4 kg).
2 retainer caps, 4 compression pads and utility knife.

Ordering Information Replacement Parts


EI39-0412. EI39-0414/10. Plastic Disposable Liners. Box of 198.
EI39-0414/12. Compression Pads. Set of 4.
Accessories
EI39-0412/10. Cover Plate. Acts as riser to slow rate of cooling of cube center. Special Note:
EI39-0420. Hard Rubber Tamper. 1/2" x 1" x 6" l. (12.7 x 25.4 x 152.4 mm). Testing without the use of the “unbonded” cap system will result in erroneous low
compressive strengths.

96 tel: 1-800-323-1242 fax: 1-970-663-9781 web: www.eleusa.com


Cement
S A M P L E P R E PA R AT I O N

Cement Mold Brush


■ Brass bristles prevent damage to molds.
■ Tapered wooden handle.
The Cement Mold Brush is ideally suited for cleaning cement from molds, slump
cones and other devices after use.

Specifications
Handle. Wooden.
Bristles. Stiff brass wire; 5/8" w. x 5" l. (15.8 x 127 mm).
Overall Length. 10" (254 mm).
Weight. Net 8 oz. (227 g).

Ordering Information
EI39-0425.

Test Sand (#20-30)


ASTM C-91, C-185, C-359, C-778; AASHTO T-132.
■ Standardizes mortar for tensile strength testing.
■ Specially graded to meet industry standards.
■ Supplied in 50 lb. (22.6 kg) heavy-duty bags.
Supplied in 50 lb. (22.6 kg) bags, this Sand is specially graded to pass a No. 20 sieve
Cement Cube Mold (Economy) and be retained on a No. 30 sieve within the tolerances specified by ASTM and
AASHTO standards.
■ Economical three-gang design.
■ Manufactured from corrosion-resistant materials. Specifications
■ Includes top and compaction tamper. Specific Gravity. 2.65.
The Economy Cube Mold is designed to form 2" (50.8 mm) cube samples Bulk Density. 97.14 PCF (1.556 gm/cc).
for compressive strength testing.The three-gang mold is manufactured out of Grading. Passes No. 20 sieve; retained on No. 30 sieve.
ultra-high density molecular weight polyethylene.The mold is supplied complete Weight. Net 50 lbs. (22.6 kg).
with a top and compaction tamper.
Ordering Information
Specifications EI39-0430.
Construction. Ultra-high density molecular weight polyethylene; three gang;
up to three 2" (50.8 mm) samples.
Top. Polyethylene with plastic guide rails. Cube Test Sand
Tamper. Polyethylene. ASTM C-109, C-349, C-359, C-379, C-778; AASHTO T-106.
Weight. Net 2 lbs. (0.9 kg).
■ Specially graded to meet industry standards.
Ordering Information ■ Supplied in 50 lb. (22.6 kg) heavy-duty bags.
EI39-0416. This specially graded Sand is used in the preparation of mortar for strength
testing.
Hard Rubber Tamper
ASTM C-109, C-157, C-185, C-227, C-243; Specifications
AASHTO T-71, T-106, T-137. Specific Gravity. 2.65.
Bulk Density. 93.45 PCF (1.497 gm/cc).
■ Meets ASTM and AASHTO specifications. Grading. No. 16 sieve retains 0%. No. 30 sieve retains 2%.
■ Hard rubber design prevents damage to mold during No. 40 sieve retains 30%. No. 50 sieve retains 75%.
No. 100 sieve retains 98%.
compaction.
Weight. Net 50 lbs. (22.6 kg).
The Hard Rubber Tamper is used for preparing mortar specimens for compressive
strength testing.The tamper’s cross section is approximately one half inch by one
Ordering Information
inch and is six inches long.
EI39-0435.
Specifications
Construction. Hard rubber.
Dimensions. 1/2" x 1" x 6" (12.7 x 25.4 x 152 mm) l.
Weight. Net 4 oz. (113 g).

Ordering Information
EI39-0420.

tel: 1-800-323-1242 fax: 1-970-663-9781 web: www.eleusa.com 97


Cement
FINENESS

Blaine Fineness Apparatus Le Chatelier Flask


ASTM C-204; AASHTO T-153. ASTM C-128; C-188, E-694; AASHTO T-133.
The Blaine Fineness Apparatus is used in measuring the fineness of Portland ■ High quality, chemical-resistant glass construction.
cement in accordance with ASTM and AASHTO standards.The fineness is ■ Graduation markings in accordance with industry standards.
measured in terms of the specific area of cement expressed as total surface area
in square centimeters per gram. The Le Chatelier Specific Gravity Flask is used for determining the apparent
specific gravity of sand, stone, hydraulic cement and slag screenings.
In operation, the apparatus draws a definite volume of air through a prepared bed
of cement.The porosity of the cement, which is a function of the size of the Designed in accordance with industry standards, the flask is supplied complete
cement particles, determines the rate of air flow through the bed. with a glass stopper.
The apparatus consists of a U-tube glass manometer, a ground joint with stainless Specifications
steel test cell, a stop cock, and a rubber bulb.
Graduations. Zero mark represents 250 ml, the capacity of the large bulb;
neck graduations from 0-1 ml in 0.1 ml divisions with two extra
Specifications 0.1 ml graduations above the 1.0 and below the 0 marks;
Cell. Stainless steel; 12.70 ±0.10 mm i.d. bulb portion of neck holds 17 ml; top portion of neck graduated
Disk. 0.9 ±0.1 mm thick with 30-40 one mm diam. holes. from 18-24 ml in 0.1 ml divisions; 24 ml capacity.
Plunger. Stainless steel. Stopper. Ground glass.
Manometer. U-tube glass with ground joint, stop cock and rubber bulb Weight. Net 8 oz. (227 g).
assembly.
Filter Paper. 12.70 mm diam. Ordering Information
Fluid. Dibutylphthalate. EI38-1200.
Weight. Net 6 lbs. (2.8 kg).

Ordering Information
EI38-1000.

Accessories
EI38-0640. Standard Reference Material No. 114P. Glass Vial. For calibration
of EI38-1000.

Replacement Parts
EI38-0652. Filter Paper. 12.70 mm diam. Box of 500.
EI38-1000/10. Manometer U-Tube.
EI38-1000/15. Blaine Air Permeability Cell. Stainless Steel with Disc and Plunger.
EI38-0620. Manometer Liquid (Dibutylphthalate).

98 tel: 1-800-323-1242 fax: 1-970-663-9781 web: www.eleusa.com


Cement
SETTING TIME

Cement Setting Time Test Set


ASTM C-91, C-187, C-191; AASHTO T-129, T-131.
The Cement Setting Time Test Set is a basic set for testing the setting time of
cement test specimens.

Ordering Information
Set includes: 1 Vicat Apparatus, Complete (38-2012).
1 Harvard Trip Balance (78-7090).
1 2100 g.Weight Set (78-7110).
1 Scoop and Counter Weight (78-7130).
EI3806

Vicat Apparatus
ASTM C-91, C-187, C-191; AASHTO T-129, T-131.
■ Rigid frame construction for accurate readings.
■ Reversible plunger with removable needle.
■ Includes needle and hard rubber mold.
The Vicat Apparatus is designed for determining the normal consistency, standard
consistency and time of setting of cement and lime in accordance with ASTM and
AASHTO specifications.
The apparatus consists of a frame bearing a movable plunger of 300 grams weight.
The Plunger is 10 mm diameter at one end and is fitted with a removable 1 mm
diameter needle at the other end.The plunger is reversible and carries an indicator
which moves over the scale graduated in millimeters.
The apparatus is supplied complete with plunger, needle and hard rubber mold.

Specifications
Plunger. Reversible; 10 mm diam. at one end and 1 mm diam. needle at
other end; combined weight 300 grams.
Needle. Steel; mounted in plunger; 1 mm diam. x 50 mm long.
Scale. Graduated in millimeters.
Mold. Hard rubber; 70 mm base diam. x 60 mm top diam. x 40 mm h.
Weight. Net 4 lbs. (1.8 kg).

Ordering Information
EI38-2012. Includes Vicat needle and mold.

Replacement Parts
EI38-2620. ASTM Vicat Needle.
EI38-2660. ASTM Vicat Mold and Glass Plate.
®

tel: 1-800-323-1242 fax: 1-970-663-9781 web: www.eleusa.com 99


Cement
SETTING TIME

Mortar Penetrometer
ASTM C-403.
Acme Laboratory Penetrometer ■ 130 lb. capacity with 1 lb. subdivisions.
ASTM C-403; AASHTO T-197. ■ Includes 6 interchangeable needles as specified in ASTM
testing standards.
■ Hydraulically operated with 200 lbf. (890 N) capacity gauge. ■ Plated for rust resistance and long life.
■ Can be used in either the laboratory or field. ■ Convenient carrying case with individual compartments.
■ Includes six stainless steel proctor needles. The Mortar Penetrometer set is used for determining the rate of hardening of
The ASTM penetrometer resistance test of concrete is a procedure used to mortars sieved from concrete mixtures.The unit consists of a specially calibrated
measure the rate of hardening of mortars sieved from concrete mixtures.The test spring dynamometer with a pressure-indicating scale on the stem of the handle.
is used to determine the effects of variables such as temperature, cement, mix The pressure scale is calibrated to 130 lbs. by 1 lb. subdivisions.There is a major
design, additions and ad-mixtures upon hardening characteristics of concrete. division located at each 10 lb. interval. A sliding ring on the stem indicates the
maximum load obtained during the test.
The Acme Laboratory Penetrometer is designed for highly accurate laboratory
or field studies.This hydraulically operated apparatus is designed to develop
uniformity in complete time-rate-penetration resistance studies of concrete
Specifications
mortar.The unit is supplied complete with six penetration needles. Penetrometer. Calibrated spring dynamometer.
Pressure Scale. 130 lbs. x 10 lb. and 1 lb. subdivisions.
Specifications Test Reading. Indicated by sliding ring.
Capacity. 200 lbf. (890 N). Needles. Includes: 1, 1/2, 1/4, 1/10, 1/20 and 1/40 sq. in. end area needles.
Operation. Hydraulic. Carrying Case. Plastic with shelf; 18" w. x 6" d. x 4-3/4" h.
(457 x 152 x 121 mm).
Needles. 6 included; 1/40, 1/20, 1/10, 1/4, 1/2 and 1 sq. in. end areas;
stored in wooden block holder. Weight. Net 7 lbs. (3.2 kg).
Weight. Shpg. 60 lbs. (27 kg).
Ordering Information
Ordering Information EI38-2675. Includes penetrometer, six needles and carrying case.
EI38-2670. Includes one package of data sheets.

100 tel: 1-800-323-1242 fax: 1-970-663-9781 web: www.eleusa.com


Cement
SETTING TIME AND FLOW

Gillmore Apparatus
ASTM C-91, C-141, C-266, C-414; AASHTO T-154.
■ Lightweight aluminum alloy horizontal arm supports.
■ Stainless steel needles for corrosion resistance and long life.
The Gillmore Apparatus is used to determine the time of set of cement.The
apparatus consists of one needle point of each size, base, support shaft and
horizontal arm.
10" (254 mm) Flow Table
Specifications ASTM C-87, C-109, C-185, C-230, C-243, C-348;
Needles. Machined steel with stainless steel points.
Small needle: 1/4 lb. (113.4 g); 1/12" (2.12 mm) diam. point.
AASHTO T-71, T-106, T-137.
Large needle: 1 lb. (453.6 g); 1/24" (1.06 mm) diam. point.
Weight. Net 8 lbs. (3.6 kg).
■ Cast-bronze table for corrosion resistance and long life.
■ Heavy-duty frame construction.
■ Supplied complete with bronze flow mold.
Ordering Information
EI38-2690. The Flow Table is designed in accordance with ASTM and AASHTO specifications
for use in determining the flow of hydraulic cement mortars and cement pastes.
Accessories In operation, the test specimen is molded on the table to a specified volume and
EI38-2690/10. Gillmore Test Sample Template. shape.With the mold removed, the table is dropped a specified number of times.
Upon completion of test, the flow, or increase in average diameter, is measured.

Concrete Mortar Penetrometer Specifications


Table. Cast-bronze; 10" (254 mm) diam.; combined weight with shaft,
■ Direct-reading scale from 0 to 700 psi. 9 lbs. ±0.1 lb. (4.1 ±0.05 kg).
■ Indicator sleeve holds reading until released. Frame. Heavy-duty construction with cam; produces a 1/2" (12.7 mm)
■ Lightweight, pocket-size design. table drop.
■ Includes convenient belt-loop style, canvas carrying case. Overall Dimensions. 10" (254 mm) diam. x approx. 10" (254 mm) h.
Flow Mold. Machined bronze; 2-3/4" (69.8 mm) top i.d. x 4" (101.6 mm)
The Concrete Mortar Penetrometer is used for field and laboratory evaluations of
base i.d. x 2" (50.8 mm) h.
the initial set of concrete mortars.
Weights. Net 22 lbs. (10 kg).
The test involves forcing the penetrometer’s shaft into the mortar to a depth of 1"
(25.4 mm) at constant rate and time intervals.The resistance in psi is shown on
Ordering Information
the penetrometer’s direct-reading scale.
Note: Includes Flow Mold.
Specifications EI38-6002. Hand-operated.
Shaft Needle. Steel; 1/20 sq. in. surface area.
Range. 0 to 700 psi. Accessories
Scale. Direct-reading; indicator sleeve holds reading until released. EI38-6080. Flow Caliper.
Dimensions. 3/4" (19 mm) diam. x 7" (178 mm) long.
Carrying Case. Canvas, with belt-loop. Replacement Parts
Weight. Net 8 oz. (227 g). EI38-6040. Flow Mold.

Ordering Information
EI38-2695.

tel: 1-800-323-1242 fax: 1-970-663-9781 web: www.eleusa.com 101


Cement
S O U N D N E S S A N D E X PA N S I O N

Test Bar Molds


ASTM C-141, C-151, C-157, C-227, C-490, C-531; AASHTO T-107.
■ Forms 10" (254 mm) gauge length specimens.
■ Available in a variety of types and sizes.
■ Plated for rust resistance and long life.
Test Bar Molds are designed to form specimens in accordance with ASTM and
AASHTO specifications, for use in the Cement Autoclave.

Specifications
Construction. Plated steel.
Gauge Length. 10" (254 mm) between inner ends of embedded contact points.
Weights. EI34-8544: Net 20 lbs. (9.1 kg).
EI34-8545: Net 22 lbs. (10 kg).

Ordering Information
EI34-8544. Two-Gang Mold. 1" x 1" x 10" (25.4 x 25.4 x 254 mm) gauge
length.
EI34-8545. Single Mold. 4" x 4" x 10" (101.6 x 101.6 x 254 mm) gauge
length.

Accessories
EI34-8548. Contact Points-1/4"(6.3mm) diam. x 3/4" (19mm) long. Length Comparator
Pack of 100. ASTM C-151, C-157, C-227, C-490, C-531; AASHTO T-107, T-
160.
■ Double-post frame construction for stability.
■ Sturdy metal base platform.
■ Precision machined Invar steel reference bar.
■ Available in either English or Metric models.
The Length Comparator is a device used for measuring the length changes of
cement paste, mortar and concrete specimens, in accordance with ASTM and
AASHTO specifications.
The precision unit consists of a sensitive dial indicator mounted on a sturdy, dual
post construction frame.The movable and stationary anvils are shaped to receive
the reference pins which are cast into the ends of the test specimen bars.
The Length Comparator is supplied complete with an Invar steel reference bar.

Specifications
Frame. Metal, double-post construction; rust resistant finish.
Anvils. One movable and one stationary; shaped to receive contact
points in sample bars.
Dial Indicator. English: 0.3000" x 0.0001" divisions (EI34-8504).
Metric: 8.000 mm x 0.002 mm divisions (EI34-8505).
Digital: English or Metric
Reference Bar. Invar metal.
Dimensions. 7-1/2" w. x 7-3/4" d. x 17-3/4" h. (190 x 197 x 451 mm).
Weight. Net 13-1/2 lbs. (6.1 kg).

Ordering Information
Note: Digital model shown.
EI34-8504. English.
EI34-8505. Metric.

102 tel: 1-800-323-1242 fax: 1-970-663-9781 web: www.eleusa.com