You are on page 1of 16

इंटरनेट मानक

Disclosure to Promote the Right To Information


Whereas the Parliament of India has set out to provide a practical regime of right to
information for citizens to secure access to information under the control of public authorities,
in order to promote transparency and accountability in the working of every public authority,
and whereas the attached publication of the Bureau of Indian Standards is of particular interest
to the public, particularly disadvantaged communities and those engaged in the pursuit of
education and knowledge, the attached public safety standard is made available to promote the
timely dissemination of this information in an accurate manner to the public.

“जान1 का अ+धकार, जी1 का अ+धकार” “प0रा1 को छोड न' 5 तरफ”


Mazdoor Kisan Shakti Sangathan Jawaharlal Nehru
“The Right to Information, The Right to Live” “Step Out From the Old to the New”

IS 12330 (1988): Specificatioon for sulphate resisting


Portland cement [CED 2: Cement and Concrete]

“!ान $ एक न' भारत का +नम-ण”


Satyanarayan Gangaram Pitroda
“Invent a New India Using Knowledge”

“!ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता ह”


है”

Bhartṛhari—Nītiśatakam
“Knowledge is such a treasure which cannot be stolen”
IS : 12330 - 1988
( Reaffirmed 2009)

Indian Standard
SPECIFICATION FOR
SULPHATE RESISTING PORTLAND CEMENT
( Fourth Reprint MAY2000 )

UDC 666.942.35

© Copyright 1988
BUREAU OF INDIAN STANDARDS
MANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG
NEW DELHI 110002
Gr 3 August 1988
II a 12330· 1988

Indian Standard
SPECIFICATION FOR

AMENDMEN1' NO. 1 AUGUST 1991


TO

IS 12330: 1988 SPECIFICATION FOR


SULPHATE RESISTING PORTLAND CEMENT
( Page 3, clause 8.1 ) - Insert the following new clauses after 8.2
, and renumber the existing clause 8.3 as 8.4:

'8.3 When cement is intended for export and if the purchaser so requires,
packing of cement may be done in bags other than those given in 8.2 with
an average net mass of cement per bag as agreed to between the purchaser
and the manufacturer.

8.3.1 For this purpose the permission of the certifying authority shall
be obtained in advance for each export order.

8.3.1 The words 'FOR EXPORT' and the average net mass of cement
per bag shall be clearly marked in indelible ink on each bag.

8.3.3 The packing material shall be as agreed to between the supplier


and the purchaser.

8.3.4 The tolerance requirements for the mass of cement packed in bags
shall be al given in Appendix A except the average net mass which shall
be equal to or more than the quantity in 8.3. t

Printed at Dee Kay Printers, New Delhi-llOOlS, India


Indian Standard
SPECIFICATION FOR

AMENDMENT NO.2 NOVEMBER 1991


TO
IS 12330: 1988 SPECIFICATION FOR SULPHATE
RESISTING PORTlAND CEMENT
(Page S, clause A.l.2) - Substitute 'up to 25 tonnes' for 'of 20 to 25
tonnes'.

(CED2)

Printed at Dee Kay Printers, New Delhi-llOO1S, India.


Indian Standard
SPECIFICATION FOR

AMENDMENT NO.3 JUNE 1993


TO
IS 12330 : 1988 SPECIFICATION FOR SULPHATE
RESISTING PORTLAND CEMENT
[ Page 3, clause 8.1 ( see also Amendment No.1») - Substitute the
following for the existing clauses 8.3 to 8.3.4:
u8.3 When cement is intended for export and if tbe purchaser so requires,
packing of cement may be done in bags or in drums with an average net mass of
cement per bag or drool as agreed to between the purchaser and the
manufacturer.
8.3.1 For tbis purpose the permission oftbe certifying authority shan be obtained
in advance for each export order.
8.3.Z The words 'FOR EXPORT' and tbe average net mass of cement per
bag/drum shall be clearly marked in indelible ink on each bag/drum.
8.3.3 The packing material shall be as agreed to between the manufacturer and
the purchaser.
8.3.4 The tolerance requirements for the mass of cement packed in bags/drum
shall be as given in 8.1 except the average net mass which shall be equal to or
more than the quantity in 8.3."

(CED2)
Printedat Dee Kay Printers, New Delhi-llOOlS, India.
AMENDMENT NO. 4 APRIL 2000
TO
IS 12330: 1988 SPECIFICATION FOR SULPHATE
RESISTING PORTLAND CEMENT
Substitute 'net miss' lor 'average net . .sa' wherever it appeall in tbe
staDdard.

(CED2)
Printed at Dee Kay Printers, New Delhi
AMENDMENT NO. 5 MA Y 2004
TO
IS 12330: 1988 SPECIFICATION FOR SULPHATE
RESISTING PORTLAND CEMENT
( Page 2, clause 5.3.1, line 6) - Substitute 'less than' for 'not less than'.

«('ED2 )

Reprography Unit, BIS, New Delhi, India


AMENDMENT NO.6 JUNE 2006
TO
IS 11330 : 1988 SPECIFICATION FOR SULPHATE
RESISTING PORTLAND CEMENT
( First coverpage ) - Insert the following above the English title of the
Indian Standard:

(CED2)

Reproppby Unit,BIS, New Delhi, IDdia


18 I 12330 • 1988

Indian Standard
SPECIFICATION FOR
SULPHATE RESISTING PORTLAND CEMENT

o. FOR E WORD
0.1 This Indian Standard was adopted by the the concrete is exposed to the risk of deteriora-
Bureau of Indian Standards on 12 May 1988, tion due to sulphate attack, for example, in cont-
after the draft finalized by the Cement and act with soils and ground waters containing
Concrete Sectional Committee had been approved excessive amounts of sulphates as well as for
by the Civil Engineering Division Council. concrete in sea water or exposed directly to sea
coast.
0.2 Sulphate resisting Portland cement is a type
of Portland cement in which the amount of 0.3 Mass of cement packed in bags and the
tricalcium aluminate is restricted to an acceptably tolerance requirements for the mass of cement
low value." This cement should not be mistaken packed in bags shall be in accordance with the
for supersulphated cement, which is produced by relevant provisions of the Standards of Weights
intcrgrinding or intimately blending a mixture of and Measures ( Packaged Commodities) Rules,
"granulated blast furnace slag, calcium sulphate 1977 and A-l.~ (see Appendix A for informa-
and a small amount of Portland cement or Port- tion). Any modification to these Rules in respect
land cement clinker or any other source of lime. of rolei ance on mass of cement would automati-
Sulphate resisting Portland cement can be cally apply to this standard.
used for structural concrete wherever ordinary
Portland cement or Portland pozzolana cement 0.4 For the purpose of deciding whether a
or Portland slag cement are useable under normal particular requirement of this standard is compli-
conditions. Use of supersulphated cement is, ed with, the final value, observed or calculated,
however, generally restricted where the prevailing expressing the result of a test, shall be rounded
temperature is below 40°C. The later is not off in accordance with IS : 2-1960·. The number
recommended for producing steam-cured of significant places retained in the rounded off
products. value should be the same as that of the specified
value in this standard.
0.2.1 Use of sulphate resisting Portland cement
is particularly beneficial in such conditions where ·Rules for rounding off numerical values ( "l'is,d ,.

1. SCOPE water or both, and not more than one percent of


air-entraining agents or other agents which have
1.1 This standard covers the manufacture, proved not to be l.armful.
chemical and physical requirements and testing
NO'I'J': - Chemic ..d gypsum may be adued provided
of sui phate I csisting Portland cement, that the. performance J equirernents of the final product
as specified in this standard an' met with.
2.' TERMINOLOGY
4. CHEMICAL REQUIREMENTS
2.1 For the purpose of this standard, the
definitions given in IS : 4845-1968· shall apply. 4.1 \'Vhen tested in accordance with the methods
given in IS : 4032-1985*, sulphate resisting Port-
3. MANUFACTURE land cement shall comply with the che mical
requirements given in Table J.
3.1 Sulphate resisting Portland cement shall be
manufactured by grinding and intimately mixing 5. PHYSICAL REQ,UIREMENTS
together calcareous and argillaceous and/or other
silica, alumina and iron oxide bearing materials, 5.1 Finenes. - When tested for fineness by
burning them at clinkering temperature and Blaine's air permeability method as given in
grinding the resultant clinker so asto produce a IS : 4031 (Part 2 )-1988t, the specific surface
cement capable of complying with this specifica- of cement shall be not less than 225 n1 2/kg.
tion. No material shall be added after burning ·Methods of chemical analysi, for hydraulic cement
other than gypsum (natural 01" chernical ] or ( fi,st "V;S;OIl ).
tMethods 'of physical tests for hydraulic cement: Part 2
• Definitions and ternrinology relating to hydraulic Derermlnarion of fineness by specific surface b)' Blaine air
cement. perrneabilit y method ( fi,st ,'V;S'OIl ).
IS I 12330 • 1.81

TABLE 1 CHEMICAL .ZQUlRBM8NT8I'OR SULPHATB aBUSTING PORTLAND CEMENT


( CltluJ' 4.1 )

SL No. CHARACTERISTIC RJ:QU1RII:JlEIC~

i) aatio of percentage or lime to percent.,es or silica, alumina and iron Not ,reater tban 1·02 and not leu
oxide; when calculated by the formula: thaD 0-66
CaD - 0'7 SO,
z-e 5,0, + 1'2 AI,O, + O·6~ F••O.
ii) Insoluble residue, percent by mass Not more than ...
iii) Malneli., percent by mass Not more tban 6
iv) Total sulphur content calculated as sulphuric anhydride (SO.), per- Not more than 2·5
cent by mass
v) TricaJcium aluminate ( C,A ). percent by mass ( SI' Note 1 ) Not more than 5
vi) Tetr.calcium alumino ferrite phase plus twice the tricalcium Not more than 25
aluminate ( C.AF + 2C.A ), percent by mass ( st' Note 1 )
vii) Total loS! on ignition, percent by malS Not more than 5
NOTE I - The tricalcium aluminate and tetracalcium alumino ferrite content are calculated by the following
formulae:
CaA = 2-65 AI.O. - 1-69 F••O,
C~AF = 3-04! Fe,O,
When the alumina - ferrle oxide ratio is less than 0·64 (hence CaA i. abient). a calcium alumino ferrite solid
solution expres.ced as SS (C.AF +
e.F) il formed. Contents of this solid solution and oC tricalcium lillcate shall
be calculated by the following formulae:
SS ( C.AF + e.F) == ( 2·100 AI.O a ) + ( 1'702 Fe,Oa )
C.~ = (4'071 CaD ) - ( "600 SiO. ) -
( '-479 AI.O:. ) - ( 2'859 Fe,O, ) - (2-852 SO. )
NOT. 2 - When expreSliol compounds, certain symbols have been used, namely, C t:::I CaO s :)~ a::a SiO•• ~ =-
AI.O., and F - Fe.O.. For example, C,A 'CaO.AI.O.. Titanium dioxide and phosphorous pentoxide
::::!

( TiO, and p.O I ) shall be included with the AI,O, content. The value historically and traditioaa1Jy used for AI.O.
in calt'u)atinl pot.ntial compoundl for sp~ification purpose. is the ammonium hydroxide ,roup minus ferric oxide
( R.J.Oa - F•• O.) as obtained by clalsical wet chemical methods. This procedure includes as AI.O. the TiO••
p.u. and other trace oxides which precipitate with the ammonium hydroxlde group in the classical wet chemical
methods. Many modern instrumental methods of cement analysis determine aluminium or aluminium oxide
directly without the minor and trace oxides included as in the claairal method. CORStqufntly, for consistency and
to provide comparability with historic data and among varioul analytical methods, when calculatiDI potential
compounds Cor specification purposes, those using methods which-determine Al or AI.O. directly should add to the
determined AI,O. mass quantities of P,0 3 • TiO. and any other oxide except Fe.O. which would precipitate with
the ammonium hydroxide group whpn analyzed by the classical method and which is pres~nt in an amnunt 0·05 or
percent by mass or greater. The percentage ( by mass) of minor or trace oxides to b. added to AI,O. by those uaing
direct methods may be obtained by actual analysis or those oxides in the sample beiDg telted or estimated rrom
historical data on thole oxides on cements from the same source, provided that the estimated values are identified
as such,

5.2 Soundae•• 5.3 SettiDI Time - The setting time of sulphate


resisting Portland cement, when tested by the Vieat
5.2.1 When tested by l ..e Chatelier method and apparatus method described in IS : 403 J ( Part 5 )-
autoclave test described in IS: 4031 (Part 3 )..
1fl80· shall conform to the following requirement
1988· unaerated sulphate resisting Portland
cement shall not have an expansion of more than a) Initial setting time in minutes, not Jess
10 mm and 0·8 percent, respectively, than 30, and
5.2.1.1 In the event of cement failing to b) Final setting time in minutes, not more
comply with anyone or both the requirements than 600.
specified in 5.2.1, further tests in respect of each 5.3.1 If cement exhibits false set, the ratio of
failure shall be made as described in IS: 4031 final penetration measured after 5 minutes of
(Part 3 )·1988* from another portion of the completion of mixing period to the initial pene-
sarne sample after aeration. The aeration .hall tration measured exactly alter 20 seconds of com-
be done by spreading out the sample to a depth pletion of mixing period, expressed as percent,
of 75 rom at a relative humidity of 50 to 80 per- shall not be less than 50. In the event of cement
cent for a total period of 7 days_ The expansion exl.iblting f~lse set, the initial and final setting
of cements so aerated shall not be more than time of cement when 'tested by the method describ-
5 rom and 0 6 percent when tested by Le Chatelier ed in IS: 4031 ( Part 5 )-1980· after breaking
method and autoclave test respectively. the false set, shall conform to 5.3_
• Methods of physiral test. (or hydraulic cement: ·M~thod. of physical tfsts for hydraulic cement: Part 5
,art 3 Determination of soundness ( fi,JI ''''i,ion ). Determination of initialan<t finalt.ttiDI time (fi,,' ""i$iON ).

2
11.12_·1-

5.4 Salphate Espaa.loa 6. STORAGE


6.1 The sulphate resisting Portland cement shall
5....1 The sulphate expansion of the sulphate be stored in such a manner as to permit easy
resisting Portland cement when tested by the access for proper inspection and identification,
method described in 5.4.2, shall not be more than and in a suitable weather-tight building to protect
o 045 percent at 11 days. This test is optional and the cement from dampness and to minimize
shall be carried out by agreement between the warehouse deterioration.
purchaser and the manufacturer at the tlme C'f
placing order. 7. MANUFACTURER'S CERTIFICATE
7.1 The manufacturer shall furnish a certificate
5.4.2 For this test a mixture of sulphate resist- to the purchaser or his representative, within 10
ing Portland cement and gypsum should be days of despatch of the cement stating that the
prepared in such proportions that the total SOa material conforms to aJl the requirements of this
content is 7 0 percent by mass. The gypsum standard.
used shall be natural gypsum 100 percent passing 8. DELIVER·_
150 I-&m IS Sieve, at least 9~ percent passing 75
I'm IS Sieve and at least 90 percent passing 45 ",m 8.1 The cement shall be packed in bags [ jute
IS Sieve. Mortar should have proportion of sacking bag conforming to IS: 2580-1982·,
( cement + gypsum) : sand as 1 : 2"75 and water: double hessian bituminized ( eRI type ), multi-
(cement + gypsum ) as 0°485. The sand used wall paper conforming to ]S: 11761-1986t, poly-
shall conform to IS : 650-1966*. The dimension ethylene lined ( CRI type) jute, light weight jute
of mort ar bars shall be 25 x 25 X 250 mm, conforming IS : 12154-1987: woven HDPE Con-
After demoulding, the bars shall be stored horizon- forming to IS: 11652-1986§, woven polypropylene
tally in water. The average expansion of three conforming to IS: 11653-198611, jute synthetic
specimens after 14 days shall be reported. union conforming to IS: 12174-198i~ or any other
approved composite bags] bearing the manu-
5.5 COlDpre••ive StreDltb - The average facturer's name or his registered trade-mark, if
compressive strength of at least three mortar any. The words 'sulphate resisting Portland
cubes (area of face 50 cm 2 ) composed of one cement' and the number of bags (net mass) to
part of cement, three parts of standard sand the tonne or the average net mass (St, 8.2) of
( conforming to IS : 650-1966* ) by mass and P/4 the cement shall be legibly and indelibly marked
+ g"O percent (of combined mass of cement on each bag. The bags shall be in good condition
at the time of inspection.
plus sand) water and prepared, stored and tested
in the manner described in IS : 4031 (Part 6 )- 8.1.1 Similar information shall be provided in
1988t shall be as follows: the delivery advic_es accompanying the shipment
or packed or bulk cement ( St, 8.3 ).
i) 72 ± 1 h, not less than 10 ¥Pa 8.1.2 The bags or packages may also be mark-
ii) 168 ± 2 h, not Jess than 16 MPa ed with the Standard Mark.
iii) 672. ± 4 h, not less than 33 MPa NOTB - The use of the Standard Mark is loverne<!
by the provisions of the Bureau of Indian Standard, Act
NOTB - P is the percentage of water required to 1986and the Rules and Regulations made thereunder.
produce a paste of standard consiltency ( II' 10.3 ). The Standard Mark on products covered by an Indian
Standard conveys the assuranee that they have been
5.6 By arrangement between the purchaser and produced to comply with the requirements of that
the manufactures, transverse strength test of plastic standard under a well-defined system of Inspection, te~t·
ing and quality control which is devised and supervised
mortar in accordance with the method described by DIS and operated b~ the producer. Standard marked
in IS: 4031 ( Part 8 )-1988: may be specified in products are also conrinuouslv checked by DIS for con-
addition to the test specified in 5.5. The permissi- formity to that standard as a further safeguard, Details
ble values of the transverse strength shall be of conditions under which a licence for the use of the
Standard Mark may be granted to manufacturers or
mutually agreed to bet ween the purchaser and producers, may be obtained from the Bureau of Indian
the supplier at the time of placing order. Standards.
8.2 The average net mass of cement per bag
5.7 Notwithstanding the strength requirements shall be 50 kg ( see Appendix A ).
specified in 5.5 and 5.6, sulphate resisting Port-
land cement shall show a progressive increase in -Specification for jute sacking bags (or packing cement
strength (loom the strength at 72 h. ( s"ond ",1isi,,. ).
tSpecification Cor mulriwall paper sacks for cemem,
valved-sewn-gussetted type.
·Specification for standard sand for testing of cement *Specification for lilht weight jute bagl for packing
( firsl "uisifJ1I ). cement
tMethod. of physical tests for hydraulic cement: Part 6 §Sp~cification for hilh density pol) ethvlene (HOPE)
Determination or compressive stren.th of hydraulic cement woven sa"ks for packing cement. .
( other than masonry cement) ( fi,,' ,,,n,i01l ). IlSpecification for pol y proVy)ene ( PP ) woven sacks for
:Me~hods of physical tests for h)'draulic cement: packing cement.
Part 8 Determination of transverse and compressive 'Specification for jute synthetic union bag for packing
strength of plastic mortar usin, prism ( fir,' "visi'li ). cement.

3
IS I 12330 • 1988

8.3 Supplies of cement in bulk may be made by 10.2 Temperature lor Te.tlDI - The
arrangement between the purchaser and the temperature range within which physical tests
supplier ( manufacturer 01" stockists ). may be carried out shall, as far aa possible, be
NOTE - A single bal or container containing 1 000 ~I
27 ± 2°C. The actual temperature during the
or more net mag of cement shall be considered as bulk testing shall be recorded.
supply of cement. Supplies of cement may also be made
in intermediate containers, for example, drums of 200 kg, 10.3 COD8i.teac)' of Staadard CemeDt P••te
by agreement between the pure-haser and the manufac- - The quantity of water required to produce a
turer. paste of standard consistency J to be used for
9. SAMPLING the determination of the water content of' mortar
for the compressive strength tests and for the
9.1 Sample. lor Te.tiDI aad by Whom to determination of soundness and setting time,
be Take. - A sample or samples for testing shall be obtained by the method described in
may be taken by the purchaser or his representa- IS : 4031 ( Part 4 )-1988*.
tive, or by any person appointed to superintend
10.~ IDdepeDdeat Te.tlDI
the work for purpose of which the cement is
required or by the latter's representative. 10.4.1 If the purchaser or his representative
9.1.1 The sam~les shall be taken within three require independent tests, the samples shall be
weeks of the delivery and all the tests shall be taken before or immediately after deliver y at the
commenced within one week of sampling. option of the purchaser or his representative, and
the tests shall be carried out in accordance with
9.1.2 When it is not possible to test the samples this standard on the written instructions of the
within one week, the samples shall be packed purchaser or his representative.
and stored in air-tight containers till such time
that they are tested. 10.4.2 After a representative sample has been
drawn, tests on the sample shall be carried out as
9.2 In addition to the requirements of 9.1, the exped itiously as possible.
methods and procedure of sampling shall be in
accordance with IS : 3535-1986*. 11. REJECTION
9.3 Faellitie. lor Sampll_. aDd Ideatlfiea- 11.1 Cement may be rejected if it doe. not
tloa - The manufacturer or supplier shall comply with any of the requirements of this
afford every facility J and shall provide all labour specification.
and materials for taking and packing the samples
for testing the cement and for subsequent identi- 11.2 Cement remaining in bulk storage at the
fication of cement sampled. mill, prior to shipment, for more than six months,
or cement in bags in local storage in the hands
10. TESTS of a vendor for more than 3 months after comple-
tion of tests, may be retested before use and may
10.1 The sample or samples of cement for test be rejected if it fails to conform to any of the
shall be taken as described in 9 and shall be test- requirements of this specification.
ed in the manner described in the relevant
clauses. .l\fethods of phy~ica 1 tests for hydraulic cement: Part 4
-----. - ----- - Determination of con-istency of standard cement paste
• Methods of sampling hydraulic cements ( ~, sl "vijion ). (first r't'ision ).
IS I 123SO • 1_

APPENDIX A
( Clouses 0.3 and 8.2 )
TOLERANCE aEQ,UIREMENTS FOR THE MASS OF CEMENT PACKED IN BAGS
A-I. The average net masl of cement packed in than 5 percent of the bags in the sample and the
bags at the plant in a sample shall be equal to or minus error in none of such bags in the sample
more than 50 kg. The number of bags in a .shall exceed 4 percent of the specified net mass
sample shall be as given below: of the bag.
Balth Si~e Sample S;z, NOTE - The matter giv~n in A-I and A-I.I are
extracts based on the Standards of Weigh.s and Measure
100 to 150 20 ( Packaged Commodities) Rules, 1977 to which rer.rences
shall be made for full details. Any modification made in
151 to 280 32 these Rules and other related Acts and Ruin would
281 to 500 50 appl y automatleall y,

501 to 1 200 80 A-l.2 In case of a wagon/truck load of 20 to 25


I 20 1 to 3 200 125 tonnes, the overall tolerance on net masl of
cement shall be zero to +0'5 percent.
3 201 and above 200
NOTlC - The mass of a jute aackinl ba. c.aCormiDI
The bags in a sample shall be selected at to IS : 2580·1982. to hold 50 kl of cement il 55 I I. the
random ( SII IS : 4905·1968* ). mass of a double hessian bituminized ( CR I type) bal to
hold 50 kg of cement is 630 I. the mals of a 6-pJy paper
A-I.I The number of bags in a sample shewing bag to hold 50 kl of cement is approximate}y 400 I and
the mass of a polyethylene lined (CRI type) jute ba.
a minus error greater than 2 percent of the to hold 50 kg of cement is approximately 480 I.
specified net mass (50 kg) shall be not more
·Specification (or jute ba.1 for packiDB cement
.Methods Corrandom samplinl_ ( ,'(.o"d "l'is;.,. ).

5
BU~U
·f
of1ndlan St..Ciards

BIS is a statutory institution established under the Bureau of Indian Standards Act, 1986 to promote
harmonious development of the e,,,'~,vities of standardization, marking and quality certification of goods
and attending to connected matters in the country.

BIS h s the copyright of all its publications. No part of these publications may be reproduced in any form
witho the prior permission in writing of BIS. This does not preclude the free use, in the course of
impJem ling the standard, of necessary details, such as symbols and sizes, type or grade designations.
Enquiries relating
, to copyright be addressed to the Dir-ctor (Publications), BIS.

Review of Indian Standards

Amendments are issued to standards as the need arises on the basis of comments. Standards are also reviewed
periodically; a standard along with amendments is reaffirmed when such review indicates that no changes are
needed; if the review indicates that changes are needed, it is taken up for revision. Users of Indian Standards
should ascertain that they are in possession of the latest amendments or edition by referring to the latest issue of
'BIS Catalogue' and 'Standards: Monthly Additions'.

Amendments Issued Since Publication

Amend No. Date of Issue Text Affected

BUREAUOF INDIAN STANDARDS


Headquarters:
Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110 002 Telegrams : Manaksanstha
Telephones: 323 0 I 31, 323 33 75, 323 94 02 (Common to all offices)

Regional Offices: Telephone


Central : Manak Bhavan, 9 Bahadur Shah Zafar Marg 323 76 17
NEW DELHI 110002 { 323 3841
Eastern : 1/14 C. I. T. Scheme VII M, V. I. P. Road, Kankurgachi 337 84 99, 337 85 61
CALCUTTA700 054 { 337 86 26, 337 91 20

Northern : SeQ 335-336, Sector 34-A, CHANDIGARH 160022 60 3843


{ 602025
Southern : c. I. T. Campus, IV Cross Road, CHENNAI 600 113 235 02 16, 235 0442
{ 235 15 19,235 23 15
Western : Manakalaya, E9 MIDC, Marol, Andheri (East) {832 92 95, 832 78 58
MUMBAI 400 093 832 78 91, 832 78 92
Branches : AHMADABAD. BANGALORE. BHOPAL. BHUBANESHWAR. COIMBATORE.
FARIDABAD. GHAZIABAD. GUWAHATI. HYDERABAD. JAIPUR. KANPUR.
LUCKNOW. NAGPUR. PATNA. PUNE. RAJKOT. THIRUVANANTHAPURAM.

Printed at Dee Kay Printen, NewDelhi