Professional Documents
Culture Documents
Ecotechnics Katalog 2017 PDF
Ecotechnics Katalog 2017 PDF
2
3
Our services
The first A/C system and Ecotechnics’ patented Integrated system for A/C system leak testing by Collapsible, hermetic
passenger compartment air single-station solution for diagnosis of electro- charging with nitrogen from an cartridges offer full protection
purification system combined charging standard, hybrid and mechanical problems on A/C external tank (not included) and against ambient humidity for
with a charging station. 2 electric vehicles, with electric systems, featuring printout monitoring pressure drops, with oil and dye, to guarantee full
services in a single station! compressors. of diagnosis and problem leak alarm. product efficiency.
solutions.
4
5
The new A/C systems on motors containing a specific voltages are present. risk that residues of different system permits running this
many latest-generation high-performance electrical Preliminary flushing of the (non-insulating) oils may be flushing cycle automatically,
vehicles, such as hybrid or insulating oil. station and the service hoses injected into the A/C system, thanks to the specific lateral
electric vehicles, are equipped Use of other oils may prove is recommended before jeopardising its safety and couplings, integrated with the
with compressors operated dangerous for the operator servicing a system of this good operation. station, for connecting the
by high-voltage electric during system testing if high type. Flushing eliminates the The patented Ecotechnics service hoses.
7
The nitrogen leak testing testing may be conducted This system is fully integrated
system is an alternative to under pressure with an inert with the Ecotechnics
traditional leak detection gas. It is useful above all in recharging stations to
methods (testing during those cases in which use eliminate the need for operator
the vacuum phase or dye of a dye is not permissible intervention during service.
injection). The advantage (for example, in automobile The system prints a leak test
offered by nitrogen is that leak manufacturing). report at the end of testing.
9
Hermetic
PATENTED
Hermetic oil and dye cartridges
An A/C station equipped with (that is, substances that easily the station from possible
hermetic cartridges offers absorb humidity). damage from oils and/or
the advantage of eliminating The collapsible, accordion-type dyes of uncertain provenance.
contact between the humidity hermetic cartridges guarantee Moreover, many vehicle
naturally present in ambient the high quality of the manufacturers recommend
air and the oil or dye, which product charged and protect use of hermetic cartridges in
are hygroscopic substances the internal components of their authorised repair shops.
10
R134a HFO1234yf
ECK1800 ECK1800-HFO
ECK1890 ECK1890-HFO
Refrigerant Management
Each service is saved in
station memory, offering
✷ the option of creating a
customised archive of all
refrigerant transactions.
Automatic Leak Testing
The station checks for leaks
during the vacuum phase. If
leaks are found, it interrupts
operation and gives an alarm.
Automatic Dye Injection Thermal Printer USB port for software and
With refillable containers and
electronic scale.
For a complete, detailed
report.
Data Base✷
PATENTED
STANDARD FEATURES
OPTIONS
Flushing kit
For cleaning A/C systems by
flushing with refrigerant.
PATENTED
12
R134a HFO1234yf
ECK3500-up ECK3500-HFO
ECK3900-up ECK3900-HFO
5” Color Display with icon Automatic HP-LP taps Nitro Integrated Nitrogen Hybrid (patent pending) Hermetic
messaging for easy use. with possibility to select from and Nitrogen+Hydrogen leak Integrated function for service containers,
which port of the a/c system detection with a connection for hoses flushing for use with for new oil
to recover /charge external tank vehicles equipped with electric and dye.
compressors
STANDARD FEATURES
OPTIONS
Flushing kit Gas Identifier Saniflux Hermetic & refillable Diag (only for R134a)
For cleaning A/C systems by controlled by the machine. Passenger compartment air containers, for new oils, Dynamic diagnosis module.
flushing with refrigerant. purification system. and for dye (programmable).
3
16
IFIED
RT
Fully automatic station Eck 4000
CE
BY
®
TÜVRheinland
HFO1234yf
ECK4000-HFO
ECK4000
BY
TÜVRheinland
Eck 4000-hfo
17
Large 7” Color Display with 3 Hermetic & refillable Nitro Integrated Nitrogen Hybrid (patent pending) Gas Identifier
touch-screen icon messaging containers for new oils and Nitrogen+Hydrogen leak Flushing of station and
controlled by the machine
for easy use. (PAG,POE) and for dye. detection with a connection for service hoses for use with
(integrated) (ECK4000).
external tank vehicles equipped with electric
compressors.
STANDARD FEATURES
OPTIONS
Flushing kit Gas Identifier Saniflux
For cleaning A/C systems by controlled by the machine (external) Passenger compartment air
flushing with refrigerant. (ECK4000-HFO). purification system.
PATENTED PATENTED
18
Nitro Integrated Nitrogen Hybrid function, with service 4 separate lines for oil “Puff free” couplers
and Nitrogen+Hydrogen leak hoses flushing, for use with and dye with hermetic to save refrigerant with every
detection with a connection for vehicles equipped with electric containers disconnection
external tank compressors
PATENTED
STANDARD FEATURES
OPTIONS
Flushing kit Gas Identifier Saniflux 4 separate lines
For cleaning A/C systems by controlled by the machine Passenger compartment air for oil and dye with hermetic
flushing with refrigerant. purification system. and refillable containers
(programmable)
PATENTED PATENTED
20
NEW
Fully automatic station for Nitro Integrated Nitrogen
and Nitrogen+Hydrogen leak
recovering, recycling, and detection with a connection for
external tank
recharging R134a refrigerant, for use
with buses and industrial vehicles.
Automatic Leak Testing Automatic Discharge Gear Pump
The station checks for leaks (PATENT PENDING) for refrigerant charging.
during the vacuum phase. If of non-condensable gases
leaks are found, it interrupts via solenoid valves, with tank
operation and gives an alarm. temperature and pressure
sensors.
STANDARD FEATURES
Hermetic not
R134a AEK255-N-6 PAG 100 250 ml 6 pcs Mechanical
refillable
AEK 203- Box of 5 sealed bottles of tracer (55 ml)
C-5 (R134a)
UNIVERSAL
R134a - NEWAEK285-N-6 Hermetic not
POE 68 250 ml 6 pcs Mechanical-Electrical
HFO1234yf refillable
UNIVERSAL
(1000 ml)
R134a - Hermetic not
AEK270-N-6 - 125 ml 6 pcs Mechanical-Electrical
HFO1234yf refillable
R134a -
AEK276-6 Plastic bottle PAG 46 250 ml 6 pcs Mechanical-Electrical
HFO1234yf
R134a -
AEK275-6 Plastic bottle PAG 100 250 ml 6 pcs Mechanical-Electrical
HFO1234yf
UV COBRA LED LAMP, fluorescent
AEK145
enhanced goggles
R134a -
AEK290-6 Plastic bottle - 250 ml 6 pcs Mechanical-Electrical
HFO1234yf
Data Base
update DB.AGRI Data Base update for agricultural vehicles AEK218-A HP "puff free" coupler for HFO
AEK120-E Digital Thermometer
via USB ✷ AEK218-B LP "puff free" coupler for HFO
Data Base
Data Base update for car/commercial vehicles +
update DB.AUTOAGRI
agricultural vehicles
via USB ✷ CNT4012
40 L bottle for R134a, R22, R404a, R507,
R407C + AEK116-1
Adapter for refrigerant bottles for ACME
hoses
FLT8006 Filter for flushing kit AEK 102-N14 AEK318 Fitting for Dupont bottle
EASYREC PLUS
XK184.000049 AEK109A Terminal valve, high pressure
Refrigerant recovery machine
AEK211 Special quick-connect coupling AEK213 Nitrogen coupler for A/C machines
GRCNT19 Refillable and hermetic container (260 ml)
STUDIO Mirannalti
R134a HFO1234yf
ECK TWIN-PRO
ECK 1890-HFO
ECK 1800-HFO
ECK 3900-HFO
ECK 3500-HFO
ECK4000-HFO
ECK BUS-PRO
ECK 3900-UP
ECK 3500-UP
ECK LAND
ECK 1890
ECK 1800
ECK4000
HIGH PRECISION ● ● – – ● ● ● ●
AUTOMATIC LEAK CHECK ● ● ● – ● ● ● ●
REFRIGERANT ● ● ● ● ● ● ● ●
MANAGEMENT
DATA BASE ● ● ● ● ● ● ● ●
DISPLAY LCD COLOR 5” LCD LCD LCD COLOR 5” touch 7’’ touch 7’’
HERMETIC CONTAINERS – ● – – – ● ● –
REFILLABLE CONTAINERS ● – ● ● ● – – –
HERMETIC & REFILLABLE – ❍ – – – ❍ ❍ ●
CONTAINERS
OIL/DYE CONTAINERS 1+1 1+1 1+1 1+1 1+1 1+1 2+2 2+1
STATUS LIGHT – – – – – – – ●
AUTOMATIC TAPS – ● – – – ● ● ●
AUTOMATIC AIR PURGE – ● ● – – ● ● ● SNAP-ON CLIMATE SOLUTIONS S.R.L.
GEAR PUMP – – ● – – – – – a unico socio
FLUSHING SW ● ● – – ● ● ● ●
USB PORT ● ● ● ● ● ● ● ● Registered office address
GAS IDENTIFIER – ❍ – – – ❍ ❍ ❍/● Via Provinciale Carpi, 33
SANIFLUX – ❍ – – – ❍ ❍ ❍
42015 Correggio (RE)
HYBRID – ● – – – ● ● ●
NITRO – ● ● – – ● ● ●
Headquarters address
DIAG – ❍ – – – – – –
Via L. Longo, 21/23
PRINTER ● ● ● ● ● ● ● ●
50019 Sesto F.no (FI)
BOTTLE HEATER ● ● – ● ● ● ● ●
AUTOMATIC DYE ● ● ● – ● ● ● ●
Tel. +39 055 4207372
Fax +39 055 4217972
12/2016
FLUSHING KIT ❍ ❍ – – ❍ ❍ ❍ ❍
www.ecotechnics.com
● STANDARD EQUIPMENT – Not Available ❍ Optional
Information regarding dimensions, data, models, and colors is not binding. Ecotechnics reserves the right to make
email: sestofiorentino.info@snapon.com
any modifications deemed necessary. The products are not covered by any other express or implicit warranties.
Made
Images shown may include higher specification accessories. in Italy