Professional Documents
Culture Documents
Huawei PDF
Huawei PDF
Hardware Description
www.huawei.com
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page1
Contents
1. Product Introduction
2. Cabinet, Sub-rack
3. Boards
5. Features
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page2
Product Introduction
What is OSN 1500/2500/3500?
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page3
Network Application
4010G 160 10G Long-Haul
Back Bone
OptiX BWS 1600G OptiX BWS 1600G
iManager T2000
10G/2.5G 10G 10G/2.5G Core
OSN 3500 /7500/9500 OSN 7500/9500 OSN 3500/7500/9500
Convergence
OSN1500 /2500 OSN 2500/3500 OSN1500 /2500
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page4
System Architecture
STM-64
STM-1 LU LU (OSN3500)
Cross-connect Unit High-
STM-4/16 LU LU λ
order matrix
(VC-4)
Low-order matrix
(VC-12/VC-3)
PDH TU TU SAN/Video
Ethernet TU TU ATM
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page5
Large Capacity and Multi-services Access
Large and multi-
services access
capacity
STM-1/4/16/64 STM-1/4/16/64
VC-4-4c/8c/ SDH unit SDH unit VC-4-4c/8c
16c/64c /16c/64c
West
East
Cross-connect matrix
Large cross-connect
Multi-granularity
capacity
cross-connect
capacity
PDH Ethernet Other
Interface Interface Interface
unit unit unit
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page6
Contents
1. Product Introduction
2. Cabinet, Sub-rack
3. Boards
5. Features
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page7
Cabinet
ETSI 300/600 Cabinet
W(mm) D(mm) H(mm)
600 2000
600 2200
300 2600
2000 4 2 1
2200 4 3 2
2600 4 4 2
H
W D
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page8
Indicators
Indicator Color Status Description
On Cabinet is powered ON
Power Critical Major Minor Power
Off Cabinet is OFF
Power distribution Boards On Critical alarm
Critical alarm
Off No critical alarm
On Major alarm
Major alarm
Off No major alarm
On Minor alarm
Minor alarm
Off No minor alarm
Note:
Indicators do not flash
If alarm indicator is ON, alarm occurs on one or more sub-racks inside
the cabinet
Alarms occur on sub-racks, ALM cable should be properly connected
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page9
Power Distribution Unit
1 2 3 4 5 6
1 2 3
OUTPUT
4
A B 1 2 3
OUTPUT
4
ON ON
OFF OFF
INPUT
32A 32A 20A 20A 32A 32A 20A 20A
A: Supply for Left Power interface From Left, the 1st switch supplies the lower sub-rack
B: Supply for Right Power interface The 1st & 2nd switches are mainly for the OptiX OSN 7500/3500
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page10
Power Consumption
DC power supply
Power
200 280 400 600
Consumption (W)
Fuse Capacity (A) 10 10 15 20
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page11
OptiX OSN 1500A Sub-rack
PIU
Core Unit
Auxiliary Unit
FAN box
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page12
OptiX OSN 1500A Sub-rack (Cont.)
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page13
OptiX OSN 1500B Sub-rack
Core Unit
Auxiliary Unit
FAN box
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page14
OptiX OSN 1500B Sub-rack (Cont.)
SLOT 14
SLOT 18 PIU Slot Relation 12 14,15
SLOT 15
SLOT 16 13 16,17
SLOT 19 PIU
SLOT 17
SLOT 14
Slot Relation 7 15 SLOT 18 PIU
SLOT 15
(After split) SLOT 16
8 17 SLOT 19 PIU
SLOT 17
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page15
OptiX OSN 2500 Sub-rack
SEI (Auxiliary Boards)
Core Unit
SAP (Auxiliary Unit)
PIU
FAN Unit
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page16
OptiX OSN 2500 Sub-rack (Cont.)
Slot Relation 6 1, 2
S S S S S S S S S S
L L L L L L L L L L 7 3, 4
O O O O O O O O O O
S S S S T T T T T T T T T T S S S S
L L L L L L L L
5 6 7 8 9 10 11 12 13 14
OO O O OO O O 12 15, 16
T T T T T T T T
1 2 3 4 6 6 2 2 2 2 2 2 1 S 15 16 17 18
13 17, 18
2 2 . . . . . . . A
2 2 5 5 5 5 5 5 2 P
M M G G G G G G 5 S S S
L L L
G O O O S S S S S S S
T T T L L L L L L L
Fiber routing panel 19 20 21
SLOT 22 SLOT 23 SLOT 24 SLOT 25
O O O O O O O
S S S S 622 622 1.25 T T T T T T T S S S S
PIU FAN FAN PIU L L L L M M G L L L L
8 9 10 11 12 13 14
O O O O O O O O
T T T T S S S T T T T
Slot Relation 20 1 21 3 1 2 3 4 L L L 2 2 2 2 2 1 S 15 16 17 18
(After split) 6 2 7 4 O O O . . . . . . A
T T T 5 5 5 5 5 25 P
5 6 7 G G G G G G
622 622 1.25
M M G
12 15,16
Fiber routing panel
13 17,18 SLOT 22 SLOT 23 SLOT 24 SLOT 25
PIU FAN FAN PIU
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page17
OptiX OSN 3500 Sub-rack
Interface slot area
Auxiliary Unit
PIU
FAN boxes
SCC Unit
Cross-connect Unit
Air filter
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page18
OptiX OSN 3500 Sub-rack (Cont.)
S S S S S S S S S S S S S S S S S S S
Slot Relation L L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O O
T T T T T T T T T T T T T T T T T T T
1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
2 19, 20 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7
3 21, 22 P P A
I I U
4 23, 24 U U X
S S S S S S S S S S S S S S S S S S
L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
13 29, 30 T T T T T T T T T T T T T T T T T T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
16 35, 36
Fiber Routing
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page19
OptiX OSN 3500 Sub-rack (Cont.)
Configure 1
Access
FAN FAN FAN
capacity :35G
S S S S S S S S S S S S S S S S S S
622 M x 8 L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
2.5 G x 4 T T T T T T T T T T T T T T T T T T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
10 G x 2 6 6 6 6 6 2 2 10 G G 10 2 2 6 6 6
2 2 2 2 2 . . G X X G . . 2 2 2 S S
2 2 2 2 2 5 5 C C 5 5 2 2 2 C C
M M M M M G G S S G G M M M C C
Fiber Routing
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page20
OptiX OSN 3500 Sub-rack (Cont.)
Configure 2
Access
FAN FAN FAN
capacity :58.75G
S S S S S S S S S S S S S S S S S S
1.25 G x 7 L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
2.5 G x 4 T T T T T T T T T T T T T T T T T T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
10 Gx4 1 1 1 1 2 2 10 10 E E 10 10 2 2 1 1 1.
/ / 25
. . . . . . G G U U G G . . . . G S
2 2 2 2 5 5 X X 5 5 2 2 / C
5 5 5 5 G G C C G G 5 5 S C
G G G G S S G G C
C
Fiber Routing
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page21
OptiX OSN 3500 Sub-rack (Cont.)
Configure 3
Access
FAN FAN FAN
capacity :155G
S S S S S S S S S S S S S S S S S S
5 Gx 7 L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
10 G x 4 T T T T T T T T T T T T T T T T T T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
20 G x 4 5 5 5 5 10 10 20 20 S S 20 20 10 10 5 5 5G S
G G G G G G G G X X G G G G G G S/ C
C C C C
S S C
Fiber Routing
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page22
Questions
Please list the slot access capacity of the equipment.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page23
Contents
1. Product Introduction
2. Cabinet, Sub-rack
3. Boards
5. Features
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page24
Contents
3. Boards
3.1 SDH Unit
3.2 PDH Unit
3.3 Ethernet Unit
3.4 ATM Unit
3.5 MST Unit
3.6 WDM Unit
3.7 Cross-connect and System Control Unit
3.8 Auxiliary Unit
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page25
SDH Unit
Boards appearance type
Processing
Interface
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page26
SDH Unit (Cont.)
S L Q 16
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page27
SDH Unit (Cont.)
Board Description
Connector
Board Full name Module available
type
1 x STM-64 processing with optical Fixed wavelength output, I-64.2, S-64.2b, L-
SF64 64.2b, Le-64.2, Ls-64.2, V-64.2b (with BA, PA,
interface board (FEC) and DCU)
1 x STM-64 processing with optical Fixed wavelength output, I-64.2, S-64.2b, L-
SL64
interface board 64.2b, Le-64.2, Ls-64.2,V-64.2b
1 x STM-16 processing with optical Fixed wavelength output
SF16 Ve-16.2c, Ve-16.2d, and Ve-16.2f
interface board (FEC) LC
4 x STM-16 processing with optical
SLQ16 I-16, S-16.1, L-16.1, L-16.2
interface board
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page28
SDH Unit (Cont.)
SL64 SF64 SF16 SL16 SLQ16 SL16A
SFP Module
STAT S TAT
STAT STAT STAT ACT STAT
4 indicators ACT
PROG
SRV
ACT
PROG
SRV
ACT
PROG
SRV
ACT
PROG
SRV
P ROG
S RV
ACT
PROG
SRV
CL ASS1
L ASER
PRODUCT
LC Connector
OUT1 IN1
OUT2 IN2
OUT OUT OUT OUT OUT
OUT3 IN3
Electrostatic Discharge IN IN IN IN IN
OUT4 IN4
CLASS 1
SL64 SF64 SF16 SL16 SLQ4 SL16A LASER
PRODUCT
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page29
SDH Unit (Cont.)
Slot available
Slot available
Board
OSN OSN OSN 3500
Name OSN 2500
1500A 1500B 40G 80G 200G
SF64 - - -
8, 11 7, 8, 11, 12
SL64 - - -
SF16 7, 8, 6 ~ 8,
12, 13 11~13 5 ~ 8, 11 ~ 14
SL16(A) 11 ~ 13 11 ~ 13
SLQ16 - - - - - 1 ~ 8, 11 ~ 16
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page30
SDH Unit (Cont.)
Board Description
SLO1 8 x STM-1 processing with optical interface board I-1, S-1.1, L-1.1, L-1.2,
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page31
SDH Unit (Cont.)
SLD4 SL4 SLT1 SLQ1 SL1
SLQ4 SLO1
STAT STA T STAT
STAT STAT STAT ACT STAT
ACT ACT
ACT ACT ACT PROG ACT
PROG PR OG PROG PROG
PROG PROG SRV SR V
SRV SRV SRV
SRV SRV
CLASS1 CLASS1
CLASS1 CLASS1 LASER
LASER CLASS1
LASER LASER CLASS1 PRODUCT
PRODUCT LASER
PRODUCT PRODUCT LASER PRODUCT
PRODUCT
OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7 OUT8 IN8 OUT9 IN9 OUT10 IN10 OUT11 IN11 OUT12 IN12
OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7
OUT1 IN1 OUT OUT
OUT1 IN1
OUT1 IN1
IN IN
OUT2 IN2
OUT2 IN2
OUT2 IN2
OUT3 IN3
OUT3 IN3
OUT8 IN8
OUT4 IN4
OUT4 IN4
CLAS S 1
LAS E R
CLASS 1 P RODUCT
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page32
SDH Unit (Cont.)
Slot available
Board
OSN 3500
Name OSN 1500A OSN 1500B OSN 2500
40G 80G 200G
SLQ4 6 ~ 8, 11 5 ~ 8, 11 ~ 14
SLD4 ~ 13
SL4
5 ~ 8,
SLT1 12, 13 11~13
11 ~ 13 1 ~ 8, 11 1 ~ 8, 11 ~ 17
SLO1
~ 16
SLQ1
SL1
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page33
SDH Unit (Cont.)
Boards Description
Board Full name Connector type Signal processing
with electrical
2 x STM-1 processing with electrical
SEP1 SMB interface board
interface board
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page34
SDH Unit (Cont.)
SEP1
No need for interface board
SEP
Need interface board: EU08, OU08, EU04
SMB interfaces on the front panel are inhibited
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page35
SC Connector
SFP Module
PRODUCT
CLASS 1
LASER
TSB8
TSB8
Page36
OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7 OUT8 IN8
OU08
OU08
OUT1IN1 OUT2IN2 OUT3IN3OUT4IN4OUT5IN5 OUT6IN6OUT7IN7OUT8 IN8
OU08
OU08
EU08
OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7 OUT8 IN8
AOUT AIN BOUT BIN
SEP1
SEP1
PROG
STAT
SRV
ACT
SLH1
SLH1
PROG
STAT
SRV
ACT
M
B
C
S
n
o
o
e
c
r
t
SDH Unit (Cont.)
Slot available
Slot available
Board
OSN OSN OSN OSN 3500 OSN 7500
Name
1500A 1500B 2500 40G 80G 200G 240G 360G
5 ~ 8,
SEP1 12,13 11~13 1 ~ 6, 13 ~ 16 1 ~ 3, 17, 18
11 ~ 13
2 ~ 5,
SLH1 - - - -
13 ~ 16
2, 3, 17, 18
6 ~ 7,
SEP 12, 13 2 ~ 5, 13 ~ 16
12 ~ 13
OU08 19, 21,
- 23, 25, 19 ~ 26,
-
EU08 1 ~ 4, 29, 31, 29 ~ 36 19 ~ 22, 35 ~ 38
14, 16
15 ~ 18 33, 35
19, 21, 23, 25, 29, 31, 33,
EU04
35
TSB4
14 1,17 19,35 37,38
TSB8
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page37
SDH Unit (Cont.)
Boards Description
Connector
Board Full name Module available
type
2 x STM-4 processing with
R1SLD4
optical interface board
I-4, S-4.1, L-4.1, L-4.2, Ve-4.2
STM-4 processing with optical
R1SL4
interface board
LC
4 x STM-1 processing with
R1SLQ1
optical interface board
I-1, S-1.1, L-1.1, L-1.2, Ve-1.2
STM-1 processing with optical
R1SL1
interface board
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page38
SDH Unit (Cont.)
SFP Module
STAT
STAT STAT STAT
ACT ACT ACT ACT
PROG PROG PROG PROG
SRV SRV SRV SRV
OUT1 IN1 OUT2 IN2
OUT IN
R1SLD4 R1SL4 R1SLQ1 R1SL1
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page39
SDH Unit (Cont.)
Slot available
Slot available
Board
OSN OSN OSN 3500
Name OSN 2500
1500A 1500B 40G 80G 200G
1 ~ 3, 11 ~
R1SLD4 7, 21
13
R1SL4 2, 3, 6 ~ 9, -
12, 13 1 ~ 3, 6 ~ 9, 5 ~ 7,19 ~
R1SLQ1 11 ~ 13 21
R1SL1
“R1-” boards are used in the small slots in OptiX OSN 1500 or when slots are segmented in
OptiX OSN 1500/2500.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page40
SDH Unit (Cont.)
Indicator
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page41
SDH Unit (Cont.)
Slot available
Indicator Status Color Description
Upload of board software to FLASH or the FPGA
On, green upload is normal, or the board software
initialization is normal.
On for 100ms and off for Board software is being uploaded to FLASH or
PROG 100ms alternatively, green FPGA.
Board On for 300ms and off for Board software is initializing, and is in BIOS boot
Software 300ms alternatively, green stage.
Board software in FLASH or the FPGA
On, red configuration is lost, resulting in upload and
initialization failure.
Off No power supply.
On, green Service is normal and no service alarm occurs.
SRV On, red Critical or major alarm occurs to service.
Service
Alarm On, yellow Minor or remote alarm occurs to service.
Off No service configured or no power supply.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page42
SDH Unit (Cont.)
Functions of SL16
Collect Alarm and
performance
……
STM-16
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page43
SDH Unit (Cont.)
Features of SL16
Fixed wavelength output
services
Setting and querying of the REG working 1 Last six digits of BOM
2 Internal number
3 Board version
mode 4 Board name
5 Board characteristic number
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page44
SDH Unit (Cont.)
Optical port parameters of SL16
Optical interface type I-16 S-16.1 L-16.1 L-16.2 L-16.2Je V-16.2Je U-16.2Je
(Board characteristic #) (01) (02) (03) (04) (02) (BA) (03) (BA+PA) (04)
Receiver sensitivity (dBm) -18 -18 -27 -28 -28 -28 -34
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page45
SDH Unit (Cont.)
Common alarms of SDH unit
Alarm level Color Alarm name Alarm reason
Critical R_LOS Receiver can not receive STM-N signal normally.
MS_AIS Critical alarm e.g. R_LOS happens.
Critical alarm e.g. R_LOS happens.
AU_AIS Wrong service configuration
Major
Faulty SDH board
POWER_
Power module of the line board fails.
ABNORMAL
Opposite station receives the R_LOS, R_LOF or MS_AIS
signal
MS_RDI
Faulty receiver at the opposite node or transmitter at the local
node
Minor Opposite node receives such alarms as AU_AIS and AU_LOP.
HP_RDI Faulty receiver at the opposite node or transmitter at the local
node
LOOP_ALM Software inloop or outloop is being performed.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page46
SDH Unit (Cont.)
Common performance events of SDH unit
Performance name Performance meaning
RSBBE Regenerator section block of background error
MSBBE Multiplex section block of background error
MSFEBBE Multiplex section far end block of background error
HPBBE High-order path block of background error
HPFEBBE High-order path far end block of background error
RPLCUR Current value of input optical power
RPLMAX Maximum value of input optical power
RPLMIN Minimum value of input optical power
TPLCUR Current value of output optical power
TPLMAX Maximum value of output optical power
TPLMIN Minimum value of output optical power
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page47
PDH Unit
Board Name Description Interface board
SPQ4 Processes 4 x E4/STM-1 MU04
PD3 Processes 6 x E3/T3 D34S
PL3 Processes 3 x E3/T3 C34S
PL3A Processes 3 x E3/T3 -
PQM Processes 63 x E1/T1
D75S, D12S, D12B
PQ1 Processes 63 x E1
PD1 Processes 32 x E1/T1 L75S,L12S,D75S,D12S,D12B
PD1 and PL1 are used in the small slot in OptiX OSN 1500/2500.
L75S/L12S can be only used in OptiX OSN 1500A.
PD1 cooperates with L75S/L12S in OptiX OSN 1500A, and cooperates with D75S/D12S in
OptiX OSN 2500 or OptiX OSN 1500B.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page48
PDH Unit (Cont.)
Slot available
Slot available
Board
OSN OSN OSN OSN 3500
Name
1500A 1500B 2500 40G 80G 200G
SPQ4
6, 7, 12,
PD3 - 12, 13 2 ~ 5, 13 ~ 16
13
PL3
5 ~ 8, 1 ~ 8, 11 ~
PL3A 12, 13 11~13 1 ~ 8, 11 ~ 17
11 ~ 13 16
MU04
1, 3, 15,
D34S - 14, 16 19, 21, 23, 25, 29, 31, 33, 35
17
C34S
PL3A is a processing board with cables led out from the front panel. .
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page49
PDH Unit (Cont.)
SPQ4/MU04 SPQ4
STAT
ACT
MU04
PROG
SRV
SMB connector
Indicators
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page50
PDH Unit (Cont.)
PL3A D34S C34S
PD3 PL3
STAT
STAT STAT ACT
ACT ACT PROG
PROG PROG SRV
SRV SRV
SMB connector
Indicators
OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page51
PDH Unit (Cont.)
Slot available
Slot available
Board
OSN OSN OSN 3500
Name OSN 2500
1500A 1500B 40G 80G 200G
PQM
- 11 ~ 13 14 ~ 17 1 ~ 5, 13 ~ 16
PQ1
D75S
D12S - 14 ~ 17 1 ~ 4, 15 ~ 18 19 ~ 26, 29 ~ 36
D12B
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page52
PDH Unit (Cont.)
Slot available
Slot available
Board
OSN OSN OSN 3500
Name OSN 2500
1500A 1500B 40G 80G 200G
1 ~ 3, 6 ~ 5 ~ 7, 19 ~
PD1 2, 12
8, 11 ~ 13 21
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page53
PDH Unit (Cont.)
Indicators DB44
PQ1 D75S D12S D12B
PQM
STAT STAT
ACT ACT
PROG PROG
SRV SRV
1~8
1~8
1~8
2mmHM
9~16
9~16
9~16
PD1 PL1 L75S L12S
STAT STAT
17~24
17~24
17~24
ACT ACT
PROG PROG
SRV SRV
25~32
25~32
25~32
1-16
1-16
1-16
PQM D75S D12S D12B
PQ1
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page54
PDH Unit (Cont.)
Functions of PQ1
Collect Alarm and
performance
E1
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page55
PDH Unit (Cont.)
Features of PQ1
Interface Type: 75Ω or 120Ω
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page56
PDH Unit (Cont.)
Common alarms of PDH unit
Alarm level Color Alarm name Alarm reason
The interface board and the processing board are
ALM_SUBCARD_ABN
mismatched
T_ALOS No E1 service is accessed
Major
Critical alarm e.g. R-LOS happens
TU_AIS Wrong service configuration
Faulty PDH board
Opposite node receives such alarms as TU_AIS
LP_RDI
Minor and TU_LOP
LP_REI LPBBE happens on the opposite node
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page57
PDH Unit (Cont.)
Common performance of PDH unit
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page58
Ethernet Unit
E G T 2
Note:
If there is no port on the board, then the board must work with an interface board.
ETF8/EFF8 is the interface board. ETF8 accesses 8×FE twisted pair signal, and
EFF8 accesses 8×FE optical signal
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page59
Ethernet Unit
Boards Description
4 x GE with L2 switching
EGS4 1000BASE-SX/LX/ZX LC
processing with interface board
2 x GE with L2 switching
EGS2 1000BASE-SX/LX/ZX LC
processing with interface board
2 x GE transparent transmission
EGT2 1000BASE-SX/LX/ZX LC
processing with interface board
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page60
Ethernet Unit (Cont.)
EGS4 EGS2 EGT2 EMS4
STAT STAT
STAT STAT
ACT ACT
ACT ACT
PROG PROG
PROG PROG
SRV SRV SRV
SRV
LINK1 LINK1
ACT1 ACT1
LINK2 LINK2
ACT2 ACT2
CLASS 1 CLASS 1
LASER LASER
PRODUCT PRODUCT
CLASS 1
LASER
CLASS 1
LASER CLASS 1
PRODUCT PRODUCT
LASER
PRODUCT
OUT1 IN1
OUT1 IN1
OUT1 IN1
OUT1 IN1
OUT2 IN2
OUT2 IN2
OUT2 IN2
OUT2 IN2
OUT3 IN3
OUT3 IN3
On Link is established
OUT4 IN4
OUT4 IN4
LINK
LINK ACT LINK ACT Off Link is not established
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page61
Ethernet Unit (Cont.)
Board Full name EGR2 EMR0
STAT STAT
ACT
PROG
ACT
SRV PROG
LINK1 SRV
EGR2 2 x GE RPR processing with interface board ACT1
LINK2
LINK
ACT
ACT2
CLASS 1
CLASS 1
LASER
LASER
OUT1 IN1
OUT1 IN1
Function
OUT2 IN2
EVPL/EVPLAN Service FE1
QoS
FE2
SFP Module
Wrap and steering protection
FE PORT EGR2 EMR0
RJ 45 connector
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page62
Ethernet Unit (Cont.)
Slot available
Slot available
Board
OSN OSN OSN 3500
Name OSN 2500
1500A 1500B 40G 80G 200G
EGS4 -
EGS2 11 ~ 13 1 ~ 8, 11 ~ 16
12, 13 5 ~ 8, 11 ~
EGT2 13
1 ~ 4, 15
EMS4 - (11)12, 13 1 ~ 6, 13 ~ 16
~16
EGR2 6, 7, 12, 13 1 ~ 8, 11 ~ 16
12, 13 (11)12, 13 5 ~ 8, 11 ~
EMR0 1 ~ 6, 13 ~ 16
13
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page63
Ethernet Unit (Cont.)
Boards Description
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page64
Ethernet Unit (Cont.)
EFS4 EFS0 EFT8
STAT STAT
ACT STAT
ACT ACT
PROG PROG PROG
SRV SRV SRV
RJ 45 connector
FE1
FE2
FE1
FE3
FE4
FE2 EFT4
FE5 STAT
ACT
PROG
FE6 SRV
FE3 FE7
FE1
FE8
FE2
FE4
FE3
FE4
EFS4 EFS0 EFT8
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page65
Ethernet Unit (Cont.)
ETS8 EFF8 ETF8
1
FE PORT 2
3
4
RJ 45 5
6
7
8
Connector LINK ACT
OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7 OUT8 IN8
FE1
FE2
FE3
FE1
Board Name Interface Board
FE4
FE2
EFT8 ETF8,EFF8
FE3
FE5
EFS0 ETF8,EFF8,EFS8
FE4
FE6
FE7
EMS4
FE5 ETF8,EFF8
FE8
EMR0
FE6
CLASS 1
LASER
FE7
PRODUCT
FE8
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page66
Ethernet Unit (Cont.)
Boards Description
Slot available
Board
OSN OSN OSN 3500
Name OSN 2500
1500A 1500B 40G 80G 200G
5 ~ 8, 11 ~
EFS4 12, 13 11 ~ 13 1 ~ 8, 11 ~ 16 (17)
13
EFS0 6, 7, 12, 13 2 ~ 5, 13 ~ 16
7, 12, 13
- 12 ~ 13
EFT8 (5 ~ 8, 11 ~ 1 ~ 6, 13 ~ 16
13)
1 ~ 3,
2, 3, 6, 9, 5 ~ 7, 19 ~
EFT4 6 ~ 9, -
12, 13 21
12, 13
ETF8
ETS8 - 14 ~ 16 1, 3, 15, 17 19, 21, 23, 25, 29, 31, 33, 35
EFF8
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page67
Ethernet Unit (Cont.)
Function of EFS4
N×VC12/VC3
4 VC-12-Xv(x≤63), 8 X VC4
X VC-3-Xv(x≤12)
FE
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page68
Ethernet Unit (Cont.)
Features of EFS4
Supports bandwidth auto-sensing
Supports MPLS
Supports LCAS
Supports inloop at Ethernet port and inloop and outloop at VC3 level
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page69
Ethernet Unit (Cont.)
Common alarms of Ethernet unit
Minor LCAS_BAND_
VC-Trunk bandwidth decreases
DECREASED
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page70
Ethernet Unit (Cont.)
Common performance events of Ethernet unit
Performance name Performance meaning
DropOv Number of packet losses is over upper alarm threshold
DropUd Number of packet losses is under lower alarm threshold
RxBadOctOv Number of the bytes of bad packets received is over upper alarm threshold
RxBadOctUd Number of the bytes of bad packets received is under lower alarm threshold
TxBadOctOv Number of the bytes of bad packets transmitted is over upper alarm threshold
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page71
ATM Unit
Boards Description
Connector
Board Full name Interface type
type
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page72
ATM Unit (Cont.)
ADL4 ADQ1 IDL4 IDQ1
STAT STAT STAT STAT
ACT ACT ACT ACT
PROG PROG PROG PROG
SRV SRV SRV SRV
OUT1 IN1
OUT1 IN1
OUT1 IN1
OUT1 IN1
S
CLASS 1 F
OUT2 IN2
OUT2 IN2
LASER
PRODUCT
P
OUT3 IN3
C
OUT3 IN3
O
N
N
OUT4 IN4
OUT4 IN4
E
C
T
O
ADL4 ADQ1 IDL4 IDQ1
R
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page73
ATM Unit (Cont.)
Slot available
Slot available
Board
OSN OSN OSN 3500
Name OSN 2500
1500A 1500B 40G 80G 200G
ADL4
6 ~ 8, 11
1 ~ 8, 11 ~ 17
~ 13
ADQ1
(11), 12,
12, 13 7, 8, 11-13
13
IDL4
1 ~ 8, 11
1 ~ 8,11 ~ 17
~ 16
IDQ1
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page74
ATM Unit (Cont.)
Function of ADQ1
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page75
ATM Unit (Cont.)
Features of ADQ1
Supports CBR, rt-VBR, nrt-VBR and UBR
Supports QoS
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page76
ATM Unit (Cont.)
Common alarms of ATM unit
Alarm
Color Alarm name Alarm reason
level
Major VCRDI The VCAIS is reported on the opposite node ATM board
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page77
ATM Unit (Cont.)
Common performance of ATM unit
Performance name Performance meaning
VC3BBE VC3 block of background error
VC3ES VC3 errored second
VC3FEBBE VC3 far end block of background error
VC3FEES VC3 far end errored second
ATM_INGCELL Number of input cells in ATM link
ATM_EGCELL Number of output cells in ATM link
ATM_CORRECTED_HCSERR Number of corrected cells with HCS error at ATM interface
ATM_UNCORRECTED_HCSE
Number of uncorrected cells with HCS error at ATM interface
RR
ATM_RECV_CELL Number of cells ATM interface received
ATM_RECV_IDLECELL Number of idle cells ATM interface received
ATM_TRAN_CELL Number of cells ATM interface transmitted
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page78
MST Unit
Board description
Slot available
Slot available
Board
Name OSN OSN
OSN 2500 OSN 3500
1500A 1500B
5 ~ 8, 11 ~ 1 ~ 8, 11 ~
MST4 12, 13 11 ~ 13
13 16 (17)
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page79
MST Unit
Service Types
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page80
MST Unit (Cont.)
MST4
STAT
ACT
Features of MST unit
PROG
SRV
O
N
N
OUT4 IN4
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page81
MST Unit (Cont.)
Function
VC-4-4c/8c/16c X
VC4
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page82
Core Unit -OSN 1500/2500
The CXL1/CXL4/CXL16 is the core unit used in OptiX OSN 1500/2500.
Cross-connect Unit Timing Unit SCC Unit Line Unit
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page83
Cross-Connect Unit
SDH unit PDH unit Data unit
Collect Alarm
High-order cross-connect
matrix
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page84
Cross-Connect Unit –OSN1500/2500
CXL16 CXL4 CXL1
STAT STAT
ACTX
STAT
ACTX ACTX
ACTC ACTC
PROG ACTC
PROG
SRVX SRVX PROG
SRVL SRVL SRVX
SYNC SYNC SRVL
ALMC ALMC SYNC
ALMC
CLASS 1
CLASS 1
LASER CLASS 1
LASER
PRODUCT LASER
PRODUCT
PRODUCT
Indicator Color Description
OUT IN
RESET RESET
Board is powered off
RESET
Logical unit
GXCL (5G)
CXL16 CXL4 CXL1 EXCL (20G)
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page85
Cross-connect Unit –OSN3500
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page86
Cross-Connect Unit –OSN3500
OSN 3500
For Extension
Cross-connect Max access High-order cross- Low-order cross-
sub-rack HO XC
and timing board capacity connect capacity connect capacity
capacity
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page87
Cross-Connect and Timing Unit –
OSN3500
GXCSA EXCSA UXCSA UXCSB XCE SXCSA SXCSB
STAT STAT STAT STAT STAT STAT
ACT STAT
ACT ACT ACT ACT ACT ACT
PROG PROG PROG PROG PROG PROG
SRV PROG
SRV SRV SRV SRV SRV SRV
SYNC SYNC SYNC SYNC SYNC SYNC SYNC
EXB EXB
EXB
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page88
Cross-connect Unit –OSN3500
DB26 Connector:
UXCSB XCE
STAT
ACT
STAT
ACT
To connect the main
PROG PROG
SRV
SYNC
SRV
SYNC
sub-rack and the
extension sub-rack UXCSB/SXCSB
together.
EXA EXA
EXA EXA
EXB EXB
EXB EXB
EXA EXA
EXB EXB
UXCSB XCE
XCE
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page89
Cross-Connect Unit
Cross-
Standby
PDH unit connect PDH unit
Active
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page90
Cross-Connect Unit (Cont.)
Features
Support SNCP protection for VC-4-4C, VC-4-8C, VC-4-16C,
Active/standby Restoration
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page91
Timing Unit –OSN1500/2500
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page92
Timing Unit –OSN3500
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page93
Timing Unit
Features
Process traced clock signal from Line, Tributary and external clock
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page94
Cross-Connection & Timing Unit
Common alarms of Cross-Connect and Timing unit
Alarm level Color Alarm name Alarm reason
Chip of the cross-connect board is damaged
BUS_ERR
Damaged backplane bus
Major APS_INDI MSP switching happens
TEMP_OVER Ambient temperature is too high.
W_OFFLINE Ejector lever on the front panel is rotated to the open position.
EXT_SYNC_LOS Physical interface signal of the external clock source is lost.
Minor CLOCK_ENTER_NO
Clock working mode changes from locked into holdover or free-run.
_TRACE_MODE
Multiplex section protection switching fails.
APS_FAIL
MS node information is lost or set incorrectly
Warning
SWITCH_DISABLE Board switching is disabled
OTH_BD_STATUS Another board pulled out or plugged in
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page95
System Control & Communication Unit
SDH unit
Commands
PDH unit
Collect Alarm and
NMS
performance
Other unit
Other NE
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page96
System Control & Communication Unit –
OSN1500/2500
CXL1
Active SCC unit ACTC ( )
STAT
ACTX
ACTC
PROG
SRVX
SRVL
SYNC
ALMC
Standby SCC unit ACTC ( )
CLASS 1
LASER
PRODUCT
Reset board
To cut buzzer temporarily, press ALMC for 1 second ( )
RESET
To cut buzzer permanently, press ALMC for 3 seconds ( )
ALM CUT
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page97
System Control & Communication Unit –
OSN3500 (Cont.)
Indicator Color Description
SCC GSCC
STAT
STAT
ACT
PROG
ACT
PROG The –48 V power supply A is normal.
SRV
PWRA
PWRB
Reset SRV
PWRA
PWRB PWRA
PWRC PWRC
ALMC ALMC
The –48 V power supply A is faulty (lost or failed).
SCC GSCC
To re-enable buzzer, press ALMC for 1 second ( )
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page98
System Control & Communication Unit
(Cont.)
Functions
Service configuration, grooming and monitoring
Collects alarm and performance events
Supports NE ID setting by software
1+1 hot backup
Extended ECC
Controls cabinet indicators and fans
3 Housekeeping alarm inputs and 1 alarm outputs
Supports ASON intelligent function
OSN3500: Inserted in slot 18 (Active) and/or Slot 17 (Standby)
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page99
System Control & Communication Unit
(Cont.)
Extended ECC function
NMS
Ring A Ring B
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page100
System Control & Communication Unit
(Cont.)
Four databases on the SCC MDB
Issued data
Automatically saves the current
data in dynamic RAM.
If power fails, the data in MDB will
be lost.
MDB
DRDB
Automatically saves the Fail NE in installing
verify status
successfully verified data.
If power fails, the data in
Success
DRDB will be lost.
Boards in
FDB0, FDB1
DRDB running status
Manually or periodically
saves the data. Enduringly Save manually or
saves data and does not periodically every 30 mins
need battery.
FDB0
FDB1
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page101
System Control & Communication Unit
(Cont.)
Common alarms of SCC unit
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page102
Auxiliary Unit
Board Description
Board Function Remark
AUX Auxiliary Interface Board -
PIU Power Interface Board -
EOW Orderwire Board -
SAP System Auxiliary Process Only for OptiX OSN 2500
SEI System Extended Interface Only for OptiX OSN 2500
UPM Uninterruptible Power Modules External
AMU Auxiliary Monitoring Unit Only for OptiX OSN 1500
BA2 Booster Amplifier Board -
BPA Pre-amplifier Board -
COA Case-based Optical Amplifier External
DCU Dispersion Compensation Board Only for OptiX OSN 3500/7500
FAN/FANA Fan unit -
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page103
Auxiliary Unit –AUX&AMU (OSN 1500)
ETH: T2000 Interface
AUX
AUX
ETH COM CLK ALM OAM/F&f
The AUX board used in
OptiX OSN 1500 is inserted
COM: Commissioning Interface in slot 10.
CLK : 120 ohms external clock input/output interface
ALM: House-keeping alarm input/output interface
OAM/F&f: NM and management serial interface
PHONE: Orderwire Interface
AMU
PROG
STAT
OptiX OSN 1500 is inserted PHONE S1 S2 LAMP1 LAMP2
in slot 9.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page104
Auxiliary Unit -SAP&SEI (OSN 2500)
ALMO1/2: Alarm output SAP is the system auxiliary
Q1SAP
ALMI1/2: 8 x Environment alarm input processing board. It is inserted in STAT
PROG
F&f: LCT
PHONE: Orderwire
CLK1/2: 120 Ω Ext clock input/output 1/2
V1/2: NNI Audio/Signaling
ALMI1 ALMI2 S1 S2 S3 S4 V1 V2
ETH
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page105
Auxiliary Unit -AUX (OSN 3500)
The AUX board used in OptiX OSN 3500 provides system
auxiliary interfaces. It is inserted in slot 37.
NIAUX
NIAUX
CLK1/2: 120 Ω Ext clock input/output 1/2 ALMP1/2: Cabinet indicator output
ETH: T2000 ALM01/2: Alarm output
COM: Commissioning Phone: Orderwire
EXT: Extended sub-rack V1/2: NNI Audio/Signaling
REV: - OAM: X.25 OAM
F&f: LCT
F1: Co-directional data 64 Kbit/s
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page106
Auxiliary Unit -PIU
R1PIUA is applicable to the OptiX
P IUA
P IUA
POWER
CLK IN
POWER
R1PIU
R1PIU
PWR
Switch
NEG(-) RTN(+) CLK OUT
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page107
Auxiliary Unit -PIU
PIU NIPIU
PS1
Used in OSN 2500
Inserted in slot 22 and 25 PS2
Interface Description
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page108
Auxiliary Unit –PIU (Cont.)
Functions
Access power –38.4 V ~ –57.6 V DC or -48 V ~ -72 V
Lightning protection
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page109
Auxiliary Unit -EOW (OSN 1500)
The EOW board is the orderwire board used in OptiX OSN 1500, which is
inserted in slot 9 of the sub-rack.
The AMU/EOW or some SDH/PDH unit can be inserted in slot 9 of the sub-
rack. Insert different boards due to different demands.
EOW
PROG
STAT
PHONE S1 S2 S3 S4
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page110
Auxiliary Unit -UPM (OSN1500)
Functions of UPM
Convert AC 110/220V to DC -48V
Height 1U
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page111
Auxiliary Unit -UPM (OSN1500)
4
BAT
! CAUTION
BAT- DO NOT INVERT POLARITY
注意极性 防止反接
BAT+
48V+
48V-
LOAD1 LOAD2
5 6
RS232
1 2 3
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page112
Amplifier Unit -BA2&BPA&COA
Board Description Connector
Slot available
Board OSN OSN
OSN 2500 OSN 3500
1500A 1500B
COA External
BA2 5 ~ 8, 11 ~ 1 ~ 8, 11 ~
12, 13 11 ~ 13
BPA 13 16 (17)
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page113
Auxiliary Unit -BA2
Tx BA Rx
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page114
Auxiliary Unit -BA2 (Cont.)
BA2
STA T
ACT
PR OG
SR V
1/ 2 BA modules
LC connector
OUT1 IN1
Specifications
OUT2 IN2
+13 ~ +15 -
CLASS 1
LASER
PRODUCT +15 ~ +17 -
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page115
Auxiliary Unit -BA2 (Cont.)
Function
2 channel power amplification
Used on TX side
ALS function
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page116
Auxiliary Unit -BPA
Tx PA Rx
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page117
Auxiliary Unit -BPA (Cont.)
BPA
STA T
ACT
PR OG
SR V
Port 1:
BA module
LC connector
BOUT BIN
Specifications
CLASS 1
LASER
PRODUCT
BPA
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page118
Auxiliary Unit -BPA (Cont.)
Function
1-channel power amplification
1-channel pre-amplification
ALS function
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page119
Auxiliary Unit -COA
8 9 10
1 2 3 4 5 6 7 11
1. ID DIP switch 2. Running indicator 3. Alarm indicator 4. RS232-1
9. OUT output optical port 10. Power switch 11. –48 V power interface
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page120
Auxiliary Unit -COA (Cont.)
External installation
Types
61COA
Only one EDFA module
Can work as BA (+14 dBm or +17dBm), PA (with the receiver sensitivity of –38
dBm ) or LA
62COA
Raman amplifier with good noise performance
used in the RX (with the receiver sensitivity of –39 dBm)
Ultra long hop transmission for a single span (>170 km )
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page121
Amplifier Unit
Common alarms of Amplifier unit
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page122
Amplifier Unit
Common performance of Amplifier unit
Performance name Performance meaning
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page123
Auxiliary Unit -DCU
DC U
OUT1 IN1
OUT2 IN2
Slot available
1 ~ 8, 11 ~ 1-8, 11-18,
DCU - - -
17 26-31
DC U
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page124
Auxiliary Unit -DCU (Cont.)
Compensates
60km or 80km
Tx BA PA DCU Rx
Insertion loss ≤7 dB
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page125
Auxiliary Unit -FAN
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page126
Auxiliary Unit -FAN (Cont.)
Function
Support hot swapping
Faulty fan
Major FAN_FAIL
Fan is power off
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page127
Questions
Please list different boards in OptiX OSN 1500/2500/3500.
SDH Boards
PDH Boards
Ethernet Boards
ATM Boards
MST Boards
WDM Boards
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page128
Contents
1. Product Introduction
2. Cabinet, Sub-rack
3. Boards
5. Features
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page129
Contents
4. Common network elements
4.1 Terminal multiplexer (TM)
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page130
Terminal multiplexer
TM
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page131
Terminal multiplexer (Cont.)
TM functions
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page132
Terminal multiplexer (Cont.)
TM configuration
3 x E3s
Tributary unit Line PIU Slot 1 PIU Slot 11 L75S Slot 6
FAN
Slot 2 PD1 Slot 12 L75S Slot 7
unit
PL3A Slot 13 Slot 8
CXL16 Slot 4 EOW Slot 9
32 x E1s STM-16
Slot 20 CXL16 Slot 5 AUX Slot 10
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page134
Terminal multiplexer (Cont.)
TM configuration D D D P P C C S
7 7 3 Q D X X A
5 5 4 1 3 L L P
S S S 1 1
6 6
Tributary unit Line unit
63 x E1s STM-16
S S S S S S S S S S S S S S S S S S
4 x E3s l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page135
Terminal multiplexer (Cont.)
D D D D D A
3 7 7 7 7 U
TM configuration 4 5 5 5 5 X
S S S S S
P P
S S S S S S S S I I S S S S S S S S S
l l l l l l l l U U l l l l l l l l l
Tributary unit Line unit o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t
1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
126 x E1s STM-64 9 0 1 2 3 4 5 6 9 0 1 2 3 4 5 6 7
S S S S S S S S S S S S S S S S S S
l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 2 2 3 4 5 6 7 8
OptiX OSN 3500 Fiber Routing
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page136
Add and drop multiplexer
ADM High rate signals
SDH: STM-1/4/16/64
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page137
Add and drop multiplexer (Cont.)
ADM functions
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page138
Add and drop multiplexer (Cont.)
ADM configuration
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page140
Add and drop multiplexer (Cont.)
ADM configuration D D D P P C C S
7 7 3 Q D X X A
5 5 4 1 3 L L P
S S S 1 1
6 6
Tributary unit Line unit
63 x E1s STM-16
S S S S S S S S S S S S S S S S S S
4 x E3s l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page141
Add and drop multiplexer (Cont.)
D D D D D A
3 7 7 7 7 U
ADM configuration 4 5 5 5 5 X
S S S S S
P P
S S S S S S S S I I S S S S S S S S S
l l l l l l l l U U l l l l l l l l l
Tributary unit Line unit o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t
1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
126 x E1s STM-64 9 0 1 2 3 4 5 6 9 0 1 2 3 4 5 6 7
S S S S S S S S S S S S S S S S S S
l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
OptiX OSN 3500 Fiber Routing
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page142
Multi-add and drop multiplexer
MADM High rate signals
SDH: STM-1/4/16/64
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page143
Multi-add and drop multiplexer (Cont.)
MADM functions
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page144
Multi-add and drop multiplexer (Cont.)
MADM configuration
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page146
Multi-add and drop multiplexer (Cont.)
MADM configuration D D D P P S C C S
7 7 3 Q D L X X A
5 5 4 1 3 D L L P
S S S 4 1 1
6 6
Tributary unit Line unit
63 x E1s STM-16
S S S S S S S S S S S S S S S S S S
4 x E3s STM-4 l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page147
Multi-add and drop multiplexer (Cont.)
D D D D D A
3 7 7 7 7 U
MADM configuration 4 5 5 5 5 X
S S S S S
P P
S S S S S S S S I I S S S S S S S S S
l l l l l l l l U U l l l l l l l l l
Tributary unit Line unit o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t
1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
100 x E1s STM-64 9 0 1 2 3 4 5 6 9 0 1 2 3 4 5 6 7
S S S S S S S S S S S S S S S S S S
l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 2 2 3 4 5 6 7 8
OptiX OSN 3500 Fiber Routing
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page148
Regenerator
OptiX OSN 2500REG
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page149
Regenerator (Cont.)
OptiX OSN 2500REG functions
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page150
Regenerator (Cont.)
OptiX OSN 2500REG S S S C C S S S S
L F L R R L F L A
configuration 1
6
1
6
6
4
G G 6
4
1
6
1 P
6
CRG:
Timing signal S S S S S S S S S S S S S S S S S S
l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
System control & t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
communication
Fiber routing panel
SLOT 22 SLOT 23 SLOT 24 SLOT 25
PIU FAN FAN PIU
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page151
Regenerator (Cont.)
OptiX OSN 2500REG fiber connection
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page152
Regenerator (Cont.)
OptiX OSN 3500
High rate signals
SDH: STM-64, STM-16, STM-16 (FEC)
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page153
Regenerator
OptiX OSN 3500 functions as REG & ADM
Add and drop tributary signals
PDH signals: E1/T1, E3/T3, E4
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page154
Regenerator (Cont.)
D D D D D A
3 7 7 7 7 U
OptiX OSN 3500 4 5 5 5 5 X
S S S S S
P P
configuration as REG & S S S S S S S S I I S S S S S S S S S
l l l l l l l l U U l l l l l l l l l
ADM o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
9 0 1 2 3 4 5 6 9 0 1 2 3 4 5 6 7
Tributary unit Line unit FAN FAN FAN
P P P S S S G G S S S S G G
100 x E1s STM-64 D Q Q L F L X X L F L E S S
3 1 1 1 1 6 C C 6 1 1 P C C
6 x E3s STM-16 (FEC) 6 6 4 S S 4 6 6 1 C C
S S S S S S S S S S S S S S S S S S
2 x STM-1e STM-16 l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 2 2 3 4 5 6 7 8
OptiX OSN 3500 Fiber Routing
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page155
Regenerator (Cont.)
OptiX OSN 3500 fiber connection as REG & ADM
OSN OSN
3500 OUT IN IN OUT
3500
IN OUT OUT IN
OSN OSN
3500 OUT IN IN OUT 3500
PQ1
SL16 SL16 SL16 SL16
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page156
Common network elements summary
ADM ADM
MADM
STM-1
ADM ADM
TM
Low-rate signals
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page157
Contents
1. Product Introduction
2. Cabinet, Sub-rack
3. Boards
5. Features
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page158
Equipment Protection -OSN1500
Items protected Protection scheme
E1/T1 processing board 1:2 TPS
E3/DS3 processing board
E4/STM-1 processing board 1:1 TPS
FE Processing board
Core unit 1+1 hot backup protection
-48V power interface card 1+1 hot backup protection
3.3V card power supply 1:N centralized hot backup protection
* The OptiX OSN 1500 can support two TPS groups of different types of services at the one time.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page159
Equipment Protection –OSN2500
Items protected Protection scheme
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page160
Equipment Protection –OSN2500 (Cont.)
S S S S S S S S S S S S S S S S S S
L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
T
1
T
2
T
3
T
4
T
5
T
6
T
7
T
8
T
9
T
10
T
11
T
12
T
13
T
14
T
15
T
16
T
17
T
18
1:4 TPS of E1/T1 board
C C S
X X A
L L P
P W W W W
S S S S S S S S S S S S S S S S S S
L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
T T T T T T T T T T T T T T T T T T
2 groups 1:1 TPS for 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
E3/T3/E4/STM-1(e)/FE board T
S
C
X
C
X
S
A
T
S
B L L P B
P W W P
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page161
Equipment Protection –OSN3500
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page162
Equipment Protection –OSN3500 (Cont.)
1:8 TPS of E1/T1 board 3 groups of mixed TPS
S S S S S S S S S
S S S S S S S S S S S S S S S S S S S S S S S S S S S
1 1 1 1
L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L
3 4 5 6
O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O
T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T
E4 E4 E4 E4
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8 9 1 1 1 1 1
/1 /1 /1 /1
0 1 2 3 4 5 6 7 8 0 1 2 7 8
5 5 5 5
E3 Protection
E3 Working
E1 Working
E1 Working
E1 Protection
5 5 5 5
Working
Protection
Working
Working
Working
Working
Working
Working
Working
M M M M
S S S S
C C W WW P C C
C C C C
FE board1:1 TPS S
L
S S S
2 3 L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S S
L 1
S S S
1 L L
O O O O O O O O O O O O 5 6 O O
T T T T T T T T T T T T T T
1 4 5 6 7 8 9 1 1 1 1 1 1 1
F F 0 1 2 3 4 F F 7 8
E E E E
X X S S
C C C C
P W S S W P C C
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page163
Equipment Protection (Cont.)
Fans
The mutual backup of power supplies for the fans
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page164
Network Level Protections
Protections Types
1+1 MSP
Linear MSP
1:N (1 ≤ N ≤ 14) MSP
2-fiber bidirectional MSP ring
MSP ring 2-fiber unidirectional MSP ring
4-fiber bidirectional MSP ring
Mesh Protection Intelligent function
SNCP
Dual node interconnection (DNI)
Fiber-Shared Virtual Path Protection
MS-Shared Optical Path Protection
RPR
VP-Ring/VC-Ring Protection
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page165
Intelligent Features
Service level agreement (SLA)
Traffic engineering
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page166
Resilient Packet Ring (RPR)
Topology automatic discovery function
Fair algorithm
3 service levels
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page167
Summary
Product Introduction
Features
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page168
Thank you
www.huawei.com