Specification
GENERAL 16V150LTD GAS ENGINE DATA
Cylinder: V 16
Piston Displacement: 48L (2924 cu.in.)
Bore & Stroke: 152 x 165 mm (5.98” x 6.5”)
Jacket Water System Capacity: 159L (42 gal.)
Lube Oil Capacity: 820 L (215 gal.)
Starting System: 8.5‐10 bar (125 ‐ 150 psi) air/gas 24 VDC electric
Dry Weight: 7730 kg (17,000 lb. )
Gas Engine Performance Data
Site Conditions
Fuel WKI 99.21 99.21 99.21
Fuel LHV MJ/m3 34.74 34.74 34.74
Ambient °C 37 37 37
Altitude meters 85 85 85
Engine Performance
Power kWb 1036 882 804
Speed RPM 1500 1500 1500
BSFC (LHV) (tolerance +5%) kJ/kWh 8494 8659 8765
Induction Air Nm3/hr 3959 3394 3114
Exhaust Flow kg/hr 5406 4636 4255
Exhaust Temp °C 385 404 414
2
Heat to kW
Emission mg/Nm3
NOx 500 500 500
CO 750 800 800
NMHC 180 200 200
Ignition timing and Carb Setting determined by ESM based on load, speed, Desired NOx, O2 Offset, and
WKI(TM). O2 Offset may need to be adjusted in ESP to meet emissions at different operating points.
Configuration includes a unit mounted heat exchanger to combine jacket water, lube oil, and first stage
intercooler into one circuit with an estimated combined heat of 652 kW based on a water inlet
temperature 75°C.
BSFC is stated in lower heating value (LHV).NOx emission at absolute humidity of 10.71 g H2O/kg of dry air.
Fuel must comply with the Gaseous Fuel Specification in effect at the time of approval. All data is based on
500 mg/Nm3 Nox ESM calibration. Maximum allowed normal oil header temperature is 88C. Extended
operation below 75% load is not recommended. Increased maintenance and oil change intervals will result
if running at loads below 75% load for extended periods of time. Lube oil change intervals may be shorter
due to increased jacket water temperatures.
Gas Engine Specification:
Flex connections [1000A] – Includes(1) fuel , (1) exhaust, (2) jacket water (HT), and (2) auxiliary
water (HT) flexes. For isolator mount installations.
APG1000 CHP Configuration [1002] – Increases thermal efficiency from 38.2% to 44.6% (50 Hz)
and 40.9% to 47.6%(60 Hz).
[2071] Thermally released gas train shutoff valve for APG1000 CHP configuration on natural gas.
High Efficiency Generator [3000] – Increase generator efficiency from 96.5% tp 96.9% at 50 Hz and
96.2% to 96.8% at 60 Hz.
Generator Space Heater [3021] – 230V AC, single phase, 50/60 Hz. Automatically disconnected
when engine is running, wiring brought to AC junction box.
3
Winding Temperature and Generator Bearing Temperature Detector [3068] – 100 ohm platinum
resistive temperature detector (RTD), with a temperature coefficient of 0.00385 ohms/ohm/°C,
one per phase, total of three, and one bearing. Includes 25 ft (7.6 m) customer interface harness.
Waukesha MICROSPIN Oil Filtration System [5112A] – MICROSPIN centrifugal bypass oil filter with
shutoff valve.
Oil Level Regulator and Quick Fill Valve [5200B] – Kenco oil level regulator. Quick fill mounted and
piped to regulator.
Lubrication Oil Heater [5206A] – 2,500 watt heating element. Thermostatically controlled (100° F
on; 120° F off). Engine mounted , designed for indoor duty. Continuous prelube not available.
Pump motor: 24V DC. ESM controlled.
Level Switches [6112] – Low lube oil level warning and shutdown and high lube oil level warning
switches, 24V DC, 2 amps. Includes 25 ft (7.6 m) customer interface harness. Note: Heat
exchanger cooled units include low water warning and shutdown for jacket and auxiliary circuits.
Shipped with surge tank assembly.
Exhaust Thermocouples [6205] – Type K, (18 total), individual cylinders plus (1) pre turbine and (1)
post turbine. Main bearing thermocouples, Type K, (9 total). Includes 25 ft (7.6 m) customer
interface harness.
Additional Sensors [6210] – Pressure senders for jacket water and fuel pressure. Temperature
senders for auxiliary water inlet and fuel gas. Vibration transducers – Two (2) sensing elements,
engine and generator. Includes 25 ft (7.6 m) customer interface harness.
Vibration Isolators [ 9509B] – Spring type. Requires longer flex connections (not supplied).
GENERATOR LEROY SOMER LS541‐VL12 DATA:
Generator Specification please see the enclosure.
4
SINGLE/MULTIPLE UNIT CONTROL FOR PARALLELING
Technical parameters of gas
Kind of gas Natural gas
Calorific value min. 31 MJ/Nm3
ca. 97,8 % capacity
Methan contents (CH4)
Ethane, Propane, Butane ca. 1 % capacity
Nitrogen (N2) ca. 1 % capacity
Carbon dioxide (CO2) and other ca. 0,2 % capacity
BASIC SPECIFICATION for GDGS APG1000 type
Generating Set type ‐ APG1000
Fuel Natural gas
Electric efficiency of generator (cos φ = 1) % 96,9
Voltage of generator V 400
5
Mechanical output of GEGS kWm 1036
Electrical efficiency ( +5% of tolerance) % 41,1
Technical guarantee and servicing
The manufacturer provides a technical guarantee for a period of 12 months counting from the final
acceptance test of the power respectively 18 months from notification of readiness for dispatch of
the Unit GDGS, which occurs first.
6
All random events are fully covered by our company and at its expense within the guarantee
period provided that, the engine operation will be according with Manual Instruction.
Following the technical guarantee support, we can offer a complete post‐warranty service package.
Enclosure:
1/APG (Advanced Power Generation) Gas ENGINATOR
2/ Generator Specification
3/EPC8000E Enginator Control Panel