CONNECTION DESIGN FOR IPE600 (SHEAR)

Connection Geometry:

Conclusion: No Change in Approved Connection


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Design of Connection: Design Code : AISC ASD

Loads: Axial = 106 Tons (Tension)


Shear = 24 Tons (Vertical)

A325 Bolt Capacities: Fnt = 90 ksi 620.55 MPa


Fnv = 54 ksi 372.33 MPa
For M20 Bolts : Fnt = 9.75 Tons Fnv = 5.85 Tons

:: 14 No.s of M20 A325 Bolts Provided with 2 Angle Cleats of L150x100x10

:: Axial Tension load will be transfer as Double Shear from Web Bolts and then Tension
in Bolts Connecting to Member

Resultant Shear (Tension & Vertical Shear) for Web bolt group
= Sqrt(106^2 + 24^2) = 108.7 Tons

Double Shear Capacity of Bolt Group At Web


= 14 x 2 x 5.85 = 163.8 Tons
> Reasultant Shear "Hence Safe"

Bolt Group Tension Capacity at Connecting Member


= 14 x 9.75 = 136.5 Tons
> Axial Tension "Hence Safe"

Angle Cleat Capacity Check:


Net Area of Cleat = Gross Area - Bolt Hole Area
= 43 x 2 x 1 - 7 x 1 x 2.2 = 70.6 cm2

Net Stress in Angle Cleat = 106 / 70.6 = 1.50 Ton/cm2

< Capacity of A50 Cleat "Hence Safe"


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Conclusion: No Change in Approved Connection


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

CONNECTION DESIGN FOR IPE550 (SHEAR)

Connection Geometry:

Conclusion: No Change in Approved Connection


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Design of Connection: Design Code : AISC ASD

Loads: Axial = 65 Tons (Tension)


Shear = 12.5 Tons (Vertical)

A325 Bolt Capacities: Fnt = 90 ksi 620.55 MPa


Fnv = 54 ksi 372.33 MPa
For M20 Bolts : Fnt = 9.75 Tons Fnv = 5.85 Tons

:: 12 No.s of M20 A325 Bolts Provided with 2 Bend plates of L157x123x10

:: Axial Tension load will be transfer as Double Shear from Web Bolts and then Tension
in Bolts Connecting to Member

Resultant Shear (Tension & Vertical Shear) for Web bolt group
= Sqrt(65^2 + 12.5^2) = 66.2 Tons

Double Shear Capacity of Bolt Group At Web


= 12 x 2 x 5.85 = 140.4 Tons
> Reasultant Shear "Hence Safe"

Bolt Group Tension Capacity at Connecting Member


= 12 x 9.75 = 117.0 Tons
> Axial Tension "Hence Safe"

Angle Cleat Capacity Check:


Net Area of Cleat = Gross Area - Bolt Hole Area
= 37 x 2 x 1 - 6 x 1 x 2.2 = 60.8 cm2

Net Stress in Angle Cleat = 65 / 60.8 = 1.07 Ton/cm2

< Capacity of A50 Cleat "Hence Safe"


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Conclusion: No Change in Approved Connection


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

CONNECTION DESIGN FOR IPE450 (SHEAR)

Connection Geometry:

Conclusion: No Change in Approved Connection


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Design of Connection: Design Code : AISC ASD

Loads: Axial = 56 Tons (Tension)


Shear = 27 Tons (Vertical)

A325 Bolt Capacities: Fnt = 90 ksi 620.55 MPa


Fnv = 54 ksi 372.33 MPa
For M20 Bolts : Fnt = 9.75 Tons Fnv = 5.85 Tons

:: 12 No.s of M20 A325 Bolts Provided with 2 Angle Cleats of L150x100x10

:: Axial Tension load will be transfer as Double Shear from Web Bolts and then Tension
in Bolts Connecting to Member

Resultant Shear (Tension & Vertical Shear) for Web bolt group
= Sqrt(56^2 + 27^2) = 62.2 Tons

Double Shear Capacity of Bolt Group At Web


= 12 x 2 x 5.85 = 140.4 Tons
> Reasultant Shear "Hence Safe"

Bolt Group Tension Capacity at Connecting Member


= 12 x 9.75 = 117.0 Tons
> Axial Tension "Hence Safe"

Angle Cleat Capacity Check:


Net Area of Cleat = Gross Area - Bolt Hole Area
= 34.5 x 2 x 1 - 6 x 1 x 2.2 = 55.8 cm2

Net Stress in Angle Cleat = 56 / 55.8 = 1.00 Ton/cm2

< Capacity of A50 Cleat "Hence Safe"


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Conclusion: No Change in Approved Connection


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

CONNECTION DESIGN FOR IPE400 (SHEAR)

Connection Geometry:

Conclusion: Additional 4 M20 Bolts to Added in Cleat at Web


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Design of Connection: Design Code : AISC ASD

Loads: Axial = 55 Tons (Tension)


Shear = 9 Tons (Vertical)

A325 Bolt Capacities: Fnt = 90 ksi 620.55 MPa


Fnv = 54 ksi 372.33 MPa
For M20 Bolts : Fnt = 9.75 Tons Fnv = 5.85 Tons

:: 8 No.s of M20 A325 Bolts Provided with 2 Angle Cleats of L150x100x10

:: Axial Tension load will be transfer as Double Shear from Web Bolts and then Tension
in Bolts Connecting to Member

Resultant Shear (Tension & Vertical Shear) for Web bolt group
= Sqrt(55^2 + 9^2) = 55.7 Tons

Double Shear Capacity of Bolt Group At Web


= 8 x 2 x 5.85 = 93.6 Tons
> Reasultant Shear "Hence Safe"

Bolt Group Tension Capacity at Connecting Member


= 8 x 9.75 = 78.0 Tons
> Axial Tension "Hence Safe"

Angle Cleat Capacity Check:


Net Area of Cleat = Gross Area - Bolt Hole Area
= 28 x 2 x 1 - 4 x 1 x 2.2 = 47.2 cm2

Net Stress in Angle Cleat = 55 / 47.2 = 1.17 Ton/cm2

< Capacity of A50 Cleat "Hence Safe"


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Conclusion: Additional 4 M20 Bolts to Added in Cleat at Web


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

CONNECTION DESIGN FOR IPE360 (SHEAR)

Connection Geometry:

Conclusion: Additional 4 M20 Bolts to Added with Slot in Fin Plate


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Design of Connection: Design Code : AISC ASD

Loads: Axial = 60 Tons (Tension)


Shear = 9 Tons (Vertical)

A325 Bolt Capacities: Fnt = 90 ksi 620.55 MPa


Fnv = 54 ksi 372.33 MPa
For M20 Bolts : Fnt = 9.75 Tons Fnv = 5.85 Tons

:: 12 No.s of M20 A325 Bolts Provided with 1 Fin Plate of 200x12

:: Axial Tension load will be transfer as Single Shear from Web Bolts and then Tension
in Bolts Connecting to Member

Resultant Shear (Tension & Vertical Shear) for Web bolt group
= Sqrt(60^2 + 9^2) = 60.7 Tons

Single Shear Capacity of Bolt Group At Web


= 12 x 5.85 = 70.2 Tons
> Reasultant Shear "Hence Safe"

Fin Plate Welded to Connecting Member with 6mm Weld


Weld Capcity = 0.6x70x6.895 x 0.707x6 x 2x250 / 2 = 307.1 Tons
> Axial Tension "Hence Safe"

Angle Cleat Capacity Check:


Net Area of Cleat = Gross Area - Bolt Hole Area
= 25 x 2 x 1.2 - 4 x 1.2 x 2.2 = 49.44 cm2

Net Stress in Angle Cleat = 60 / 49.44 = 1.21 Ton/cm2

< Capacity of A50 Fin Plate "Hence Safe"


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Conclusion: Additional 4 M20 Bolts to Added with Slot in Fin Plate


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

CONNECTION DESIGN FOR IPE300 (SHEAR)

Connection Geometry:

Conclusion: Additional 3 M20 Bolts to Added in Fin Plate


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Design of Connection: Design Code : AISC ASD

Loads: Axial = 50 Tons (Tension)


Shear = 4.1 Tons (Vertical)

A325 Bolt Capacities: Fnt = 90 ksi 620.55 MPa


Fnv = 54 ksi 372.33 MPa
For M20 Bolts : Fnt = 9.75 Tons Fnv = 5.85 Tons

:: 9 No.s of M20 A325 Bolts Provided with 1 Fin Plate of 200x12

:: Axial Tension load will be transfer as Single Shear from Web Bolts and then Tension
in Bolts Connecting to Member

Resultant Shear (Tension & Vertical Shear) for Web bolt group
= Sqrt(50^2 + 4.1^2) = 50.2 Tons

Single Shear Capacity of Bolt Group At Web


= 9 x 5.85 = 52.7 Tons
> Reasultant Shear "Hence Safe"

Fin Plate Welded to Connecting Member with 6mm Weld


Weld Capcity = 0.6x70x6.895 x 0.707x6 x 2x190 / 2 = 233.4 Tons
> Axial Tension "Hence Safe"

Angle Cleat Capacity Check:


Net Area of Cleat = Gross Area - Bolt Hole Area
= 19 x 2 x 1.2 - 3 x 1.2 x 2.2 = 37.68 cm2

Net Stress in Angle Cleat = 50 / 37.68 = 1.33 Ton/cm2

< Capacity of A50 Fin Plate "Hence Safe"


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Conclusion: Additional 3 M20 Bolts to Added in Fin Plate


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

CONNECTION DESIGN FOR IPE270 (SHEAR)

Connection Geometry:

Conclusion: Additional 3 M20 Bolts to Added in Fin Plate


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Design of Connection: Design Code : AISC ASD

Loads: Axial = 40 Tons (Tension)


Shear = 7.5 Tons (Vertical)

A325 Bolt Capacities: Fnt = 90 ksi 620.55 MPa


Fnv = 54 ksi 372.33 MPa
For M20 Bolts : Fnt = 9.75 Tons Fnv = 5.85 Tons

:: 9 No.s of M20 A325 Bolts Provided with 1 Fin Plate of 200x12

:: Axial Tension load will be transfer as Single Shear from Web Bolts and then Tension
in Bolts Connecting to Member

Resultant Shear (Tension & Vertical Shear) for Web bolt group
= Sqrt(40^2 + 7.5^2) = 40.7 Tons

Single Shear Capacity of Bolt Group At Web


= 9 x 5.85 = 52.7 Tons
> Reasultant Shear "Hence Safe"

Fin Plate Welded to Connecting Member with 6mm Weld


Weld Capcity = 0.6x70x6.895 x 0.707x6 x 2x190 / 2 = 233.4 Tons
> Axial Tension "Hence Safe"

Angle Cleat Capacity Check:


Net Area of Cleat = Gross Area - Bolt Hole Area
= 19 x 2 x 1.2 - 3 x 1.2 x 2.2 = 35.28 cm2

Net Stress in Angle Cleat = 40 / 35.28 = 1.13 Ton/cm2

< Capacity of A50 Fin Plate "Hence Safe"


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Conclusion: Additional 3 M20 Bolts to Added in Fin Plate


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

CONNECTION DESIGN FOR IPE200 (SHEAR)

Connection Geometry:

Conclusion: Additional 2 M20 Bolts to Added in Fin Plate


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Design of Connection: Design Code : AISC ASD

Loads: Axial = 26 Tons (Tension)


Shear = 2.5 Tons (Vertical)

A325 Bolt Capacities: Fnt = 90 ksi 620.55 MPa


Fnv = 54 ksi 372.33 MPa
For M20 Bolts : Fnt = 9.75 Tons Fnv = 5.85 Tons

:: 6 No.s of M20 A325 Bolts Provided with 1 Fin Plate of 200x12

:: Axial Tension load will be transfer as Single Shear from Web Bolts and then Tension
in Bolts Connecting to Member

Resultant Shear (Tension & Vertical Shear) for Web bolt group
= Sqrt(26^2 + 2.5^2) = 26.1 Tons

Single Shear Capacity of Bolt Group At Web


= 6 x 5.85 = 35.1 Tons
> Reasultant Shear "Hence Safe"

Fin Plate Welded to Connecting Member with 6mm Weld


Weld Capcity = 0.6x70x6.895 x 0.707x6 x 2x130 / 2 = 159.7 Tons
> Axial Tension "Hence Safe"

Angle Cleat Capacity Check:


Net Area of Cleat = Gross Area - Bolt Hole Area
= 13 x 2 x 1.2 - 2 x 1.2 x 2.2 = 25.92 cm2

Net Stress in Angle Cleat = 26 / 25.92 = 1.00 Ton/cm2

< Capacity of A50 Fin Plate "Hence Safe"


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Conclusion: Additional 2 M20 Bolts to Added in Fin Plate


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

CONNECTION DESIGN FOR HEA700 (SHEAR)

Connection Geometry:

Conclusion: M24 - 3X6 Bolts at Web & 4X5 Bolts at Connecting Member
Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Design of Connection: Design Code : AISC ASD

Loads: Axial = 270 Tons (Tension)


Shear = 65 Tons (Vertical)

A325 Bolt Capacities: Fnt = 90 ksi 620.55 MPa


Fnv = 54 ksi 372.33 MPa
For M24 Bolts : Fnt = 15.97 Tons Fnv = 9.58 Tons

:: 18 & 20 No.s of M24 A325 Bolts Provided with 2 Bend plates of L250x200x16

:: Axial Tension load will be transfer as Double Shear from Web Bolts and then Tension
in Bolts Connecting to Member

Resultant Shear (Tension & Vertical Shear) for Web bolt group
= Sqrt(270^2 + 65^2) = 277.7 Tons

Double Shear Capacity of Bolt Group At Web


= 16 x 2 x 9.58 = 306.6 Tons
> Reasultant Shear "Hence Safe"

Bolt Group Tension Capacity at Connecting Member


= 20 x 15.97 = 319.4 Tons
> Axial Tension "Hence Safe"

Angle Cleat Capacity Check:


Net Area of Cleat = Gross Area - Bolt Hole Area
= 57 x 2 x 1.6 - 6 x 1.6 x 2.6 = 157.44 cm2

Net Stress in Angle Cleat = 270 / 157.44 = 1.71 Ton/cm2

< Capacity of A50 Cleat "Hence Safe"


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Conclusion: M24 - 3X6 Bolts at Web & 4X5 Bolts at Connecting Member
Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

CONNECTION DESIGN FOR HEA500 (SHEAR)

Connection Geometry:

Conclusion: No Change in Approved Connection


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Design of Connection: Design Code : AISC ASD

Loads: Axial = 95 Tons (Tension)


Shear = 30 Tons (Vertical)

A325 Bolt Capacities: Fnt = 90 ksi 620.55 MPa


Fnv = 54 ksi 372.33 MPa
For M20 Bolts : Fnt = 9.75 Tons Fnv = 5.85 Tons

:: 12 No.s of M20 A325 Bolts Provided with 2 Bend plates of L157x123x10

:: Axial Tension load will be transfer as Double Shear from Web Bolts and then Tension
in Bolts Connecting to Member

Resultant Shear (Tension & Vertical Shear) for Web bolt group
= Sqrt(95^2 + 30^2) = 99.6 Tons

Double Shear Capacity of Bolt Group At Web


= 12 x 2 x 5.85 = 140.4 Tons
> Reasultant Shear "Hence Safe"

Bolt Group Tension Capacity at Connecting Member


= 12 x 9.75 = 117.0 Tons
> Axial Tension "Hence Safe"

Angle Cleat Capacity Check:


Net Area of Cleat = Gross Area - Bolt Hole Area
= 37 x 2 x 1 - 6 x 1 x 2.2 = 60.8 cm2

Net Stress in Angle Cleat = 95 / 60.8 = 1.56 Ton/cm2

< Capacity of A50 Cleat "Hence Safe"


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Conclusion: No Change in Approved Connection


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

CONNECTION DESIGN FOR HEA400 (SHEAR)

Connection Geometry:

Conclusion: 10 No.s of M20 Bolts to be Provided instead of M16 Bolts


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Design of Connection: Design Code : AISC ASD

Loads: Axial = 81 Tons (Tension)


Shear = 10 Tons (Vertical)

A325 Bolt Capacities: Fnt = 90 ksi 620.55 MPa


Fnv = 54 ksi 372.33 MPa
For M20 Bolts : Fnt = 9.75 Tons Fnv = 5.85 Tons

:: 10 No.s of M20 A325 Bolts Provided with 2 Bend plates of L157x100x10

:: Axial Tension load will be transfer as Double Shear from Web Bolts and then Tension
in Bolts Connecting to Member

Resultant Shear (Tension & Vertical Shear) for Web bolt group
= Sqrt(81^2 + 10^2) = 81.6 Tons

Double Shear Capacity of Bolt Group At Web


= 10 x 2 x 5.85 = 117.0 Tons
> Reasultant Shear "Hence Safe"

Bolt Group Tension Capacity at Connecting Member


= 10 x 9.75 = 97.5 Tons
> Axial Tension "Hence Safe"

Angle Cleat Capacity Check:


Net Area of Cleat = Gross Area - Bolt Hole Area
= 29 x 2 x 1 - 5 x 1 x 1.8 = 49 cm2

Net Stress in Angle Cleat = 81 / 49 = 1.65 Ton/cm2

< Capacity of A50 Cleat "Hence Safe"


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Conclusion: 10 No.s of M20 Bolts to be Provided instead of M16 Bolts


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

CONNECTION DESIGN FOR HEA200 (SHEAR)

Connection Geometry:

Conclusion: Additional 2 M20 Bolts to Added in Fin Plate


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Design of Connection: Design Code : AISC ASD

Loads: Axial = 32 Tons (Tension)


Shear = 5 Tons (Vertical)

A325 Bolt Capacities: Fnt = 90 ksi 620.55 MPa


Fnv = 54 ksi 372.33 MPa
For M20 Bolts : Fnt = 9.75 Tons Fnv = 5.85 Tons

:: 6 No.s of M20 A325 Bolts Provided with 1 Fin Plate of 200x12

:: Axial Tension load will be transfer as Single Shear from Web Bolts and then Tension
in Bolts Connecting to Member

Resultant Shear (Tension & Vertical Shear) for Web bolt group
= Sqrt(32^2 + 5^2) = 32.4 Tons

Single Shear Capacity of Bolt Group At Web


= 6 x 5.85 = 35.1 Tons
> Reasultant Shear "Hence Safe"

Fin Plate Welded to Connecting Member with 6mm Weld


Weld Capcity = 0.6x70x6.895 x 0.707x8 x 2x130 / 2 = 212.9 Tons
> Axial Tension "Hence Safe"

Angle Cleat Capacity Check:


Net Area of Cleat = Gross Area - Bolt Hole Area
= 13 x 2 x 1.2 - 2 x 1.2 x 2.2 = 25.92 cm2

Net Stress in Angle Cleat = 32 / 25.92 = 1.23 Ton/cm2

< Capacity of A50 Cleat "Hence Safe"


Khalid Ali Kharafi Bros.Co.W.L.L. ‫م‬.‫م‬.‫شركة خالد على الخرافي و إخوانه ذ‬
General Contracting (K.S.C.C.) (‫م‬.‫ك‬.‫م‬.‫مقاولتا عامة و أعمال حديد )ش‬
Kharafi Steel ‫خرافي ستيل‬

Conclusion: Additional 2 M20 Bolts to Added in Fin Plate