You are on page 1of 170

OptiX OSN 1500/2500/3500

Hardware Description

www.huawei.com

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.


Objectives
 Upon completion of this course, you will be able to:
 Appreciate the networking applications of the OptiX OSN
1500/2500/3500

 Describe the system structure of the OptiX OSN 1500/2500/3500

 Outline the main boards of the OptiX OSN 1500/2500/3500

 Outline the system protection schemes of the OptiX OSN


1500/2500/3500

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page1
Contents
1. Product Introduction

2. Cabinet, Sub-rack

3. Boards

4. Common Network Elements and Configuration

5. Features

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page2
Product Introduction
What is OSN 1500/2500/3500?

 Full name: OptiX OSN 1500/2500/3500 intelligent optical switching


system

 Form the OptiX OSN NG-SDH Series

 OSN1500/2500: Optical convergence or access switching system

OSN3500: Optical convergence or core switching system

 OSN: Optical Switch Node

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page3
Network Application
4010G 160  10G Long-Haul
Back Bone
OptiX BWS 1600G OptiX BWS 1600G

iManager T2000
10G/2.5G 10G 10G/2.5G Core
OSN 3500 /7500/9500 OSN 7500/9500 OSN 3500/7500/9500

Convergence
OSN1500 /2500 OSN 2500/3500 OSN1500 /2500

OSN 2500/Metro OSN1500 /Metro OSN1500 /Metro Access

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page4
System Architecture
STM-64
STM-1 LU LU (OSN3500)
Cross-connect Unit High-
STM-4/16 LU LU λ
order matrix
(VC-4)
Low-order matrix
(VC-12/VC-3)
PDH TU TU SAN/Video

Ethernet TU TU ATM

Timing Unit Auxiliary Unit SCC


Management
External Unit
interface
synchronization
interface Auxiliary
interface

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page5
Large Capacity and Multi-services Access
Large and multi-
services access
capacity
STM-1/4/16/64 STM-1/4/16/64
VC-4-4c/8c/ SDH unit SDH unit VC-4-4c/8c
16c/64c /16c/64c
West
East

Cross-connect matrix

Large cross-connect
Multi-granularity
capacity
cross-connect
capacity
PDH Ethernet Other
Interface Interface Interface
unit unit unit

E1/T1/E3/T3/E4 FE/GE ATM/SAN/Video

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page6
Contents
1. Product Introduction

2. Cabinet, Sub-rack

3. Boards

4. Common Network Elements and Configuration

5. Features

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page7
Cabinet
ETSI 300/600 Cabinet
W(mm) D(mm) H(mm)

600 2000
600 2200
300 2600

Max. number of Sub-racks mounted


Height
(mm) OptiX OSN OptiX OSN OptiX OSN
1500 2500 3500

2000 4 2 1

2200 4 3 2

2600 4 4 2
H

W D

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page8
Indicators
Indicator Color Status Description

On Cabinet is powered ON
Power Critical Major Minor Power
Off Cabinet is OFF
Power distribution Boards On Critical alarm
Critical alarm
Off No critical alarm
On Major alarm
Major alarm
Off No major alarm
On Minor alarm
Minor alarm
Off No minor alarm

Note:
 Indicators do not flash
 If alarm indicator is ON, alarm occurs on one or more sub-racks inside

the cabinet
 Alarms occur on sub-racks, ALM cable should be properly connected

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page9
Power Distribution Unit
1 2 3 4 5 6

1 2 3
OUTPUT
4
A B 1 2 3
OUTPUT
4

ON ON

RTN1(+) RTN2(+) NEG1(-) NEG2(-)

OFF OFF
INPUT
32A 32A 20A 20A 32A 32A 20A 20A

1. Power socket (left) 2. Power cable RTN1(+) 3. Power cable RTN2(+)


4. Power cable NEG1(–) 5. Power cable NEG2(–) 6. Power socket (right)

A: Supply for Left Power interface From Left, the 1st switch supplies the lower sub-rack

B: Supply for Right Power interface The 1st & 2nd switches are mainly for the OptiX OSN 7500/3500

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page10
Power Consumption
 DC power supply

 Normal voltage: -48V or -60V


 Range of input voltage: -48V±20%(or -60V±20%)

OptiX OSN OptiX OSN OptiX OSN OptiX OSN


Equipment
1500A 1500B 2500 3500

Power
200 280 400 600
Consumption (W)
Fuse Capacity (A) 10 10 15 20

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page11
OptiX OSN 1500A Sub-rack

PIU

Service slot area

Core Unit

Auxiliary Unit
FAN box

Dimensions (mm) 133 (H) x 444 (W) x 262 (D)

Weight (kg) 8 (without boards and fans)

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page12
OptiX OSN 1500A Sub-rack (Cont.)

SLOT 1 SLOT 11 SLOT 6 1.25G


SLOT 2 2.5G SLOT 7 1.25G
SLOT 20
FAN
SLOT 3 2.5G SLOT 8 1.25G

SLOT 4 2.5G SLOT 9 1.25G

SLOT 5 2.5G SLOT 10

SLOT 1 SLOT 11 SLOT 6 1.25G


SLOT 2 1.25G SLOT 12 1.25G SLOT 7 1.25G
SLOT 20
FAN
SLOT 3 1.25G SLOT 13 1.25G SLOT 8 1.25G
SLOT 4 2.5G SLOT 9 1.25G
SLOT 5 2.5G SLOT 10

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page13
OptiX OSN 1500B Sub-rack

Interface slot area


PIU

Service slot area

Core Unit

Auxiliary Unit
FAN box

Dimensions (mm) 221 (H) x 444 (W) x 262 (D)

Weight (kg) 9 (without boards and fans)

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page14
OptiX OSN 1500B Sub-rack (Cont.)
SLOT 14
SLOT 18 PIU Slot Relation 12 14,15
SLOT 15
SLOT 16 13 16,17
SLOT 19 PIU
SLOT 17

SLOT 11 2.5G SLOT 6 622M


7 15
SLOT 1 2 2.5G SLOT 7 622M
8 17
SLOT 20
FAN
SLOT 1 3 2.5G SLOT 8 622M
SLOT 4 2.5G SLOT 9 622M
SLOT 5 2.5G SLOT 10

SLOT 14
Slot Relation 7 15 SLOT 18 PIU
SLOT 15
(After split) SLOT 16
8 17 SLOT 19 PIU
SLOT 17

SLOT 1 1.25G SLOT 11 1.25G SLOT 6 622M


SLOT 2 1.25G SLOT 12 1.25G SLOT 7 622M
2 14 12 15 SLOT 20
SLOT 3 1.25G SLOT 13 1.25G SLOT 8 622M
FAN
3 16 13 17 SLOT 4 2.5G SLOT 9 622M
SLOT 5 2.5G SLOT 10

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page15
OptiX OSN 2500 Sub-rack
SEI (Auxiliary Boards)

Service slot area

Interface slot area

Core Unit
SAP (Auxiliary Unit)

PIU

FAN Unit

Dimensions (mm) 447 (W) x 295 (D) x 472 (H)

Weight (kg) 17 (without boards and fans)

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page16
OptiX OSN 2500 Sub-rack (Cont.)
Slot Relation 6 1, 2
S S S S S S S S S S
L L L L L L L L L L 7 3, 4
O O O O O O O O O O
S S S S T T T T T T T T T T S S S S
L L L L L L L L
5 6 7 8 9 10 11 12 13 14
OO O O OO O O 12 15, 16
T T T T T T T T
1 2 3 4 6 6 2 2 2 2 2 2 1 S 15 16 17 18
13 17, 18
2 2 . . . . . . . A
2 2 5 5 5 5 5 5 2 P
M M G G G G G G 5 S S S
L L L
G O O O S S S S S S S
T T T L L L L L L L
Fiber routing panel 19 20 21
SLOT 22 SLOT 23 SLOT 24 SLOT 25
O O O O O O O
S S S S 622 622 1.25 T T T T T T T S S S S
PIU FAN FAN PIU L L L L M M G L L L L
8 9 10 11 12 13 14
O O O O O O O O
T T T T S S S T T T T
Slot Relation 20 1 21 3 1 2 3 4 L L L 2 2 2 2 2 1 S 15 16 17 18
(After split) 6 2 7 4 O O O . . . . . . A
T T T 5 5 5 5 5 25 P
5 6 7 G G G G G G
622 622 1.25
M M G
12 15,16
Fiber routing panel
13 17,18 SLOT 22 SLOT 23 SLOT 24 SLOT 25
PIU FAN FAN PIU

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page17
OptiX OSN 3500 Sub-rack
Interface slot area

Auxiliary Unit
PIU

FAN boxes

Service slot area

SCC Unit
Cross-connect Unit
Air filter

Dimensions (mm) 497 (W) x 295 (D) x 722 (H)

Weight (kg) 20 (without boards and fans)

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page18
OptiX OSN 3500 Sub-rack (Cont.)
S S S S S S S S S S S S S S S S S S S
 Slot Relation L L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O O
T T T T T T T T T T T T T T T T T T T
1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
2 19, 20 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7

3 21, 22 P P A
I I U
4 23, 24 U U X

5 25, 26 FAN FAN FAN

S S S S S S S S S S S S S S S S S S
L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
13 29, 30 T T T T T T T T T T T T T T T T T T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

14 31, 32 XCS XCS S S


C C
15 33, 34 C C

16 35, 36
Fiber Routing

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page19
OptiX OSN 3500 Sub-rack (Cont.)
 Configure 1
 Access
FAN FAN FAN
capacity :35G
S S S S S S S S S S S S S S S S S S
 622 M x 8 L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
 2.5 G x 4 T T T T T T T T T T T T T T T T T T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

 10 G x 2 6 6 6 6 6 2 2 10 G G 10 2 2 6 6 6
2 2 2 2 2 . . G X X G . . 2 2 2 S S
2 2 2 2 2 5 5 C C 5 5 2 2 2 C C
M M M M M G G S S G G M M M C C

Fiber Routing

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page20
OptiX OSN 3500 Sub-rack (Cont.)
 Configure 2
 Access
FAN FAN FAN
capacity :58.75G
S S S S S S S S S S S S S S S S S S
 1.25 G x 7 L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
 2.5 G x 4 T T T T T T T T T T T T T T T T T T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

 10 Gx4 1 1 1 1 2 2 10 10 E E 10 10 2 2 1 1 1.
/ / 25
. . . . . . G G U U G G . . . . G S
2 2 2 2 5 5 X X 5 5 2 2 / C
5 5 5 5 G G C C G G 5 5 S C
G G G G S S G G C
C

Fiber Routing

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page21
OptiX OSN 3500 Sub-rack (Cont.)
 Configure 3
 Access
FAN FAN FAN
capacity :155G
S S S S S S S S S S S S S S S S S S
 5 Gx 7 L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
 10 G x 4 T T T T T T T T T T T T T T T T T T
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

 20 G x 4 5 5 5 5 10 10 20 20 S S 20 20 10 10 5 5 5G S
G G G G G G G G X X G G G G G G S/ C
C C C C
S S C

Fiber Routing

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page22
Questions
 Please list the slot access capacity of the equipment.

 Do you remember the relation between the processing board slot


and the interface board slot in different equipment?

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page23
Contents
1. Product Introduction

2. Cabinet, Sub-rack

3. Boards

4. Common Network Elements and Configuration

5. Features

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page24
Contents
3. Boards
3.1 SDH Unit
3.2 PDH Unit
3.3 Ethernet Unit
3.4 ATM Unit
3.5 MST Unit
3.6 WDM Unit
3.7 Cross-connect and System Control Unit
3.8 Auxiliary Unit

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page25
SDH Unit
 Boards appearance type

 Processing with Interface

 Processing

 Interface

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page26
SDH Unit (Cont.)

SDH Line Unit

S L Q 16

- : 1*STM-N signal Digital rate:


D: 2*STM-N signals  64:STM-64
Q: 4*STM-N signals  16:STM-16
O: 8*STM-N signals  4:STM-4
T: 12*STM-N signals  1:STM-1
H: 16*STM-N signals

Can you tell the main function of SL64?

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page27
SDH Unit (Cont.)
 Board Description
Connector
Board Full name Module available
type
1 x STM-64 processing with optical Fixed wavelength output, I-64.2, S-64.2b, L-
SF64 64.2b, Le-64.2, Ls-64.2, V-64.2b (with BA, PA,
interface board (FEC) and DCU)
1 x STM-64 processing with optical Fixed wavelength output, I-64.2, S-64.2b, L-
SL64
interface board 64.2b, Le-64.2, Ls-64.2,V-64.2b
1 x STM-16 processing with optical Fixed wavelength output
SF16 Ve-16.2c, Ve-16.2d, and Ve-16.2f
interface board (FEC) LC
4 x STM-16 processing with optical
SLQ16 I-16, S-16.1, L-16.1, L-16.2
interface board

Fixed wavelength output, I-16, S-16.1, L-16.1,


1 x STM-16 processing with optical
SL16 (A) L-16.2, L-16.2Je, V-16.2Je (with BA), and U-
interface board
16.2Je (with BA and PA)

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page28
SDH Unit (Cont.)
SL64 SF64 SF16 SL16 SLQ16 SL16A
SFP Module
STAT S TAT
STAT STAT STAT ACT STAT

4 indicators ACT
PROG
SRV
ACT
PROG
SRV
ACT
PROG
SRV
ACT
PROG
SRV
P ROG
S RV
ACT
PROG
SRV
CL ASS1

L ASER
PRODUCT

CLASS 1 CLASS 1 CLASS 1 CLASS 1


CLASS 1
LASER LASER LASER LASER
LASER
PRODUCT PRODUCT PRODUCT PRODUCT
PRODUCT

LC Connector

OUT1 IN1
OUT2 IN2
OUT OUT OUT OUT OUT

OUT3 IN3
Electrostatic Discharge IN IN IN IN IN

OUT4 IN4
CLASS 1
SL64 SF64 SF16 SL16 SLQ4 SL16A LASER
PRODUCT

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page29
SDH Unit (Cont.)
 Slot available

Slot available
Board
OSN OSN OSN 3500
Name OSN 2500
1500A 1500B 40G 80G 200G

SF64 - - -
8, 11 7, 8, 11, 12
SL64 - - -

SF16 7, 8, 6 ~ 8,
12, 13 11~13 5 ~ 8, 11 ~ 14
SL16(A) 11 ~ 13 11 ~ 13
SLQ16 - - - - - 1 ~ 8, 11 ~ 16

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page30
SDH Unit (Cont.)
 Board Description

Board Full name Module available Connector type

SLQ4 4 x STM-4 processing with optical interface board


I-4, S-4.1, L-4.1, L-4.2,
SLD4 2 x STM-4 processing with optical interface board
Ve-4.2
SL4 1 x STM-4 processing with optical interface board

SLT1 12 x STM-1 processing with optical interface board LC

SLO1 8 x STM-1 processing with optical interface board I-1, S-1.1, L-1.1, L-1.2,

SLQ1 4 x STM-1 processing with optical interface board Ve-1.2

SL1 1 x STM-1 processing with optical interface board

 Signal processing with optical interface board

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page31
SDH Unit (Cont.)
SLD4 SL4 SLT1 SLQ1 SL1
SLQ4 SLO1
STAT STA T STAT
STAT STAT STAT ACT STAT
ACT ACT
ACT ACT ACT PROG ACT
PROG PR OG PROG PROG
PROG PROG SRV SR V
SRV SRV SRV
SRV SRV
CLASS1 CLASS1
CLASS1 CLASS1 LASER
LASER CLASS1
LASER LASER CLASS1 PRODUCT
PRODUCT LASER
PRODUCT PRODUCT LASER PRODUCT
PRODUCT

OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7 OUT8 IN8 OUT9 IN9 OUT10 IN10 OUT11 IN11 OUT12 IN12

OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7
OUT1 IN1 OUT OUT

OUT1 IN1
OUT1 IN1

IN IN
OUT2 IN2

OUT2 IN2
OUT2 IN2

OUT3 IN3
OUT3 IN3

OUT8 IN8

OUT4 IN4
OUT4 IN4

CLAS S 1
LAS E R

CLASS 1 P RODUCT

LASER SLQ4 SLD4 SL4 SLT1 SLO1 SLQ1 SL1


PRODUCT

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page32
SDH Unit (Cont.)

Slot available
Board
OSN 3500
Name OSN 1500A OSN 1500B OSN 2500
40G 80G 200G
SLQ4 6 ~ 8, 11 5 ~ 8, 11 ~ 14
SLD4 ~ 13

SL4
5 ~ 8,
SLT1 12, 13 11~13
11 ~ 13 1 ~ 8, 11 1 ~ 8, 11 ~ 17
SLO1
~ 16
SLQ1
SL1

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page33
SDH Unit (Cont.)
 Boards Description
Board Full name Connector type  Signal processing
with electrical
2 x STM-1 processing with electrical
SEP1 SMB interface board
interface board

Board Full name


SLH1 16 x STM-1 processing board  Signal processing
SEP 8 x STM-1 processing board

Board Full name Connector (Interface) type


OU08 8 x optical signal access board LC/SC (I-1 and S-1.1)  Interface
EU08 8 x electrical signal access board SMB
EU04 4 x electrical signal access board SMB

Board Full name


TSB4 Tributary Switch Board for 4 signals
 TPS
TSB8 Tributary Switch Board for 8 signals

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page34
SDH Unit (Cont.)
 SEP1
 No need for interface board

 SMB interfaces on the front panel are used

 Can be inserted in all line slots

 SEP
 Need interface board: EU08, OU08, EU04
 SMB interfaces on the front panel are inhibited

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page35
SC Connector

SFP Module

PRODUCT
CLASS 1
LASER
TSB8

TSB8

Page36
OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7 OUT8 IN8
OU08

OU08
OUT1IN1 OUT2IN2 OUT3IN3OUT4IN4OUT5IN5 OUT6IN6OUT7IN7OUT8 IN8
OU08

OU08

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.


EU04
EU04
SDH Unit (Cont.)

OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4


EU08

EU08
OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7 OUT8 IN8
AOUT AIN BOUT BIN

SEP1
SEP1

PROG
STAT

SRV
ACT

SLH1
SLH1

PROG
STAT

SRV
ACT

M
B

C
S

n
o

o
e
c

r
t
SDH Unit (Cont.)
 Slot available

Slot available
Board
OSN OSN OSN OSN 3500 OSN 7500
Name
1500A 1500B 2500 40G 80G 200G 240G 360G
5 ~ 8,
SEP1 12,13 11~13 1 ~ 6, 13 ~ 16 1 ~ 3, 17, 18
11 ~ 13
2 ~ 5,
SLH1 - - - -
13 ~ 16
2, 3, 17, 18
6 ~ 7,
SEP 12, 13 2 ~ 5, 13 ~ 16
12 ~ 13
OU08 19, 21,
- 23, 25, 19 ~ 26,

EU08 1 ~ 4, 29, 31, 29 ~ 36 19 ~ 22, 35 ~ 38
14, 16
15 ~ 18 33, 35
19, 21, 23, 25, 29, 31, 33,
EU04
35
TSB4
14 1,17 19,35 37,38
TSB8

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page37
SDH Unit (Cont.)
 Boards Description
Connector
Board Full name Module available
type
2 x STM-4 processing with
R1SLD4
optical interface board
I-4, S-4.1, L-4.1, L-4.2, Ve-4.2
STM-4 processing with optical
R1SL4
interface board
LC
4 x STM-1 processing with
R1SLQ1
optical interface board
I-1, S-1.1, L-1.1, L-1.2, Ve-1.2
STM-1 processing with optical
R1SL1
interface board

 Signal processing with optical interface board

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page38
SDH Unit (Cont.)
SFP Module

R1SLD4 R1SL4 R1SLQ1 R1SL1

STAT
STAT STAT STAT
ACT ACT ACT ACT
PROG PROG PROG PROG
SRV SRV SRV SRV
OUT1 IN1 OUT2 IN2

OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4


OUT IN

OUT IN
R1SLD4 R1SL4 R1SLQ1 R1SL1

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page39
SDH Unit (Cont.)
 Slot available

Slot available
Board
OSN OSN OSN 3500
Name OSN 2500
1500A 1500B 40G 80G 200G
1 ~ 3, 11 ~
R1SLD4 7, 21
13
R1SL4 2, 3, 6 ~ 9, -
12, 13 1 ~ 3, 6 ~ 9, 5 ~ 7,19 ~
R1SLQ1 11 ~ 13 21
R1SL1

 “R1-” boards are used in the small slots in OptiX OSN 1500 or when slots are segmented in
OptiX OSN 1500/2500.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page40
SDH Unit (Cont.)
 Indicator

Indicator Status Color Description

On, green Board works normally.


STAT
On, red Board hardware fails.
Board Status
Off Board is powered off.

ACT On, green Board is activated/configured.


Board
Activation Off Board is not activated/configured.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page41
SDH Unit (Cont.)
 Slot available
Indicator Status Color Description
Upload of board software to FLASH or the FPGA
On, green upload is normal, or the board software
initialization is normal.
On for 100ms and off for Board software is being uploaded to FLASH or
PROG 100ms alternatively, green FPGA.
Board On for 300ms and off for Board software is initializing, and is in BIOS boot
Software 300ms alternatively, green stage.
Board software in FLASH or the FPGA
On, red configuration is lost, resulting in upload and
initialization failure.
Off No power supply.
On, green Service is normal and no service alarm occurs.
SRV On, red Critical or major alarm occurs to service.
Service
Alarm On, yellow Minor or remote alarm occurs to service.
Off No service configured or no power supply.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page42
SDH Unit (Cont.)
 Functions of SL16
Collect Alarm and
performance

Send to Cross-connect unit


16
X
VC4

……
STM-16

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page43
SDH Unit (Cont.)
 Features of SL16
 Fixed wavelength output

 Automatic laser shutdown (ALS) function

 Swappable optical module (SFP)

 Support VC-4-4c, VC-4-8C and VC-4-16c

services

 Inloop and outloop function

 Setting and querying of the REG working 1 Last six digits of BOM
2 Internal number
3 Board version
mode 4 Board name
5 Board characteristic number

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page44
SDH Unit (Cont.)
 Optical port parameters of SL16
Optical interface type I-16 S-16.1 L-16.1 L-16.2 L-16.2Je V-16.2Je U-16.2Je
(Board characteristic #) (01) (02) (03) (04) (02) (BA) (03) (BA+PA) (04)

Wavelength (nm) 1310 1310 1310 1550 1550 1550 1550.12

Distance (km) 0~2 2~15 15~40 40~80 80~100 80~140 140~170

Launched power (dBm) -10~-3 -5~0 -2~3 -2~3 5~7 14 17

Receiver sensitivity (dBm) -18 -18 -27 -28 -28 -28 -34

Receiver overload (dBm) -3 0 -9 -9 -9 -9 -10

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page45
SDH Unit (Cont.)
 Common alarms of SDH unit
Alarm level Color Alarm name Alarm reason
Critical R_LOS Receiver can not receive STM-N signal normally.
MS_AIS Critical alarm e.g. R_LOS happens.
Critical alarm e.g. R_LOS happens.
AU_AIS Wrong service configuration
Major
Faulty SDH board
POWER_
Power module of the line board fails.
ABNORMAL
Opposite station receives the R_LOS, R_LOF or MS_AIS
signal
MS_RDI
Faulty receiver at the opposite node or transmitter at the local
node
Minor Opposite node receives such alarms as AU_AIS and AU_LOP.
HP_RDI Faulty receiver at the opposite node or transmitter at the local
node
LOOP_ALM Software inloop or outloop is being performed.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page46
SDH Unit (Cont.)
 Common performance events of SDH unit
Performance name Performance meaning
RSBBE Regenerator section block of background error
MSBBE Multiplex section block of background error
MSFEBBE Multiplex section far end block of background error
HPBBE High-order path block of background error
HPFEBBE High-order path far end block of background error
RPLCUR Current value of input optical power
RPLMAX Maximum value of input optical power
RPLMIN Minimum value of input optical power
TPLCUR Current value of output optical power
TPLMAX Maximum value of output optical power
TPLMIN Minimum value of output optical power

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page47
PDH Unit
Board Name Description Interface board
SPQ4 Processes 4 x E4/STM-1 MU04
PD3 Processes 6 x E3/T3 D34S
PL3 Processes 3 x E3/T3 C34S
PL3A Processes 3 x E3/T3 -
PQM Processes 63 x E1/T1
D75S, D12S, D12B
PQ1 Processes 63 x E1
PD1 Processes 32 x E1/T1 L75S,L12S,D75S,D12S,D12B

PL1 Processes 16 x E1/T1 -

 PD1 and PL1 are used in the small slot in OptiX OSN 1500/2500.
 L75S/L12S can be only used in OptiX OSN 1500A.
 PD1 cooperates with L75S/L12S in OptiX OSN 1500A, and cooperates with D75S/D12S in
OptiX OSN 2500 or OptiX OSN 1500B.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page48
PDH Unit (Cont.)
 Slot available

Slot available
Board
OSN OSN OSN OSN 3500
Name
1500A 1500B 2500 40G 80G 200G
SPQ4
6, 7, 12,
PD3 - 12, 13 2 ~ 5, 13 ~ 16
13
PL3
5 ~ 8, 1 ~ 8, 11 ~
PL3A 12, 13 11~13 1 ~ 8, 11 ~ 17
11 ~ 13 16
MU04
1, 3, 15,
D34S - 14, 16 19, 21, 23, 25, 29, 31, 33, 35
17
C34S

 PL3A is a processing board with cables led out from the front panel. .

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page49
PDH Unit (Cont.)
 SPQ4/MU04 SPQ4
STAT
ACT
MU04

PROG
SRV

SMB connector

Indicators

OUT1 IN1 OUT2 IN2


OUT3 IN3 OUT4 IN4
SPQ4 MU04

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page50
PDH Unit (Cont.)
PL3A D34S C34S
PD3 PL3
STAT
STAT STAT ACT
ACT ACT PROG
PROG PROG SRV
SRV SRV

SMB connector
Indicators

OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6

OUT1 IN1 OUT2 IN2 OUT3 IN3


OUT1 IN1 OUT2 IN2 OUT3 IN3

PD3 PL3 PL3A D34S C34S

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page51
PDH Unit (Cont.)
 Slot available

Slot available
Board
OSN OSN OSN 3500
Name OSN 2500
1500A 1500B 40G 80G 200G

PQM
- 11 ~ 13 14 ~ 17 1 ~ 5, 13 ~ 16
PQ1

D75S

D12S - 14 ~ 17 1 ~ 4, 15 ~ 18 19 ~ 26, 29 ~ 36

D12B

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page52
PDH Unit (Cont.)
 Slot available

Slot available
Board
OSN OSN OSN 3500
Name OSN 2500
1500A 1500B 40G 80G 200G

1 ~ 3, 6 ~ 5 ~ 7, 19 ~
PD1 2, 12
8, 11 ~ 13 21

PL1 6~9 6~9 -



L75S
6~7 - -
L12S
 PL1 is a processing board with cables let out from the front panel.
 PD1/PL1 can be used in the small slot or used when slots are segmented in OptiX
OSN 1500/2500.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page53
PDH Unit (Cont.)
Indicators DB44
PQ1 D75S D12S D12B
PQM
STAT STAT
ACT ACT
PROG PROG
SRV SRV

1~8

1~8

1~8
2mmHM

9~16
9~16

9~16
PD1 PL1 L75S L12S
STAT STAT

17~24
17~24

17~24
ACT ACT
PROG PROG
SRV SRV

25~32
25~32

25~32

1-16
1-16

1-16
PQM D75S D12S D12B
PQ1

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page54
PDH Unit (Cont.)
 Functions of PQ1
Collect Alarm and
performance

Send to Cross-connect unit


1 X VC4
63
X
E1

E1

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page55
PDH Unit (Cont.)
 Features of PQ1
 Interface Type: 75Ω or 120Ω

 Support Inloop and outloop functions

 Support Warm and Cold reset

 Support TPS function

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page56
PDH Unit (Cont.)
 Common alarms of PDH unit
Alarm level Color Alarm name Alarm reason
The interface board and the processing board are
ALM_SUBCARD_ABN
mismatched
T_ALOS No E1 service is accessed
Major
Critical alarm e.g. R-LOS happens
TU_AIS Wrong service configuration
Faulty PDH board
Opposite node receives such alarms as TU_AIS
LP_RDI
Minor and TU_LOP
LP_REI LPBBE happens on the opposite node

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page57
PDH Unit (Cont.)
 Common performance of PDH unit

Performance name Performance meaning

LPBBE Low-order path block of background error

LPFEBBE Low-order path far end block of background error

LPES Low-order path errored second

LPFEES Low-order path far end errored second

TUPJCHIGH Count of positive TU pointer justifications

TUPJCLOW Count of negative TU pointer justifications

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page58
Ethernet Unit

Ethernet Number of ports on the front panel

E G T 2

G: Gigabit Ethernet (GE) T: Transparent transmission


F: Fast Ethernet (FE) S: L2 switching
M: Multiple (GE+FE) R: RPR (Resilient Packet Ring )

 Note:
 If there is no port on the board, then the board must work with an interface board.
 ETF8/EFF8 is the interface board. ETF8 accesses 8×FE twisted pair signal, and
EFF8 accesses 8×FE optical signal

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page59
Ethernet Unit
 Boards Description

Board Full name Interface type Connector

4 x GE with L2 switching
EGS4 1000BASE-SX/LX/ZX LC
processing with interface board
2 x GE with L2 switching
EGS2 1000BASE-SX/LX/ZX LC
processing with interface board
2 x GE transparent transmission
EGT2 1000BASE-SX/LX/ZX LC
processing with interface board

4 GE + 16 x FE with L2 switching 1000BASE-SX/LX/ZX,


EMS4 RJ-45, LC
processing with interface board 100Base-FX (From interface board)

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page60
Ethernet Unit (Cont.)
EGS4 EGS2 EGT2 EMS4
STAT STAT
STAT STAT
ACT ACT
ACT ACT
PROG PROG
PROG PROG
SRV SRV SRV
SRV
LINK1 LINK1
ACT1 ACT1
LINK2 LINK2
ACT2 ACT2

CLASS 1 CLASS 1
LASER LASER
PRODUCT PRODUCT
CLASS 1
LASER
CLASS 1
LASER CLASS 1
PRODUCT PRODUCT
LASER
PRODUCT

OUT1 IN1
OUT1 IN1

OUT1 IN1

OUT1 IN1

OUT2 IN2
OUT2 IN2

OUT2 IN2

OUT2 IN2

OUT3 IN3
OUT3 IN3

Indicator Color Status Description

On Link is established
OUT4 IN4
OUT4 IN4

LINK
LINK ACT LINK ACT Off Link is not established

Flashing Data exchanged


EGS2 EMS4
ACT
EGS4 EGT2
Off No data being exchanged

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page61
Ethernet Unit (Cont.)
Board Full name EGR2 EMR0
STAT STAT
ACT
PROG
ACT
SRV PROG
LINK1 SRV
EGR2 2 x GE RPR processing with interface board ACT1
LINK2
LINK
ACT
ACT2

CLASS 1
CLASS 1
LASER
LASER

EMR0 1 GE + 4 (12) x FE RPR processing with interface board


PRODUCT
PRODUCT

OUT1 IN1
OUT1 IN1
 Function

OUT2 IN2
 EVPL/EVPLAN Service FE1

 QoS
FE2

 Resilient Packet Ring Function


FE3
 Weighted fair algorithm and three service levels
 Auto discovery of topology GE PORT FE4

SFP Module
 Wrap and steering protection
FE PORT EGR2 EMR0

RJ 45 connector

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page62
Ethernet Unit (Cont.)
 Slot available

Slot available
Board
OSN OSN OSN 3500
Name OSN 2500
1500A 1500B 40G 80G 200G

EGS4 -
EGS2 11 ~ 13 1 ~ 8, 11 ~ 16
12, 13 5 ~ 8, 11 ~
EGT2 13
1 ~ 4, 15
EMS4 - (11)12, 13 1 ~ 6, 13 ~ 16
~16
EGR2 6, 7, 12, 13 1 ~ 8, 11 ~ 16
12, 13 (11)12, 13 5 ~ 8, 11 ~
EMR0 1 ~ 6, 13 ~ 16
13

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page63
Ethernet Unit (Cont.)
 Boards Description

Board Full name Interface type Connector

4 x FE with L2 switching processing


EFS4 10Base-T/ 100Base-TX RJ-45
with interface board
8 x FE with L2 switching processing
EFS0 - -
board
8 (16) x FE transparent transmission
EFT8 10Base-T/ 100Base-TX RJ-45
processing with interface board

8 x FE twisted pair signal access


ETF8 10Base-T/ 100Base-TX RJ-45
board

8 x FE twisted pair signal access


ETS8 10Base-T/ 100Base-TX RJ-45
switching board

EFF8 8 x FE optical signal access board 100Mbit/s-FX LC

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page64
Ethernet Unit (Cont.)
EFS4 EFS0 EFT8

STAT STAT
ACT STAT
ACT ACT
PROG PROG PROG
SRV SRV SRV

RJ 45 connector

FE1

FE2

FE1
FE3

FE4

FE2 EFT4
FE5 STAT
ACT
PROG
FE6 SRV

FE3 FE7

FE1
FE8

FE2
FE4

FE3
FE4
EFS4 EFS0 EFT8

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page65
Ethernet Unit (Cont.)
ETS8 EFF8 ETF8
1
FE PORT 2
3
4
RJ 45 5
6
7
8
Connector LINK ACT

OUT1 IN1 OUT2 IN2 OUT3 IN3 OUT4 IN4 OUT5 IN5 OUT6 IN6 OUT7 IN7 OUT8 IN8
FE1
FE2
FE3

FE1
Board Name Interface Board
FE4

FE2
EFT8 ETF8,EFF8

FE3
FE5

EFS0 ETF8,EFF8,EFS8

FE4
FE6
FE7

EMS4
FE5 ETF8,EFF8
FE8

EMR0
FE6

CLASS 1
LASER
FE7

PRODUCT
FE8

ETS8 EFF8 ETF8

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page66
Ethernet Unit (Cont.)
 Boards Description
Slot available
Board
OSN OSN OSN 3500
Name OSN 2500
1500A 1500B 40G 80G 200G
5 ~ 8, 11 ~
EFS4 12, 13 11 ~ 13 1 ~ 8, 11 ~ 16 (17)
13
EFS0 6, 7, 12, 13 2 ~ 5, 13 ~ 16
7, 12, 13
- 12 ~ 13
EFT8 (5 ~ 8, 11 ~ 1 ~ 6, 13 ~ 16
13)
1 ~ 3,
2, 3, 6, 9, 5 ~ 7, 19 ~
EFT4 6 ~ 9, -
12, 13 21
12, 13
ETF8
ETS8 - 14 ~ 16 1, 3, 15, 17 19, 21, 23, 25, 29, 31, 33, 35
EFF8

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page67
Ethernet Unit (Cont.)
 Function of EFS4

Collect Alarm and


performance

Send to Cross-connect unit


FE GFP

N×VC12/VC3
4 VC-12-Xv(x≤63), 8 X VC4
X VC-3-Xv(x≤12)
FE

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page68
Ethernet Unit (Cont.)
 Features of EFS4
 Supports bandwidth auto-sensing

 Supports MPLS

 Supports LCAS

 Supports Port based flow control

 Supports receiving and transmitting Ethernet testing frame

 Supports inloop at Ethernet port and inloop and outloop at VC3 level

 Supports port level Ethernet performance monitoring

 Supports EPL/EPLAN/EVPL/EVPLAN services and QoS

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page69
Ethernet Unit (Cont.)
 Common alarms of Ethernet unit

Alarm level Color Alarm name Alarm reason

HARD_BAD Faulty board hardware


Critical
ETH_LOS Interrupted Ethernet link

TU_AIS_VC3 Interrupted contiguous VC3-xc


Major
PROTOCOL_MM Mismatched encapsulation protocol

LP_RDI_VC3 TU_AIS_VC3 happens in the opposite node

Minor LCAS_BAND_
VC-Trunk bandwidth decreases
DECREASED

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page70
Ethernet Unit (Cont.)
 Common performance events of Ethernet unit
Performance name Performance meaning
DropOv Number of packet losses is over upper alarm threshold
DropUd Number of packet losses is under lower alarm threshold
RxBadOctOv Number of the bytes of bad packets received is over upper alarm threshold

RxBadOctUd Number of the bytes of bad packets received is under lower alarm threshold

TxBadOctOv Number of the bytes of bad packets transmitted is over upper alarm threshold

Number of the bytes of bad packets transmitted is under lower alarm


TxBadOctUd
threshold
ColOv Number of detected conflicts is over upper alarm threshold
ColUd Number of detected conflicts is under lower alarm threshold

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page71
ATM Unit
 Boards Description

Connector
Board Full name Interface type
type

1 x STM-4 ATM processing with interface


ADL4 S-4.1, L-4.1, Ve-4.1, L-4.2
board

4 x STM-1 ATM processing with interface Ie-1, S-1.1, Ve-1.2, L-1.2,


ADQ1
board L-1.1
LC
1 x STM-4 ATM/IMA processing with
IDL4 S-4.1, L-4.1, L-4.2, Ve-4.2
interface board

4 x STM-1 ATM/IMA processing with Ie-1, S-1.1, L-1.2, Ve-1.2,


IDQ1
interface board L-1.1

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page72
ATM Unit (Cont.)
ADL4 ADQ1 IDL4 IDQ1
STAT STAT STAT STAT
ACT ACT ACT ACT
PROG PROG PROG PROG
SRV SRV SRV SRV

CLASS 1 CLASS 1 CLASS 1 CLASS 1

LASER LASER LASER LASER


PRODUCT PRODUCT PRODUCT PRODUCT

OUT1 IN1

OUT1 IN1
OUT1 IN1

OUT1 IN1
S
CLASS 1 F

OUT2 IN2

OUT2 IN2
LASER
PRODUCT
P

OUT3 IN3
C

OUT3 IN3
O
N
N
OUT4 IN4

OUT4 IN4
E
C
T
O
ADL4 ADQ1 IDL4 IDQ1
R

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page73
ATM Unit (Cont.)
 Slot available

Slot available
Board
OSN OSN OSN 3500
Name OSN 2500
1500A 1500B 40G 80G 200G

ADL4
6 ~ 8, 11
1 ~ 8, 11 ~ 17
~ 13
ADQ1
(11), 12,
12, 13 7, 8, 11-13
13
IDL4
1 ~ 8, 11
1 ~ 8,11 ~ 17
~ 16
IDQ1

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page74
ATM Unit (Cont.)
 Function of ADQ1

Collect Alarm and


performance

Send to Cross-connect unit


Mapper
ATM
8
VC-12, VC-4, VC-
X
4-Xv
4 VC4
X
ATM

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page75
ATM Unit (Cont.)
 Features of ADQ1
 Supports CBR, rt-VBR, nrt-VBR and UBR

 Supports QoS

 ATM switching capability: 1.25 Gbit/s

 Max. uplink bandwidth: 8 VC-4, or 12 VC-3 + 4 VC-4

 E3 traffic can be received from PDH board

 Supports ATM multicast connection

 Supports VP-Ring and VC-Ring

 Uni-directional/bidirectional 1+1 and 1:1 board protection

 Supports inloop and outloop

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page76
ATM Unit (Cont.)
 Common alarms of ATM unit

Alarm
Color Alarm name Alarm reason
level

More critical alarms e.g. R_LOS happens.


VPAIS
The faulty ATM board
Critical
More critical alarms e.g. R_LOS happens.
VCAIS
The faulty ATM board

VPRDI The VPAIS is reported on the opposite node ATM board

Major VCRDI The VCAIS is reported on the opposite node ATM board

LCD The cell heads are lost

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page77
ATM Unit (Cont.)
 Common performance of ATM unit
Performance name Performance meaning
VC3BBE VC3 block of background error
VC3ES VC3 errored second
VC3FEBBE VC3 far end block of background error
VC3FEES VC3 far end errored second
ATM_INGCELL Number of input cells in ATM link
ATM_EGCELL Number of output cells in ATM link
ATM_CORRECTED_HCSERR Number of corrected cells with HCS error at ATM interface
ATM_UNCORRECTED_HCSE
Number of uncorrected cells with HCS error at ATM interface
RR
ATM_RECV_CELL Number of cells ATM interface received
ATM_RECV_IDLECELL Number of idle cells ATM interface received
ATM_TRAN_CELL Number of cells ATM interface transmitted

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page78
MST Unit
 Board description

Board Name Description

4 x multi-service transparent transmission


MST4
processing with interface board

 Slot available

Slot available
Board
Name OSN OSN
OSN 2500 OSN 3500
1500A 1500B

5 ~ 8, 11 ~ 1 ~ 8, 11 ~
MST4 12, 13 11 ~ 13
13 16 (17)

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page79
MST Unit
 Service Types

Service type Rate Remarks

GE 1000 Mbit/s Data service

FC50 531.25 Mbit/s Storage Area Network (SAN)

FC100/FICON 1062.5 Mbit/s SAN service

FC200 2125 Mbit/s SAN service

ESCON 200 Mbit/s SAN service

DVB-ASI 270 Mbit/s Video service

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page80
MST Unit (Cont.)
MST4

STAT
ACT
 Features of MST unit
PROG
SRV

 Total uplink bandwidth 2.5G

 Supports GFP-T encapsulation


OUT1 IN1

S  Inloop and outloop function at the client side


F
OUT2 IN2

P  Distance extension function for ports 1 and 2


C
SFP Modules
OUT3 IN3


O
N
N
OUT4 IN4

E Services SDH side Client side


C
T FC100 3000km 40km
O
MST4 R FC200 1500km 20km

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page81
MST Unit (Cont.)
 Function

Collect Alarm and


performance

Send to Cross-connect unit


GFP-T
SAN
16
Multi-Services

VC-4-4c/8c/16c X
VC4

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page82
Core Unit -OSN 1500/2500
 The CXL1/CXL4/CXL16 is the core unit used in OptiX OSN 1500/2500.
Cross-connect Unit Timing Unit SCC Unit Line Unit

Location in OptiX OSN 1500A and


OptiX OSN 1500B: slot 4 and 5

Location in OptiX OSN 2500: slot 4 and 5

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page83
Cross-Connect Unit
SDH unit PDH unit Data unit

Collect Alarm

High-order cross-connect
matrix

Low-order cross-connect Multi-


Granularity:
matrix VC12/VC3/VC4/V
C-4-xc

Flexible service cross-connect,


loopback, multicast and broadcast

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page84
Cross-Connect Unit –OSN1500/2500
CXL16 CXL4 CXL1
STAT STAT
ACTX
STAT
ACTX ACTX
ACTC ACTC
PROG ACTC
PROG
SRVX SRVX PROG
SRVL SRVL SRVX
SYNC SYNC SRVL
ALMC ALMC SYNC
ALMC
CLASS 1
CLASS 1
LASER CLASS 1
LASER
PRODUCT LASER
PRODUCT
PRODUCT
Indicator Color Description

Board works normally


OUT IN
OUT IN

OUT IN

STAT Board hardware fails

RESET RESET
Board is powered off
RESET

ALM CUT ALM CUT ALM CUT


ACTX Cross-connect unit is in active status

Cross-connect unit is in standby status

Logical unit
 GXCL (5G)
CXL16 CXL4 CXL1  EXCL (20G)

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page85
Cross-connect Unit –OSN3500

 The cross-connect unit is inserted in slot 9 or 10 of OptiX OSN 3500.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page86
Cross-Connect Unit –OSN3500
 OSN 3500

For Extension
Cross-connect Max access High-order cross- Low-order cross-
sub-rack HO XC
and timing board capacity connect capacity connect capacity
capacity

GXCS 35G 35G 5G

EXCS 58.75G 75G 5G -

UXCSA 58.75G 60G 20G

UXCSB 60G 60G 20G 1.25G

SXCSA 155G 180G 20G -

SXCSB 156.25G 180G 20G 1.25G

XCE 1.25G - 1.25G -

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page87
Cross-Connect and Timing Unit –
OSN3500
GXCSA EXCSA UXCSA UXCSB XCE SXCSA SXCSB
STAT STAT STAT STAT STAT STAT
ACT STAT
ACT ACT ACT ACT ACT ACT
PROG PROG PROG PROG PROG PROG
SRV PROG
SRV SRV SRV SRV SRV SRV
SYNC SYNC SYNC SYNC SYNC SYNC SYNC

EXA EXA EXA

EXB EXB
EXB

GXCSA EXCSA UXCSA UXCSB XCE SXCSA SXCSB

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page88
Cross-connect Unit –OSN3500
DB26 Connector:
UXCSB XCE
STAT
ACT
STAT
ACT
To connect the main
PROG PROG
SRV
SYNC
SRV
SYNC
sub-rack and the
extension sub-rack UXCSB/SXCSB
together.
EXA EXA

EXA EXA

EXB EXB

EXB EXB

EXA EXA

EXB EXB

UXCSB XCE

XCE

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page89
Cross-Connect Unit

10G line unit 10G line unit

2.5G line unit


Cross- 2.5G line unit
connect

Cross-
Standby
PDH unit connect PDH unit

Active

Ethernet unit Ethernet unit

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page90
Cross-Connect Unit (Cont.)
 Features
 Support SNCP protection for VC-4-4C, VC-4-8C, VC-4-16C,

VC-4-64C, VC-4, VC-12, VC-3

 Support 1+1 hot backup

 Active/standby Restoration

 Inserted in slots 9 (Active) and 10 (Standby)

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page91
Timing Unit –OSN1500/2500

Indicator Color Description

Clock works in Normal mode


SYNC
Clock works in hold-over or free-run mode

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page92
Timing Unit –OSN3500

Indicator Color Description

ACT ON Board is active/OFF Board is standby

Clock works in Normal mode


SYNC
Clock works in hold-over or free-run mode

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page93
Timing Unit
 Features
 Process traced clock signal from Line, Tributary and external clock

 Process 2 x Input/ 2 x Output 2Mbits/2Mhz external clock signals

 Support Normal (Trace), Hold-over and Free-run clock status working


modes

 Process SSM byte to realize clock protection switching


 Non-synchronization status message (SSM) mode

 Standard SSM mode

 Extended SSM mode

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page94
Cross-Connection & Timing Unit
 Common alarms of Cross-Connect and Timing unit
Alarm level Color Alarm name Alarm reason
Chip of the cross-connect board is damaged
BUS_ERR
Damaged backplane bus
Major APS_INDI MSP switching happens
TEMP_OVER Ambient temperature is too high.
W_OFFLINE Ejector lever on the front panel is rotated to the open position.
EXT_SYNC_LOS Physical interface signal of the external clock source is lost.
Minor CLOCK_ENTER_NO
Clock working mode changes from locked into holdover or free-run.
_TRACE_MODE
Multiplex section protection switching fails.
APS_FAIL
MS node information is lost or set incorrectly
Warning
SWITCH_DISABLE Board switching is disabled
OTH_BD_STATUS Another board pulled out or plugged in

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page95
System Control & Communication Unit

SDH unit
Commands
PDH unit
Collect Alarm and
NMS
performance
Other unit

Cross-connect unit DCC

Other NE

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page96
System Control & Communication Unit –
OSN1500/2500
CXL1
 Active SCC unit ACTC ( )
STAT
ACTX
ACTC
PROG
SRVX
SRVL
SYNC
ALMC
 Standby SCC unit ACTC ( )
CLASS 1
LASER
PRODUCT

 To warm reset board, press RESET


OUT IN

Reset board
 To cut buzzer temporarily, press ALMC for 1 second ( )

RESET
 To cut buzzer permanently, press ALMC for 3 seconds ( )
ALM CUT

 To re-enable buzzer, press ALMC for 1 second ( )


Alarm cut
switch (short
and long
press)
Logical unit
 SCC
CXL1  GSCC (with ASON)

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page97
System Control & Communication Unit –
OSN3500 (Cont.)
Indicator Color Description
SCC GSCC

STAT
STAT
ACT
PROG
ACT
PROG The –48 V power supply A is normal.
SRV
PWRA
PWRB
Reset SRV
PWRA
PWRB PWRA
PWRC PWRC
ALMC ALMC
The –48 V power supply A is faulty (lost or failed).

The –48 V power supply B is normal.


PWRB
RESET
The –48 V power supply B is faulty (lost or failed).

The 3.3 V protection power is normal.


ALM CUT PWRC
The 3.3 V protection power is lost.
RESET
Currently in permanent alarm cut-off status.
ALMC
Give audible warning upon critical alarm.
Alarm cut ALM CUT

 To warm reset board, press RESET

 To cut buzzer temporarily, press ALMC for 1 second ( )

 To cut buzzer permanently, press ALMC for 3 seconds ( )

SCC GSCC
 To re-enable buzzer, press ALMC for 1 second ( )

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page98
System Control & Communication Unit
(Cont.)
 Functions
 Service configuration, grooming and monitoring
 Collects alarm and performance events
 Supports NE ID setting by software
 1+1 hot backup
 Extended ECC
 Controls cabinet indicators and fans
 3 Housekeeping alarm inputs and 1 alarm outputs
 Supports ASON intelligent function
 OSN3500: Inserted in slot 18 (Active) and/or Slot 17 (Standby)

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page99
System Control & Communication Unit
(Cont.)
 Extended ECC function

NMS

Ring A Ring B

Ethernet L< 50m Ethernet


port port

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page100
System Control & Communication Unit
(Cont.)
 Four databases on the SCC MDB
Issued data
Automatically saves the current
data in dynamic RAM.
If power fails, the data in MDB will
be lost.
MDB

DRDB
Automatically saves the Fail NE in installing
verify status
successfully verified data.
If power fails, the data in
Success
DRDB will be lost.

Boards in
FDB0, FDB1
DRDB running status
Manually or periodically
saves the data. Enduringly Save manually or
saves data and does not periodically every 30 mins
need battery.
FDB0
FDB1

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page101
System Control & Communication Unit
(Cont.)
 Common alarms of SCC unit

Alarm level Color Alarm name Alarm reason

Critical NESTATE_INSTALL NE is in the installing state.

Software in the master and slave SCC are


MSSW_DIFFERENT
mismatched

Inserted board and the configured board are


WRG_BD_TYPE
mismatched

Major NESF_LOST Host software is lost.

Faulty power resource, e.g. the 3.3V power module


POWER_ABNORMA
of the SCC or AUX, and the 3.3V backup power
L
module, and 2 channels of – 48V

POWER_FAIL Too low battery voltage on the SCC

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page102
Auxiliary Unit
 Board Description
Board Function Remark
AUX Auxiliary Interface Board -
PIU Power Interface Board -
EOW Orderwire Board -
SAP System Auxiliary Process Only for OptiX OSN 2500
SEI System Extended Interface Only for OptiX OSN 2500
UPM Uninterruptible Power Modules External
AMU Auxiliary Monitoring Unit Only for OptiX OSN 1500
BA2 Booster Amplifier Board -
BPA Pre-amplifier Board -
COA Case-based Optical Amplifier External
DCU Dispersion Compensation Board Only for OptiX OSN 3500/7500
FAN/FANA Fan unit -

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page103
Auxiliary Unit –AUX&AMU (OSN 1500)
ETH: T2000 Interface
AUX

AUX
ETH COM CLK ALM OAM/F&f
 The AUX board used in
OptiX OSN 1500 is inserted
COM: Commissioning Interface in slot 10.
CLK : 120 ohms external clock input/output interface
ALM: House-keeping alarm input/output interface
OAM/F&f: NM and management serial interface
PHONE: Orderwire Interface

 The AMU board used in


AMU

AMU
PROG
STAT
OptiX OSN 1500 is inserted PHONE S1 S2 LAMP1 LAMP2
in slot 9.

S1&S2: Broadcast data channels interfaces


LAMP1&LAMP2: Provide drive current for cabinet indicators

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page104
Auxiliary Unit -SAP&SEI (OSN 2500)
ALMO1/2: Alarm output  SAP is the system auxiliary
Q1SAP
ALMI1/2: 8 x Environment alarm input processing board. It is inserted in STAT
PROG

slot 14 in OptiX OSN 2500. PWRA


PWRB
PWRC

LAMP1/2: Cabinet indicator output  SEI provides various auxiliary


OAM: X.25 OAM interfaces and management
F1: Co-directional data 64 Kbit/s interfaces. It is on top of the sub-
S1 ~ S4: Serial 1 ~ 4 broadcast data rack.

F&f: LCT
PHONE: Orderwire
CLK1/2: 120 Ω Ext clock input/output 1/2
V1/2: NNI Audio/Signaling

LAMP LAMP OA F&


ALMO1 ALMO2 F1 PHONE CLK1 CLK2
1 2 M f
COM
CLKO1 CLKO2 CLKI1 CLKI2

ALMI1 ALMI2 S1 S2 S3 S4 V1 V2
ETH

CLKO1/2: 75 Ω Ext clock output 1/2 Q1SAP


CLKI1/2: 75 Ω Ext clock input 1/2

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page105
Auxiliary Unit -AUX (OSN 3500)
 The AUX board used in OptiX OSN 3500 provides system
auxiliary interfaces. It is inserted in slot 37.

75 ΩExt clock input 1/2 ALMI1 ~ 4: Environment alarm input


75 Ω Ext clock output 1/2 S1 ~ S4: Serial 1 ~ 4 broadcast data
Board status
CLKI1 CLKI2 CLK2 ETH COM EXT ALMP1 ALMP2 ALMO1 ALMO2 ALMI1 ALMI2 ALMI3 ALMI4
STAT

NIAUX
NIAUX

CLKO1 CLKO2 CLK1 REV F&f F1 PHONE V1 V2 OAM S1 S2 S3 S4

CLK1/2: 120 Ω Ext clock input/output 1/2 ALMP1/2: Cabinet indicator output
ETH: T2000 ALM01/2: Alarm output
COM: Commissioning Phone: Orderwire
EXT: Extended sub-rack V1/2: NNI Audio/Signaling
REV: - OAM: X.25 OAM
F&f: LCT
F1: Co-directional data 64 Kbit/s

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page106
Auxiliary Unit -PIU
R1PIUA is applicable to the OptiX
P IUA

P IUA
POWER

OSN 1500A and seated in slots 1


NEG(-) RTN(+)
PWS I O and 11

CLK IN

POWER

R1PIU
R1PIU
PWR

Switch
NEG(-) RTN(+) CLK OUT

R1PIU is applicable to the OptiX


Interface Description OSN 1500B and seated in slots 18
and 19
CLK 75Ω synchronization
IN/OUT input/output (SMB) interface

PWR –48 V power access interface Indicator Status Description

50 W power output interface, On, green Power input is normal


Power
PWS supplying power for COA or indicator Off No power input or
HUB power failure

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page107
Auxiliary Unit -PIU
PIU NIPIU

PWS  Used in OSN


3500
 Inserted in slot
RTN(+) 27 and 28
PWR
NEG(-)
PWR

PS1
 Used in OSN 2500
 Inserted in slot 22 and 25 PS2

Interface Description

PWS 50 W power output interface,


supplying power for COA or HUB
NIPIU

PWR –48 V power access interface

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page108
Auxiliary Unit –PIU (Cont.)
 Functions
 Access power –38.4 V ~ –57.6 V DC or -48 V ~ -72 V

 Lightning protection

 Enhanced electro magnetic compatibility (EMC) by filtering and shielding the


power supply from EMI.

 Provide 2 x 50 W power interfaces for external devices such as COA and


HUB.

 1+1 hot backup protection

 Supply power to FAN boards

 Detect input power failures

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page109
Auxiliary Unit -EOW (OSN 1500)
 The EOW board is the orderwire board used in OptiX OSN 1500, which is
inserted in slot 9 of the sub-rack.
 The AMU/EOW or some SDH/PDH unit can be inserted in slot 9 of the sub-
rack. Insert different boards due to different demands.

PHONE: Orderwire interface

S1~S4: 4 broadcast data channel interfaces


EOW

EOW
PROG
STAT

PHONE S1 S2 S3 S4

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page110
Auxiliary Unit -UPM (OSN1500)
 Functions of UPM
 Convert AC 110/220V to DC -48V

 Height 1U

 Consists of converter and battery

 Power feedback is 2 x 270W

 Can be installed in 19 inch cabinet

 Display CAU in T2000 NMS

 Capacity of the battery is 40Ah

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page111
Auxiliary Unit -UPM (OSN1500)
4
BAT
! CAUTION
BAT- DO NOT INVERT POLARITY
注意极性 防止反接
BAT+

48V+

48V-

LOAD1 LOAD2

5 6

AC100~240 RUN ALM

ALM Vout ALM Vout

RS232

1 2 3

1: AC input 2: AC-DC Converter, ventilation 3: Communication interface


4: Battery input 5,6: Power feed interface

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page112
Amplifier Unit -BA2&BPA&COA
Board Description Connector

BA2 Booster Amplifier Board LC


BPA Pre-amplifier Board LC
COA Case-based Optical Amplifier LC

Slot available
Board OSN OSN
OSN 2500 OSN 3500
1500A 1500B

COA External

BA2 5 ~ 8, 11 ~ 1 ~ 8, 11 ~
12, 13 11 ~ 13
BPA 13 16 (17)

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page113
Auxiliary Unit -BA2

Input optical power Output optical power


 -6 ~ +3 dBm  + 13 ~ + 15 dBm
 + 15 ~ +17 dBm

Tx BA Rx

Input/Output optical power detection

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page114
Auxiliary Unit -BA2 (Cont.)
BA2

STA T
ACT
PR OG
SR V

1/ 2 BA modules
LC connector
OUT1 IN1

 Specifications
OUT2 IN2

IN1/2 (dBm) Output 1 (dbm) Output 2 (dbm)

+13 ~ +15 -
CLASS 1
LASER
PRODUCT +15 ~ +17 -

–6 ~ +3 +13 ~ +15 +13 ~ +15

+15 ~ +17 +15 ~ +17


BA2
+13 ~ +15 +15 ~ +17

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page115
Auxiliary Unit -BA2 (Cont.)
 Function
 2 channel power amplification

 Used on TX side

 Fixed output optical power

 Used for 1530 ~ 1565 nm signals

 Reports laser performance parameter

 ALS function

 Automatic control of laser temperature and optical power of the EDFA


module

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page116
Auxiliary Unit -BPA

Receiver sensitivity Gain


 -38 dBm  22 dB

Tx PA Rx

Detects the input/output optical power

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page117
Auxiliary Unit -BPA (Cont.)
BPA

STA T
ACT
PR OG
SR V

Port 1:
BA module
LC connector
BOUT BIN
 Specifications

BIN (dBm) BOUT (dBm) PIN (dBm) POUT (dBm)


POUT PIN

-6 ~ +3 +13 ~ +15 -10 ~ -37 +11 ~ -16

Port 2: - +15 ~ +17 - -


PA module
LC connector

CLASS 1
LASER
PRODUCT

BPA

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page118
Auxiliary Unit -BPA (Cont.)
 Function
 1-channel power amplification

 1-channel pre-amplification

 Fixed output optical power

 Improving the receiver sensitivity to –38 dBm

 BA used for 1530 ~ 1565 nm signals

 PA used for 1550.12 nm signals

 ALS function

 Reports performance parameter

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page119
Auxiliary Unit -COA

8 9 10

1 2 3 4 5 6 7 11
1. ID DIP switch 2. Running indicator 3. Alarm indicator 4. RS232-1

5. RS232-2 6. MONITOR-1 7. MONITOR-2 8. IN input optical port

9. OUT output optical port 10. Power switch 11. –48 V power interface

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page120
Auxiliary Unit -COA (Cont.)
 External installation
 Types
 61COA
 Only one EDFA module
 Can work as BA (+14 dBm or +17dBm), PA (with the receiver sensitivity of –38
dBm ) or LA

 62COA
 Raman amplifier with good noise performance
 used in the RX (with the receiver sensitivity of –39 dBm)
 Ultra long hop transmission for a single span (>170 km )

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page121
Amplifier Unit
 Common alarms of Amplifier unit

Alarm level Color Alarm name Alarm reason

IN_PWR_FAIL No input signal

IN_PWR_HIGH Input power is too high

Critical IN_PWR_LOW Input power is too low

OUT_PWR_ABN Abnormal output power

PUM_COOL_ALARM Faulty EDFA module

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page122
Amplifier Unit
 Common performance of Amplifier unit
Performance name Performance meaning

EDRPLAVG Current value of input optical power

EDRPLMAX Maximum value of input optical power

EDRPLMIN Minimum value of input optical power

EDTMPCUR Current value of environment temperature

EDTMPMAX Maximum value of environment temperature

EDTMPMIN Minimum value of environment temperature

EDTPLCUR Current value of output optical power

EDTPLMAX Maximum value of output optical power

EDTPLMIN Minimum value of output optical power

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page123
Auxiliary Unit -DCU
DC U

Board Description Connector 1/2 DCM


LC connector
DCU Dispersion compensation board LC

OUT1 IN1
OUT2 IN2
Slot available

Board OSN OSN


OSN 2500 OSN 3500 OSN 7500
1500A 1500B

1 ~ 8, 11 ~ 1-8, 11-18,
DCU - - -
17 26-31
DC U

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page124
Auxiliary Unit -DCU (Cont.)
Compensates
60km or 80km

Tx BA PA DCU Rx

Insertion loss ≤7 dB

 Used for 10G signals


 Inserted in slots 1 ~ 8, 11 ~ 16
 Works with BA and PA

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page125
Auxiliary Unit -FAN

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page126
Auxiliary Unit -FAN (Cont.)
 Function
 Support hot swapping

 Intelligent speed adjustment


Indicator Color Description

Fan operates normally.

STAT Fan, fan power board or FANA is abnormal.

Fan is turned off due to low temperature.

Alarm level Color Alarm name Alarm reason

Faulty fan
Major FAN_FAIL
Fan is power off

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page127
Questions
 Please list different boards in OptiX OSN 1500/2500/3500.
SDH Boards

PDH Boards

Ethernet Boards

ATM Boards

MST Boards

WDM Boards

Cross-connect and System


Control Boards
Auxiliary Unit

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page128
Contents
1. Product Introduction

2. Cabinet, Sub-rack

3. Boards

4. Common Network Elements and Configuration

5. Features

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page129
Contents
4. Common network elements
4.1 Terminal multiplexer (TM)

4.2 Add and drop multiplexer (ADM)

4.3 Multi-add and drop multiplexer (MADM)

4.4 Regenerator (REG)

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page130
Terminal multiplexer
 TM

Low rate signals High rate signals


PDH: E1/T1, E3/T3, E4 SDH: STM-1/4/16/64
SDH: STM-1e
DATA: FE, GE, ATM, ...

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page131
Terminal multiplexer (Cont.)
 TM functions

 Add and drop tributary signals


 PDH signals: E1/T1, E3/T3, E4

 SDH signal: STM-1e


 Cross-connect tributary & line unit signals

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page132
Terminal multiplexer (Cont.)
 TM configuration

Tributary unit Line PIU Slot 1 PIU Slot 11 PL1 Slot 6


FAN
PL3A Slot 12 Slot 7
unit Slot 13 Slot 8
CXL16 Slot 4 EOW Slot 9
16 x E1s STM-16 Slot 20 CXL16 Slot 5 AUX Slot 10

3 x E3s
Tributary unit Line PIU Slot 1 PIU Slot 11 L75S Slot 6
FAN
Slot 2 PD1 Slot 12 L75S Slot 7
unit
PL3A Slot 13 Slot 8
CXL16 Slot 4 EOW Slot 9
32 x E1s STM-16
Slot 20 CXL16 Slot 5 AUX Slot 10

3 x E3s OptiX OSN 1500A


Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page133
Terminal multiplexer (Cont.)
 TM configuration

Tributary unit Line unit D75S Slot14


PIU Slot18
D75S Slot15
63 x E1s STM-16 C34S Slot16
PIU Slot19
Slot 17
Slot 20 Slot 11 Slot 6
3 x E3s
PQ1 Slot 12 Slot 7
PL3 Slot 13 Slot8
CXL16 Slot 4 EOW Slot 9
FAN CXL16 Slot 5 AUX Slot 10

OptiX OSN 1500B

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page134
Terminal multiplexer (Cont.)
 TM configuration D D D P P C C S
7 7 3 Q D X X A
5 5 4 1 3 L L P
S S S 1 1
6 6
Tributary unit Line unit

63 x E1s STM-16
S S S S S S S S S S S S S S S S S S
4 x E3s l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8

Fiber routing panel


SLOT 22 SLOT 23 SLOT 24 SLOT 25
PIU FAN FAN PIU

OptiX OSN 2500

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page135
Terminal multiplexer (Cont.)
D D D D D A
3 7 7 7 7 U
 TM configuration 4 5 5 5 5 X
S S S S S
P P
S S S S S S S S I I S S S S S S S S S
l l l l l l l l U U l l l l l l l l l
Tributary unit Line unit o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t
1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
126 x E1s STM-64 9 0 1 2 3 4 5 6 9 0 1 2 3 4 5 6 7

FAN FAN FAN


6 x E3s
P P P S G G S G G
D Q Q L X X E S S
2 x STM-1e 3 1 1 6 C C P C C
4 S S 1 C C

S S S S S S S S S S S S S S S S S S
l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 2 2 3 4 5 6 7 8
OptiX OSN 3500 Fiber Routing

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page136
Add and drop multiplexer
 ADM High rate signals
SDH: STM-1/4/16/64

Low rate signals


PDH: E1/T1, E3/T3, E4
SDH: STM-1e
DATA: FE, GE, ATM, ...

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page137
Add and drop multiplexer (Cont.)
 ADM functions

 Add and drop tributary signals


 PDH signals: E1/T1, E3/T3, E4

 SDH signal: STM-1e


 Cross-connect tributary & line unit signals

 Cross-connect line units pass-through signals

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page138
Add and drop multiplexer (Cont.)
 ADM configuration

PIU Slot 1 PIU Slot 11 PL1 Slot 6


Tributary unit Line unit FAN
PL3A Slot 12 Slot 7

16 x E1s STM-16 Slot 13 Slot 8


CXL16 Slot 4 EOW Slot 9
3 x E3s Slot 20 CXL16 Slot 5 AUX Slot 10

PIU Slot 1 PIU Slot 11 L75S Slot 6


Tributary unit Line unit FAN
Slot 2 PD1 Slot 12 L75S Slot 7
PL3A Slot 13 Slot 8
32 x E1s STM-16
CXL16 Slot 4 EOW Slot 9

3 x E3s Slot 20 CXL16 Slot 5 AUX Slot 10

OptiX OSN 1500A


Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page139
Add and drop multiplexer (Cont.)
 ADM configuration

Tributary unit Line unit D75S Slot14


PIU Slot18
D75S Slot15
63 x E1s STM-16 C34S Slot16
PIU Slot19
Slot 17
Slot 20 Slot 11 Slot 6
3 x E3s
PQ1 Slot 12 Slot 7
PL3 Slot 13 Slot8
CXL16 Slot 4 EOW Slot 9
FAN CXL16 Slot 5 AUX Slot 10

OptiX OSN 1500B

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page140
Add and drop multiplexer (Cont.)
 ADM configuration D D D P P C C S
7 7 3 Q D X X A
5 5 4 1 3 L L P
S S S 1 1
6 6
Tributary unit Line unit

63 x E1s STM-16
S S S S S S S S S S S S S S S S S S
4 x E3s l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8

Fiber routing panel


SLOT 22 SLOT 23 SLOT 24 SLOT 25
PIU FAN FAN PIU

OptiX OSN 2500

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page141
Add and drop multiplexer (Cont.)
D D D D D A
3 7 7 7 7 U
 ADM configuration 4 5 5 5 5 X
S S S S S
P P
S S S S S S S S I I S S S S S S S S S
l l l l l l l l U U l l l l l l l l l
Tributary unit Line unit o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t
1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
126 x E1s STM-64 9 0 1 2 3 4 5 6 9 0 1 2 3 4 5 6 7

FAN FAN FAN


6 x E3s
P P P S G G S S G G
D Q Q L X X L E S S
2 x STM-1e 3 1 1 6 C C 6 P C C
4 S S 4 1 C C

S S S S S S S S S S S S S S S S S S
l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
OptiX OSN 3500 Fiber Routing

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page142
Multi-add and drop multiplexer
 MADM High rate signals
SDH: STM-1/4/16/64

Low rate signals


PDH: E1/T1, E3/T3, E4
SDH: STM-1e
DATA: FE, GE, ATM, ...

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page143
Multi-add and drop multiplexer (Cont.)
 MADM functions

 Add and drop tributary signals


 PDH signals: E1/T1, E3/T3, E4

 SDH signal: STM-1e


 Cross-connect tributary & line unit signals

 Cross-connect line units pass-through signals

 Used as intermediate node for topologies of different optical


signal rates

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page144
Multi-add and drop multiplexer (Cont.)
 MADM configuration

PIU Slot 1 PIU Slot 11 PL1 Slot 6


Tributary unit Line unit FAN
PL3A Slot 12 Slot 7

16 x E1s STM-16 SLQ4 Slot 13 Slot 8


CXL16 Slot 4 EOW Slot 9
3 x E3s STM-4 Slot 20 CXL16 Slot 5 AUX Slot 10

PIU Slot 1 PIU Slot 11 L75S Slot 6


Tributary unit Line unit FAN Slot 2 PD1 Slot 12 Slot 7
PL3A Slot 13 R1SLD4 Slot 8
32 x E1s STM-16
CXL16 Slot 4 EOW Slot 9

3 x E3s STM-4 Slot 20 CXL16 Slot 5 AUX Slot 10

OptiX OSN 1500A


Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page145
Multi-add and drop multiplexer (Cont.)
 MADM configuration

Tributary unit Line unit D75S Slot14


PIU Slot18
D75S Slot15
C34S Slot16
63 x E1s STM-16 Slot 17
PIU Slot19

Slot 20 Slot 11 Slot 6


3 x E3s STM-4 PQ1 Slot 12 Slot 7
PL3 Slot 13 R1SLD4 Slot8
CXL16 Slot 4 EOW Slot 9
FAN CXL16 Slot 5 AUX Slot 10

OptiX OSN 1500B

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page146
Multi-add and drop multiplexer (Cont.)
 MADM configuration D D D P P S C C S
7 7 3 Q D L X X A
5 5 4 1 3 D L L P
S S S 4 1 1
6 6
Tributary unit Line unit

63 x E1s STM-16
S S S S S S S S S S S S S S S S S S
4 x E3s STM-4 l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8

Fiber routing panel


SLOT 22 SLOT 23 SLOT 24 SLOT 25
PIU FAN FAN PIU

OptiX OSN 2500

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page147
Multi-add and drop multiplexer (Cont.)
D D D D D A
3 7 7 7 7 U
 MADM configuration 4 5 5 5 5 X
S S S S S
P P
S S S S S S S S I I S S S S S S S S S
l l l l l l l l U U l l l l l l l l l
Tributary unit Line unit o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t
1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
100 x E1s STM-64 9 0 1 2 3 4 5 6 9 0 1 2 3 4 5 6 7

FAN FAN FAN


6 x E3s STM-16
P P P S S S G G S S G G
D Q Q L L L X X L E S S
2 x STM-1e STM-4 3 1 1 D 1 6 C C 6 P C C
4 6 4 S S 4 1 C C

S S S S S S S S S S S S S S S S S S
l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 2 2 3 4 5 6 7 8
OptiX OSN 3500 Fiber Routing

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page148
Regenerator
 OptiX OSN 2500REG

High rate signals


SDH: STM-64, STM-16, STM-16 (FEC)

3R: Re-amplify, Re-shaping, Re-timing

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page149
Regenerator (Cont.)
 OptiX OSN 2500REG functions

 Regenerates and pass-through line unit signals

 Terminates and regenerates overhead bytes of the regeneration


section and transmit transparently other overhead bytes

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page150
Regenerator (Cont.)
 OptiX OSN 2500REG S S S C C S S S S
L F L R R L F L A
configuration 1
6
1
6
6
4
G G 6
4
1
6
1 P
6

CRG:

 Timing signal S S S S S S S S S S S S S S S S S S
l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
 System control & t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 1 2 3 4 5 6 7 8
communication
Fiber routing panel
SLOT 22 SLOT 23 SLOT 24 SLOT 25
PIU FAN FAN PIU

OptiX OSN 2500

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page151
Regenerator (Cont.)
 OptiX OSN 2500REG fiber connection

Fiber connection for one REG

Fiber connection for multi-REGs

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page152
Regenerator (Cont.)
 OptiX OSN 3500
High rate signals
SDH: STM-64, STM-16, STM-16 (FEC)

Low rate signals


PDH: E1/T1, E3/T3, E4
SDH: STM-1e 3R: Re-amplify, Re-shaping, Re-timing
DATA: FE, GE, ATM, ...

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page153
Regenerator
 OptiX OSN 3500 functions as REG & ADM
 Add and drop tributary signals
 PDH signals: E1/T1, E3/T3, E4

 SDH signal: STM-1e


 Cross-connect tributary & line unit signals

 Cross-connect line units pass-through signals

 Regenerates and pass-through line unit signals

 Terminates and regenerates overhead bytes of the regeneration


section and transmit transparently other overhead bytes

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page154
Regenerator (Cont.)
D D D D D A
3 7 7 7 7 U
 OptiX OSN 3500 4 5 5 5 5 X
S S S S S
P P
configuration as REG & S S S S S S S S I I S S S S S S S S S
l l l l l l l l U U l l l l l l l l l
ADM o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
o
t
1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3
9 0 1 2 3 4 5 6 9 0 1 2 3 4 5 6 7
Tributary unit Line unit FAN FAN FAN

P P P S S S G G S S S S G G
100 x E1s STM-64 D Q Q L F L X X L F L E S S
3 1 1 1 1 6 C C 6 1 1 P C C
6 x E3s STM-16 (FEC) 6 6 4 S S 4 6 6 1 C C

S S S S S S S S S S S S S S S S S S
2 x STM-1e STM-16 l l l l l l l l l l l l l l l l l l
o o o o o o o o o o o o o o o o o o
t t t t t t t t t t t t t t t t t t
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1
0 2 2 3 4 5 6 7 8
OptiX OSN 3500 Fiber Routing

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page155
Regenerator (Cont.)
 OptiX OSN 3500 fiber connection as REG & ADM

SL64 SL64 SL64 SL64


IN OUT OUT IN

OSN OSN
3500 OUT IN IN OUT
3500

Fiber connection for REG

IN OUT OUT IN

OSN OSN
3500 OUT IN IN OUT 3500
PQ1
SL16 SL16 SL16 SL16

Fiber connection for ADM

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page156
Common network elements summary

ADM ADM
MADM

STM-64 STM-16 REG


REG

STM-1

ADM ADM
TM
Low-rate signals

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page157
Contents
1. Product Introduction

2. Cabinet, Sub-rack

3. Boards

4. Common Network Elements and Configuration

5. Features

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page158
Equipment Protection -OSN1500
Items protected Protection scheme
E1/T1 processing board 1:2 TPS
E3/DS3 processing board
E4/STM-1 processing board 1:1 TPS
FE Processing board
Core unit 1+1 hot backup protection
-48V power interface card 1+1 hot backup protection
3.3V card power supply 1:N centralized hot backup protection
* The OptiX OSN 1500 can support two TPS groups of different types of services at the one time.

 1:2 TPS of E1/T1 board  1:1 TPS of E3/T3 board


SLOT 14 SLOT 14
SLOT 18 PIU SLOT 18 PIU
SLOT 15 SLOT 15
SLOT 16 SLOT 16
SLOT 19 PIU SLOT 19 PIU
SLOT 17 SLOT 17
Protection SLOT 6 (622M) SLOT11 SLOT 6 (622M)
Working SLOT 7 (622M) Protection SLOT 7 (622M)
Slot 20 Slot 20
Working SLOT 8 (622M) Working SLOT 8 (622M)
FAN FAN
SLOT 4 CXL1/4, CXL16 SLOT 9 (622M) SLOT 4 CXL1/4, CXL16 SLOT 9 (622M)
SLOT 5 CXL1/4, CXL16 SLOT 10 AUX SLOT 5 CXL1/4, CXL16 SLOT 10 AUX

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page159
Equipment Protection –OSN2500
Items protected Protection scheme

E1/T1 processing card 1:N (N 4) TPS


E3/T3 processing card 1:1 TPS (2 Groups)
E4/STM-1 processing card 1:1 TPS (2 Groups)
FE processing board 1:1 TPS (2 Groups)
Core unit 1+1 hot backup protection
-48V power interface card 1+1 hot backup protection
3.3V card power supply 1:N centralized hot backup protection
* The OptiX OSN 2500 can support two TPS groups of different types of services at the same time.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page160
Equipment Protection –OSN2500 (Cont.)
S S S S S S S S S S S S S S S S S S
L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
T
1
T
2
T
3
T
4
T
5
T
6
T
7
T
8
T
9
T
10
T
11
T
12
T
13
T
14
T
15
T
16
T
17
T
18
 1:4 TPS of E1/T1 board
C C S
X X A
L L P

P W W W W

S S S S S S S S S S S S S S S S S S
L L L L L L L L L L L L L L L L L L
O O O O O O O O O O O O O O O O O O
T T T T T T T T T T T T T T T T T T
 2 groups 1:1 TPS for 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

E3/T3/E4/STM-1(e)/FE board T
S
C
X
C
X
S
A
T
S
B L L P B

P W W P

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page161
Equipment Protection –OSN3500

Items protected Protection scheme


E1/T1 processing board 1:N (N  8) TPS
E3/T3 processing board 1:N (N  3) TPS (2 Groups)
E4/STM-1e processing board 1:N (N  3) TPS (2 Groups)
FE Processing board 1:N (N = 1) (2 Groups)
Cross-connect and timing unit 1+1 hot backup protection
SCC unit 1+1 hot backup protection
-48V power interface board 1+1 hot backup protection
3.3V board power supply 1:N centralized hot backup protection

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page162
Equipment Protection –OSN3500 (Cont.)
 1:8 TPS of E1/T1 board  3 groups of mixed TPS
S S S S S S S S S
S S S S S S S S S S S S S S S S S S S S S S S S S S S
1 1 1 1
L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L
3 4 5 6
O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O
T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T
E4 E4 E4 E4
1 2 3 4 5 6 7 8 9 1 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8 9 1 1 1 1 1
/1 /1 /1 /1
0 1 2 3 4 5 6 7 8 0 1 2 7 8
5 5 5 5

E3 Protection
E3 Working
E1 Working
E1 Working
E1 Protection
5 5 5 5
Working
Protection
Working
Working
Working

Working
Working
Working
Working
M M M M
S S S S
C C W WW P C C
C C C C

 FE board1:1 TPS S
L
S S S
2 3 L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S
L
S S
L 1
S S S
1 L L
O O O O O O O O O O O O 5 6 O O
T T T T T T T T T T T T T T
1 4 5 6 7 8 9 1 1 1 1 1 1 1
F F 0 1 2 3 4 F F 7 8
E E E E

X X S S
C C C C
P W S S W P C C

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page163
Equipment Protection (Cont.)
 Fans
 The mutual backup of power supplies for the fans

 Automatic fan speed adjustment


 Once one fan modules goes faulty, the others will operate at their full speed.

 Turns off the fans at low temperature

 Abnormality-Specific Board Protection


 Check function of application program and data

 Over-voltage and under-voltage protection

 Board temperature check

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page164
Network Level Protections
Protections Types
1+1 MSP
Linear MSP
1:N (1 ≤ N ≤ 14) MSP
2-fiber bidirectional MSP ring
MSP ring 2-fiber unidirectional MSP ring
4-fiber bidirectional MSP ring
Mesh Protection Intelligent function
SNCP
Dual node interconnection (DNI)
Fiber-Shared Virtual Path Protection
MS-Shared Optical Path Protection
RPR
VP-Ring/VC-Ring Protection

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page165
Intelligent Features
 Service level agreement (SLA)

 Topology automatic discovery function

 Automatic end-to-end service configuration

 Support mesh networking and protection

 Traffic engineering

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page166
Resilient Packet Ring (RPR)
 Topology automatic discovery function

 Fair algorithm

 3 service levels

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page167
Summary
 Product Introduction

 Cabinet, Sub-rack and Boards

 Common Network Elements and Configuration

 Features

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page168
Thank you
www.huawei.com

You might also like