I have this error while I am trying to do nozzle loading analysis with WRC
107:
Nozzle input window and the calculated maximum stress ratio is fine (i.e.
passed), but the error shown above comes out on the final report.
Cheers,
Han
Top
Dear Han
As a matter of the fact, ro means the outside radius of attachment such as
nozzle and Rm means the mean radius of cylindrical shell. As you know
WRC 107 has limitation for ro/Rm that when this value exceeds from
limitation, The error/warning message will appear. also you can not find
them on ASME code. for ratio other than WRC limitation , you can use
FEA method such as NOZZLE PRO. software. Also I can send you the
WRC 107 code but I donot know how i can attach this file to my reply.you
can leave the email address for me and I will send you the WRC standard
with Email.
Best Regards
V.Mahdavi