You are on page 1of 7

Technical

Specification

Generating Set with Waukesha engine


burning natural gas
The  following  presents  the  Gas  Engine  Generating  Set  (GEGS)  APG1000  type,  based  on 
Waukesha gas engine 16V150LTD. 
Using the GEGS you receive the following benefits: 
* Optimized electrical efficiency for nominal power by providing a single customer circuit
inlet with temperature of up to 80°C (170°F).
* Includes ECP8000E genset control panel optimized for applications.
* Compact  design  of  GEGS  enable  easy  containerized  or  building  housing  and  easy
maintenance during the operation.

GENERAL 16V150LTD  GAS ENGINE DATA 
Cylinder: V 16 
Piston Displacement: 48L (2924 cu.in.) 
Bore & Stroke: 152 x 165 mm (5.98” x 6.5”) 
Jacket Water System Capacity: 159L (42 gal.) 
Lube Oil Capacity: 820 L (215 gal.) 
Starting System: 8.5‐10 bar (125 ‐ 150 psi) air/gas 24 VDC electric 

Dry Weight: 7730 kg (17,000 lb. ) 

Gas Engine Performance Data 

Engine Model             100%  85%  77% 


16V150LTD 
IC temperature  °C  54 54  54 
JW temperature  °C  99 99   99 
Carb setting  ESM  ESM   ESM 
Timing  °BTDC   ESM   ESM    ESM 

Site Conditions 
Fuel WKI 99.21 99.21 99.21
Fuel LHV  MJ/m3 34.74 34.74 34.74 
Ambient  °C  37 37  37 
Altitude  meters  85  85   85 

Engine Performance 
Power  kWb 1036 882 804 
Speed  RPM 1500 1500 1500 
BSFC (LHV) (tolerance +5%)  kJ/kWh 8494 8659 8765 
Induction Air  Nm3/hr 3959 3394 3114 
Exhaust Flow  kg/hr 5406 4636 4255 
Exhaust Temp  °C  385  404  414 


Heat to  kW 

Jacket Water  376 320 291 


Lube Oil  139 129 124 
First Stage Intercooler    136 95   78 
Second Stage Intercooler  74 62   57 
Total Exhaust  614 559 528 
Radiation  69  74    76 

Emission  mg/Nm3
NOx  500 500 500 
CO 750 800 800
NMHC 180 200 200

Ignition  timing and Carb Setting  determined  by ESM  based    on load, speed,  Desired  NOx, O2  Offset,  and 
WKI(TM).  O2 Offset  may need to be adjusted  in ESP  to meet  emissions at different operating points. 
Configuration  includes a unit mounted heat exchanger to combine jacket water, lube oil, and first stage 
intercooler  into  one  circuit  with  an  estimated  combined  heat  of  652  kW  based  on  a  water  inlet 
temperature 75°C. 
BSFC is stated in lower  heating  value (LHV).NOx emission  at absolute humidity of 10.71 g H2O/kg of dry air. 
Fuel must comply with the Gaseous Fuel Specification  in effect at the time of approval. All data is based on 
500 mg/Nm3  Nox  ESM calibration.  Maximum allowed  normal oil header  temperature  is 88C.  Extended 
operation  below 75% load is not recommended. Increased maintenance and oil change intervals will result 
if running at loads below 75% load for extended periods of time. Lube oil change intervals may be shorter 
due to increased jacket water temperatures. 

Gas Engine Specification: 
 Flex  connections  [1000A]  –  Includes(1)  fuel  ,  (1)  exhaust,  (2)  jacket  water  (HT),  and  (2)  auxiliary
water (HT) flexes. For isolator mount installations.
 APG1000  CHP  Configuration  [1002]  –  Increases  thermal  efficiency  from  38.2%  to  44.6%  (50  Hz)
and 40.9% to 47.6%(60 Hz).
 [2071] Thermally released gas train shutoff valve for APG1000 CHP configuration on natural gas.
 High Efficiency Generator [3000] – Increase generator efficiency from 96.5% tp 96.9% at 50 Hz and
96.2% to 96.8% at 60 Hz.
 Generator  Space  Heater  [3021]  –  230V  AC,  single  phase,  50/60  Hz.  Automatically  disconnected
when engine is running, wiring brought to AC junction box.


 Winding Temperature and Generator Bearing Temperature Detector [3068] – 100 ohm platinum
resistive  temperature  detector  (RTD),  with  a  temperature  coefficient  of  0.00385  ohms/ohm/°C,
one per phase, total of three, and one bearing. Includes 25 ft (7.6 m) customer interface harness.
 Waukesha MICROSPIN Oil Filtration System [5112A] – MICROSPIN centrifugal bypass oil filter with
shutoff valve.
 Oil Level Regulator and Quick Fill Valve [5200B] – Kenco oil level regulator. Quick fill mounted and
piped to regulator.
 Lubrication Oil Heater [5206A] – 2,500 watt heating element. Thermostatically controlled (100° F
on;  120°  F  off).  Engine  mounted  ,  designed  for  indoor  duty.  Continuous  prelube  not  available.
Pump motor: 24V DC. ESM controlled.
 Level Switches [6112] – Low lube oil level warning and shutdown and high lube oil level warning
switches,  24V  DC,  2  amps.  Includes  25  ft  (7.6  m)  customer  interface  harness.  Note:  Heat
exchanger  cooled units include low water warning and shutdown for jacket and auxiliary circuits.
Shipped with surge tank assembly.
 Exhaust Thermocouples [6205] – Type K, (18 total), individual cylinders plus (1) pre turbine and (1)
post  turbine.  Main  bearing  thermocouples,  Type  K,  (9  total).  Includes  25  ft  (7.6  m)  customer
interface harness.
 Additional  Sensors  [6210]  –  Pressure  senders  for  jacket  water  and  fuel  pressure.  Temperature
senders for auxiliary water inlet and fuel gas. Vibration transducers – Two (2) sensing elements,
engine and generator. Includes 25 ft (7.6 m) customer interface harness.
 Vibration Isolators [ 9509B] – Spring type. Requires longer flex connections (not supplied).

GENERATOR LEROY SOMER LS541‐VL12 DATA:   
Generator Specification please see the enclosure. 


SINGLE/MULTIPLE UNIT CONTROL FOR PARALLELING 

The  Model  ECP8000E  panel  consists  of  one  free 


standing  steel  enc  losure  for  controlling  single  or 
multiple units in parallel. Panel dimensions: 764mm  
x 459mm x 1830mm (30"W x 18"D x 72"H). Rated for 
indoor  use:  operating  temperature  ‐20°C  to  +70°C 
(‐4°F  to  +158°F),  relative  humidity  0‐95%  (non‐
condensing).  The  HMI  (Human  Machine  Interface), 
control  switches  and  indicating  lights  are  mounted 
through the hinged door. 
     

Technical parameters of gas 

Kind of gas  Natural gas 

Calorific value  min. 31 MJ/Nm3 
ca. 97,8 % capacity 
Methan contents (CH4) 

Ethane, Propane, Butane  ca. 1 % capacity 

Nitrogen (N2)  ca. 1 % capacity 

Carbon dioxide (CO2) and other  ca. 0,2 % capacity 

BASIC SPECIFICATION for GDGS APG1000 type 

Generating Set  type  ‐ APG1000

Fuel  Natural gas 

Rotational speed (50Hz)  rpm  1500 

Nominal shaft power  kWm  1 036 / engine 

Electric efficiency of generator (cos φ = 1)  %  96,9 

Voltage of generator  V  400 

Frequency  Hz  50 


Mechanical output of GEGS  kWm  1036 

Electrical output of GEGS (for cos φ = 1)  kWe  1004 


Mechanical efficiency on engine shaft (+5% of  
%  42,4 
tolerance) 

Electrical efficiency ( +5% of tolerance)  %  41,1 

Energy input  kW  2359 

Heat Rate (tolerance +5%)  kJ/kWhm  8 494 

Heat Rate on generator shaft (tolerance +5%)  kJ/kWhe  8 765 

Engine fuel consumption / hour for LHV=34,74  Nm3/h  245 

Technical guarantee and servicing 
The manufacturer provides a technical guarantee for a period of 12  months counting from the final 
acceptance test of the power respectively 18 months from notification of readiness for dispatch of 
the Unit GDGS, which occurs first. 


All  random  events  are  fully  covered  by  our company  and  at  its  expense  within  the  guarantee 
period  provided  that,  the  engine  operation  will  be  according  with  Manual  Instruction. 
Following  the technical guarantee support, we can offer a complete post‐warranty service package. 

Enclosure: 
1/APG (Advanced Power Generation) Gas ENGINATOR  
2/ Generator Specification 
3/EPC8000E Enginator Control Panel 

You might also like