Energy meters
CeweMeters constitute a range of electronic energy meters for mounting
on DIN rail. The meters are type approved according to IEC 1036.
CeweMeters are equipped with LCD display, with big plain figures and
symbols, which make them easy to read. The meters are also equipped
with an electronic installation check that shows whether the connection is
correct or not.
The transformer connected meters are equipped with one sealable push
button for programming.
Technical information
Technical data:
Meter: LED frequency
Accuracy class Class 1 or 2 - Transformer connected 10.000 imp/kWh
(IEC 1036), - Direct connected 1.000 imp/kWh
Display LCD with 8 figu-
Voltage ± 15% of nomi-
res, 7 mm high
nal voltage
CT ratio Progammable
Impulse voltage 6 kV
Case
Nominal frequency 50 or 60 Hz
- Width 125 mm
Transformer connected - Height 96 mm
- Current Class l: 1and 5 A - Depth 66 mm
- Start Current <2 mA - Material Polycarbonate
Direct connected Weight Approx. 0,5 kg
- Current Class 2: 5 (65) A
- Start Current <25 mA Pulse output:
Power consumption Type Solid state opto
- Current circuit <1.0 VA/phase isolated
- Voltage curcuit <1.5 VA/phase Pulse frequency See product range
Temperature range Pulse length 60 ms
- Operating -20 to +55 °C Max wire size 2.5 mm 2
- Storage -25 to+70 °C Standard use
- S0-1 pulse output EN 62053-31
Protection class II
(class A and B)
Degree of protection Optional use
- Meter IP51 - Potential-free output
- Connection terminal IP 20 - Max voltage 230 V AC/DC
Max wire size - Max current 100 mA
- Transformer connected 10 mm2
- Direct connected 25 mm2
Accessories
Art. No. Description Remark
5020 Long cover Wall mounting
5021 Panel mounting kit
Meter label
Certification Frequency
marks CM 34 01 24 3 x 230/400 V
50/60 Hz Nominal (max)
EAN code 5(65) A cl. 2 current
1000 imp/kWh
Accuracy class
LED 10000 imp/kWh
Manufacture www.ceweinstrument.se
B0491
SWEDEN 2000 00502000 Pulse output
frequency
LED frequency
Protective class II Serial number (Meter constant)
Production year
Wiring diagram
Direct connected CT connected
1 3 4 6 7 9 11 1 2 3 4 5 6 7 8 9 11
L1
L2 S1 S2 S1 S2
S1 S2
L3 L1
B0399
N L2
4-wire meter L3
B0401
N
4-wire meter
1 3 4 6 7 9
L1 1 2 3 5 7 8 9
L2
B0400
L3
3-wire meter S1 S2 S1 S2
L1
L2 3-wire meter
B0402
L3
(3 x 230 V)
1 2 3 4 5 6 7 8 9
S1 S2 S1 S2
L1
L2 3-wire meter
B0403
L3
(3 x 400 V)
www.ceweinstrument.se
Dimensions
LED
98,5
Scroll
119
B0424A
50
125 66 125 50
80 mm
+ 0,5 + 0,5
Cut-out 148 – 0 x 50 – 0
B0437
160
mm
Presentation
Processes Network drawings statistics Invoice base
Communication
Processing
Measuring
Different forms of controlling may be done locally or from the central system.
Cewe Instrument AB
Box 1006 • SE-611 29 Nyköping • SWEDEN
Tel: +46 155 775 00 • Fax: +46 155 775 97
e-mail: info@ceweinstrument.se • www.ceweinstrument.se
A0090e-5