You are on page 1of 32

Variable Displacement Pump (A)A10V

Series-31

Industrial & Mobile, Single & Thru Shaft Models, A10V / AA10V

18, 28, 45, 71, 100 & 140 Frame Sizes Available

Same Day Shipment of Units or Parts Orders

DR, DRG, DFR, DFR1, DFLR Controls

SAE & Metric Units

www.FluiDyneFP.com I sales@fluidynefp.com I 586-296-7200


Index

Variable Displacement Pump (A)A10V, Series 31. . .. . .. . .. . .. . .. . .. . .. . .. . .. 4


Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Technical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Ordering Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Fluid Operational Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Noise Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
DR Pressure Control Data, Dimensions . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . 10
DRG Pressure Control Data / Remote Control / Dimensions. . .. . .. . .. . .. . .. . .. . .. . .. . . 12
DFR/DFR1 Pressure / Flow Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
DFLR Pressure / Flow / Power Control / Dimensions . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . 15

Mounting Dimensions, Size 18, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Service Ports on Side; Non Through Drive, Models 62N00 and 12N00. . . . . . . . . . . . . . . . . 17

Mounting Dimensions, Size 28, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18


Service Ports at Side and Rear; Non Through Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
(A)A10V28 Shaft, Metric Mount, and Port Dimensions . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . 19

Mounting Dimensions, Size 45, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20


Service Ports at Side and Rear; Non Through Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
(A)A10V45 Shaft, Metric Mount, and Port Dimensions . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . 21

Mounting Dimensions, Size 71, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22


Service Ports on Side and Rear; Non Through Drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
(A)A10V71 Shaft, Metric Mount, and Port Dimensions . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . 23

2 Variable Displacement Pump (A)A10V, Series 31 www.FluiDyneFP.com


Mounting Dimensions, Size 100, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Service Ports on Side & Rear; Non Through Drive. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . 24
(A)A10V100 Shaft, Metric Mount, and Port Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Mounting Dimensions, Size 140, Series 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26


Service Ports on Side; Non Through Drive, Models 62N00 and 12N00. . . . . . . . . . . . . . . . . 26

Through Drive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Overview of Through Drive Mounting Options / Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Shaft Torque Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Pump Installation Notes . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . 31

www.FluiDyneFP.com Variable Displacement Pump (A)A10V, Series 31 3


Variable Displacement Pump (A)A10V, Series 31

Features
Axial piston pump A10V in swashplate design is used for
hydrostatic transmissions in open loop circuits. Flow is
proportional to drive speed and displacement. By adjusting
the position of the swashplate it is possible to smoothly vary
the flow.

Swash Cylinder Variable Piston Valve DFR


plate block piston plate control valve

Housing
End cover

Shaft

Returning piston

• Flange connections to SAE-UNC or Isometric • Long service life


• 2 case drain ports • Quick response time
• High permissible speeds • Axial and radial loading of drive shaft possible
• Good suction characteristics • Wide range of controls
• Low noise level • Through drive option for multi-circuit system
• High power/weight ratio

4 Variable Displacement Pump (A)A10V, Series 31 www.FluiDyneFP.com


Variable Displacement Pump (A)A10V, Series 31

Technical Data
1. Input operating pressure range
Absolute pressure at port S (A)
P min........................................0.8bar (12 psi)
abs
P max.......................................30bar (435 psi)
abs

2. Output operating pressure range


Pressure at port B
Nominal pressure PN....................280bar (4000 psi)
Peak pressure Pmax...............350bar (5100 psi)
Pressure data to DIN24312

3. Case drain pressure


Maximum pressure of leakage fluid ( at ports L, L1 ). Maximum 7 psi ( 0.5 bar ) higher than input pressure at port
S, but not higher than 30 psi ( 2 bar ) absolute.

4. Direction of flow : ( S to B )

5. Table of values (theoretical values, without considering mh and v ; values rounded)

Size cm3/rev 18 28 45 71 100 140


Displacement Vg max cm /rev (in /rev)
3 3
18 (1.10) 28 (1.71) 45 (2.75) 71 (4.33) 100 (6.1) 140 (8.54)

Max. Speed No max rpm 3300 3000 2600 2200 2000 1800

Max. Flow Oo max L / min (gpm) 59.4 (15.7) 84 (22) 117 (31) 156 (41) 200 (53) 252 (67)

Max. Power Po max kW (HP) 28 (36.6) 39 (51) 55 (72) 73 (96) 93 (124) 118 (156)

Max. Torque Tmax Nm (ft - lb) 80 (58) 125 (91) 200 (146) 316 (230)w 445 (324) 623 (453)
@Vg max, No max

Weight (without fluid) Kg (lbs) 12 (27) 15 (33) 21 (46) 33 (73) 45 (99) 60 (132)

Notes: Values shown are valid for an absolute pressure of 1 bar at suction port. If the flow is
reduced or if the inlet pressure is increased the speed may be increased.

6. Determination of size

Flow qv =
Vg • n • ηv
231
[gpm]
(
qv =
Vg • n • ηv
1000
[L/min]
) V g = Displacement per revolution in in3 (cm 3 )
∆ p = Differential pressure in psi (bar)

( )
n = Speed in rpm (min –1 )
Vg • ∆ p Vg • ∆ p
Torque T = [lb-ft] T= [Nm] η v = Volumetric efficiency
24 • π • η mh 20 • π • η mh
η mh = Mechanical-hydraulic efficiency

( )
η t = Total efficiency
qv • ∆ p qv • ∆ p
Power P= [HP] P= [kW]
1714 • η t 600 • η t

www.FluiDyneFP.com Variable Displacement Pump (A)A10V, Series 31 5


Variable Displacement Pump (A)A10V, Series 31

Ordering Code
(A)A10V(S) O 71 DR / 31 R - P S
Axial Piston Unit
Swash plate variable pump A10V
Swash plate variable pump for industrial A10VS

Mode of Operation
Pump, open circuit O

Size
Displacement Vgmax cm3//rev 18 28 45 71 100 140
(in3//rev) (1.10) (1.71) (2.75) (4.33) (6.10) (8.54)

Control Devices
Pressure control DR
Pressure remote control l l l l l l DRG
Pressure and flow control DFR
Pressure & flow (w/ X port blocked) l l l l l l DFR1
Pressure,Flow & Power control l l l l l l DFLR

Series
Series 31

Direction of Rotation
clockwise R
Viewed from shaft end
counter-clockwise L

Seals
Buna-N (NBR per DIN IS0 1629) ; P
FPM (flurocarbon) V

Shaft End 18 28 45 71 100 140


SAE-splined shaft l l l l l l S

SAE-splined shaft, reinforced (higher thru drive torque) l l l l - - R

SAE splined shaft, smaller size (not for pumps with thru drive) l - l l l - U

SAE- splined shaft, reinforced (U-type shaft) l l l l l - W

SAE- keyed shaft l l l l l l K

Parallel with key DIN 6885 l l l l l l P

6 Variable Displacement Pump (A)A10V, Series 31 www.FluiDyneFP.com


Variable Displacement Pump (A)A10V, Series 31

C 62 N00

Through drives 18 28 45 71 100 140

Without through drive (Non-Thru Drive) l l l l l l N00

With through drive to accept an axial piston pump or a gear pump


Mounting flange SAEJ744 hub sealing to mount
82-2 (A) 3/4” keyed (A-B) axial A10V18 (K) O l l l l l K401)

101-2 (B) 7/8” keyed (B) axial A10V28 (K) - l l l l l K031)

101-2 (B-B) 1” keyed (B-B) axial A10V45 (K) - - l l l l K051)

127-2 (C) 1-1/4” keyed (C) axial A10V71 (K) - - - l l l K081)

127-2 (C) 1-1/2” keyed (C) radial A10V100 (K) - - - - l l K381)

152-4 (D) 1-3/4” keyed (D) axial A10V140 (K) - - - - - l K211)

82-2 (A) 5/8” 9T (A) axial A10V18(U) l l l l l l K01

82-2 (A) 3/4” 11T (A-B) axial A10V18(S,R), 10(S) l l l l l l K52

101-2 (B) 7/8” 13T (B) axial A10V28(S,R), 45(U,W) - l l l l l K68/K02

101-2 (B) 1” 15T ( B - B ) axial A10V45(S,R), 60(U,W) - - l l l l K04

127-2 (C) 1-1/4” 14T (C) axial A10V71(S,R), 100 (U,W) - - - l l l K07/K15

127-2 (C) 1-1/2” 17T (C-C) axial A10V100(S,R), 85(S) - - - - l l K24

152-4 (D) 1-3/4” 13T (D) axial A10V140(S,R) - - - - - l K17


1)
Permitted with reduced thru drive torque

See Thru Drives section for other options


Service Ports
(Pressure port B and Suction port S) 18 28 45 71 100 140
Rear ports, UNC mounting screws l l l l - 61

Opposite side ports, UNC mounting screws l l l l l l 62

Rear ports, metric mounting screws l l l - - 11


Ports 61,
Opposite side ports, metric mounting screws l l l l l 12 11, 91 &
41 non-
Rear ports, UNC mounting screws - - l - - 91 through
drive only
Opposite side ports, UNC mounting screws - - l - - 92

Rear ports, metric mounting screws l - 41

Opposite side ports, metric mounting screws - - l - - 42

Mounting Flange 18 28 45 71 100 140


SAE 2 hole l l l l l - C

ISO 2 hole - l l l l - A

SAE 4 hole - - - - - l D l = available


O = in preparation
- = not available

www.FluiDyneFP.com Variable Displacement Pump (A)A10V, Series 31 7


Variable Displacement Pump (A)A10V, Series 31

Fluid
1. Fluid: AW68 (Q / TCNK 12-2001)

2. Operating viscosity range

V opt = 16 mm2 / s ~ 36 mm2 / s (80-170 sus)

For optimum efficiency and service life we recommend that the operating viscosity (at operating temperature) be
selected in the range:

V opt = opt. operating viscosity 16 ~ 36 mm2 / s

Referred to tank temperature (open loop circuit).



Limits of viscosity range
(The following values are valid for extreme operating conditions):

V min = 10 mm2 / s (60 sus)


For short periods (t ≤ 1 minute) at max. leakage oil temperature of 800C (176 0F)

V max = 1000 mm2 / s


For short periods upon cold start

3. Temperature range

T min = -200C (-130F) : T max = +800C (+1760F)

4. Filtration

In order to ensure reliable operation of the axial piston unit the operating fluid must be maintained to a cleanliness
class of at least 16 / 19 to IS04406. This may be achieved with filter elements with a cleanliness code of 10µm.

Installation Notes
The pump housing must be filled with fluid during commissioning and remain full when operating. The concentricity between
engine transmission shaft and pump shaft must be less than 0.05mm (0.002 in).

8 Variable Displacement Pump (A)A10V, Series 31 www.FluiDyneFP.com


Variable Displacement Pump (A)A10V, Series 31

Noise Level
Characteristics for pump
Measured in an sound chamber
Distance from microphone to pump = 3.3 ft (1m)
Measuring error: + 2 dB(A)
Fluid: Hydraulic oil to ISO VG 46 DIN 51519, t=122˚ F(50˚C)

*Sound data representative of piston pumps of this design.

www.FluiDyneFP.com Variable Displacement Pump (A)A10V, Series 31 9


Variable Displacement Pump (A)A10V, Series 31

DR Pressure Control
The pressure control serves to maintain a constant pressure
in the hydraulic system within the control range of the pump.
The pump therefore supplies only the amount of hydraulic
fluid required by the actuators. Pressure may be smoothly
set at the pilot valve.

Static characteristic
( at n1 = 1450rpm ; toil = 500C) 1220F

Hysteresis and pressure increase P


(Flow)

Setting range Ports


20 280 B Pressure port
(290 psi) (4000 psi) S Suction port
Operating pressure p[bar] L, L1 Case drain ports (L1 sealed)

Control Data
Hysteresis and repetitive accuracy ...................... max. 3 bar (45 psi)

Size 18 28 45 71 100 140


Bar (psi) 4 (58) 4 (58) 6 (87) 8 (116) 10 (145) 12 (174)

Pilot oil consumption...............................max. approx. 3 L/min (0.8 gpm)

10 Variable Displacement Pump (A)A10V, Series 31 www.FluiDyneFP.com


Variable Displacement Pump (A)A10V, Series 31

Unit Dimensions DR
Service Ports at Rear; Models 61N00 and 11N00
Sizes 18 to 140

Mounting of pilot Mounting of pilot


valve for clockwise valve for anticlockwise
direction of rotation direction of rotation

Unit Dimensions DR
Service Ports on Side; Models 62N00 and 12N00
Sizes 18 to 140
Mounting of pilot
valve for anticlockwise
direction of rotation

Mounting of pilot
valve for clockwise
direction of rotation

Sizes A1 mm (in) A2 mm (in) A3 mm (in) A4 mm (in)


18 110 (4.33”) - 105 (4.13”) 126 (4.96”)
28 108.5 (4.27”) 226.2 (8.91”) 108.5 (4.27”) 136 (5.35”)
45 108.5 (4.27”) 245 (9.65”) 108.5 (4.27”) 146 (5.75”)
71 106 (4.17”) 279 (10.98”) 108.5 (4.27”) 160 (6.3”)
100 108.5 (4.27”) 344 (13.54”) 108.5 (4.27”) 158 (6.22”)
140 126 (4.964”) - 127 (5.0”) 169 (6.65”)

www.FluiDyneFP.com Variable Displacement Pump (A)A10V, Series 31 11


Variable Displacement Pump (A)A10V, Series 31

DRG Pressure Control, Remote Control


Function and design for DRG.

A pressure relief valve may be externally piped to port X for remote Customer
Supplied
control purposes. It is not, however, included with DRG control.

The differential pressure at the pilot valve is set as standard to 20


bar (290 psi) and this results in a pilot flow of (0.4gpm) 1.5 L/min.
If another setting is required (in the range 10-22 bar), please state
this in clear text.

Static Characteristic
( at n1 = 1450rpm ; toil = 500C) 1220F

Hysteresis and pressure increase P

Ports
B Pressure port
S Suction port
(Flow)

L, L1 Case drain ports (L1 sealed)


X Pilot pressure port

Setting range

20 280
(290 PSI) (4,000 PSI)
Operating pressure p [bar]

Control Data
Hysteresis and repetitive accuracy p...........max 3 bar (45 psi)

Max. pressure increases


Size 18 28 45 71 100 140
Bar (psi) 4 (58) 4 (58) 6 (87) 8 (116) 10 (145) 12 (174)

Pilot oil consumption...............................................max. approx. 4.5 L/min(1.19gpm)

12 Variable Displacement Pump (A)A10V, Series 31 www.FluiDyneFP.com


Variable Displacement Pump (A)A10V, Series 31

DFR/DFR1 Pressure/Flow Control


In addition to the pressure control function, the pump flow
may be varied by means of a differential pressure at the
actuator (e.g. an orifice).

In model DFR1 the X orifice is plugged. Customer With DFR1


Supplied plugged

Static Characteristic
( at n1 = 1450rpm ; toil = 500C) 1220F

Hysteresis and pressure increase P


(Flow)

Ports
B Pressure port
S Suction port
Setting range L, L1 Case drain ports (L1 sealed)
20 280 X Pilot pressure port
(290 psi) (4,000 psi)
Operating pressure p[bar]

Flow Control/Differential Pressure Static characteristic at variable speed

Standard setting: 14 bar (203psi). If a different setting is


required, please state in clear text.
(Flow)

When port X is unloaded to tank, a zero stroke pressure


(“stand by”) of p = 18 +/- 2 bar (260 +/- 30 psi) results.

Control Data (Speed)n


For pressure control technical data see DR Pressure control

Max. flow deviation (hysteresis and increase) measured at drive speed n = 1450 rpm
Size 18 28 45 71 100 140
Qmax (gpm) L/min 0.9 (0.24) 1.0 (0.26) 1.8 (0.48) 2.8 (0.74) 4.0 (1.06) 6.0 (1.6)
Pilot oil consumption DFR...........................max. approx. 3-4, 5 L/min (0.70-1.19 gpm)
Pilot oil consumption DFR1.........................max. approx. 3 L/min (0.70 gpm)

www.FluiDyneFP.com Variable Displacement Pump (A)A10V, Series 31 13


Variable Displacement Pump (A)A10V, Series 31

Unit Dimensions DFR / DFR1 / DRG


Service Ports at Rear; Models 61N00 and 11N00
Sizes 18 to 140

Mounting of pilot Mounting of pilot


valve for clockwise valve for anticlockwise
direction of rotation direction of rotation

Unit Dimensions DFR / DFR1 / DRG


Service Ports on Side; Models 62N00 and 12N00
Sizes 18 to 140

Mounting of pilot
valve for anticlockwise
direction of rotation

Mounting of pilot
valve for clockwise
direction of rotation

Sizes A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 X


mm (in)
18 - 36(1.42) - - - - 166(6.54) 105(4.13) 40(1.57) 109(4.29) 126(4.96) 7/16-20UNF-2B
28 73(2.87) 36(1.42) 108.5(4.27) 43(1.69) 209.2(8.23) 226.2(8.9) 176(6.9) 108.5(4.27) 40(1.57) 119(4.69) 136(5.35) 7/16-20UNF-2B
45 82 (3.21) 36(1.42) 108.5(4.27) 40(1.57) 229(8.98) 245(9.65) 191(7.5) 108.5(4.27) 40(1.57) 129(5.08) 146(5.75) 7/16-20UNF-2B
71 91 (3.60) 36(1.42) 106(4.17) 42(1.65) 262(10.31) 279(10.98) 219(8.6) 108.5(4.27) 40(1.57) 143(5.63) 160(6.30) 7/16-20UNF-2B
100 96.3 (3.79) 36(1.42) 108.5(4.27) 40(1.57) 327(12.87) 344(13.54) 287(11.3) 108.5(4.27) 40(1.57) 141(5.55) 158(6.22) 7/16-20UNF-2B

140 140 (5.51) 36(1.42) - 27(1.06) 353(13.9) 379(14.92) 258(10.16) 127(5.0) 27(1.06) 183(7.2) 209(8.23) 9/16-18UNF-2B

14 Variable Displacement Pump (A)A10V, Series 31 www.FluiDyneFP.com


Variable Displacement Pump (A)A10V, Series 31

DFLR Pressure / Flow / Power Control


In order to achieve a constant drive torque with a varying
operating pressure, the swivel angle and with it the output
flow from the axial piston unit is varied so that the product
of flow and pressure remain constant.

Flow control is possible below the limit of the power curve.

Customer to
Supply

Maximum power curve


100

75
(Flow)

50

Minimum power curve


25

05 0 100 150 200 250 300

Operating pressure p[bar] Ports


B Pressure port
S Suction port
L, L1 Case drain ports (L1 sealed)
X Pilot pressure port

The power characteristic is factory - set, so please enter details in clear text, e.g. 20kW at 1450 rpm (5HP, 1800RPM).

Control Data
For pressure control technical data see DR Pressure control.
For flow control technical data see DFR control.

Start of control.............................................from 80 bar (1,160 psi)


Pilot oil consumption....................................max. approx. 5.5 L/min (1.45 gpm)

www.FluiDyneFP.com Variable Displacement Pump (A)A10V, Series 31 15


Variable Displacement Pump (A)A10V, Series 31

Unit Dimensions DFLR


Service Ports at Rear; Models 61N00 and 11N00
Sizes 18 to 140

Mounting of pilot
Mounting of pilot valve for clockwise
valve for anticlockwise direction of rotation
direction of rotation

Power valve

Unit Dimensions DFLR


Service Ports on Side; Models 62N00 and 12N00
Size 18 to 140

Mounting of pilot Mounting of pilot


Power valve valve for anticlockwise valve for clockwise
direction of rotation direction of rotation

Sizes A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 X


mm(in)
28 120(4.72) 87.5(3.44) 47(1.9) 108.5(4.27) 48(1.89) 226.2(8.9) 43(1.69) 108.5(4.27) 140(5.51) 36(1.42) 108.5(4.27) 40(1.57) 119(4.69) 136(5.35) 7/16-20UNF-2B x 0.39H

45 129(5.08) 92.8(3.65) 47(1.9) 112.5(4.43) 55(2.17) 245(9.65) 40(1.57) 108.5(4.27) 155(6.10) 36(1.42) 108.5(4.27) 40(1.57) 129(5.08) 146(5.75) 7/16-20UNF-2B x 0.39H

71 139(5.47) 103.5(4.07) 47(1.9) 124(4.88) 69(2.72) 279(10.98) 42(1.65) 106(4.17) 218.8(8.61) 36(1.42) 108.5(4.27) 40(1.57) 143(5.63) 160(6.30) 7/16-20UNF-2B x 0.39H

100 145(5.71) 112.6(4.43) 47(1.9) 132.5(5.22) 110.8(4.36) 344(13.54) 40(1.57) 108.5(4.27) 250(9.84) 36(1.42) 108.5(4.27) 40(1.57) 148(5.83) 165(6.50) M14 x 1.5-6H

140 148(5.83) 140(5.51) - 140(5.51) 99(3.90) 379(14.92) 209(8.23) 183(7.2) - - 127(5.00) 27(1.06) 183(7.29) 209(8.23) 9/16-18UNF-2B x 0.51H

16 Variable Displacement Pump (A)A10V, Series 31 www.FluiDyneFP.com


Mounting Dimensions, Size 18, Series 31

ServiceUnit
Ports on Side; Size
dimensions, Non 18,
Through Drive, Models 62N00 and 12N00
Series 31
Without Considering Adjustment Dimensions in inches (mm).
(A)A10VSO 18, Serive ports on side, Models 62N00 & 12N00
(A)A10VSO 18, Service ports on side, Models 62N00 & 12N00 View W

3.27 (83)

1.87 (47.6)
0.79 (20)
0.25 (6.3) V
Flange SAE J744
B

)
L

(11
82-2 (A)

43
0.
DIA 3.2479 (Ø82.55 h8

2.48 (63)
12N00
)

4 x M10 (0.67)

7)
(17) deep 0.87 (22.2)

(6
64
2.
3.2500

2.48 (63)
View V

2.60 (66)
2.52 (64)

2.06 (52.4)
0.45 (11.5)

0.98 (25)
L1
4.19 (106.4)
1 .69 (43)
5.98 (152) S
5.71 (145)
7.68 (195) mech.
12N00
displacement
4 x M10 (0.67)
W limiter 1.03 (26.2)
(17) deep

Shaft
Shaft ends
ends
K Parallel with key R Splined shaft 3/4 in 11T S Splined shaft 3/4 in 11T U Splined shaft 5/8 in 9T
ISO 3019-1 19-1 16/32 DP 2) 16/32 DP 2) 16/32 DP 2)
SAE J744-19-4 (A-B) SAE J744-19-4 (A-B) SAE J744-16-4 (A)
0.1884
0.1874
(4.76 +0.025 )
1/4-20UNC-2B
0.83 (21.1)

Centering 3)
R3.15x6.7 DIN332
3/4 in

Ø 3/4 in
)

Centering 3)
–0.02

R3.15x6.7 DIN332
1.13 (28.6) 0.55
DIA 0.7500 (Ø19.05

0.87 (22)
0.10 (2.5) (14)
1.18 (30) 0.62 (15.8)
0.7492

1.50 (38) 1.50 (38) 0.94 (23.8)


1.25 (31.8)
1.30 (33) usable spline length
1.61 (41)

2) ANSI B92.1a-1976, 30° pressure angle, flat root side fit, flank centering, tolerance class 5

Ports
Designation Port for Standard Size Peak Tightening
Ports Pressure
Tightening torques, max. 2) Torque Max
B Pressure port (standard pressure range) SAE J518 3/4 in [psi (bar)] [lb-ft (Nm)]
B PressureThreading
port (standard pressure range) ISO
in bolt holes SAE
68 J5183/8-163/4 in 0.79 (20) deep
UNC-2B; 29 lb-ft (40 Nm)
Threading
S Inletinport
bolt holespressure range)
(standard SAEISO
J518 68 1 in 3/8-16 UNC-2B; 0.79 (20) deep 5100 (350) 29 (40)
Threading in bolt holes ISO 68 3/8-16 UNC-2B; 0.79 (20) deep 29 lb-ft (40 Nm)
S InletL/L(standard pressure range )
C ase drain port (L 1 plugged)
SAE J5189/16-18
ISO 11926
1 UNF-2B
in 59 lb-ft (80 Nm)
Threading in bolt holes ISO 68 3/8-15 UNC-2B; 0.79 (20) deep 75 (5) 29 (40)
1
1)
ANSI B92.1a-1976, pressure angle 30 °, flat root side fit, tolerance class 5
L,L1 Case drain
See (L1 plugged)
safety information ISO 11926 9/16-18 UNF-2B 30 (2) 59 (80)
2)

3)
Axial locking of the coupling e.g. via clamping coupling or radial mounted binding screw
X Pilot Pressure ISO 11926 7/16-20 UNF-2B; 0.39 (10) deep 5100 (350) 29 (40)
X Control pressure for DG control DIN 3852 R 1/4 in 1740 (120) 48 (70)

1) Dependent on the installation position, port L or L1 must be connected

www.FluiDyneFP.com Variable Displacement Pump (A)A10V, Series 31 17


Mounting Dimensions, Size 28, Series 31
18/44 Bosch Rexroth Corporation (A)A10V(S)O | RA 92701-A/12.09

Service Ports at Side and Rear; Non Through Drive


Dimensions,
Without Consideringsize 28
Adjustment

Port Valve
Valve mounting
mountingfor
Portplate
plate62/12
62 counter clockwise
for
V counter clockwise
rotation
0.25 (6.3) rotation
5.47 (13 9)
0.37 (9.5) 3.54 (90 ) B

)
(14
L X L

max. 4.33 (110)


Flange SAE J744

55
101-2 (B)

0.
45°
45°

X
3.15 (80)

DI
3.9979 (Ø101.6 h8

6.8
)

(Ø 5
17
4)

1.57 (40)
4)
(7
2.91
DIA 4.0000

2.91 (74)
3.15 (80)

0.55 (14) 5.75 (146)


1.57 (40) L1 S
6.46 (164) 6.46 (164)
7.64 (194) 3.29 (83.5) 4.68 (119 )
5.35 (13 6)
W 2.87 (7 3)
Port plate 61/11
Port plate 61
1.87 (4 7.6)
0.79

0.87 (22.2)
0.37 (9.5) 3.54 (90 ) B
max. 4.45

0.25 (6.3) L (20)


X
(113)
1.69 (43)
3.9979 (Ø101.6 h8
)

(45)
Z 1.77
(45)
1.77
DIA 4.0000

3.11 (79)

0.55 (14)
1.19 (30.2)

1.25 (32) S
1.57 (40) L1
6.69 (170 ) 2.31
8.23 (20 9)
8.90 (226) (58.7)
Valve
Valvemounting
mountingfor
for
counter clockwise
counter clockwise
rotation
rotation
View
ViewVV View
ViewWW
0.79 (20)

0.87 (22.2)
S
2.31 (58.7)
1.26 (32)
(47.6)
1.87

B
1.19
(30.2)
11/12N00 threads,
M10; 17 deep

18 Variable Displacement Pump (A)A10V, Series 31 www.FluiDyneFP.com


Drive shafts
Drive shafts
Mounting Dimensions,
K Parallel with key
K Parallel with key
ISO 3019-1 22-1
Size 28, Series 31
ISO 3019-1 22-1

(A)A10V28 Shaft, Metric Mount, and Port Dimensions


without considering adjustment
Shaft P, Flange A

Z ; View W View H

RA 92701-A/12.09 | (A)A10V(S)O Bosch R

Dimensions, size 28
S Splined shaft 7/8 in 13T 16/32 DP 1) R Splined shaft 7/8 in 13T 16/32 DP 1)
SAE J744- 22-4 (B)
1/4-20UNC-2B

1/4-20UNC-2B
1/4-20UNC-2B

1/4-20UNC-2B
DIA 7/8 in

DIA 7/8 in
Drive shafts
DIA 7/8 in

DIA 7/8 in
K Parallel with key
0.63ISO
K(163019-1
)
Parallel 22-1
with key
0.63 (16 ) ISO 3019-1 22-1
0.63 (16 )
0.99 (25. 1) 0.63 (16 )
0.99 (25. 1) 1.30 (33. 1) Usuable spline length 0.98 (25)
1.30 (33. 1) Usuable spline length 0.98 (25)
1.61 (41) 1.61 ( 41)
1.61 (41) 1.61 ( 41)

W Splined Shaft 3/4 in 11T 16/32 DP 1)


U Splined Shaft 3/4 in 11T 16/32 DP 1) SAE J744 - 19-4 (A-B)
SAE J744- 19-4 (A-B)

1/4-20UNC-2B
1/4-20UNC-2B
1/4-20UNC-2B
1/4-20UNC-2B

DIA 3/4 in
DIA 3/4 in
DIA 3/4 in
DIA 3/4 in

0.55 ( 14 )
0.55 (14) 0.55 ( 14 ) Usuable spline length 0.83 ( 21)
0.55 (14) Usuable spline length 0.83 ( 21)
1.18 (3 0)
1.18 (3 0) 1.50 (3 8) 1.50 (3 8)
1.50 (3 8) 1.50 (3 8)

1) ANSI B92.1a-1976, 30° pressure angle, flat root side fit, flank centering, tolerance class 5

Ports (A)A10V 28
1/4-20UNC-2B

Designation Port for Standard Size Peak press. Tightening State


[psi (bar)] Torque, Max
DIA 7/8 in

[lb-ft (Nm)]
B Service line (standard pressure SAE J518 3/4 in 29 (40) O
range) Fixing thread ISO 68 3/8-16 UNC-2B; 0.79 (20) deep 5100 (350)
0.63 (16 )
S Inlet (standard pressure range ) SAE J518 1 1/4 in 0.99 (25. 1) 48 (85) O
Fixing thread ISO 68 7/16-14 UNC-2B; 0.94 (24) deep 75 (5) Usuable spline length
1.30 (33. 1)
L,L1 Case drain (L1 plugged) ISO 11926 3/4-16 UNF-2B; 0.47 (12) deep 1.61 (41)30 (2) 118 (160) O1)

X Pilot pressure ISO 11926 7/16-20UNC-2B; 0.47 (12) deep 5100 (350) 29 (40) O
X Control pressure for DG control DIN 3852 R 1/4 in 1740 (120) 48 (70) O

1) Dependent on the installation position, port L or L1 must be connected


O = Must be connected
1/4-20UNC-2B

www.FluiDyneFP.com Variable Displacement Pump (A)A10V, Series 31 19


IA 3/4 in
Mounting Dimensions, Size 45, Series 31
22/44 Bosch Rexroth Corporation (A)A10V(S)O | RA 92701-A/12.09

Service Ports at Side


Dimensions, sizeand
45 Rear; Non Through Drive
Without Considering Adjustment

Port Plate 62/12 N00


V
0.37 (9.5) 6.06 (154)

3)

max. 4.33 (110)


0.25 (6.3) 3.78 (96 ) )
14

(8
Ø

27
5(
Flange SAE J744 L X 5

3.
101-2 (B) 0. L
h8)

3.54 (90)
45° 45°

1.57 (40)
X
3.9979 (Ø101.6
DIA 4.0000

3.17 (80.5)
3.54 (90)
0.56 (14.3) L1
5.75 (146)
1.77 (45)
7.24 (184) 7.24 (184)
8.62 ( 219 ) 3.68 (93.5) 5.08 (129)
Control
Control valve
valve 5.75 (146)
mounting
mountingforfor counter
counter
Port Plate 61/11 N00 clockwise rotation
clockwise rotation View Z
W
3.23 (82)
2.06 (52.4) B
0.37 (9.5) 8.98 (228)

1.03 (26.2)
0.98
max. 4.33 (110)

0.25 (6.3) 3.78 (96 )


(Ø25)
L
X
h8)
3.9979 (Ø101.6

(50)
1.97
40
DIA 4.0000

(50)
1.97
3.46 (88)

Flange SAE J744 S


(35.7)
101-2 (B) 0.56 (14.3) L1
1.40

1.57
1.77 (45) (Ø40)
7.44 (18 9)
9.65 (245) 2.75
(69.9 )
Control
Controlvalve
valve
mounting
mountingforforcounter
counter
View
ViewV V View
ViewWW clockwise
clockwise rotation
rotation

1.03 (26.2) B S
2 .7 5 (69.9)
1.57 (Ø 4 0 )
(52.4)
(Ø25) 2 .0 6

11/12N00 threads M12; 20 deep


0 .9 8

1.40
11/12N00 threads M10; 17 deep (35.7)

20 Variable Displacement Pump (A)A10V, Series 31 www.FluiDyneFP.com


Drive shafts

S Splined shaft 1 in 15T 16/32 DP 1) 1)


R Splined shaft 1 in 15T 16/32 DP
Mounting Dimensions, Size 45, Series 31
SAE J744 - 25-4 (B-B)
RA 92701-A/12.09 | (A)A10V(S)O
SAE J744 - 25-4 (B-B)
Bosch Rexroth Corporation 23/44
RA 92701-A/12.09 | (A)A10V(S)O Bosch Rexroth Corporation 23/44

1/4-20UNC-2B

1/4-20UNC-2B
Dimensions, size 45
Dimensions, size 45
(A)10V45 Shaft, Metric Mount, and Port Dimensions

DIA 1in
DIA1 in
Drive shafts Drive shafts
S Splined shaft 1 in 15T 16/32 DP 1) 0.63 (16 )
S Splined shaft 1 in 15T 16/32 DP S Splined shaft 1 in 15T 16/32 DP R Splined shaft 1 inR15TSplined
1)
16/32R DPshaft 1 in 115T
1) shaft
Splined 16/32
0.63
in 15T DP
16/32(16
DP) 1)
SAE J744 - 25-4 (B-B) 1.18 (3 0)
SAE J744 - 25-4 (B-B) SAE J744 - 25-4 (B-B) SAE J744 - 25-4 (B-B) SAE J744 SAE -J744
25-4 (B-B)
- 25-4 (B-B)
1.50 (3 8) Usable 1.16 (29.5)
1.81 (45.9) spline length

1/4-20UNC-2B

1/4-20UNC-2B
1/4-20UNC-2B

1/4-20UNC-2B
1.81 (45.9)

DIA 1in
DIA1 in

DIA 1in
DIA1 in

U Splined shaft 7/8 in 13T 16/32 DP 1) WSplined shaft 7/8 in 13T 16/32 DP 1)
0.63 (16 )
SAE J744 - 22-4 (B) 0.63 (16 ) 1.18 (3 0)
SAE J744 - 22-4 (B ) 0.63 (16 )
1.18 (3 0) 0.63 (16 )
1.50 (3 8) Usable 1.16 (29.5)

1/4-20UNC-2B
1.50 (3 8) Usable 1.16 (29.5) spline length
1/4-20UNC-2B

1.81 (45.9)
1.81 (45.9) spline length 1.81 (45.9)
1.81 (45.9)

DIA 7/8in
DIA 7/8in

U Splined shaft 7/8 in 13T 16/32 DP 1) W Splined shaftshaft


WSplined 7/8 7/8
in 13T
in 13T16/32 DP
16/32 DP 1)
U Splined shaft 7/8 in 13T 16/32 DP SAE SAE J744 -J744
22-4 (B)(B )
U Splined shaft 7/8 in 13T 16/32 DP 1) J744 - 22-4 (B) SAE
WSplined shaft 7/8 in 13T 16/32 DP 1) - 22-4
SAE J744 - 22-4 (B)
SAE J744 - 22-4 (B) SAE J744 - 22-4 (B ) 0.63 (16 )

1/4-20UNC-2B
1/4-20UNC-2B

0.63 (16 ) Usable

1/4-20UNC-2B
0.98 (25)
1/4-20UNC-2B

DIA 7/8in
spline length
DIA 7/8in

0.98 (25. 1)
1.61 ( 41)

DIA 7/8in
DIA 7/8in

1.61 ( 41)
0.63 (16 )
0.63 (16 ) Usable 0.98 (25)
1) ANSI B92.1a-1976, 30° pressure angle, flat root side fit,
0.98flank 0.635(16 )
centering, tolerance class
(25. 1) spline length
0.63 (16 ) Usable 1.61 ( 41)
1.61 ( 41) 0.98 (25)
0.98 (25. 1) spline length K Parallel with key
1.61 ( 41) ISO 3019-1 25-1
1) 1.61
ANSI B92.( 141)
a-1976, 30° pressure angle, flat root side fit, flank centering, tolerance class 5
KK Parallel
Parallel with
with key key
1) ANSI B92.1a-1976,
1) ANSI 30°
B92.1a-1976, 30° pressure
pressure angle,
angle, flatside
flat root root
fit, side fit, flank centering,
flank centering, tolerance
tolerance class 5 class 5 ISO 3019-1
ISO 3019-1 25-1
25-1
K Parallel with key
Shaft P, ISO Flange A ISO 3019-1 25-1
25 mm Ø Shaft

Ports
Ports
Ports (A)A10V45
Ports
Designation Port for Standard Size Peak press. Tightening State
[psi (bar)] Torque, Max
[lb-ft (Nm)]
B Service line (standard pressure SAE J518 1 in 29 (40) O
range) ISO 68 3/8-16 UNC-2B; 0.71 (17) deep 5100 (350)
Fixing thread
S Inlet (standard pressure range) SAE J518 1 1/2 in 66 (90) O
Fixing thread ISO 68 1/2-13 UNC-2N; 0.87 (22) deep 75 (5)
L, L1 Case drain ISO 11926 7/8-14 UNF-2B 30 (2) 177 (240) O1)

X Pilot pressure ISO 11926 7/16-20 UNF-2B; 0.39 (10) deep 5100 (350) 29 (40) O
X Control pressure for DG control DIN 3852 R 1/4 in 1740 (120) 48 (70) O

1) Dependent on the installation position, Port L or L1 must be connected


O = Must be connected
www.FluiDyneFP.com Variable Displacement Pump (A)A10V, Series 31 21
Mounting Dimensions, Size 71, Series 31
orporation 26/44
26/44 Bosch
Bosch Rexroth
Rexroth Corporation
Corporation (A)A10V(S)O | RA 92701-A/12.09 (A)A10V(S)O
(A)A10V(S)O || RA
RA 92701-A/12.09
92701-A/12.09

ize 71Service
Without
Ports on Side and Rear; Non Through Drive
Dimensions, size 71
Considering Adjustment
Before finalizing your design request
a certified installation drawing.
Dimensions in inches and (mm).
Before
Before finalizing
finalizing your
aa certified
your design
certified installation
design request
request
installation drawing.
drawing.
Dimensions in
Dimensions in inches
inches and
and (mm).
(mm).
d flow control;DFR/DFR1
clockwise
DFR/DFR1 rotation
Pressure andand
Pressure flowflow
control; clockwise
control; rotationrotation
clockwise

With port plate 92 With


Withport
With port plate
port plate 92
plate 92 (others available)
92

7.20 (18 3) V0.50 V(E)


0.50 (12
(12 .7) 7.20
7.20 (18
(18 3) V

)
.7) 3) V

))
8

)) (9(988
4.53 (115 )
) (9
0.24
0.24 (6
(6 )) 4.53
4.53 (115
(115 ))
(18 .86

00. . 4.33 (110)

(1(188 .8.866

(110)
4.33(110)
L XFlange
Flange SAE
SAE J744
3
J744 LL X

33
X
127-2
127-2 (C)
(C)

max.4.33
71

45°
4.09 (104)

7711
45°LL 4455°

(104)
L
4455°°

4.09(104)
0.

max.
A

max.
1.57 (40) DDIAIA
X
h8
))

DI

XX
(Ø127 h8

4.09
4.9975 (Ø127

(40)
1.57(40)
1.57
3.62 (92)
4.09 (104)
5.0000

(92)
(104)
DIA5.0000

3.62(92)
4.9975

4.09(104)

3.62
4.09
DIA

1 (18 ) L1 0.71
0.71 (18
(18 )) L1
7.13 (181)
9 (5 3) L1 7.13
7.13 (181)
(181)
2.09
2.09 (5
(5 3)
3) 8.27 ( 210 ) 8.27 (( 210
8.54 (2 17 ) 8.54 (2 8.27 210 ))
8.54
4.23 (2 17
(107.5) 17 )) 5.63 (143) 4.23
10 .12 (257) 10 4.23 (107.5)
(107.5) 5.63
5.63 (143)
(143)
10 ..1
122 (257)
(257) 6.30 (160 ) 6.30
6.30 (160
(160 ))
Valve mounting for Valve mounting for
Valve mounting
Valve mounting for
for
counter clockwise counter
counter clockwise
clockwise
W counter clockwise
rotation W(F)
W
W rotation
rotation
rotation
View V View W
View V View W View V
View V View
View View
E W
W View F
Model 92 Model 92
2.06 (52.4) 1.69 2.06 1.69
2.06 (52.4)
(52.4) 1.69
0.98 (25) (42.9) (42.9)
(42.9)
0.98
0.98 (25)
(25)
(26.2)

(26.2)
(26.2)
1.03

1.03
1.03
3.06 (77.8)

(77.8)
3.06(77.8)
(50)
1.97

(50)
1.97
(50)
1.97

S SS
3.06

B B
B
View Z View Z
View
View Z
Z
With port plate 91 With
With port
With port plate
port 91
plate 91
plate 91
3.62 (92) 3.62
3.62 (92)
(92)
10.31 (262) 0.50
0.50 (12
(12 .7)
.7) 1.03(262)
10.31
10.31 (262) (26.2) 1.03
1.03 (26.2)
(26.2)
4.53 (115 ) 0.24
0.24 (6
(6 )) 4.53 (115
B ) 0.98 (25) 0.98 (25)
4.53 (115 ) B 0.98 (25)
max. 4.33 (110)

B
(110)
4.33 (110)
2.06 (52.4)

L Flange
Flange SAE
SAE J744
J744
(52.4)

L
2.06 (52.4)

127-2 (C)
127-2 (C)
2.28 (58)
max.4.33

B
(58)

BB
L X
2.28 (58)

LL X
X
2.06
1.57 (40)
h8

(40)
))

X
(Ø127 h8

1.57(40)
XX

max.

2.28
4.9975 (Ø127

1.57

Z Z
Z
5.0000
DIA5.0000
4.9975

2.28 (58)

(58)
2.28 (58)

S SS
1.69 (42.9)

(42.9)
1.69(42.9)
2.28
DIA

S SS
1.69

1 (18 ) L1 0.71
0.71 (18
(18 )) 1.97
L1
L1 1.97
1.97
9 (5 3) 2.09
2.09 (5
(5 3)
3) (50)
Valve mounting for (50)
(50)
8.78 (223) 8.78
8.78 (223)
(223)3.06 Valve
Valve mounting
Valve mounting for
mounting for
10.98 (2 79 ) 10.98 counter clockwise 3.06
3.06
10.98 (2 79
79 ))
(2(77.8) counter
counterclockwise
counter clockwise
clockwise
rotation (77.8)
(77.8) rotation
rotation
rotation

22 Variable Displacement Pump (A)A10V, Series 31 www.FluiDyneFP.com


Mounting Dimensions, Size 71, Series 31

5/16-18UNC-2B
DIA 1 1/4in
(A)10V71 Shaft, Metric Mount, and Port Dimensions
0.75 (19 )
1.56 (39.5)
1.87 (47.5)
2.18 (55.4)
S Splined shaft 1 1/4 in 14T 12/24 DP R Splined shaft 1 1/4 in 14T 12/24 DP U Splined shaft 1 in 15T 16/32 DP
SAE J744- 32-4 (C) 2) SAE J744- 32-4 (C) 2) SAE J744- 25-4 (B-B) 2)

5/16-18UNC-2B

5/16-18UNC-2B
DIA 1 1/4in
5/16-18UNC-2B

1/4-20UNC-2B

DIA 1 1/4in
5/16-18UNC-2B
DIA 1 1/4in

DIA 1 in
DIA 1 1/4in
0.75 (19 ) 0.75 (19 )
1.56 (39.5) Usable 1.50 (3 8)
1.87 (47.5) spline length
2.18 (55.4)
0.63 (16 ) 2.18 (55.4)
0.75 (19 ) 0.75 (19 ) 1.18 (3 0)
1.56 (39.5) Usable 1.50 (3 8)
1.87 (47.5) spline length 1.50 (3 8)
2.18 (55.4) 2.18 (55.4)
5/16-18UNC-2B

1.81 (45.9)

1/4-20UNC-2B
1/4-20UNC-2B
DIA 1 1/4in

DIA 1 in
DIA 1 in
1/4-20UNC-2B

0.63 (16 )
1/4-20UNC-2B

0.63 (16 )
0.75 (19 ) 1.18 (3 0)
Usable 1.18 (3 0)
Usable 1.50 (3 8) 1.50 (3 8) spline length
DIA 1 in
DIA 1 in

spline length Shaft P, ISO Flange A 1.81 (45.9)


2.18 (55.4) 32 mm Ø1.81 (45.9)
Shaft
W Splined shaft 1 in 15T 16/32 DP
SAE0.63
J744-(16 ) (B-B) 2)
25-4 K Parallel with key
0.63 (16 ) ISO 3019-1 32-1
1.18 (3 0)
Usable 1.18 (3 0)
1.50 (3 8) spline length
1.81 (45.9)
1/4-20UNC-2B

1.81 (45.9)
DIA 1 in

0.63 (16 )
Usable 1.18 (3 0)
spline length
1.81 (45.9)

2) ANSI B92.1a-1976, 30° pressure angle, flat root side fit, flank centering, tolerance class 5

Ports (A)A10V71
Designation Port for Standard Size Peak press. Max State
[psi (bar)] Tightening
Torque
[lb-ft (Nm)]
B Service line (standard pressure range) SAE J518 1 in O
Fixing thread ISO 68 3/8-16 UNC-2B; 0.71 (18) deep 5100 (350) 29 (40)
S Intlet (standard pressure range) SAE J518 2 in O
Fixing thread ISO 68 1/2-13 UNC-2B; 0.87 (22) deep 75 (5) 66 (90)
L, L1 Case drain ISO 11926 7/8-14 UNF-2B 30 (2) 177 (240) O1)
X Pilot pressure ISO 11926 7/8-14 UNF-2B; 0.39 (10) deep 5100 (350) 29 (40) O
X Control pressure for DG control DIN 3852 R 1/4 in 1740 (120) 48 (70) O

1) Dependent on the installation position, port L or L1 must be connected


O = Must be connected

www.FluiDyneFP.com Variable Displacement Pump (A)A10V, Series 31 23


Mounting
30/44
Dimensions, Size 100, Series 31
Bosch Rexroth Corporation (A)A10V(S)O | RA 92701-A/12.09

Dimensions,
30/44 size
Bosch Rexroth 100
Corporation (A)A10V(S)O | RA 92701-A/12.09
Service Ports on Side & Rear; Non Through Drive
Without Considering Adjustment
Dimensions, size 100
Port plate 62
Port Plate 62/12 NOO

0.50 (12.7)Port plate 62


9.84 (250) V
0.24 (6) 6.89 (175)

(40) max. 4.33 (110)


06
X

(1
Flange SAE J744

7
4.1
0.50
127-2 (SAE C) (12.7) 9.84 (250)

3.94 (100)3.94 (100)


V
45°

1.57 (40)
0.24 (6) 6.89 (175)

3.74 (95) max. 4.33 (110)


4.9975 (Ø127h8 )

06
X

0.69 (17.5)

X
(1
Flange SAE J744

5.98 (152)

7
4.1
127-2 (SAE C)

3.94 (100)3.94 (100)


45°
4.9975 (Ø127h8 )

1.57(95)
0.69 (17.5)
DIA 5.0000

X
5.98 (152)

3.74
0.79 (20)
DIA 5.0000

L1 7.13 (181)
3.74 (95) 8.27 (210)
10.83 (275) 4.65 (118) 5.84 (148.4)
0.79 (20) 12.48 (317) 6.50 (165)
L1 Valve
Valvemounting
mounting for counter7.13 (181)
for counter
3.74 (95) clockwise rotation 8.27 (210)
10.83 (275) W clockwise rotation
4.65 (118) 5.84 (148.4)
12.48 (317) View View W
W
ViewVV View
6.50 (165)
Valve mounting for counter
clockwise rotation

3.50 (88.9)
W

3.50 (88.9)2.36 (60)


(66.7)
1.26 (32)
2.63
11/12N00 threads M14; 19 deep View V View W
B
S

2.36 (60)
(66.7)
1.26 (32)

1.25 (31.8) 2.00


2.63

(50.8)
B
11/12N00 threads M14; 19 deep
S
Port plate 61 View
1.25Z(31.8) 2.00
3.90 (99) (50.8)
2.63 (66.7)
1.25 (31.8)

0.50 (12.7)Port plate


6.89
61 (175) View Z Z
1.57 (40)max. 4.33 (110)

L View
1.26 (32) B
Flange SAEPort 0.24
J744Plate 61/11 NOO(6)
3.90 (99)
127-2 (SAE C)
2.63 (66.7)
(55)
2.16(31.8)
1.57 (40)

0.50 (12.7) 6.89 (175)


4.9975 (Ø127h8)

max. 4.33 (110)

L 1.26 (32) B
X

Flange SAE J744 0.24 (6)


2.16 (55)1.25

127-2 (SAE C) Z
2.16 (55) 2.16 (55)

X
4.9975 (Ø127h8)
DIA 5.0000

Z
X
2.00 (50.8)

0.79 (20) S
DIA 5.0000

L1 2.36 (60)
3.74 (95) 3.50
11.34 (288) (88.9)
12.87 (327)
2.00 (50.8)

0.79 (20) 2.36 (60) S


13.54
L1 (344)
3.74 (95) 3.50
11.34 (288) Valve mounting for counter
(88.9)
12.87 (327) clockwise rotation
13.54 (344)
Valve mounting for counter
Valve mounting
clockwise for counter
rotation
clockwise rotation

24 Variable Displacement Pump (A)A10V, Series 31 www.FluiDyneFP.com


RA 92701-A/12.09 | (A)A10V(S)O
RA 92701-A/12.09 | (A)A10V(S)O Bosch Rexroth Corporation
Bosch Rexroth Corporation31/44 31/44

Mounting Dimensions, Size 100, Series 31


Dimensions, sizesize
Dimensions, 100 100
Drive shafts
Drive shafts
Drive Shafts
S Splined shaft 1 1/2
S Splined in117T
shaft 1/212/24 12/241) DP
in 17TDP 1) K Parallel with key
K Parallel with key
K Parallel with key
SAESJ744
Splined shaft 1 1/2 in 17T 12/24 DP1)
- 38-4
SAE J744(C-C)
- 38-4 (C-C) ISO 3019-1 38-1 38-1
ISO 3019-1
SAE J744 - 38-4 (C-C)
1) ISO 3019-1 38-1

7/16-14UNC-2B

7/16-14UNC-2B
DIA1 1/2in

DIA1 1/2in

1.10 (28)1.10 (28)


1.72 (43.6)
1.72 (43.6)
2.13 (54)
2.13 (54)
2.44 (62.441.9) (6 1.9)

U Splined shaft 1 1/4


U Splined in 114T
shaft 1/412/24 12/241)DP 1)
in 14TDP W Splined shaft 1 1/4
W Splined in 114T
shaft 1/412/24 12/241)DP 1)
in 14TDP
W Splined shaft 1 1/4 in 14T 12/24 DP1) SAE
U Splined
SAE J744
SAE shaft
- 32-4 -132-4
J744(C) 1/4 in(C)14T 12/24 DP1) SAE SAEJ744
J744
SAE- 32-4
J744(C)
- 32-4 (C)
- 32-4 (C) 1)
J744 - 32-4 (C) 1)

5/16-18UNC-2B

5/16-18UNC-2B
5/16-18UNC-2B

5/16-18UNC-2B

DIA 1 1/4in

DIA 1 1/4in
DIA 1 1/4in

DIA 1 1/4in

0.75 (190.75
) (19 )
0.75 (190.75
) (19 ) usable spline
usablelength
spline length1.38 (35)
1.38 (35)
1.38 (35)
1.38 (35)
2.18 (55.4)
2.18 (55.4) 2.18 (55.4)
2.18 (55.4)

1) ANSI B92.1a-1976, 30° pressure angle, flat root side fit, flank centering, tolerance class 5
1) ANSI B92.1a-1976,
1) ANSI 30° pressure angle, flat rootflat
side fit, side
flankfit,
centering, tolerance class 5 class 5
B92.1a-1976, 30° pressure angle, root flank centering, tolerance

Shaft P, ISO Flange A


4040mmmmØ0 Shaft
Shaft

Ports Ports
Ports (A)A10V 100
Designation
Designation Port Port
Designation forfor
forPort Standard
Standard Size
Standard 2)Size
Size 2) Peak
Peakpress.
Peak press. State State
press. Max State
[psi
[psi(bar)]
[psi (bar)] 3)
(bar)] 3) Tightening

B B ServiceService
line (high
linepressure range) range)
(high pressure SAE J518 SAE J5181 1/4 in 1 1/4 in Torque
Fixing thread
Fixing thread ISO 68 ISO 681/2-13 UNC-2B; 0.75 (19)0.75
1/2-13 UNC-2B; deep(19) deep 5100 (350)
5100 (350)O [lb-ft
O (Nm)]
B Service line (high pressure range) SAE J518 1 1/4 in O
S S Intlet (standard
Intlet pressure
(standard range) range)
pressure SAE J518 SAE68 2 1/2 in2 1/2 in
J518 66 (90)
Fixing thread ISO 1/2-13 UNC-2B; 0.75 (19) deep 5100 (350)
Fixing thread
Fixing thread ISO 68 ISO 681/2-13 UNC-2B; 1.06 (17)1.06
1/2-13 UNC-2B; deep(17) deep 75 (5) 75 (5) O O
S Intlet (standard pressure range) SAE J518 2 1/2 in O
L Case drain ISO 11926 1 1/16-12 UNF-2B 30 (2) O 4) 4)
L Case
Fixing drain
thread ISO 68
ISO 11926 11/2-13
1/16-12UNC-2B;
UNF-2B 1.06 (17) deep 7530(5) (2) O 66 (90)
L 1L, L L 1 CaseCase
drain ISO 11926 1 1/16-12 UNF-2B 30 (2)3030(2) 4)
Case drain
drain ISO 11926
ISO 11926 111/16-12
1/16-12 UNF-2B
UNF-2B (2) plugged plugged
265 (360)
4)
O1)
1
X X Pilot pressure
Pilot pressure ISO 11926 7/16-20 7/16-20
ISO 11926 UNF-2B;UNF-2B;
0.39 (10)0.39
deep 5100 (350)
(10) deep O
5100 (350) O
X Pilot pressure ISO 11926 7/16-20 UNF-2B; 0.39 (10) deep 5100 (350) 59 (80) O
X X ControlControl
pressure for DG control
pressure DIN 3852
for DG control R 1/4 inR 1/4 in
DIN 3852 1740 (120) O
1740 (120) O
X Control pressure for DG control DIN 3852 R 1/4 in 1740 (120) 59 (80) O
2) For the max.
2) For tightening torquestorques
the instructions on pageon 44page
must44 bemust
observed.
the max. tightening the instructions be observed.
3) Application dependent thepressure spikesposition,
can occur.. Please consider this be
when selecting measuring equipment or fittings
3) Application
1) Dependent
4) Dependent
ondependent pressure
installation spikes canport
occur..
L or Please consider
L1 must this when selecting
connected measuring equipment or fittings
on
4) Dependentthe
O = Must be connected installation
on the position,
installation port L
position,or L
port1 must
L or L be
1
connected
must be connected
O = Must O= beMust
connected (plugged
be connected on delivery))
(plugged on delivery))
www.FluiDyneFP.com Variable Displacement Pump (A)A10V, Series 31 25
Mounting Dimensions, Size 140, Series 31

Service ports on side; Non through drive, Models 62N00 and 12N00 mech.
displacement
View W limiter max.

Flange SAE J744


152-4 (D) 12N00 M12;
17 deep

mech.
displacement
limiter min.

mech.
View V displacement
limiter min.

12N00 M14,
mech. displacement 19 deep
limiter

Shaft end mech.


displacement
K Parallel with key limiter max.
ISO 3019-1 44-1
S Splined shaft 1 3/4 in 13T 8/16 DP
SAE J744-44-4 (D)

Designation Port for Standard Size Peak Max


Pressure Tightening
[psi (bar] Torque
[lb-ft (Nm)]
B Pressure port (standard pressure range) SAE J518 1 1/4 in
Threading in bolt holes ISO 68 1/2-13 UNC-2B; 0.75 (24) deep 5100 (350) 66 (90)
S Inlet (standard pressure range) SAE J518 2 1/2 in
Threading in bolt holes ISO 68 1/2-13 UNC-2B; 0.94 (24) deep 75 (5) 66 (90)
L,L1 Case drain (L1 plugged) ISO 11926 1 1/16-12 UNF-2B 30 (2) 265 (360)
X Pilot pressure ISO 11926 9/16-18 UNF-2B; 0.51 (13) deep 5100 (350) 59 (80)
X Control pressure for DG control DIN 3852 M14 x 1.5; 0.47 (12) deep 1740 (120) 59 (80)

1) Dependent on the installation position, port L or L1 must be connected


O = Must be connected

26 Variable Displacement Pump (A)A10V, Series 31 www.FluiDyneFP.com


Through Drives
26/36 Bosch Rexroth AG | Industrial Hydraulics (A )A10VSO | RA 92 711/10.07

Through Drive Mounting Options


Through
Shaft Torque Data drives
Axial piston units A10V can be supplied with a through drive as shown in the ordering code on page 3. The type of through
drive is determined by codes (K40-K...). If the combination pump is not mounted in the factory, the simple type code is sufficient.
Included in this case are: shaft coupler, seals, and if necessary an adapter flange.
Maximum permissible input and through drive torque.

T tot T thr

The drive torques for pump 1 and pump 2 can be split up as required. However the max. permissible input torque T tot as well as
the max. permissible through drive torque Tthr may not be exceeded.

Max. perm. input torque T tot


18 28 45 71 100 140
With
U shaft U T tot lb.ft (Nm) 43 (59) - (-) 139 (188) - (-) 439 (595) - (-)
With shaft K T tot
lb.ft (Nm) 77 (104) 107 (145) 156 (212) 319 (433) 553 (750) 875 (1186)
With shaft S T tot
lb.ft (Nm) 92 (124) 146 (198) 235 (319) 462 (626) 814 (1104) 1195 (1620)
With shaft R T tot
lb.ft (Nm) 111 (150) 166 (225) 295 (400) 475 (644) - (-) - (-)
Max. perm. through drive torque T thr

W ith shaft K T thr lb.ft (Nm) 77 (104) 107 (145) 156 (212) 319 (433) 553 (750) 875 (1186)
W ith shaft S T thr lb.ft (Nm) 80 (108) 118 (160) 235 (319) 363 (492) 574 (778) 934 (1266)
W ith shaft R T thr lb.ft (Nm) 88 (120) 130 (176) 269 (365) 404 (548) - (-) - (-)
Keyed shaft T thr keyed lb.ft (Nm) 53 (72) 83 (112) 132 (179) 209 (283) 293 (398) 411 (557)
T tot = max. permissible input torque pump 1
T thr = max. permissible through drive torque
T thr keyed = max. permissible through drive torque at through drive to keyed shaft

Permissible
Permissibleoverhang moment
overhang moment
m1 , m2 , m3 weight of pump [lbs (kg)]
l1 , l 2 , l 3 distance to center of gravity [in (mm)]
1
T m = (m 1 • l 1 + m 2 • l 3 + m 3 • l 3 ) • [lb.ft]
12
1
... • [Nm]
102

S iz e 18 28 45 71 100 140
Permissible overhang moment Tm lb.ft (Nm) 369 (500) 649 (880) 1010 (1370) 1593 (2160) 2213 (3000) 3319 (4500)
at dyn. acceleration Tm lb.ft (Nm) 37 (50) 65 (88) 101 (137) 159 (216) 221 (300) 332 (450)
10g = 98.1 m/s 2

Weight m lbs (kg) 26,5 (12) 33 (15) 46 (21) 73 (33) 99 (45) 132 (60)
Distance to center of gravity l1 in (mm) 3.54 (90) 4.33 (110) 5.12 (130) 5.91 (150) 6.30 (160) 6.30 (160)

www.FluiDyneFP.com Variable Displacement Pump (A)A10V, Series 31 27


Through Drives
RA 92 711/10.07 | (A)A10VSO Industrial Hydraulics | Bosch Rexroth AG 27 /36

Through Drive
Overview Mountingdrive
of through Options
mounting options

K02

127-2 (C)

Dimensions of Through Drives


Dimensions of through drives
K01 Flange SAE J744 - 82-2 (A)
Hub for splined shaft to ANSI B.92.1a-1976 5/8 in 9T 16/32 DP 1)
(SAE J744 - 16-4 (A))
Size A 1
A3 A4
section A - B
18 7.16 (182) 0.57 (14,5) 1.65 (42)
28 8.03 (204) 0.63 (16) 1.85 (47)
45 9.02 (229) 0.63 (16) 2.09 (53)
71 10.51 (267) 0.79 (20) 2.40 (61)
100 13.31 (338) 0.79 (20) 2.56 (65)
140 13.78 (350) 0.63 (17) 3.03 (77)

thread
thread
to pump mounting
to pump flange
mounting flange metric
metric

K52 Flange SAE J744 - 82-2 (A)


28 Hub for
Variable splined shaft to
Displacement ANSI(A)A10V,
Pump B.92.1a-1976 3/431in 11T 16/32 DP
Series
1)
(SAE J744 - 19-4 (A-B)) www.FluiDyneFP.com
Size A 1
A2 A3 A4 A5
section A - B
18 7.16 1.57 0.74 1.69 M10; 0.57 (14,5) deep
100 13.31 (338) 0.79 (20) 2.56 (65)
140 13.78 (350) 0.63 (17) 3.03 (77)

Through Drives thread


to pump mounting flange metric

Dimensions of Through Drives


K52 Flange SAE J744 - 82-2 (A)
Hub for splined shaft to ANSI B.92.1a-1976 3/4 in 11T 16/32 DP 1)
(SAE J744 - 19-4 (A-B))
Size A 1
A2 A3 A4 A5
section A - B
18 7.16 1.57 0.74 1.69 M10; 0.57 (14,5) deep
45
°
(182) (40) (18,8) (43)
A A4
A3 28 8.03 1.53 0.74 1.85 M10; 0.63 (16) deep
(204) (39) (18,8) (47)
9 45 9.02 1.59 0.75 2.09 M10; 0.63 (16) deep
4.1

+0.020)
A 5 (ø82.55+0.050
DIA 6.5)

3.2520
DIA3.2508
(ø 1 0 (229) (40,5) (18,9) (53)
71 10.51 1.57 0.84 2.40 M10; 0.79 (20) deep
(267) (40) (21,3) (61)
0.39 (10) 100 13.31 1.57 0.75 2.56 M10; 0.79 (20) deep
B A5 A2
to pump mounting flange A1 thread (338) (40) (19) (65)
metric
140 13.78 1.61 0.75 3.03 M10; 0.67 (17) deep
(350) (41) (18,9) (77)

K02/K68 Flange SAE J744 - 101-2 (B)


Hub for splined shaft to ANSI B.92.1a-1976 7/8 in 13T 16/32 DP 1)
(SAE J744 - 22-4 (B))
Size A 1
A2 A3 A4 A5
section A - B
28 8.03 1.69 0.70 1.85 M12; 0.71 (18) deep
45
A ° A4 (204) (43) (17,8) (47)
omitted on A3
size 28 45 9.02 1.65 0.70 2.09 M12; 0.71 (18) deep
(229) (42) (17,9) (53)
)
46
(ø1 A5 71 10.51 1.69 0.80 2.40 M12; 0.79 (20) deep
)
+0.050
+0.020
DIA 4.0020
4.0008

(267) (43) (20,3) (61)


.7 5
(ø101.6

A5
DI 100 13.31 1.61 0.71 2.56 M12; 0.79 (20) deep
(338) (41) (18) (65)
A5

0.39 (10) 140 13.78 1.73 0.70 3.03 M12; 0.79 (20) deep
B A2
to pump mounting flange thread
(350) (44) (17,9) (77)
A1 metric
1)
pressure angle 30 °, flat root side fit, tolerance class 5

1)
(SAE J744 - 25-4 (B-B))
Size A 1
A2 A3 A4 A5
section A - B
45
45 9.02 1.87 0.73 2.09 M12; 0.71 (18) deep
A A4
A3 (229) (47,5) (18,4) (53)
71 10.51 1.87 0.82 2.40 M12; 0.79 (20) deep
5 (267) (47,5) (20,8) (61)
5.7
DIA 46)
100 13.31 1.87 0.72 2.56 M12; 0.79 (20) deep
+0,050
+0,020

(ø1
)
4.0020
DIA 4.0008
(ø101,6

(338) (47,5) (18,2) (65)


140 13.78 1.87 0.73 3.03 M12; 0.79 (20) deep
A5

(350) (47,5) (18,4) (77)


0.39 (10)
B A2
to pump mounting flange A1
thread
metric

www.FluiDyneFP.com Variable Displacement Pump (A)A10V, Series 31 29


K07 Flange SAE J744 - 127-2 (C)
Hub for splined shaft to ANSI B.92.1a-1976 1 1/4 in 14T 12/24 DP 1)
(SAE J744 - 32-4 (C))
5.
DIA 46)
100 13.31 1.87 0.72 2.56 M12; 0.79 (20) deep

+0,050
(ø101,6 +0,020
(ø1

)
4.0020
DIA 4.0008
(338) (47,5) (18,2) (65)
140 13.78 1.87 0.73 3.03 M12; 0.79 (20) deep
Through Drives

A5
(350) (47,5) (18,4) (77)
0.39 (10)
B A2
to pump mounting flange A1
thread
metric

Dimensions of Through Drives


K07 Flange SAE J744 - 127-2 (C)
Hub for splined shaft to ANSI B.92.1a-1976 1 1/4 in 14T 12/24 DP 1)
(SAE J744 - 32-4 (C))
Size A 1
A2 A3 A4 A5
section A - B
71 10.51 2.18 0.87 2.40 M16; 0.70 (18) deep
A5
A 45
thread
A4 (267) (55,5) (22) (61)
omitted on A3
metric 100 13.31 2.24 0.77 2.56 M16; 0.95 (24) deep
size 71
omitted on
(338) (57) (19,5) (65)
size 71
7.13
140 13.78 2.36 0.77 3.03 M16; 0.95 (24) deep

+0.050
+0.020
DIA )

)
5.0020
DIA 5.0008
1
(ø18
(350) (60) (19,4) (77)

(ø127
B 0.51 (13)
A2
to pump mounting flange A1

K24 Flange SAE J744 - 127-2 (C)


Hub for splined shaft to ANSI B.92.1a-1976 1 1/2 in 17T 12/24 DP 1)
(SAE J744 - 38-4 (C-C))
Size A 1
A3 A4
section A - B
100 13.31 (338) 0.95 (24) 2.56 (65)
140 13.78 (350) 0.95 (34) 3.03 (77)

thread
to pump mounting flange metric

1)
pressure angle 30 °, flat root side fit, tolerance class 5

Dimensions of through drives


K17 Flange SAE J744 - 152-4 (D)
Hub for splined shaft to ANSI B.92.1a-1976 1 3/4 in 13T 8/16 DP 1)
(SAE J744 - 44-4 (D))
Size A 1
A3 A4
section A - B
140 13.78 (350 approx. 0.83 (ca. 21) 3.03 (77)

thread
to pump mounting flange metric

30 Variable Displacement Pump (A)A10V, Series 31 www.FluiDyneFP.com


Pump Installation Notes
34/36 Bosch Rexroth AG | Industrial Hydraulics (A )A10VSO | RA 92 711/10.07

Installation
InstallationNotes
notes ρ =density [kg/m 3 ]
l = pipe lenth [m]
Optional installation position. The pump housing must be filled dv/dt = rate of change in fluid velocity[m/s 2 ]
with fluid during commissionig and operation. Δp2 : Pressure lodd due to static head
In order to attain the lowest noise level, all connections Δp2 = h . ρ . g . 10 –5 [bar]
(suction, pressure, pilot, case drain) must be linked by flexible h = head [m]
members to tank. ρ = density [kg/m 3 ]
g = gravity. = 9,81 m/s 2
Avoid placing a check valve in the case drain line.
Δp3 : line losses (elbows etc.)
The case drain hose corresponding to the size of the case
drain port should be installed at the highest case drain port Horizontal installation
location. The pump must be installaed in such a manner, that either “L“
Vertical installation (shaft end upwards) or “L1“ is at the top.
Following installation conditions must be taken into account:
Arrangement inside the reservoir
Arrangement inside the reservoir a) If the min. fluid level is above the top of the pump:
Before installation fill pump housing, keeping it in a horizontal Close “L 1 ” , "L" and “S” open, mount suction pipe to port S,
position. and pipe “L“ at least 200 mm away from suction pipe.
a) If the min. fluid level is equal to or above the pump mounting (see. fig. 3)
surface: b)If the min. fluid level is equal to or below the top of the pump:
Close port “L“, "L 1 " and “S” open; L 1 piped and also S with Pipe port "L" and "S" acc.to.fig. 4 , port "L 1 " closed.
suction pipe (see fig. 1). (compare limiting conditions)
b) If the min. fluid level is below the pump mounting surface: Note: In order to avoid damages to the pump, all attached
pipe port “L“ and “S“ acc. to fig. 2, close port “L“ (compare parts (e.g. protective caps, covers, etc.) must be removed
item limiting conditions) before installation.
Note: In order to avoid damages to the pump, all attached
Fluid
parts (e.g. protective caps, covers, etc.) must be removed min. 8 in (200mm)
before installation. L
Fluid

ht min
L S
L1 L1
min. 8 in (200mm) fig. 3
S
fig. 1 Arrangement outside the reservoir
Arrangement outside the reservoir Fill pump housing before commissioning.
B efore installation fill pump housing while keeping it in a Pipe port “S“ and the higher port “L“ or “L 1 “
horizontal position. For mounting above the tank see fig. 2. a) When mounting above the reservoir: see fig. 4 (compare
item limiting conditions)
Limiting condition:
b) Mounting below the reservoir: pipe ports “L“ and “S“
Min. pump inlet pressure p abs min = 12 psi (0,8 bar) under static
according to fig. 5, “L“ closed.
and dynamic loading.
Note: Avoid mounting above tank wherever possible in order to
attain a low noise level. L
S
The permissible suction height h is a result of the overall
pressure loss, but may not be greater than h max = 31.5 in (800
mm) (Immersion depth ht min = 8 in/200 mm). Fluid
ht min hmax

L1
L1 L
baffle
S fig. 4
ht min hmax

Fluid

Fluid
baffle fig. 2
ht min

Overall pressure loss baffle


ΔpGes = Δp1 + Δp2 + Δp3 ≤ (1 – p abs min) = 0,2 bar L1
Δp1 : Pressure loss inpipe due to accelerating column of fluid
S
ρ . l . dv . –5
Δp1 = 10 [bar]
dt L fig. 5
www.FluiDyneFP.com Variable Displacement Pump (A)A10V, Series 31 31
www.FluiDyneFP.com I sales@fluidynefp.com I 586-296-7200 42012