Professional Documents
Culture Documents
Ms 5800 Tube - en PDF
Ms 5800 Tube - en PDF
920-107
Multi-technology System
• Eddy Current
• Magnetic Flux Leakage
• Remote Field
• IRIS Ultrasound
MultiScan MS 5800 E
™
ECT Applications
a b c
Probes used to perform eddy current inspections are made with a copper
wire wound to form a coil. The coil shape can vary to better suit specific ap-
plications.
a- The alternative current flowing through the coil at a chosen frequency
generates a magnetic field around the coil.
b- When the coil is placed close to an electrically conductive material, eddy
current is induced in the material.
c- If a flaw in the conductive material disturbs the eddy current circulation,
the magnetic coupling with the probe is changed and a defect signal can
be read by measuring the coil impedance variation.
MultiScan MS 5800 R
™
. 3
Key Features
• RFT with up to four different frequencies and real-time mixes
This feature allows more flexibility for mixing and defect
validation. The detection and sizing of flaws at the support
plate becomes easier with multifrequency inspections and
dual-driver operations.
• RFT with frequencies ranging from 20 Hz to 250 kHz
The higher frequency available with the MS 5800R
extends the RFT inspection to thinner materials with lower
permeability, such as the stainless steel 400 series and other
ferromagnetic alloys.
• High-speed MFL inspection
The MFL technique is a good complement to RFT inspection.
R/D Tech high-saturation probes offer very good performance
®
MultiScan MS 5800 U
™
IRIS Applications
MultiView CARTO
™
™
Ultrasound Analysis Features • Database management of exchangers, reports, and tubesheet maps
• Graphical tools for the creation of tubesheet maps and inspec-
tion lists
• Storage of all reports and tubesheet maps in database
• Display results from single or multiple reports
Software Features (EC/RFT/MFL/UT)
Setup wizard Easy configuration for tube inspection
with conventional probes
Automatic calibration Simultaneous calibration of all chan-
nels and depth curves
Data file storage Any PC-compatible media
Printing Screen dump, acquisition and setup
reports to any Microsoft Windows
®
MultiView /T ™
Setup display A-scan
Profilometry display Wall thickness, ID and OD color C-
Tube Analysis Software Option scans, B-scan for tube circumferential
cross section, D-scan for tube axial
cross section
Cursors Cross-section cursors and pit-sizing
cursors
Measurement Wall loss (%), remaining wall, and
statistics on tube geometry
(minimum, maximum, average)
Software Requirements
Operating system Microsoft Windows NT , Windows
® ® ®
MultiScan MS 5800 Specifications
General Remote Field and Magnetic Flux Leakage
Power 120 VAC or 220 VAC ±10%, automatic Probe inputs 4 independent inputs for RFT
selection, 48 Hz to 63 Hz 4 independent inputs for MFL
Size (excluding handle) 45 cm x 30 cm x 22 cm RFT channels 16 simultaneously
(4 inputs x 4 frequencies)
Weight Maximum weight with all modules
installed: 12.8 kg MFL channels 4 simultaneously
64 in multiplexed mode
Environment –20°C to 45°C operating ambient,
(4 x 16 time slots)
–20°C to 70°C storage; 95% relative
humidity, noncondensing Number of frequencies Up to 4 frequencies
Computer interface 100Base-T Fast Ethernet ™
Frequency range Adjustable from 20 Hz to
250 kHz
Eddy Current
Acquisition rate 40 kHz per channel
Probe inputs 4 independent differential inputs and (in non-multiplexed mode)
up to 64 multiplexed inputs 14 kHz divided by the number of time
(16 time slots) slots (in multiplexed mode)
ECT channels 16 simultaneously Supported probes Supports any differential and absolute
(4 inputs x 4 frequencies) probes with single or dual exciters
256 in super-multiplexed mode (with (adapter cable may be required).
16 time slots)
Probe balancing True electronic probe balancing
Number of frequencies Up to 8 frequencies
Output voltage 20 V p-p per generator
Frequency range Adjustable from 20 Hz to 6 MHz
Output current 1 A (peak)
Acquisition rate 40 kHz per channel
(in non-multiplexed mode) Analog output X and Y components of the first input
14 kHz divided by the number of time
Real-time alarms 8 independent alarms
slots (in multiplexed mode)
Encoders 2 quadrature encoders or digital
Supported probes Universal connector supports all
inputs
standard differential and absolute
bobbin, impedance, transmit-receive, IRIS Ultrasound Testing
and rotating probes
(adapter cable may be required).
Number of pulsers/re- Multichannel UT (1, 4, or 8) working
ceivers in pulse-echo and transmit-receive
Probe balancing True electronic probe balancing. No modes
separate external reference probe is
required for absolute channels.
System bandwidth 0.5 MHz to 25 MHz
Output voltage 20 V p-p per generator Sampling rate 8-bit 100 MHz
Hardware Options
5800-E Eddy current capability
5800-R Remote field and magnetic flux leak-
age capability
5800-1U 1 internal UT channel
5800-4U 4 internal UT channels
5800-8U 8 internal UT channels
Olympus NDT
505, boul. du Parc-Technologique
Québec (Québec) G1P 4S9
Canada
MS5800_Tube_EN_0604 • Printed in Canada • Copyright © 2005–2006 by Olympus NDT. All Rights Reserved.
All specifications are subject to change without notice.
Olympus and the Olympus logo are registered trademarks of Olympus Corporation. rdtech@olympusndt.com
R/D Tech and the R/D Tech logo are registered trademarks, and "Innovation in NDT," MultiScan MS5800 and MultiView are trademarks of Olympus
NDT Corporation in Canada, the United States, and/or other countries. www.olympusNDT.com
Other company or product names mentioned in this document may be trademarks or registered trademarks of their respective owners.